Hydrologic analysis of an earthen embankment dam in southern Westchester County, New York

Abstract

In 2001, the New York City Department of Environmental Protection installed 25 wells on the southern embankment of the Hillview Reservoir in Westchester County in an unsuccessful attempt to locate the source of a large seep (seep A) that began flowing continuously in 1999. In 2005, the U.S. Geological Survey began a cooperative study with the NYCDEP to characterize the hydrology of the local groundwater system and identify potential sources of seep A and other seeps on the embankment. At least two groundwater-flow zones—one shallow and the other deep—overlie the bedrock at the Hillview Reservoir in southern Westchester County, New York. Analyses of slug tests of wells drilled into the southern embankment of the reservoir were used to determine the three-dimensional distribution of hydraulic conductivity of the embankment materials. The wells with the minimum and maximum hydraulic conductivity values are in the deep saturated zone on the southern embankment, where hydraulic conductivity ranges from 0.0012 to 2 feet per day. Hydraulic conductivity ranges from 0.0026 to 1 foot per day in the shallow saturated zone and from 0.021 to 0.27 foot per day in the toe of the embankment. A hydraulic conductivity of 0.016 foot per day was determined for one toe well partially screened in the crystalline-bedrock aquifer. In 2005, the U.S. Geological Survey began a cooperative study with New York City Department of Environmental Protection to characterize the local groundwater-flow system and identify potential sources of seeps on the southern embankment of the Hillview Reservoir in southern Westchester County, New York. Long-term hydrologic data indicated that water levels trended downward in 29 of 41 sites, including the reservoir basin that was monitored during the 12-year study period; data from a National Weather Service precipitation gage at Central Park indicated annual precipitation also trended downward during the same 12-year period. Of the seven wells in which water levels trended upward during the study, two of the wells are on the west side of the southern embankment, proximal to a major water supply conduit, whereas the five remaining wells are screened in the toe. These data indicate an increasing hydrostatic pressure within the deep system and the toe of the dam, which could result in future seeps on the southern embankment near these wells. Results of 11 suspended-sediment samples collected from seeps along the southern embankment at 234.1- and 221.6-feet elevation, and another drainage outflow point between 2007 and 2015 indicate a poor correlation between suspended-sediment concentration and discharge. From the flowing seep at 234.1 feet, suspended-sediment concentrations ranged from 1 milligram per liter at a flow of 2.6 gallons per minute (that is, 1 milligram per 0.26 gallons) during March 2008 to 16 milligrams per liter at 12 gallons per minute during July 2014. At about 12 gallons per minute discharge, suspended-sediment concentration from samples collected at that seep during different sampling events, ranged from 3 to 16 milligrams per liter. From the seep at 221.6 feet elevation, the suspended sediment concentration was 2 milligrams per liter at a discharge of 3.4 gallons per minute and 2 milligrams per liter at a discharge of 1.1 gallons per minute. Only one sample was collected at the drainage outflow point, for which the suspended sediment concentration was 2 milligrams per liter at a discharge of 2.4 gallons per minute. Anomalously high-water levels were recorded in deep-system wells between June 5, 2013, and January 14, 2014. The period for the increase and the decrease back to more typical water-level elevations occurred rapidly during a 13-hour period in each instance. The sudden and rapid changes, in addition to the spatial distribution of magnitude of water-level response indicate that leaky water infrastructure was the source of recharge to the affected wells. A major water supply conduit was drained for repairs between July 7 and 10, 2010. The seeps indicated an immediate response and a substantial hydraulic connection to the water supply conduit. Approximately 10.5 hours after the water supply conduit was drained, flow from a seep on the southern embankment decreased from about 20 gallons per minute to less than 1 gallon per minute. This seep is located at about the same elevation and within the vicinity of the water supply conduit. A travel-time of about 10.5 hours from the source to the seep at 234.1 feet elevation was estimated from the dewatering timeline. During the 3-month shutdown of the water supply conduit, the previously flowing seeps remained dry until precipitation resulted in discharge of about 0.7 gallon per minute at the higher elevation seep, indicating a minor contribution from precipitation to the total seepage discharge. Discharge from the seeps resumed almost immediately coincident with the refilling of the water supply conduit, supporting the hydraulic connection observations during the drainage stage. In addition, during the refilling of the water supply conduit on September 21, 2010, a new seep (I) was observed on the southern embankment. Discharge from this new seep remained relatively constant until it became inaccessible under construction stone from subsequent embankment repairs by the New York City Department of Environmental Protection. Precipitation after the refilling stage of the shutdown seemed to have induced a rise in water levels in the toe wells and an increase in discharge from the seep at 234.1 feet elevation. The post shutdown discharge was less than 12 gallons per minute, compared to a discharge of about 20 gallons per minute before the repairs. The lower discharge rate measured during the period of historically higher discharge rates for the fall season indicates that the repair of the major water supply conduit may have contributed to a reduced discharge from the seeps. There were no definitive responses to the shutdown in any of the wells near the major water supply conduit. The more transmissive deep system of the southern embankment near the major water supply conduit and its associated infrastructure seems to be the preferential flow path for leaking infrastructure. The wells screened in this system showed a response during the deep system anomaly and have some of the highest hydraulic conductivities of the tested wells. All the seeps are in the elevation range of the deep system from approximately the crystalline bedrock surface around 200 feet elevation to the contact between the deep and shallow saturated zones of the reservoir at about 250 feet elevation.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 40.901369445530406° to 40.91924473969948° latitude; -73.87575164367507° to -73.85851786410133° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anthony Chu, Michael L. Noll, William D. Capurso, Robert J. Welk. 2024-02-07. Hydrologic analysis of an earthen embankment dam in southern Westchester County, New York. https://doi.org/10.3133/sir20235123

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗