USGS Science⌕ Search

USGS · 70032062

Comparison of blood aminotransferase methods for assessment of myopathy and hepatopathy in Florida manatees (Trichechus manatus latirostris)

Abstract

Muscle injury is common in Florida manatees (Trichechus manatus latirostris). Plasma aspartate amino-transferase (AST) is frequently used to assess muscular damage in capture myopathy and traumatic injury. Therefore, accurate measurement of AST and alanine aminotransferase (ALT) is important in managed, free-ranging animals, as well as in those rehabilitating from injury. Activities of these enzymes, however, are usually not increased in manatees with either acute or chronic muscle damage, despite marked increases in plasma creatine kinase activity. It is hypothesized that this absence of response is due to apoenzymes in the blood not detected by commonly used veterinary assays. Addition of coenzyme pyridoxal-5-phosphate (P5P or vitamin B6) should, therefore, result in higher measured enzyme activities. The objective of this study was to determine the most accurate, precise, and diagnostically useful method for aminotransferase measurement in manatees that can be used in veterinary practices and diagnostic laboratories. Additionally, appropriate collection and storage techniques were assessed. The use of an optimized commercial wet chemical assay with 100 ??mol P5P resulted in a positive bias of measured enzyme activities in a healthy population of animals. However, AST and ALT were still much lower than that typically observed in domestic animals and should not be used alone in the assessment of capture myopathy and muscular trauma. Additionally, the dry chemistry analyzer, typically used in clinics, reported significantly higher and less precise AST and ALT activities with poor correlation to those measured with wet chemical methods found in diagnostic laboratories. Therefore, these results cannot be clinically compared. Overall, the optimized wet chemical method was the most precise and diagnostically useful measurement of aminotransferase in samples. Additionally, there was a statistically significant difference between paired serum and plasma measurement, indicating that separate reference intervals should be established for serum and plasma. Finally, storage of these enzymes at -70??C for 1 mo resulted in up to a 25% decrease in enzymatic activity in manatee plasma. Copyright 2008 by American Association of Zoo Veterinarians.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K.E. Harr, K. Allison, R. K. Bonde, D. Murphy, J. W. Harvey. 2008. Comparison of blood aminotransferase methods for assessment of myopathy and hepatopathy in Florida manatees (Trichechus manatus latirostris). https://doi.org/10.1638/2007-0134r.1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Computed tomography for measuring body fat reserves in threatened Mohave desert tortoise (Gopherus agassizii)

Noninvasive methods for measuring fat reserves in both captive and free-ranging animals are important for monitoring individual and population health, but chelonian anatomy and physiology present challenges to accurate measurements. Standard field-based methods for assessing body condition in Mojave desert tortoises ( Gopherus agassizii ) involve the qualitative body condition score, which relies on the apparent height of the temporalis muscle relative to the sagittal crest (in addition to other characteristics) and quantitative body condition indices that measure relative mass at size. However, it is unclear how these metrics relate to body fat reserves in this species. The aims of this study were to (1) describe the use of noninvasive computed tomography in measuring body fat volume of Mojave desert tortoises, (2) describe the location of fat reserves, (3) investigate relationships between fat reserves and body condition score and body condition index, and (4) explore whether relative temporalis muscle depth, measured via computed tomography, correlates with body condition score. Body condition scores were assessed for eight captive Mojave desert tortoises prior to euthanasia, and computed tomography was performed postmortem to quantify fat volume and measure temporalis muscle depth. At necropsy, the distribution of fat was documented. Fat volume calculated by computed tomography ranged from 2.83 to 145.38 cm 3 (0.07–2.5% body volume). Neither qualitative body condition score nor quantitative body condition index was correlated with fat volume. Bladder content did not compromise body condition index. Body condition score was not correlated with relative temporalis muscle depth. Computed tomography is a noninvasive method for successfully identifying fat reserves and estimating total fat volume in Mojave desert tortoises. The lack of a relationship between computed tomography-determined metrics and commonly used body condition metrics indicates that computed tomography fills a critical gap in the health assessment tool kit for captive and free-ranging Mojave desert tortoises.

Journal of Zoo and Wildlife Medicine↗

Reference values and comparison of blood chemistry and plasma protein values between gold standard analyzers and four point-of-care devices in free-ranging canvasbacks (Aythya valisineria)

Accurate, timely, and cost-effective blood chemistry analysis is an essential tool for directing emergency treatment, monitoring the health status of captive and free-ranging individuals and flocks, and improving the efficacy of conservation actions. Blood samples were obtained from 52 canvasbacks ( Aythya valisineria ) that were captured on San Francisco Bay, California, during December 2017 as part of a long-term study. Reference values and clinical agreement were determined for blood chemistry and plasma protein parameters among four commonly used point-of-care devices (VetScan ® VS2, i-STAT ® , AlphaTRAK ® 2 glucometer, refractometer) and two gold standard laboratory analyzers (Roche cobas ® c501, Helena SPIFE 3000 system). Canvasback reference values were generally within expected ranges for Anatidae species with the exception of higher upper limits for sodium and chloride. Creatine kinase and aspartate transaminase values exceeded a published threshold for diagnosis of capture myopathy even though study birds were captured using low-stress techniques and successfully released. With the exception of higher alkaline phosphatase in hatch-year canvasbacks, no age or sex differences were observed for any analyte in this population that was captured during a nonbreeding period. Analysis of analyzer agreement found raw VetScan aspartate transaminase, calcium, glucose, and uric acid values; corrected VetScan albumin, potassium, sodium, and total protein values; raw i-STAT glucose and potassium values; and corrected i-STAT sodium and chloride values were clinically interchangeable with Roche cobas values. Raw VetScan and i-STAT glucose values were also interchangeable. However, none of the Roche or point-of-care analyzer plasma protein values were in clinical agreement with gold standard electrophoresis values. The findings of this study highlight the need for analyzer- or technique-specific reference values and provide biologists and veterinarians quantitative reference values using currently available analyzers to better assess and respond to the health of individuals and populations.

California↗

Validation of ultrasound as a noninvasive tool to measure subcutaneous fat depth in leatherback sea turtles ( Dermochelys coriacea )

Leatherback turtles ( Dermochelys coriacea ) undergo substantial cyclical changes in body condition between foraging and nesting. Ultrasonography has been used to measure subcutaneous fat as an indicator of body condition in many species but has not been applied in sea turtles. To validate this technique in leatherback turtles, ultrasound images were obtained from 36 live-captured and dead-stranded immature and adult turtles from foraging and nesting areas in the Pacific and Atlantic oceans. Ultrasound measurements were compared with direct measurements from surgical biopsy or necropsy. Tissue architecture was confirmed histologically in a subset of turtles. The dorsal shoulder region provided the best site for differentiation of tissues. Maximum fat depth values with the front flipper in a neutral (45–90°) position demonstrated good correlation with direct measurements. Ultrasound-derived fat measurements may be used in the future for quantitative assessment of body condition as an index of health in this critically endangered species.

Journal of Zoo and Wildlife Medicine↗