USGS ScienceSearch

SEARCH · USGS Science

Results for “Biological Mass Spectrometry”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Trace silicon determination in biological samples by inductively coupled plasma mass spectrometry (ICP-MS): Insight into volatility of silicon species in hydrofluoric acid digests for optimal sample preparation and introduction to ICP-MS

A method for the determination of trace levels of silicon from biological materials by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. The volatility of water-soluble silicon species, hexafluorosilicic acid (H 2 SiF 6 ), and sodium metasilicate (Na 2 SiO 3 ) was investigated by evaporating respective solutions (50 µg/mL silicon) in nitric acid (HNO 3 ), nitric acid + hydrochloric acid (HNO 3 + HCl), and nitric acid + hydrochloric acid + hydrofluoric acid (HNO 3 + HCl + HF) at 120 °C on a hot-block to near dryness. The loss of silicon from H 2 SiF 6 solutions was substantial (>99%) regardless of the digestion medium. Losses were also substantial (>98%) for metasilicate solutions heated in HNO 3 + HCl + HF, while no significant loss occurred in HNO 3 or HNO 3 + HCl. These results show that H 2 SiF 6 species were highly volatile and potential losses could confound accuracy at trace level determinations by ICP-MS if digestates prepared in HF are heated to eliminate HF. Among the various matrices comprising major elements, sodium appeared to be effective in reducing silicon loss from H 2 SiF 6 solutions. Excess sodium chloride (NaCl) matrix provided better stability, improving silicon recoveries by up to about 80% in evaporated HF digestates of soil and mine waste samples, but losses could not be fully prevented. To safely remove excess acids and circumvent the adverse effects of excess HF (e.g., risk of high Si background signals), a two-step digestion scheme was adopted for the preparation of biological samples containing trace silicon levels. A closed-vessel digestion was performed either in 4 mL of concentrated HNO 3 and 1 mL of concentrated HCl or 4 mL of concentrated HNO 3 , 1 mL of concentrated HCl and 1 mL of concentrated HClO 4 on a hot plate at 140 °C. Digestates were then evaporated to incipient dryness at 120 °C to remove the acids. A second closed-vessel digestion was carried out to dissolve silicates in 0.5 mL of concentrated HNO 3 and 0.5 mL of concentrated HF at 130 °C. After digestion, digestates were diluted to 10 mL. The solution containing about 5% HNO 3 and 5% HF was directly analyzed by ICP-MS equipped with an HF-inert sample introduction system. The limit of detection was about 110 µg/L for 28 Si when using the Kinetic Energy Discrimination (KED) mode. The method was used to determine silicon in various plant and tissue certified reference materials. Data were acquired for 28 Si using KED and standard (STD) modes, and 74 Ge and 103 Rh as internal standard elements. There was not any significant difference between the accuracy and precision of the results obtained with 74 Ge and 103 Rh within the same measurement mode. Precision, calculated as relative standard deviation for four replicate analyses, varied from 5.3 (tomato leaves) to 21% (peach leaves) for plant and from 2.2 (oyster tissue) to 33% (bovine liver) for tissue SRM/CRMs. Poor precision was attributed to material heterogeneity and the large particle size distribution. An analysis of lung tissue samples from those with occupational exposure to silica dust revealed that tissues possessed substantial levels of water-soluble silicates, but the most silicon was present in the particulate matter fraction.

Minerals

Analysis of chlorinated organic compounds in estuarine biota and sediments by chemical ionization tandem mass spectrometry

Complex sample matrices of estuarine biota tissue and bed sediment extracts were analyzed for selected chlorinated compounds. By using gas chromatography/positive chemical ionization/tandem mass spectrometry, the coeluting interferences present in gas chromatography/electron ionization mass spectrometry were eliminated in the biota tissue and bed sediment extracts. The selected chlorinated compounds included chlorobenzene; 1,2‐, 1,3‐ and 1,4‐dichlorobenzene; 1,2,3‐, 1,2,4‐ and 1,3,5‐trichlorobenzene; 1,2,3,4‐, 1,2,3,5‐ and 1,2,4,5‐tetrachlorobenzene; pentachlorobenzene; hexachlorobenzene; hexachloro‐1,3‐butadiene; octachlorostyrene; and octachloronaphthalene. Daughter ion spectra for these compounds are included. The detection limit for most of the compounds was 20 pg, and the instrument response was linear over five orders of magnitude, by using 13 C‐labelled hexachlorobenzene as the internal standard.

Biological Mass Spectrometry

Identification of isopropylbiphenyl, alkyl diphenylmethanes, diisopropylnaphthalene, linear alkyl benzenes and other polychlorinated biphenyl replacement compounds in effluents, sediments and fish in the Fox River System, Wisconsin

Five polychlorinated biphenyl replacement dye solvents and a diluent present in carbonless copy paper were identified by gas chromatography/mass spectrometry in the following matrices: effluents from a de-inking–recycling paper mill and a municipal wastewater treatment plant receiving wastewaters from a carbonless copy paper manufacturing plant; sediments; and fish collected near both discharges in the Fox River System, Wisconsin. An isopropylbiphenyl dye solvent mixture included mono-, di- and triisopropylbiphenyls. Also identified were two dye solvent mixtures marketed under the trade name Santosol. Santosol 100 comprised ethyl-diphenylmethanes (DPMs), benzyl-ethyl-DPMs, and dibenzyl-ethyl-DPMs. Similarly, Santosol 150 comprised dimethyl-DPMs, benzyl-dimethyl-DPMs, and dibenzyl-dimethyl-DPMs. Diisopropylnaphthalenes, widely used as a dye solvent in Japan, were identified for the first time in the US environment. sec -Butylbiphenyls and di- sec -butylbiphenyls, likely constituents of a sec -butylbiphenyl dye solvent mixture, were tentatively identified. Linear alkyl benzenes (C 10 to C 13 -LABs) constituted the Alkylate 215 diluent mixture. Although known to occur as minor constituents in linear alkyl sulfonate detergents, LAB residues have not been previously attributed to commercial use of LABs.

Wisconsin

An improved technique for the 2H/1H analysis of urines from diabetic volunteers

The H2-H2O ambient-temperature equilibration technique for the determination of 2H/1H ratios in urinary waters from diabetic subjects provides improved accuracy over the conventional Zn reduction technique. The standard deviation, ~ 1-2???, is at least a factor of three better than that of the Zn reduction technique on urinary waters from diabetic volunteers. Experiments with pure water and solutions containing glucose, urea and albumen indicate that there is no measurable bias in the hydrogen equilibration technique.The H2-H2O ambient-temperature equilibration technique for the determination of 2H/1H ratios in urinary waters from diabetic subjects provides improved accuracy over the conventional Zn reduction technique. The standard deviation, approximately 1-2%, is at least a factor of three better than that of the Zn reduction technique on urinary waters from diabetic volunteers. Experiments with pure water and solutions containing glucose, urea and albumen indicate that there is no measurable bias in the hydrogen equilibration technique.

Biological Mass Spectrometry

87 Sr/ 86 Sr isotope ratio analysis by laser ablation MC-ICP-MS in scales, spines, and fin rays as a nonlethal alternative to otoliths for reconstructing fish life history

Strontium isotope ratios ( 87 Sr/ 86 Sr) in otoliths are a well-established tool to determine origins and movement patterns of fish. However, otolith extraction requires sacrificing fish, and when working with protected or endangered species, the use of nonlethal samples such as scales, spines, and fin rays is preferred. Unlike otoliths that are predominantly aragonite, these tissues are composed of biological apatite. Laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) analysis of biological apatite can induce significant interference on mass 87, causing inaccurate 87 Sr/ 86 Sr measurements. To quantify this interference, we applied LA-MC-ICP-MS to three marine samples (white seabass ( Atractoscion nobilis ) otolith; green sturgeon ( Acipenser medirostris ) pectoral fin ray; salmon shark ( Lamna ditropis ) tooth), and freshwater walleye ( Sander vitreus ) otoliths, scales, and spines). Instrument conditions that maximize signal intensity resulted in elevated 87 Sr/ 86 Sr isotope ratios in the bioapatite samples, related to a polyatomic interference ( 40 Ca 31 P 16 O, 40 Ar 31 P 16 O). Retuning instrument conditions to reduce oxide levels removed this interference, resulting in accurate 87 Sr/ 86 Sr ratios across all tissue samples. This method provides a novel, nonlethal alternative to otolith analysis to reconstruct fish life histories.

Wyoming

The Stanford-U.S. Geological Survey SHRIMP ion microprobe--a tool for micro-scale chemical and isotopic analysis

Answers to many questions in Earth science require chemical analysis of minute volumes of minerals, volcanic glass, or biological materials. Secondary Ion Mass Spectrometry (SIMS) is an extremely sensitive analytical method in which a 5–30 micrometer diameter "primary" beam of charged particles (ions) is focused on a region of a solid specimen to sputter secondary ions from 1–5 nanograms of the sample under high vacuum. The elemental abundances and isotopic ratios of these secondary ions are determined with a mass spectrometer. These results can be used for geochronology to determine the age of a region within a crystal thousands to billions of years old or to precisely measure trace abundances of chemical elements at concentrations as low as parts per billion. A partnership of the U.S. Geological Survey and the Stanford University School of Earth Sciences operates a large SIMS instrument, the Sensitive High-Resolution Ion Microprobe with Reverse Geometry (SHRIMP–RG) on the Stanford campus.

Fact Sheet

High-precision measurement of variations in calcium isotope ratios in urine by multiple collector inductively coupled plasma mass spectrometry

We describe a new chemical separation method to isolate Ca from other matrix elements in biological samples, developed with the long-term goal of making high-precision measurement of natural stable Ca isotope variations a clinically applicable tool to assess bone mineral balance. A new two-column procedure utilizing HBr achieves the purity required to accurately and precisely measure two Ca isotope ratios ( 44 Ca/ 42 Ca and 44 Ca/ 43 Ca) on a Neptune multiple collector inductively coupled plasma mass spectrometer (MC-ICPMS) in urine. Purification requirements for Sr, Ti, and K (Ca/Sr > 10000; Ca/Ti > 10000000; and Ca/K > 10) were determined by addition of these elements to Ca standards of known isotopic composition. Accuracy was determined by (1) comparing Ca isotope results for samples and standards to published data obtained using thermal ionization mass spectrometry (TIMS), (2) adding a Ca standard of known isotopic composition to a urine sample purified of Ca, and (3) analyzing mixtures of urine samples and standards in varying proportions. The accuracy and precision of δ 44/42 Ca measurements of purified samples containing 25 μg of Ca can be determined with typical errors less than ±0.2‰ (2σ).

Analytical Chemistry

Quantification of 15 bile acids in lake charr feces by ultra-high performance liquid chromatography–tandem mass spectrometry

Many fishes are hypothesized to use bile acids (BAs) as chemical cues, yet quantification of BAs in biological samples and the required methods remain limited. Here, we present an UHPLC–MS/MS method for simultaneous, sensitive, and rapid quantification of 15 BAs, including free, taurine, and glycine conjugated BAs, and application of the method to fecal samples from lake charr ( Salvelinus namaycush ). The analytes were separated on a C 18 column with acetonitrile–water (containing 7.5 mM ammonium acetate and 0.1% formic acid) as mobile phase at a flow rate of 0.25 mL/min for 12 min. BAs were monitored with a negative electrospray triple quadrupole mass spectrometer (Xevo TQ-S™). Calibration curves of 15 BAs were linear over the concentration range of 1.00–5,000 ng/mL. Validation revealed that the method was specific, accurate, and precise. The method was applied to quantitative analysis of feces extract of fry lake charr and the food they were eating. The concentrations of analytes CA, TCDCA, TCA, and CDCA were 242.3, 81.2, 60.7, and 36.2 ng/mg, respectively. However, other taurine conjugated BAs, TUDCA, TDCA, and THDCA, were not detected in feces of lake charr. Interestingly, TCA and TCDCA were detected at high concentrations in food pellets, at 71.9 and 38.2 ng/mg, respectively. Application of the method to feces samples from lake charr supported a role of BAs as chemical cues, and will enhance further investigation of BAs as chemical cues in other fish species.

Journal of Chromatography B: Analytical Technologi

Photochemical mobilization of dissolved hydrocarbon oxidation products from petroleum contaminated soil into a shallow aquifer activate human nuclear receptors

Elevated non-volatile dissolved organic carbon (NVDOC) concentrations in groundwater monitoring wells under oil-contaminated hydrophobic soils originating from a pipeline rupture at the National Crude Oil Spill & Natural Attenuation Research Site near Bemidji, MN are documented.. We hypothesized the elevated NVDOC is comprised of water-soluble photooxidation products transported from the surface to the aquifer. We use field and laboratory samples in combination with complementary analytical methods to test this hypothesis and determine the biological response to these products. Observations from optical spectroscopy and ultrahigh-resolution mass spectrometry reveal a significant correlation between the chemical composition of NVDOC leached from photochemically weathered soils and groundwater monitoring wells with high NVDOC concentrations measured in the aquifer beneath the contaminated soil. Conversely, the chemical composition from the uncontaminated soil photoleachate, matches the NVDOC observed in the uncontaminated wells. Contaminated groundwater and photodissolution leachates from contaminated soil activated biological targets indicative of xenobiotic metabolism and exhibited potential for adverse effects. Newly formed hydrocarbon oxidation products (HOPs) from fresh oil could be distinguished from those downgradient. This study illustrates another pathway for dissolved HOPs to infiltrate groundwater and potentially affect human health and the environment.

Minnesota

Methods of analysis—Determination of pesticides in filtered water and suspended sediment using liquid chromatography- and gas chromatography-tandem mass spectrometry

The widespread application of pesticides in agricultural and urban areas leads to their presence in surface waters. Presence of these biologically active chemicals in environmental waters potentially has adverse effects on nontarget organisms. To better understand the environmental fate of these contaminants, a robust method to capture chemicals with wide-ranging physicochemical properties has been developed. The method was developed by the U.S. Geological Survey’s Organic Chemistry Research Laboratory to monitor pesticides, pesticide degradates, and other agrochemicals in environmental surface waters throughout the country. The analysis involves a multiresidue method to determine 183 pesticides and pesticide degradates in filtered water samples and 178 pesticides and pesticide degradates in paired suspended sediment samples. After the filtration of whole water, contaminants are individually measured in the filtered water and the collected suspended sediment. Filtered water is extracted via solid-phase extraction, whereas suspended sediment is extracted using an ultrasonication, solid-liquid extraction. Samples are analyzed by liquid chromatography-tandem mass spectrometry using an electrospray ionization source in positive and negative modes and analyzed by gas chromatography-tandem mass spectrometry using an advanced electron ionization source in positive mode. Instrument parameters were optimized for the highest sensitivity, and at least two transitions (quantifier and qualifier) were monitored for each analyte. Recoveries in test filtered water ( n =9; 183 analytes) from the American River, California, and suspended sediment ( n =9; 178 analytes) samples fortified at 15 nanograms per liter (ng/L) ranged from 70.1 to 121.0 and 71.1 to 117.0 percent in water and suspended sediment filter samples, respectively. Method detection limits of pesticides and pesticide degradates ranged from 0.5 to 10.6 ng/L in water and 0.7 to 11.8 ng/L in suspended sediment filters. Reporting limits were 1.1–21.1 ng/L and 1.5–23.7 ng/L in water and filter samples, respectively. The developed method is applied to surface-water samples for the analysis of pesticides, pesticide degradates, and other agrochemicals.

Techniques and Methods

Lake Louise Water (USGS47): A new isotopic reference water for stable hydrogen and oxygen isotope measurements

"RATIONALE: Because of the paucity of isotopic reference waters for daily use, a new secondary isotopic reference material has been prepared from Lake Louise water from Alberta, Canada for international distribution. MOTHODS: This water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule. RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "

Rapid Communications in Mass Spectrometry

Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ 2 H and δ 18 O measurements of water

RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ 2 H and δ 18 O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty ( U  = 2 u c ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer.

Rapid Communications in Mass Spectrometry

A new isotopic reference material for stable hydrogen and oxygen isotope-ratio measurements of water—USGS50 Lake Kyoga Water

Rationale As a result of the need for isotopic reference waters having high δ 2 H VSMOW-SLAP and δ 18 O VSMOW-SLAP values for daily use, especially for tropical and equatorial-zone freshwaters, a new secondary isotopic reference material for international distribution was prepared from water collected from Lake Kyoga, Uganda. Methods This isotopic reference lakewater was filtered through a membrane with 0.2-µm pore size, homogenized, loaded into glass ampoules that were sealed with a torch and autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available in a case of 144 glass ampoules each containing 5 mL of water. Results The δ 2 H and δ 18 O values of this reference material are +32.8 ± 0.4 and +4.95 ± 0.02 mUr (milliurey = 0.001 = 1 ‰), respectively, relative to VSMOW, on scales normalized such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty ( U  = 2 u c ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. Conclusions This isotopic reference material, designated as USGS50, is intended as one of two reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer, of use especially for isotope-hydrology laboratories analyzing freshwater samples from equatorial and tropical regions.

Lake Kyoga

USGS48 Puerto Rico precipitation - A new isotopic reference material for δ 2 H and δ 18 O measurements of water

A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ 2 H) and stable oxygen (δ 18 O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ 2 H and δ 18 O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ 2 H and δ 18 O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty ( U =2 u c ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.

Puerto Rico

Antarctic ice-core water (USGS49) – A new isotopic reference material for δ2H and δ18O measurements of water

As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ 2 H and δ 18 O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty ( U = 2 u c ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.

Geostandards and Geoanalytical Research

USGS46 Greenland ice core water – A new isotopic reference material for δ2H and δ18O measurements of water

Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (δ 2 H) and stable oxygen (δ 18 O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured δ 2 H and δ 18 O values of this reference water were −235.8 ± 0.7‰ and −29.80 ± 0.03‰, respectively, relative to VSMOW on scales normalised such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, −428 and −55.5‰. Each uncertainty is an estimated expanded uncertainty ( U = 2 u c ) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.

Geostandards and Geoanalytical Research

High-precision 41K/39K measurements by MC-ICP-MS indicate terrestrial variability of δ41K

Potassium is a major component in continental crust, the fourth-most abundant cation in seawater, and a key element in biological processes. Until recently, difficulties with existing analytical techniques hindered our ability to identify natural isotopic variability of potassium isotopes in terrestrial materials. However, measurement precision has greatly improved and a range of K isotopic compositions has now been demonstrated in natural samples. In this study, we present a new technique for high-precision measurement of K isotopic ratios using high-resolution, cold plasma multi-collector mass spectrometry. We apply this technique to demonstrate natural variability in the ratio of 41 K to 39 K in a diverse group of geological and biological samples, including silicate and evaporite minerals, seawater, and plant and animal tissues. The total range in 41 K/ 39 K ratios is ca. 2.6‰, with a long-term external reproducibility of 0.17‰ (2, N=108). Seawater and seawater-derived evaporite minerals are systematically enriched in 41 K compared to silicate minerals by ca. 0.6‰, a result consistent with recent findings1, 2. Although our average bulk-silicate Earth value (-0.54‰) is indistinguishable from previously published values, we find systematic δ 41 K variability in some high-temperature sample suites, particularly those with evidence for the presence of fluids. The δ 41 K values of biological samples span a range of ca. 1.2‰ between terrestrial mammals, plants, and marine organisms. Implications of terrestrial K isotope variability for the atomic weight of K and K-based geochronology are discussed. Our results indicate that high-precision measurements of stable K isotopes, made using commercially available mass spectrometers, can provide unique insights into the chemistry of potassium in geological and biological systems.

Journal of Analytical Atomic Spectrometry

An isotope-dilution standard GC/MS/MS method for steroid hormones in water

An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

Book chapter