USGS ScienceSearch

USGS · tm5A12

Methods of analysis—Determination of pesticides in filtered water and suspended sediment using liquid chromatography- and gas chromatography-tandem mass spectrometry

Abstract

The widespread application of pesticides in agricultural and urban areas leads to their presence in surface waters. Presence of these biologically active chemicals in environmental waters potentially has adverse effects on nontarget organisms. To better understand the environmental fate of these contaminants, a robust method to capture chemicals with wide-ranging physicochemical properties has been developed. The method was developed by the U.S. Geological Survey’s Organic Chemistry Research Laboratory to monitor pesticides, pesticide degradates, and other agrochemicals in environmental surface waters throughout the country. The analysis involves a multiresidue method to determine 183 pesticides and pesticide degradates in filtered water samples and 178 pesticides and pesticide degradates in paired suspended sediment samples. After the filtration of whole water, contaminants are individually measured in the filtered water and the collected suspended sediment. Filtered water is extracted via solid-phase extraction, whereas suspended sediment is extracted using an ultrasonication, solid-liquid extraction. Samples are analyzed by liquid chromatography-tandem mass spectrometry using an electrospray ionization source in positive and negative modes and analyzed by gas chromatography-tandem mass spectrometry using an advanced electron ionization source in positive mode. Instrument parameters were optimized for the highest sensitivity, and at least two transitions (quantifier and qualifier) were monitored for each analyte. Recoveries in test filtered water ( n =9; 183 analytes) from the American River, California, and suspended sediment ( n =9; 178 analytes) samples fortified at 15 nanograms per liter (ng/L) ranged from 70.1 to 121.0 and 71.1 to 117.0 percent in water and suspended sediment filter samples, respectively. Method detection limits of pesticides and pesticide degradates ranged from 0.5 to 10.6 ng/L in water and 0.7 to 11.8 ng/L in suspended sediment filters. Reporting limits were 1.1–21.1 ng/L and 1.5–23.7 ng/L in water and filter samples, respectively. The developed method is applied to surface-water samples for the analysis of pesticides, pesticide degradates, and other agrochemicals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael S. Gross, Corey J. Sanders, Matthew D. De Parsia, Michelle L. Hladik. 2024-01-31. Methods of analysis—Determination of pesticides in filtered water and suspended sediment using liquid chromatography- and gas chromatography-tandem mass spectrometry. https://doi.org/10.3133/tm5a12

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

dMODELS, a MATLAB software package for modeling crustal deformation near volcanic centers and active faults using Global Navigation Satellite System data—User guide

dMODELS is a MATLAB software package that implements the most common analytical models used to interpret deformation measurements near faults and active volcanic centers. This manual focuses on inversion of deformation data from the Global Navigation Satellite System (GNSS). The included case studies emphasize the GNSS inversion component of the software. Source models include pressurized spherical, spheroidal, and horizontal sill (penny-crack) magma reservoirs in a homogeneous, elastic, isotropic, flat half-space. A topography correction is available for the spherical source. Dikes and faults are described following the mathematical notation for the rectangular dislocations in a homogeneous, elastic, flat half-space. Equations have been reviewed for typographical errors present in the original literature and verified against finite-element method numerical models. GNSS data from the 2006 eruption at Augustine Volcano, Alaska; the 1998–2000 unrest at Taal Volcano, Philippines; and the 2009 earthquake in L’Aquila, Italy, are used to demonstrate the application of the software package.

Techniques and Methods

Aspergillosis (Avian) case definition for wildlife

Diagnostic laboratories receive carcasses and samples for diagnostic evaluation and pathogen/toxin detection. Case definitions bring clarity and consistency to the evaluation process. Their use within and between organizations allows more uniform reporting of diseases and etiologic agents. The intent of a case definition is to provide scientifically based criteria for determining: (a) if an individual carcass has a specific disease and degree of confidence in that diagnosis and (b) if there is evidence of a pathogen or toxin in a carcass or sample (for example, swab, tissue sample, skin scraping, blood/serum sample, environmental sample, or other). This case definition is specific to aspergillosis and applies to all avian species.

Techniques and Methods

Field sampling guidelines for developing and verifying satellite remote sensing chlorophyll a concentration and fluorescence models in inland waters

Harmful algal blooms are increasing in frequency in inland waters across the United States, resulting in a need to monitor phytoplankton bloom events to track ecosystem health and productivity. Remote sensing of chlorophyll a values offers a cost-effective and powerful method for early detection and characterization of bloom events and serves as an overall indicator of water quality and trophic state, with regular, repeated sampling of landscape-wide, high spatial resolution measurements. Field measurements are necessary for developing and verifying chlorophyll a retrieval models. For model verification, chlorophyll a concentration or fluorescence and light attenuation measurements are needed; for model development, turbidity and colored dissolved organic matter concentration measurements are additionally needed; and for model development and verification, radiometric measurements, taxonomic identification of phytoplankton, inherent optical properties, and cyanotoxin concentration are further measurements that can provide context. This report outlines detailed methods and priority considerations for collecting high-quality field data in inland waters (defined as rivers, lakes, reservoirs, estuaries, streams, and wetlands). The described methods include best practices for collecting and preparing discretely collected water samples and for calibration, maintenance, and quality assurance and quality control of field sensors. Whereas the priorities will vary between applications, some general guidelines are to collect field samples (1) as close in time to a satellite overpass as possible, (2) from representative areas of the waterbody to capture the range of spatial variability, and (3) near the surface to match remote sensing reflectance data.

Techniques and Methods