Tools to evaluate reservoir thermal energy storage (RTES; heat storage in slow-moving or stagnant geochemically evolved permeable zones in strata that underlie well-connected regional aquifers) are developed and applied to the Columbia River Basalt Group (CRBG) beneath the Portland Basin, Oregon, USA. The performance of RTES for heat storage and recovery in the Portland Basin is strongly dependent on the operational schedule of heat injection and extraction. We examined the effects of the operational schedule, based on an annual solar hot water supply pattern and a building heating demand model, using heat and fluid flow simulations with SUTRA. We show RTES to be feasible for supply of heating energy for a large combined research/teaching building on the Oregon Health and Science University South Waterfront expansion, an area of planned future development. Initially, heat is consumed to increase the reservoir temperature, and conductive heat loss is high due to high temperature gradients between the reservoir and surrounding rock. Conductive heat loss continues into the future, but the rate of heat loss decreases, and heat recovery efficiency of the RTES system increases over time. Simulations demonstrate the effects of varying heat-delivery rate and temperature on the heat production history of the reservoir. If 100% of building heating needs are to be supplied by combined solar/RTES, then the solar system must be sized to meet building needs plus long-term thermal losses (i.e., conductive losses once the system is heated to pseudo-steady state) from the RTES system. If the solar heating system barely meets these criteria, then during early years, less than 100% of the building demand will be supplied until the reservoir is fully-heated. The duration of supplying less than 100% of building demand can be greatly shortened by pre-heating the reservoir before building heating operations or by adding extra heat from external sources during early years. Analytic solutions are developed to evaluate efficacy and to help design RTES systems (e.g., well-spacing, thermal source sizing, etc.). A map of thermal energy storage capacity is produced for the CRBG beneath the Portland Basin. The simulated building has an annual heat load of ∼1.9 GWh, and the total annual storage capacity of the Portland Basin is estimated to be 43,400 GWh assuming seasonal storage of heat yields water from which 10 °C can be extracted via heat exchange, indicating a tremendous heating capacity of the CRBG.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 45.1433047394883° to 46.00840867976967° latitude; -123.057861328125° to -122.1844482421875° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Erick R. Burns, John Bershaw, Colin F. Williams, Ray E Wells, Matt W Uddenberg, Darby P Scanlon, Trenton T Cladouhos, Boz Van Houten. 2020. Using saline or brackish aquifers as reservoirs for thermal energy storage, with example calculations for direct-use heating in the Portland Basin, Oregon, USA. https://doi.org/10.1016/j.geothermics.2020.101877

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Prioritizing resource protection and understanding potential susceptibility of springs to surficial changes in a low-temperature geothermal system

Geothermal systems are vulnerable to changes in water budget and composition, requiring science-based management. This study uses a dataset of spring water temperatures, time series of groundwater residence time tracers (tritium and carbon-14), and stable isotopes of water to understand geothermal flow in a low-temperature geothermal system in north west Colorado, United States (Steamboat Springs). The geothermal system is bisected by the Yampa River, necessitating a stream mass balance approach to quantify total discharge. Time series analysis of water temperature data provides a ranked list of features more susceptible to surficial changes, which is corroborated using time series of tritium which indicate spatially distinct patterns of mixing between modern and pre-modern groundwater. All springs contain a portion of pre-modern groundwater that is thousands to tens of thousands of years old, a period coinciding with melting of extensive Pleistocene glaciers that was likely one of the recharge sources to the geothermal system. Stream mass balance indicates that greater than 80% of the total geothermal discharge is derived from diffuse or small springs, highlighting the extensive nature of the geothermal outflow zone and the association with local geologic structures. This study provides baseline data to support management of the Steamboat Springs geothermal system and indicates the utility of these approaches in developing science-based geothermal management.

Colorado

Reservoir thermal energy storage pre-assessment for the United States

Storing thermal energy underground for later use in electricity production or direct-use heating/cooling is a promising, viable, and economical green energy option. Reservoir thermal energy storage (RTES) is one such option, which stores energy in underutilized permeable strata with low ambient groundwater flow rates and more geochemically evolved (e.g. brackish/saline) waters relative to overlying principal aquifer systems. The U.S. Geological Survey has begun assessing RTES potential nationally by focusing on five generalized geologic regions (Basin and Range, Coastal Plain, Illinois Basin, Michigan Basin, Pacific Northwest) across the United States. Hydrogeologic reservoir models are developed for the following eight metropolitan area cities within those regions to evaluate RTES performance across different climates and subsurface conditions: Albuquerque, New Mexico; Charleston, South Carolina; Chicago and Decatur, Illinois; Lansing, Michigan; Memphis, Tennessee; Phoenix, Arizona; and Portland, Oregon. Evaluated metrics include estimated required well spacing, thermal storage capacity, and thermal recovery efficiency through time. Also considered for each reservoir are potential complicating factors, including reservoir depth, thermally driven free convection, and groundwater salinity. This work focuses on direct-use cooling because the need for cooling modern office buildings greatly exceeds that for heating in most parts of the country (Falta and others, 2016); however, the evaluated metrics are also relevant to heating and electricity applications. Results indicate that favorable RTES conditions exist in each region, with the Coastal Plain and Basin and Range being especially favorable for thermal storage capacity, while the Pacific Northwest and Michigan Basin excel at energy recovery for the evaluated cooling application. The results underscore the utility of developing maps of thermal storage capacity, subsurface temperature models, and volumetric estimates of thermal storage capacity to serve as key RTES resource classification standards. Overall, this pre-assessment provides a basic understanding of RTES potential in several cities and geologic regions throughout the country and will aid ongoing thermal energy storage assessment efforts.

Arizona, Illinois, Michigan, New Mexico, Oregon, S

Favorability mapping for hydrothermal power resource assessments of the Great Basin, USA

The U.S. Geological Survey (USGS) is updating the 2008 assessment of conventional hydrothermal resources for the Great Basin in the western United States. As part of this work, the workflow for hydrothermal resource favorability maps is being modified to integrate modern data-driven machine learning (ML) methods. Improvements include: [1] using new and refined evidence layers (features); [2] using an order of magnitude more training sites (labeled examples); [3] utilizing simple but non-linear supervised ML algorithms; [4] representing positive training sites (wells with measured heat flow) with their ordinal value proportional to the magnitude of convective upflow (i.e., low, high, or very high convective signals instead of past strategies using positive-negative labels); [5] supplementing training sites with additional sites with low convective signals to represent diverse under-sampled areas where hydrothermal systems are unlikely to exist; [6] comparing with competing approaches; and [7] utilizing Monte Carlo cross-validation to estimate and evaluate prediction uncertainty. For the new favorability map, over half of the power-producing systems (i.e., 15 of 28) are predicted in the 99th percentile of most favorable locations (i.e., the highest 1 % of favorability, corresponding to 1 % of the map area), exceeding the performance of past models that have explicitly used power plants as training sites. Previous favorability maps predicted approximately half of the power-producing hydrothermal systems above the 80th percentile (i.e., 20 % of the map area). For the new favorability map, 93 % of power-producing systems (i.e., 26 of 28) are above the 80th percentile. The power-producing systems for which the new model does not perform well are either comparatively small, low-temperature systems or systems also not predicted well by prior modeling approaches, suggesting that these few systems are unusual when compared with most power-producing systems. Focusing research on these known, seemingly different systems may yield new insights and subsequent discovery of new prospects.

California, Idaho, Nevada, Oregon, Utah