USGS ScienceSearch

Geology topics

Anthony Chu

Publications and source records attributed to Anthony Chu.

At least 19 recordsLinked to original sources

Accuracy assessment of three-dimensional point cloud data collected with a scanning total station on Shinnecock Nation Tribal lands in Suffolk County, New York

A combined point cloud of about 85.6 million points was collected during 27 scans of a section of the western shoreline along the Shinnecock Peninsula of Suffolk County, New York, to document baseline geospatial conditions during July and October 2022 using a scanning total station. The three-dimensional accuracy of the combined point cloud is assessed to identify potential systematic error sources associated with the surveying equipment and the novel methodology used to collect and field-register (data are oriented and aligned in real time) point cloud data. The accuracy of the combined point cloud was assessed in terms of relative and absolute reference frames. Relative accuracy provides a measure of error within the local coordinate system and is determined by combining the uncertainty associated with the position of the scan station (the point being occupied by the scanning total station during the scan), the uncertainty associated with the position of the network control points, and the uncertainty associated with the laser of the scanning total station. Assessment of the absolute accuracy includes these three potential error sources combined with the uncertainty associated with the geodetic coordinates to which the local control network is referenced. The combined overall relative horizontal and vertical accuracy of the point cloud is 0.0156 and 0.0241 meter, respectively, at the 95 percent confidence level. The combined overall absolute horizontal and vertical accuracy of the point cloud is 0.0598 and 0.0733 meter, respectively, at the 95 percent confidence level.

New York

Hydrologic analysis of an earthen embankment dam in southern Westchester County, New York

In 2001, the New York City Department of Environmental Protection installed 25 wells on the southern embankment of the Hillview Reservoir in Westchester County in an unsuccessful attempt to locate the source of a large seep (seep A) that began flowing continuously in 1999. In 2005, the U.S. Geological Survey began a cooperative study with the NYCDEP to characterize the hydrology of the local groundwater system and identify potential sources of seep A and other seeps on the embankment. At least two groundwater-flow zones—one shallow and the other deep—overlie the bedrock at the Hillview Reservoir in southern Westchester County, New York. Analyses of slug tests of wells drilled into the southern embankment of the reservoir were used to determine the three-dimensional distribution of hydraulic conductivity of the embankment materials. The wells with the minimum and maximum hydraulic conductivity values are in the deep saturated zone on the southern embankment, where hydraulic conductivity ranges from 0.0012 to 2 feet per day. Hydraulic conductivity ranges from 0.0026 to 1 foot per day in the shallow saturated zone and from 0.021 to 0.27 foot per day in the toe of the embankment. A hydraulic conductivity of 0.016 foot per day was determined for one toe well partially screened in the crystalline-bedrock aquifer. In 2005, the U.S. Geological Survey began a cooperative study with New York City Department of Environmental Protection to characterize the local groundwater-flow system and identify potential sources of seeps on the southern embankment of the Hillview Reservoir in southern Westchester County, New York. Long-term hydrologic data indicated that water levels trended downward in 29 of 41 sites, including the reservoir basin that was monitored during the 12-year study period; data from a National Weather Service precipitation gage at Central Park indicated annual precipitation also trended downward during the same 12-year period. Of the seven wells in which water levels trended upward during the study, two of the wells are on the west side of the southern embankment, proximal to a major water supply conduit, whereas the five remaining wells are screened in the toe. These data indicate an increasing hydrostatic pressure within the deep system and the toe of the dam, which could result in future seeps on the southern embankment near these wells. Results of 11 suspended-sediment samples collected from seeps along the southern embankment at 234.1- and 221.6-feet elevation, and another drainage outflow point between 2007 and 2015 indicate a poor correlation between suspended-sediment concentration and discharge. From the flowing seep at 234.1 feet, suspended-sediment concentrations ranged from 1 milligram per liter at a flow of 2.6 gallons per minute (that is, 1 milligram per 0.26 gallons) during March 2008 to 16 milligrams per liter at 12 gallons per minute during July 2014. At about 12 gallons per minute discharge, suspended-sediment concentration from samples collected at that seep during different sampling events, ranged from 3 to 16 milligrams per liter. From the seep at 221.6 feet elevation, the suspended sediment concentration was 2 milligrams per liter at a discharge of 3.4 gallons per minute and 2 milligrams per liter at a discharge of 1.1 gallons per minute. Only one sample was collected at the drainage outflow point, for which the suspended sediment concentration was 2 milligrams per liter at a discharge of 2.4 gallons per minute. Anomalously high-water levels were recorded in deep-system wells between June 5, 2013, and January 14, 2014. The period for the increase and the decrease back to more typical water-level elevations occurred rapidly during a 13-hour period in each instance. The sudden and rapid changes, in addition to the spatial distribution of magnitude of water-level response indicate that leaky water infrastructure was the source of recharge to the affected wells. A major water supply conduit was drained for repairs between July 7 and 10, 2010. The seeps indicated an immediate response and a substantial hydraulic connection to the water supply conduit. Approximately 10.5 hours after the water supply conduit was drained, flow from a seep on the southern embankment decreased from about 20 gallons per minute to less than 1 gallon per minute. This seep is located at about the same elevation and within the vicinity of the water supply conduit. A travel-time of about 10.5 hours from the source to the seep at 234.1 feet elevation was estimated from the dewatering timeline. During the 3-month shutdown of the water supply conduit, the previously flowing seeps remained dry until precipitation resulted in discharge of about 0.7 gallon per minute at the higher elevation seep, indicating a minor contribution from precipitation to the total seepage discharge. Discharge from the seeps resumed almost immediately coincident with the refilling of the water supply conduit, supporting the hydraulic connection observations during the drainage stage. In addition, during the refilling of the water supply conduit on September 21, 2010, a new seep (I) was observed on the southern embankment. Discharge from this new seep remained relatively constant until it became inaccessible under construction stone from subsequent embankment repairs by the New York City Department of Environmental Protection. Precipitation after the refilling stage of the shutdown seemed to have induced a rise in water levels in the toe wells and an increase in discharge from the seep at 234.1 feet elevation. The post shutdown discharge was less than 12 gallons per minute, compared to a discharge of about 20 gallons per minute before the repairs. The lower discharge rate measured during the period of historically higher discharge rates for the fall season indicates that the repair of the major water supply conduit may have contributed to a reduced discharge from the seeps. There were no definitive responses to the shutdown in any of the wells near the major water supply conduit. The more transmissive deep system of the southern embankment near the major water supply conduit and its associated infrastructure seems to be the preferential flow path for leaking infrastructure. The wells screened in this system showed a response during the deep system anomaly and have some of the highest hydraulic conductivities of the tested wells. All the seeps are in the elevation range of the deep system from approximately the crystalline bedrock surface around 200 feet elevation to the contact between the deep and shallow saturated zones of the reservoir at about 250 feet elevation.

New York

Hydrologic effects of leakage from the Catskill Aqueduct on the bedrock-aquifer system near High Falls, New York, November 2019–January 2020

Historical observations by the New York City Department of Environmental Protection (NYCDEP) indicate that the Rondout pressure tunnel has been leaking in the vicinity of the hamlet of High Falls, New York. In the 74 days from November 11, 2019, to January 23, 2020, NYCDEP shut down and partially dewatered the pressure tunnel for inspection and repairs. On November 5–7, 2019 (during normal tunnel operations), and on January 21–22, 2020 (when the tunnel was shut down), the U.S. Geological Survey used a network of 31 groundwater wells to collect water-level elevations and determine the potentiometric surface of the bedrock aquifer adjacent to the Rondout pressure tunnel. When the tunnel was fully pressurized during normal operations, water levels indicated a two-mile-long groundwater mound which trended northeastward, approximately along the regional strike of the bedrock units. The mound ranged in elevation from 250 to 300 feet (ft) above the North American Vertical Datum of 1988 and extended from 1,500 ft southwest of a suspected leak at the Rondout pressure tunnel to about 8,500 ft northeast of the possible leak. During the 74-day shutdown, during which the aqueduct was nonoperational, this groundwater mound decreased in magnitude and extent as it reverted to equilibrium conditions. This resulted in a flattening of the potentiometric surface, represented by two remnant groundwater plateaus. Water-level differences were calculated for wells that may be affected by potential tunnel leakage to determine the influence on the local bedrock aquifer. The five largest water-level differences (77, 61, 49, 42, and 41 ft) occurred in wells that were generally aligned with the northeastward trend of regional bedrock strike; these wells may penetrate the karstic Helderberg Group bedrock unit. Near the suspected tunnel leak, the Helderberg Group overlies the Binnewater Sandstone and the High Falls Shale, both of which produced substantial groundwater inflows during the construction of the Rondout pressure tunnel. Water levels in wells penetrating the Shawangunk Formation just east of Rondout Creek, where the unit is in contact with the High Falls Shale, and in wells penetrating the Esopus Shale, which is adjacent to the Helderberg Group and northwest of the tunnel leak, may be affected by tunnel leakage. It is unclear if water levels in a well 9,000 ft northwest of the suspected tunnel leak are influenced by the tunnel leakage, by another source of artificial recharge, or by both. This well penetrates the Onondaga Limestone in the northwestern part of the study area. An unconsolidated aquifer composed of stratified gravel, sand, silt, and clay overlies the limestone bedrock in this part of study area―additional study is required to determine if this unconsolidated aquifer is affected by tunnel leakage.

New York

Slug-test analysis of selected wells at an earthen dam site in southern Westchester County, New York

In 2005, the U.S. Geological Survey began a cooperative study with the New York City Department of Environmental Protection to characterize the local groundwater-flow system and identify potential sources of seeps on the southern embankment of the Hillview Reservoir in southern Westchester County, New York. The earthen embankment comprises low-permeability glacial clays that were excavated from the site and rest on a veneer of low-permeability glacial deposits that overlie crystalline bedrock. At least two groundwater-flow zones—one shallow and the other deep—overlie the bedrock at the reservoir. As part of the study, slug-test data from 38 screened wells were analyzed to determine the hydraulic conductivity of the sediments in the groundwater-flow zones. Slug-test data were collected from 12 wells at the Hillview Reservoir during August 2007 and from 25 wells at the reservoir and 1 monitoring well south of the reservoir in northern Bronx County in June 2012. Hydraulic conductivity values at the reservoir ranged from 0.0012 to 2 feet per day. On the southern embankment, hydraulic conductivity ranged from 0.0026 to 1 foot per day for wells screened in the shallow saturated zone; 0.0012 to 2 feet per day for wells screened in the deep saturated zone; and 0.021 to 0.27 foot per day for wells screened in the toe of the southern embankment, where the deep and shallow saturated zones coalesce. A hydraulic conductivity of 0.016 foot per day was determined for a well partially screened in the crystalline-bedrock aquifer, which potentially indicates an interconnection of transmissive fractures near the bedrock surface. The results of four slug-out tests are also included in this report to quality assure the hydraulic conductivity estimates from the slug-in test analysis. The results of the four slug-out tests were within 8 percent of slug-in test results, with an average of less than 2 percent.

New York

Groundwater-level data from an earthen dam site in southern Westchester County, New York

In 2005, the U.S. Geological Survey began a cooperative study with New York City Department of Environmental Protection to characterize the local groundwater-flow system and identify potential sources of seeps on the southern embankment of the Hillview Reservoir in Westchester County, New York. Groundwater levels were collected at 49 wells at Hillview Reservoir, and 1 well in northern Bronx County, from April 2005 through November 2016. Groundwater levels were measured discretely with a chalked steel or electric tape, or continuously with a digital pressure transducer, or both, in accordance with U.S. Geological Survey groundwatermeasurement standards. These groundwater-level data were plotted as time series and are presented in this report as hydrographs. Twenty-eight of the 50 hydrographs have continuous record and discrete field groundwater-level measurements, 22 of the hydrographs contain only discrete measurements.

New York

Water-quality data from an earthen dam site in southern Westchester County, New York, 2015

The U.S. Geological Survey, in cooperation with the New York City Department of Environmental Protection, sampled 37 sites in the reservoir area for nutrients, major ions, metals, pesticides and their degradates, volatile organic compounds, temperature, pH, and specific conductance during fall 2015. Data collection was done to characterize the local groundwater-flow system and identify potential sources of seeps from the southern embankment at the Hillview Reservoir. Water-quality samples were collected in accordance with standard U.S. Geological Survey methods at 37 sites in and adjacent to Hillview Reservoir. These 37 sites were sampled to determine (1) baseline water-quality conditions of the saturated, low-permeability sediments that compose the earthen embankment that surrounds the reservoir, (2) water-quality conditions in the southwestern part of the study area in relation to the seeps on the embankment, and (3) temporal variation of water-quality conditions between 2006 and 2015 (not included in this report). The physical parameters and the results of the water-quality analysis from the 37 sites are included in this report and can be downloaded from the U.S. Geological Survey National Water Information System website.

New York

Detecting temporal change in land-surface altitude using robotic land-surveying techniques and geographic information system applications at an earthen dam site in Southern Westchester County, New York

In 2005, the U.S. Geological Survey began a cooperative study with New York City Department of Environmental Protection to characterize the local groundwater-flow system and identify potential sources of seeps on the southern embankment at the Hillview Reservoir in southern Westchester County, New York. Monthly site inspections at the reservoir indicated an approximately 90-square-foot depression in the land surface directly upslope from a seep that has episodically flowed since 2007. In July 2008, the U.S. Geological Survey surveyed the topography of land surface in this depression area by collecting high-accuracy (resolution less than 1 inch) measurements. A point of origin was established for the topographic survey by using differentially corrected positional data collected by a global navigation satellite system. Eleven points were surveyed along the edge of the depression area and at arbitrary locations within the depression area by using robotic land-surveying techniques. The points were surveyed again in March 2012 to evaluate temporal changes in land-surface altitude. Survey measurements of the depression area indicated that the land-surface altitude at 8 of the 11 points decreased beyond the accepted measurement uncertainty during the 44 months from July 2008 to March 2012. Two additional control points were established at stable locations along Hillview Avenue, which runs parallel to the embankment. These points were measured during the July 2008 survey and measured again during the March 2012 survey to evaluate the relative accuracy of the altitude measurements. The relative horizontal and vertical (altitude) accuracies of the 11 topographic measurements collected in March 2012 were ±0.098 and ±0.060 feet (ft), respectively. Changes in topography at 8 of the 11 points ranged from 0.09 to 0.63 ft and topography remained constant, or within the measurement uncertainty, for 3 of the 11 points. Two cross sections were constructed through the depression area by using land-surface altitude data that were interpolated from positional data collected during the two topographic surveys. Cross section A–A′ was approximately 8.5 ft long and consisted of three surveyed points that trended north to south across the depression. Land-surface altitude change decreased along the entire north-south trending cross section during the 44 months, and ranged from 0.2 to more than 0.6 ft. In general, greater land-surface altitude change was measured north of the midpoint as compared to south of the midpoint of the cross section. Cross section B–B′ was 18 ft long and consisted of six surveyed points that trended east to west across the depression. Land-surface altitude change generally decreased or remained constant along the east-west trending cross section during the 44 months and ranged from 0.0 to 0.3 ft. Volume change of the depression area was calculated by using a three-dimensional geographic information system utility that subtracts interpolated surfaces. The results indicated a net volume loss of approximately 38 ±5 cubic feet of material from the depression area during the 44 months.

New York

Delineation of fractures, foliation, and groundwater of the bedrock at a geothermal feasibility site on Roosevelt Island, New York County, New York

Advanced borehole-geophysical methods were used to investigate the hydrogeology of the crystalline bedrock in three boreholes on Roosevelt Island, New York County, New York. Cornell University was evaluating the feasibility of using geothermal energy for a future campus at the site. The borehole-logging techniques were used to delineate bedrock fractures, foliation, and groundwater-flow zones of the Fordham Gneiss in test boreholes at the site. Three fracture populations dominated by small (0.04 in or less) fractures were delineated in the three boreholes. A sub-horizontal population with low to moderate dipping fractures, a northeast dipping population with moderate to high angle fractures, and a small northwest dipping high angle fracture population. One large southwest dipping transmissive fracture underlies the entire study area with a mean dip azimuth of 235º southwest and a dip angle of 31º (N325ºW 31ºSW). The mean foliation dip azimuth was 296º northwest with a mean dip angle of 73º (N26ºE 73ºNW). Groundwater appears to flow through a network of fractures dominated by a large fracture underlying the site that is affected by tidal variations from the nearby East River. The total number of fractures penetrated by each borehole was 95, 63, and 68, with fracture indices of 0.26, 0.20, and 0.20 in GT-1 (NY292), GT-2 (NY293), and GT-3 (NY294), respectively. Aquifer test data indicate the specific capacity of boreholes GT-1 (NY292), GT-2 (NY293), and GT-3 (NY294) was 1.9, 1.5, and 3.7 gal/min/ft, respectively. The large contribution of flow from the leaking casing in borehole GT-3 (NY294) caused the doubling in specific capacity compared to boreholes GT-1 (NY292) and GT-2 (NY293). The transmissivities of the large fracture intersected by the three boreholes tested (GT-1, GT-2, and GT-3), calculated from aquifer-test analyses of time-drawdown data and flowmeter differencing, were 133, 124, and 65 feet squared per day (ft2/d), respectively. Gringarten analysis indicated the large fracture intersects a low transmissivity boundary or distant fracture network with an average transmissivity of 69 ft2/d, this distant hydraulic boundary averages about 200 ft away from boreholes GT-1 and GT-2. Field measurements of specific conductance of the three boreholes under ambient conditions at the site indicate an increase in conductivity toward the southwest part of the site. Specific conductance was 5, 6, and 23 millisiemens per centimeter (mS/cm) in boreholes GT-2, GT-3, and GT-1, respectively. Three borehole radar reflection logs collected at each of the boreholes indicated increased penetration with depth and the large fracture intersecting all three boreholes was imaged as far as 80 ft from the boreholes. A borehole radar attenuation tomogram from GT-1 to GT-2 indicated the large fracture intersected by the boreholes extends between the boreholes with a low angle southwest dip.

New York

Geophysical and hydrologic analysis of an earthen dam site in southern Westchester County, New York

Ninety percent of the drinking water for New York City passes through the Hillview Reservoir facility in the City of Yonkers, Westchester County, New York. In the past, several seeps located downslope from the reservoir have flowed out from the side of the steepest slope at the southern end of the earthen embankment. One seep that has been flowing continuously was discovered during an inspection of the embankment in 1999. Efforts were made in 2001 to locate the potential sources of the continuous flowing seep. In 2005, the U.S. Geological Survey, in cooperation with the New York City Department of Environmental Protection, began a cooperative study to investigate the relevant hydrogeologic framework to characterize the local groundwater-flow system and to determine possible sources of the seeps. The two agencies used hydrologic and surface geophysical techniques to assess the earthen embankment of the Hillview Reservoir. Between April 1, 2005 and March 1, 2008, water levels were measured manually each month at 46 wells surrounding the reservoir, and flow was measured monthly at three of the five seeps on the embankment. Water levels were measured hourly in the East Basin of the reservoir, at 24 of 46 wells, and discharge was measured hourly at two of the five seeps. Slug tests were performed at 16 wells to determine the hydraulic conductivity of the geologic material surrounding the screened zone. Estimated hydraulic conductivities for 25 wells on the southern embankment ranged from 0.0063 to 1.2 feet per day and averaged 0.17 foot per day. The two-dimensional resistivity surveys indicate a subsurface mound of electrically conductive material (low-resistivity zone) beneath the terrace area (top of dam) surrounding the reservoir with a distinct elevation increase closer to the crest. Two-dimensional shear wave velocity surveys indicate a similar structure of the high shear wave velocity materials (high-velocity zone), increasing in elevation toward the crest and decreasing toward the reservoir and toward the northern part of the study area. Water-quality samples collected from 12 wells, downtake chamber 1 of the reservoir, and two seeps detected the presence of arsenic, toluene, and two trihalomethanes. Water-quality samples collected at the two seeps detected fluoride, indicating a connection with reservoir water. Shallow wells on the southern embankment exhibited the largest seasonal water-level fluctuations ranging between 6 feet and 12 feet. The embankment is constructed from reworked low-permeability glacial deposits at the site. Water-level responses in observation wells within the embankment indicate that there is a shallow (approximately the upper 45 feet of the embankment) and a deep water-bearing unit within the embankment with a large downward vertical gradient between the shallow and deep water-bearing units. Precipitation strongly affected water levels in shallow wells, whereas the basin appears to be the main control on water levels in the deep wells. Seeps on the embankment slope appear to be caused by above-average precipitation that increases water levels in the shallow water-bearing unit, but does not easily recharge the deep water-bearing unit. Based on the data that have been analyzed, source water to the seeps appears to be primarily groundwater and, to a lesser extent, water from the East Basin of the reservoir.

New York

Delineation of fractures, foliation, and groundwater-flow zones of the bedrock at the Harlem River Tunnel in northern New York County, New York

Advanced borehole-geophysical methods were used to investigate the hydrogeology of the crystalline bedrock in 36 boreholes on the northernmost part of New York County, New York, for the construction of a utilities tunnel beneath the Harlem River. The borehole-logging techniques were used to delineate bedrock fractures, foliation, and groundwater-flow zones in test boreholes at the site. Fracture indexes of the deep boreholes ranged from 0.65 to 0.76 per foot. Most of the fracture populations had either northwest to southwest or east to southeast dip azimuths with moderate dip angles. The mean foliation dip azimuth ranged from 100º to 124º southeast with dip angles of 52º to 60º. Groundwater appears to flow through an interconnected network of fractures that are affected by tidal variations from the nearby Harlem River and tunnel construction dewatering operations. The transmissivities of the 3 boreholes tested (USGS-1, USGS-3, and USGS-4), calculated from specific capacity data, were 2, 48, and 30 feet squared per day (ft 2 /d), respectively. The highest transmissivities were observed in wells north and west of the secant ring. Three borehole-radar velocity tomograms were collected. In the USGS-1 and USGS-4 velocity tomogram there are two areas of low radar velocity. The first is at the top of the tomogram and runs from 105 ft below land surface (BLS) at USGS-4 and extends to 125 ft BLS at USGS-1, the second area is centered at a depth of 150 ft BLS at USGS-1 and 135 to 150 ft BLS at USGS-4. Field measurements of specific conductance of 14 boreholes under ambient conditions at the site indicate an increase in conductivity toward the southwest part of the site (nearest the Harlem River). Specific conductance ranged from 107 microsiemens per centimeter (μS/cm) (borehole 63C) to 11,000 μS/cm (borehole 79B). The secant boreholes had the highest specific conductance.

New York

Preliminary analysis of the hydrologic effects of temporary shutdowns of the Rondout-West Branch Water Tunnel on the groundwater-flow system in Wawarsing, New York

Flooding of streets and residential basements, and bacterial contamination of private-supply wells with Escherichia coli (E. coli) are recurring problems in the Rondout Valley near the Town of Wawarsing, Ulster County, New York. Leakage from the Rondout-West Branch (RWB) Water Tunnel and above-normal precipitation have been suspected of causing elevated groundwater levels and basement flooding. The hydrology of a 12-square-mile study area within the Town of Wawarsing was studied during 2008-10. A network of 41 wells (23 unconsolidated-aquifer and 18 bedrock wells) and 2 surface-water sites was used to monitor the hydrologic effects of four RWB Water Tunnel shutdowns. The study area is underlain by a sequence of northeast-trending sedimentary rocks that include limestone, shale, and sandstone. The bedrock contains dissolution features, fractures, and faults. Inflows that ranged from less than 1 to more than 9,000 gallons per minute from the fractured bedrock were documented during construction of the 13.5-foot-diameter RWB Water Tunnel through the sedimentary-rock sequence 710 feet (ft) beneath the study-area valley. Glacial sediments infill the valley above the bedrock sequence and consist of clay, silt, sand, and gravel. The groundwater-flow system in the valley consists of both fractured-rock and unconsolidated aquifers. Water levels in both the bedrock and unconsolidated aquifers respond to variations in seasonal precipitation. During the past 9 years (2002-10), annual precipitation at Central Park, N.Y., has exceeded the 141-year mean. Potentiometric-surface maps indicate that groundwater in the bedrock flows from the surrounding hills on the east and west sides of the valley toward the center of the valley, and ultimately toward the northeast. On average, water levels in the bedrock aquifer had seasonal differences of 5.3 ft. Analysis of hydrographs of bedrock wells indicates that many of these wells are affected by the RWB Tunnel leakage. Tunnel-leakage influences (water level and temperature changes) in the bedrock aquifer were measured at distances up to 7,000 ft from the RWB Tunnel. Water levels in the bedrock changed as much as 12 ft within 0.5 hour during tunnel shutdowns. Nine of the 10 wells that responded to the shutdowns showed a water-level response of 5 ft or greater. Changes in water levels ranged from 1.5 to 12 ft, with tunnel-leakage influence delay times ranging from 0.5 to 60 hours. Many of the longest tunnel-influence delay times and smallest water-level changes were in wells located closest to the tunnel in shale. Tunnel-influence response of the bedrock aquifer is consistent with its preliminary characterization as an anisotropic aquifer with greater transmissivity along bedding strike than across bedding strike. This tunnel-influence response is also consistent with the likely presence of discrete high-transmissivity networks along fractured limestone beds that have undergone dissolution. A lack of bedrock observation wells in half of the study area hampered a more thorough analysis of the extent of leakage from the RWB Tunnel in the study area. On average, water levels in the unconsolidated aquifer had a seasonal difference of 5.0 ft. Some unconsolidated-aquifer wells indicated water-level changes due to tunnel leakage. The locations of unconsolidated-aquifer wells with measurable water-level changes due to tunnel leakage correlated with those in the bedrock. Water levels in the unconsolidated aquifer changed as much as 2.5 ft within 18 hours of tunnel shutdowns, but water-level changes in some unconsolidated-aquifer wells were smaller or nonexistent.

New York

Preliminary assessment of water chemistry related to groundwater flooding in Wawarsing, New York, 2009-11

Water-quality samples collected in an area prone to groundwater flooding in Wawarsing, New York, were analyzed and assessed to better understand the hydrologic system and to aid in the assessment of contributing water sources. Above average rainfall over the past decade, and the presence of a pressurized water tunnel that passes about 700 feet beneath Wawarsing, could both contribute to groundwater flooding. Water samples were collected from surface-water bodies, springs, and wells and analyzed for major and trace inorganic constituents, dissolved gases, age tracers, and stable isotopes. Distinct differences in chemistry exist between tunnel water and groundwater in unconsolidated deposits and in bedrock, and among groundwater samples collected from some bedrock wells during high head pressure and low head pressure of the Rondout-West Branch Tunnel. Samples from bedrock wells generally had relatively higher concentrations of sulfate (SO 4 2- ), strontium (Sr), barium (Ba), and lower concentrations of calcium (Ca) and bicarbonate (HCO 3 - ), as compared to unconsolidated wells. Differences in stable-isotope ratios among oxygen-18 to oxygen-16 (δ 18 O), hydrogen-2 to hydrogen-1 (δ 2 H), sulfur-34 to sulfur-32(δ 34 S) of SO 4 2- , Sr-87 to Sr-86 ( 87 Sr/ 86 Sr), and C-13 to C-12 (δ 13 C) of dissolved inorganic carbon (DIC) indicate a potential for distinguishing water in the Delaware-West Branch Tunnel from native groundwater. For example, 87 Sr/ 86 Sr ratios were more depleted in groundwater samples from most bedrock wells, as compared to samples from surface-water sources, springs, and wells screened in unconsolidated deposits in the study area. Age-tracer data provided useful information on pathways of the groundwater-flow system, but were limited by inherent problems with dissolved gases in bedrock wells. The sulfur hexafluoride (SF 6 ) and (or) chlorofluorocarbons (CFCs) apparent recharge years of most water samples from wells screened in unconsolidated deposits and springs ranged from 2003 to 2010 (current) and indicate short flow paths from the point of groundwater recharge. All but three of the samples from bedrock wells had interference problems with dissolved gases, mainly caused by excess air from degassing of hydrogen sulfide and methane. The SF 6 and (or) CFC apparent recharge years of samples from three of the bedrock wells ranged from the 1940s to the early 2000s; the sample with the early 2000s recharge year was from a flowing artesian well that was chemically similar to water samples collected at the influent to the tunnel at Rondout Reservoir and the most hydraulically responsive to water tunnel pressure compared to other bedrock wells. Data described in this report can be used, together with hydrogeologic data, to improve the understanding of source waters and groundwater-flow patterns and pathways, and to help assess the mixing of different source waters in water samples. Differences in stable isotope ratios, major and trace constituent concentrations, saturation indexes, tritium concentrations, and apparent groundwater ages will be used to estimate the proportion of water that originates from Rondout-West Branch Tunnel leakage.

New York

Hydrogeology of the Lloyd aquifer on Long Island, New York— A brief summary of USGS investigations

The four counties of Long Island (fig. 1) are underlain by a wedge-shaped sequence of unconsolidated deposits of Late Cretaceous and Pleistocene age that lie unconformably on crystalline bedrock (fig. 2). A saprolitic (weathered bedrock) zone 20 to 100 ft thick overlies the bedrock in most areas. The sequence of unconsolidated deposits thickens to the south and southeast by about 65 to 100 feet per mile and contains Long Island's fresh ground water. Long Island's ground-water system consists of four main aquifers-the upper glacial, the Jameco, the Magothy, and the Lloyd. The Lloyd aquifer underlies nearly all of Long Island (fig. 3), but pumpage from the Lloyd has been limited to the northern and southern coastal areas of the island by the New York State Department of Environmental Conservation since about 1955 (Garber, 1986). Coastal areas are exempt where the Lloyd is the only source of potable water. The former Jamaica Water Supply Corporation (now owned by New York City) is a noted exception withdrawing as much as 6 million gallons per day (Mgal/d) since the mid-1930s from the Lloyd in central Queens County. This paper: (1) provides a brief history of U.S. Geological Survey (USGS) studies that provided significant data on the Lloyd, (2) summarizes the hydraulic characteristics of the Lloyd as reported in those studies, and (3) describes present-day monitoring of the Lloyd by the USGS.

New York

Delineation of faults, fractures, foliation, and ground-water-flow zones in fractured-rock, on the southern part of Manhattan, New York, through use of advanced borehole-geophysical techniques

Advanced borehole-geophysical techniques were used to assess the geohydrology of crystalline bedrock in 20 boreholes on the southern part of Manhattan Island, N.Y., in preparation for construction of a third water tunnel for New York City. The borehole-logging techniques included natural gamma, single-point resistance, short-normal resistivity, mechanical and acoustic caliper, magnetic susceptibility, borehole-fluid temperature and resistivity, borehole-fluid specific conductance, dissolved oxygen, pH, redox, heatpulse flowmeter (at selected boreholes), borehole deviation, acoustic and optical televiewer, and borehole radar (at selected boreholes). Hydraulic head and specific-capacity test data were collected from 29 boreholes. The boreholes penetrated gneiss, schist, and other crystalline bedrock that has an overall southwest to northwest-dipping foliation. Most of the fractures penetrated are nearly horizontal or have moderate- to high-angle northwest or eastward dip azimuths. Foliation dip within the potential tunnel-construction zone is northwestward and southeastward in the proposed North Water-Tunnel, northwestward to southwestward in the proposed Midtown Water-Tunnel, and northwestward to westward dipping in the proposed South Water-Tunnel. Fracture population dip azimuths are variable. Heat-pulse flowmeter logs obtained under pumping and nonpumping (ambient) conditions, together with other geophysical logs, indicate transmissive fracture zones in each borehole. The 60-megahertz directional borehole-radar logs delineated the location and orientation of several radar reflectors that did not intersect the projection of the borehole. Fracture indexes range from 0.12 to 0.93 fractures per foot of borehole. Analysis of specific-capacity tests from each borehole indicated that transmissivity ranges from 2 to 459 feet squared per day; the highest transmissivity is at the Midtown Water-Tunnel borehole (E35ST-D).

Open-File Report

Use of advanced borehole geophysical techniques to delineate fractured-rock ground-water flow and fractures along water-tunnel facilities in northern Queens County, New York

Advanced borehole geophysical methods were used to assess the geohydrology of crystalline bedrock along the course of a new water tunnel for New York City. The logging methods include natural gamma, spontaneous potential, single-point resistance, mechanical and acoustic caliper, focused electromagnetic induction, electromagnetic resistivity, magnetic susceptibility, borehole-fluid temperature and conductance, differential temperature, heat-pulse flowmeter, acoustic televiewer, borehole deviation, optical televiewer, and borehole radar. Integrated interpretation of the geophysical logs from an 825-foot borehole (1) provided information on the extent, orientation, and structure (foliation and fractures) within the entire borehole, including intensely fractured intervals from which core recovery may be poor; (2) delineated transmissive fracture zones intersected by the borehole and provided estimates of their transmissivity and hydraulic head; and (3) enabled mapping of the location and orientation of structures at distances as much as 100 ft from the borehole. Analyses of the borehole-wall image and the geophysical logs from the borehole on Crescent Street, in northern Queens County, are presented here to illustrate the application of the methods. The borehole penetrates gneiss and other crystalline bedrock that has predominantly southeastward dipping foliation and nearly horizontal and southeastward-dipping fractures. The heat-pulse flowmeter logs obtained under pumping and nonpumping conditions, together with the other geophysical logs, indicate five transmissive fracture zones. More than 90 percent of the open-hole transmissivity is associated with a fracture zone 272 feet BLS (below land surface). A transmissive zone at 787 feet BLS that consists of nearly parallel fractures lies within the projected tunnel path; here the hydraulic head is 12 to 15 feet lower than that of transmissive zones above the 315-foot depth. The 60-megahertz directional borehole radar logs indicate the location and orientation of two closely spaced radar reflectors that would intersect the projection of the borehole below its drilled depth. Subsequent excavation of the tunnel past the borehole allowed comparison of the log analysis with conditions observed in the tunnel. The tunnel was found to intersect gneiss with southeastward dipping foliation; many nearly horizontal fractures; and a southeastward dipping fracture zone whose location, character, and orientation was consistent with that of the mapped radar reflectors. The fracture zone produced inflow to the tunnel at a rate of 50 to 100 gallons per minute. All conditions indicated by the logging methods were consistent with those observed within the tunnel.

New York