Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota--Analysis of thermal data and nonisothermal modeling of short-term test cycles

Abstract

In May 1980, the University of Minnesota began a project to evaluate the feasibility of storing heated water (150 degrees Celsius) in the Franconia-Ironton Galesville aquifer (183 to 245 meters below land surface) and later recovering it for space heating. The University's steam-generation facilities supplied high-temperature water for injection. The Aquifer Thermal-Energy Storage system is a doublet-well design in which the injection-withdrawal wells are spaced approximately 250 meters apart. Water was pumped from one of the wells through a heat exchanger, where heat was added or removed. This water was then injected back into the aquifer through the other well. Four short-term test cycles were completed. Each cycle consisted of approximately equal durations of injection and withdrawal ranging from 5.25 to 8.01 days. Equal rates of injection and withdrawal, ranging from 17.4 to 18.6 liters per second, were maintained for each short-term test cycle. Average injection temperatures ranged from 88.5 to 117.9 degrees Celsius. Temperature graphs for selected depths at individual observation wells indicate that the Ironton and Galesville Sandstones received and stored more thermal energy than the upper part of the Franconia Formation. Clogging of the Ironton Sandstone was possibly due to precipitation of calcium carbonate or movement of fine-grain material or both. Vertical-profile plots indicate that the effects of buoyancy flow were small within the aquifer. A three-dimensional, anisotropic, nonisothermal, ground-water-flow, and thermal-energy-transport model was constructed to simulate the four short-term test cycles. The model was used to simulate the entire short-term testing period of approximately 400 days. The only model properties varied during model calibration were longitudinal and transverse thermal dispersivities, which, for final calibration, were simulated as 3.3 and 0.33 meters, respectively. The model was calibrated by comparing model-computed results to (1) measured temperatures at selected altitudes in four observation wells, (2) measured temperatures at the production well, and (3) calculated thermal efficiencies of the aquifer. Model-computed withdrawal-water temperatures were within an average of about 3 percent of measured values and model-computed aquifer-thermal efficiencies were within an average of about 5 percent of calculated values for the short-term test cycles. These data indicate that the model accurately simulated thermal-energy storage within the Franconia-Ironton-Galesville aquifer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert T. Miller, G. N. Delin. 2002. Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota--Analysis of thermal data and nonisothermal modeling of short-term test cycles. https://doi.org/10.3133/pp1530b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Resurvey of the Marble Canyon and Bridge Canyon dam sites in Grand Canyon National Park—Changes in sediment storage and evidence supporting the occurrence of bedrock incision through the mid-20th century

The Bureau of Reclamation developed an extensive plan for a network of dams, water tunnels, and hydropower plants in and around Grand Canyon, Arizona, in the 1940s through 1960s. The two largest of these planned dams were the Marble Canyon and Bridge Canyon Dams on the Colorado River. Though these dams were ultimately never built, Reclamation conducted extensive topographic, bathymetric, and subsurface exploration work at the sites proposed for these dams in the 1940s and 1950s. Resurveys of these dam sites were conducted between 1998 and 2021 to determine the changes in sediment storage at these dam sites caused by the upstream construction and operation of Glen Canyon Dam and by the recession of Lake Mead, the reservoir impounded by Hoover Dam. The resurveys of the Marble Canyon dam sites indicate that the post-1950s changes in sediment storage at these dam sites are broadly consistent with flux-based estimates of voluminous sand erosion from Marble Canyon since the 1963 closure of Glen Canyon Dam. These resurveys also suggest that the pre-dam longitudinal variation in sediment thickness over bedrock played a key role in determining the locations of the sand erosion induced by Glen Canyon Dam; more sand eroded from locations where more sand was present in the 1950s. The resurvey of the Bridge Canyon dam sites indicates that the Colorado River’s incision of the Lake Mead delta is regulated both by bed-sediment grain size and downstream hydraulic controls. Finally, analyses of bed-sediment thickness and sedimentological data at the dam sites, and observations of bed scour and gravel transport, suggest that sufficient bedrock was exposed to allow bedrock incision during commonly recurring pre-dam snowmelt floods that entrained small boulders into transport.

Arizona

The eruptive behavior of distributed volcanism forming low shield edifices—A case study of Sentinel-Arlington volcanic field, U.S.A.

Distributed volcanic fields are present in various tectonic settings worldwide, and their characteristics reflect differing influences from magmatic and tectonic processes. In the southwestern United States alone, there are 37 Quaternary distributed volcanic fields. After the primary period of extensional tectonics in the southern Basin and Range 15–5 million years ago, the Sentinel-Arlington volcanic field developed in southwestern Arizona between 4 and 1 million years ago. The Sentinel-Arlington volcanic field consists primarily of low relief shield volcanoes, a type of distributed volcanism with poorly understood temporal evolution. The Sentinel-Arlington volcanic field is less than 200 kilometers (km) from the Colorado Plateau, Gulf of California, and southern San Andreas Fault system. This work identifies and examines controls on the emplacement of the Sentinel-Arlington volcanic field by documenting shallow and surficial structures as well as eruption characteristics and style through time. The Sentinel-Arlington volcanic field consists of 21 volcanoes with a total of 33 vents over an area of about 770 square kilometers (km 2 ). The prominence of low relief shield volcanoes may be explained by ascent of basaltic magmas through thin Basin and Range crust, without much crustal contamination, and low viscosities common to mafic compositions. Typical eruption characteristics involve the construction of low relief shield volcanoes followed by Strombolian fissure eruptions at the summits or near-summit medial areas that produce scoria lapilli, which may weld to form agglomerate. The total lifetime erupted volume of about 4.3 cubic kilometers (km 3 ) represents an average eruptive flux of approximately 2x10 -3 km 3 per thousand years (k.y.). This erupted volume is low relative to Neogene basaltic intraplate distributed volcanic fields worldwide, which typically range from 10 -3 to 1 km 3 k.y. -1 . Sentinel-Arlington volcanic field eruptions were likely triggered by intermittent rejuvenation of transient magmatic zones that exist in thinned crust. Instantaneous flux from point sources feeding the lava flows is estimated to be on the order of 10 -1 to 10 cubic meters per second.

Arizona

Capitalization of positional (Lower/Middle/Upper) and temporal (Early/Middle/Late) adjectives in the names of formal chronostratigraphic and geochronologic units of the Phanerozoic

Many authors are understandably confused about the capitalization of the words “lower,” “middle,” “upper,” “early,” and “late.” Where these words are used simply as descriptive adjectives, they should be in lowercase; where they form the first word of a formal chronostratigraphic or geochronologic unit name, they should be in uppercase.

Professional Paper