USGS ScienceSearch

USGS · sir20075237

Evaluation of Approaches for Managing Nitrate Loading from On-Site Wastewater Systems near La Pine, Oregon

Abstract

This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the Oregon Department of Environmental Quality and Deschutes County, to develop a better understanding of the effects of nitrogen from on-site wastewater disposal systems on the quality of ground water near La Pine in southern Deschutes County and northern Klamath County, Oregon. Simulation models were used to test the conceptual understanding of the system and were coupled with optimization methods to develop the Nitrate Loading Management Model, a decision-support tool that can be used to efficiently evaluate alternative approaches for managing nitrate loading from on-site wastewater systems. The conceptual model of the system is based on geologic, hydrologic, and geochemical data collected for this study, as well as previous hydrogeologic and water quality studies and field testing of on-site wastewater systems in the area by other agencies. On-site wastewater systems are the only significant source of anthropogenic nitrogen to shallow ground water in the study area. Between 1960 and 2005 estimated nitrate loading from on-site wastewater systems increased from 3,900 to 91,000 pounds of nitrogen per year. When all remaining lots are developed (in 2019 at current building rates), nitrate loading is projected to reach nearly 150,000 pounds of nitrogen per year. Low recharge rates (2-3 inches per year) and ground-water flow velocities generally have limited the extent of nitrate occurrence to discrete plumes within 20-30 feet of the water table; however, hydraulic-gradient and age data indicate that, given sufficient time and additional loading, nitrate will migrate to depths where many domestic wells currently obtain water. In 2000, nitrate concentrations greater than 4 milligrams nitrogen per liter (mg N/L) were detected in 10 percent of domestic wells sampled by Oregon Department of Environmental Quality. Numerical simulation models were constructed at transect (2.4 square miles) and study-area (247 square miles) scales to test the conceptual model and evaluate processes controlling nitrate concentrations in ground water and potential ground-water discharge of nitrate to streams. Simulation of water-quality conditions for a projected future build-out (base) scenario in which all existing lots are developed using conventional on-site wastewater systems indicates that, at equilibrium, average nitrate concentrations near the water table will exceed 10 mg N/L over areas totaling 9,400 acres. Other scenarios were simulated where future nitrate loading was reduced using advanced treatment on-site systems and a development transfer program. Seven other scenarios were simulated with total nitrate loading reductions ranging from 15 to 94 percent; simulated reductions in the area where average nitrate concentrations near the water table exceed 10 mg N/L range from 22 to 99 percent at equilibrium. Simulations also show that the ground-water system responds slowly to changes in nitrate loading due to low recharge rates and ground-water flow velocity. Consequently, reductions in nitrate loading will not immediately reduce average nitrate concentrations and the average concentration in the aquifer will continue to increase for 25-50 years depending on the level and timing of loading reduction. The capacity of the ground-water system to receive on-site wastewater system effluent, which is related to the density of homes, presence of upgradient residential development, ground-water recharge rate, ground-water flow velocity, and thickness of the oxic part of the aquifer, varies within the study area. Optimization capability was added to the study-area simulation model and the combined simulation-optimization model was used to evaluate alternative approaches to management of nitrate loading from on-site wastewater systems to the shallow alluvial aquifer. The Nitrate Loading Management Model (NLMM) was formulated to find the minimum red

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 43.5° to 44° latitude; -121.75° to -121.25° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David S. Morgan, Stephen R. Hinkle, Rodney J. Weick. 2007. Evaluation of Approaches for Managing Nitrate Loading from On-Site Wastewater Systems near La Pine, Oregon. https://doi.org/10.3133/sir20075237

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Monitoring recreation on federally managed lands and waters—Aspects of visitor use

Federally managed public lands and waters receive around 1 billion recreational visits each year. Data on these visitors can aid in guiding policy decisions, managing resources effectively, and communicating the economic contributions of lands and waters. This report explores the methods used by agencies to collect data on aspects of recreational visitor use to Federal lands and waters (apart from visitation numbers, which are the focus of a companion publication). Aspects of recreational visitor use include visitor demographics, recreational activity participation, visitor satisfaction, visitor attitudes and experiences, trip characteristics, and economic contributions. We review practices used to understand aspects of visitor use across seven Federal agencies, revealing similarities such as the use of visitor intercept surveys and coverage of similar topic areas, and differences in how survey programs are operationalized and how specific questions on visitor surveys are worded. We also evaluate emerging technologies, such as geolocated social media and mobile device location data, for their potential to aid in understanding aspects of visitor use. This report concludes with potential opportunities to enhance data collection and coordination, ensuring cost-effective data collection and informed decision making.

Scientific Investigations Report

Evaluation of best management practices at an edge-of-field site in the Eagle Creek watershed, Ohio, 2012–20

In 2010, the U.S. Geological Survey worked in partnership with the Great Lakes Restoration Initiative and the Natural Resources Conservation Service to identify farm fields in priority watersheds—watersheds critically important to Great Lake health. Intensive best management practices were implemented in five States to test the efficacy of best management practices, also referred to as agricultural conservation practices, to reduce sediment and nutrient runoff on agricultural fields. These fields were chosen as representatives of the priority watersheds because their farming practices and geographical conditions were common among farms in those watersheds. A farm site located near Findlay, Ohio, in the Eagle Creek watershed used two conservation practices, cover crop (Natural Resources Conservation Service practice standard 340) and variable rate technology (VRT; Natural Resources Conservation Service practice standard 590), which represent common practices in the Maumee priority watershed. This study monitored surface runoff and subsurface tile runoff at the Eagle Creek watershed site. The effects of cover crop and VRT nutrient application on sediment and nutrient runoff were assessed from October 2012 to September 2020. Cover crops were applied in fall of 2016, 2017, and 2018, coinciding with VRT applications. The following parameters were analyzed as part of the study: runoff discharge; peak discharge; and concentrations and loads of total phosphorus, particulate phosphorus, dissolved reactive phosphorus, and suspended sediment. High peak runoff events disproportionally affected nutrient concentrations and loads in runoff. A threshold of the 85th percentile of the peak discharge was chosen to assess the effect of cover crop and VRT nutrient application on nutrient mitigation at each gage. Runoff events below the 85th percentile were considered small, and runoff events over the 85th percentile were considered large. Concentrations from collected water-quality samples were used for the analysis; estimated concentrations were excluded from the statistical evaluation. All surface runoff parameters during small runoff events, except surface runoff volume, were significantly lower in the period with cover crops and VRT implementation. Contrarily, subsurface runoff parameters during small events were not statistically different between the periods with and without cover crops and VRT implementation. Surface and subsurface parameters during large events were also not statistically different between the periods with and without cover crops and VRT implementation. These results indicate cover crops and VRT may improve water quality during small runoff events, but additional best management practices that mitigate large runoff events may lead to greater water-quality improvement given the contribution of large events to overall losses.

Ohio

Continuous monitoring and temporal variability of fluorescence of dissolved organic matter in karst groundwater of the Edwards aquifer, south-central Texas, 2019–24

Widespread urbanization on the Edwards aquifer recharge zone in south-central Texas has prompted the development of new approaches and tools for evaluating the current and future status of water quality in the San Antonio and Barton Springs segments of the Edwards aquifer. The U.S. Geological Survey, in cooperation with the San Antonio Water System and the City of Austin, applied continuous monitoring of fluorescence of dissolved organic matter (fDOM) to characterize the sources and transport of dissolved organic matter and associated constituents in the Edwards aquifer. Continuous fDOM time-series data were adjusted using empirically derived temperature, turbidity, and inner-filter-effect correction factors prior to analysis and interpretation. Fully corrected fDOM time-series data from the study sites were evaluated for short- and long-term temporal variability in fDOM in the context of the hydrologic and climatic conditions that occurred during the 5-year study period to understand vulnerability of the aquifer to potential contaminants in recharge. Study results indicate that fDOM is an effective proxy for dissolved organic carbon that, in turn, is indicative of the influx of recent surface water and associated contaminants, and thus, aquifer vulnerability to those contaminants. Although other continuously monitored water-quality parameters provide insights into changes in water quality in response to varying hydrologic conditions, the quantitative relation between fDOM and dissolved organic carbon directly indicates the timing and magnitude of pulses of organic constituents derived from the land surface, whereas other water-quality parameters do not.

Texas