USGS Science⌕ Search

Geology topics

Research about Massachusetts

Source-linked reports with geographic coverage including Massachusetts.

At least 397 records · Page 22Linked to original sources

Phosphorus in a ground-water contaminant plume discharging to Ashumet Pond, Cape Cod, Massachusetts, 1999

The discharge of a plume of sewagecontaminated ground water emanating from the Massachusetts Military Reservation to Ashumet Pond on Cape Cod, Massachusetts, has caused concern about excessive loading of nutrients, particularly phosphorus, to the pond. The U.S. Air Force is considering remedial actions to mitigate potentially adverse effects on the ecological characteristics of the pond from continued phosphorus loading. Concentrations as great as 3 milligrams per liter of dissolved phosphorus (as P) are in ground water near the pond's shoreline; concentrations greater than 5 milligrams per liter of phosphorus are in ground water farther upgradient. Temporary drive-point wells were used to collect water samples from 2 feet below the pond bottom to delineate concentration distributions in the pore waters of the pond-bottom sediments. Measurements in the field of specific conductance and colorimetrically determined orthophosphate concentrations provided real-time data to guide the sampling. The contaminant plume discharges to the Fishermans Cove area of Ashumet Pond as evidenced by elevated levels of specific conductance and boron, which are chemically conservative indicators of the sewage-contaminated ground water. Concentrations of nonconservative species, such as dissolved phosphorus, manganese, nitrate, and ammonium, also were elevated above background levels in ground water discharging to the pond, but in spatially complex distributions that reflect their distributions in ground water upgradient of the pond. Phosphorus concentrations exceeded background levels (greater than 0.10 milligram per liter) in the pond-bottom pore water along 875 feet of shoreline. Greatest concentrations (greater than 2 milligrams per liter) occurred within 30 feet of the shore in an area about 225 feet long. Calculations of phosphorus flux in the aquifer upgradient of Ashumet Pond, as determined from water-flux estimates from a steady-state ground-water-flow model and phosphorus concentrations (in 1999) from multilevel samplers about 75 feet upgradient of the pond, indicate that dissolved phosphorus moves towards the pond and discharges to it with the inflowing ground water at a rate as high as about 316 kilograms per year.

Massachusetts↗

Sediment quantity and quality in three impoundments in Massachusetts

As part of a study with an overriding goal of providing information that would assist State and Federal agencies in developing screening protocols for managing sediments impounded behind dams that are potential candidates for removal, the U.S Geological Survey determined sediment quantity and quality at three locations: one on the French River and two on Yokum Brook, a tributary to the west branch of the Westfield River. Data collected with a global positioning system, a geographic information system, and sediment-thickness data aided in the creation of sediment maps and the calculation of sediment volumes at Perryville Pond on the French River in Webster, Massachusetts, and at the Silk Mill and Ballou Dams on Yokum Brook in Becket, Massachusetts. From these data the following sediment volumes were determined: Perryville Pond, 71,000 cubic yards, Silk Mill, 1,600 cubic yards, and Ballou, 800 cubic yards. Sediment characteristics were assessed in terms of grain size and concentrations of potentially hazardous organic compounds and metals. Assessment of the approaches and methods used at study sites indicated that ground-penetrating radar produced data that were extremely difficult and time-consuming to interpret for the three study sites. Because of these difficulties, a steel probe was ultimately used to determine sediment depth and extent for inclusion in the sediment maps. Use of these methods showed that, where sampling sites were accessible, a machine-driven coring device would be preferable to the physically exhausting, manual sediment-coring methods used in this investigation. Enzyme-linked immunosorbent assays were an effective tool for screening large numbers of samples for a range of organic contaminant compounds. An example calculation of the number of samples needed to characterize mean concentrations of contaminants indicated that the number of samples collected for most analytes was adequate; however, additional analyses for lead, copper, silver, arsenic, total petroleum hydrocarbons, and chlordane are needed to meet the criteria determined from the calculations. Particle-size analysis did not reveal a clear spatial distribution pattern at Perryville Pond. On average, less than 65 percent of each sample was greater in size than very fine sand. The sample with the highest percentage of clay-sized particles (24.3 percent) was collected just upstream from the dam and generally had the highest concentrations of contaminants determined here. In contrast, more than 90 percent of the sediment samples in the Becket impoundments had grain sizes larger than very fine sand; as determined by direct observation, rocks, cobbles, and boulders constituted a substantial amount of the material impounded at Becket. In general, the highest percentages of the finest particles, clays, occurred in association with the highest concentrations of contaminants. Enzyme-linked immunosorbent assays of the Perryville samples showed the widespread presence of petroleum hydrocarbons (16 out of 26 samples), polycyclic aromatic hydrocarbons (23 out of 26 samples), and chlordane (18 out of 26 samples); polychlorinated biphenyls were detected in five samples from four locations. Neither petroleum hydrocarbons nor polychlorinated biphenyls were detected at Becket, and chlordane was detected in only one sample. All 14 Becket samples contained polycyclic aromatic hydrocarbons. Replicate quality-control analyses revealed consistent results between paired samples. Samples from throughout Perryville Pond contained a number of metals at potentially toxic concentrations. These metals included arsenic, cadmium, copper, lead, nickel, and zinc. At Becket, no metals were found in elevated concentrations. In general, most of the concentrations of organic compounds and metals detected in Perryville Pond exceeded standards for benthic organisms, but only rarely exceeded standards for human contact. The most highly contaminated samples were collected from sites at the upstream and downstream ends of Perryville Pond. To estimate the potential toxicity of the sediment samples to invertebrates on the basis of their concentrations of metals and organic contaminants, consensus-based sediment-toxicity guidelines were applied. The results of the calculations based on these guidelines highlighted the locations of potentially toxic contaminant "hot spots" in Perryville Pond. Interpretation of sample data from the Becket impoundments did not indicate the existence of similar pockets of potentially toxic contamination.

Massachusetts↗

Reactive-transport simulation of phosphorus in the sewage plume at the Massachusetts Military Reservation, Cape Cod, Massachusetts

The subsurface transport of phosphorus introduced by the disposal of treated sewage effluent to ground-infiltration disposal beds at the Massachusetts Military Reservation on western Cape Cod was simulated with a three-dimensional reactive-transport model. The simulations were used to estimate the load of phosphorus transported to Ashumet Pond during operation of the sewage-treatment plant from 1936 to 1995 and for 60 years following cessation of sewage disposal. The model accounted for spatial and temporal changes in water discharge from the sewage-treatment plant, ground-water flow, transport of associated chemical constituents, and a set of chemical reactions, including phosphorus sorption on aquifer materials, dissolution and precipitation of iron- and manganese-oxyhydroxide and iron phosphate minerals, organic carbon sorption and decomposition, cation sorption, and irreversible denitrification. The flow and transport in the aquifer were simulated by using parameters consistent with those used in previous flow models of this area of Cape Cod, except that numerical dispersion was much larger than the physical dispersion estimated in previous studies. Sorption parameters were fit to data derived from phosphorus sorption and desorption laboratory column experiments. Rates of organic carbon decomposition were adjusted to match the location of iron concentrations in an anoxic iron zone within the sewage plume. The sensitivity of the simulated load of phosphorus transported to Ashumet Pond was calculated for a variety of processes and input parameters. Model limitations included large uncertainties associated with the loading of the sewage beds, the flow system, and the chemistry and sorption characteristics in the aquifer. The results of current model simulations indicate a small load of phosphorus transported to Ashumet Pond during 1965-85, but this small load was particularly sensitive to model parameters that specify flow conditions and the chemical process by which non-desorbable phosphorus is incorporated in the sediments. The uncertainties were large enough to make it difficult to determine whether loads of phosphorus transported to Ashumet Pond in the 1990s were greater or less than loads during the previous two decades. The model simulations indicate substantial discharge of phosphorus to Ashumet Pond after about 1965. After the period 2000-10 the simulations indicate that the load of phosphorus transported to Ashumet Pond decreases continuously, but the load of phosphorus remains substantial for many decades. The current simulations indicate a peak in phosphorus discharge to Ashumet Pond of about 1,000 kilograms per year during the 1990s; however, comparisons of simulated phosphorus concentrations with measured concentrations in 1993 indicate that the peak in phosphorus load transported to Ashumet Pond may be larger and moving more quickly in the model simulations than in the aquifer. The results of the three-dimensional reactive-transport simulations are consistent with the loading history, experimental laboratory data, and field measurements. The results of the simulations adequately reproduce the spatial distribution of phosphorus concentrations measured in 1993, the magnitude of changes in phosphorus concentration with time in a profile near the disposal beds following cessation of sewage disposal, the observed iron zone in the sewage plume, the approximate flow of treated sewage effluent into Ashumet Valley, and laboratory-column data for phosphorus sorption and desorption.

Massachusetts↗

Simulation of advective flow under steady-state and transient recharge conditions, Camp Edwards, Massachusetts Military Reservation, Cape Cod, Massachusetts

The U.S. Geological Survey has developed several ground-water models in support of an investigation of ground-water contamination being conducted by the Army National Guard Bureau at Camp Edwards, Massachusetts Military Reservation on western Cape Cod, Massachusetts. Regional and subregional steady-state models and regional transient models were used to (1) improve understanding of the hydrologic system, (2) simulate advective transport of contaminants, (3) delineate recharge areas to municipal wells, and (4) evaluate how model discretization and time-varying recharge affect simulation results. A water-table mound dominates ground-water-flow patterns. Near the top of the mound, which is within Camp Edwards, hydraulic gradients are nearly vertically downward and horizontal gradients are small. In downgradient areas that are further from the top of the water-table mound, the ratio of horizontal to vertical gradients is larger and horizontal flow predominates. The steady-state regional model adequately simulates advective transport in some areas of the aquifer; however, simulation of ground-water flow in areas with local hydrologic boundaries, such as ponds, requires more finely discretized subregional models. Subregional models also are needed to delineate recharge areas to municipal wells that are inadequately represented in the regional model or are near other pumped wells. Long-term changes in recharge rates affect hydraulic heads in the aquifer and shift the position of the top of the water-table mound. Hydraulic-gradient directions do not change over time in downgradient areas, whereas they do change substantially with temporal changes in recharge near the top of the water-table mound. The assumption of steady-state hydraulic conditions is valid in downgradient area, where advective transport paths change little over time. In areas closer to the top of the water-table mound, advective transport paths change as a function of time, transient and steady-state paths do not coincide, and the assumption of steady-state conditions is not valid. The simulation results indicate that several modeling tools are needed to adequately simulate ground-water flow at the site and that the utility of a model varies according to hydrologic conditions in the specific areas of interest.

Massachusetts↗

Diffusion and drive-point sampling to detect ordnance-related compounds in shallow ground water beneath Snake Pond, Cape Cod, Massachusetts, 2001-02

Diffusion samplers and temporary drive points were used to test for ordnance-related compounds in ground water discharging to Snake Pond near Camp Edwards at the Massachusetts Military Reservation, Cape Cod, MA. The contamination resulted from artillery use and weapons testing at various ranges upgradient of the pond.The diffusion samplers were constructed with a high-grade cellulose membrane that allowed diffusion of explosive compounds, such as RDX (Hexahydro-1,3,5-trinitro-1,3,5-triazine) and HMX (Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine), into deionized water inside the samplers. Laboratory tests confirmed that the cellulose membrane was permeable to RDX and HMX. One transect of 22 diffusion samplers was installed and retrieved in August-September 2001, and 12 transects with a total of 108 samplers were installed and retrieved in September-October 2001. The diffusion samplers were buried about 0.5 feet into the pond-bottom sediments by scuba divers and allowed to equilibrate with the ground water beneath the pond bottom for 13 to 27 days before retrieval. Water samples were collected from temporary well points driven about 2-4 feet into the pond bottom at 21 sites in December 2001 and March 2002 for analysis of explosives and perchlorate to confirm the diffusion-sampling results. The water samples from the diffusion samplers exhibited numerous chromatographic peaks, but evaluation of the photo-diode-array spectra indicated that most of the peaks did not represent the target compounds. The peaks probably are associated with natural organic compounds present in the soft, organically enriched pond-bottom sediments. The presence of four explosive compounds at five widely spaced sites was confirmed by the photo-diode-array analysis, but the compounds are not generally found in contaminated ground water near the ranges. No explosives were detected in water samples obtained from the drive points. Perchlorate was detected at less than 1 microgram per liter in two drive-point samples collected at the same site on two dates about 3 months apart. The source of the perchlorate in the samples could not be related directly to other contamination from Camp Edwards with the available information. The results from the diffusion and drive-point sampling do not indicate an area of ground-water discharge with concentrations of the ordnance-related compounds that are sufficiently elevated to be detected by these sampling methods. The diffusion and drive-point sampling data cannot be interpreted further without additional information concerning the pattern of ground-water flow at Snake Pond and the distributions of RDX, HMX, and perchlorate in ground water in the aquifer near the pond.

Massachusetts↗

Electrical imaging of tracer migration at the Massachusetts Military Reservation, Cape Cod

Electrical resistivity tomography (ERT) is examined as a method to provide spatially continuous information about aquifer properties through imaging of tracer flow and transport in an unconfined aquifer. Field data were collected at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during the summer of 2002. High resolution images in both space and time of the movement of an electrically conductive sodium-chloride tracer in three dimensions (3-D) help delineate aquifer heterogeneity. Sixty 3-D data sets were collected between four corner-point wells for 20 days following the 9-hour injection. Concentrations were measured at a 15-point multilevel sampler centrally located within the ERT array, at the production well, and at two wells external to the central array. The tomograms indicate movement of the saline tracer consistent with measured concentration data. The resistivity tomograms serve as an appropriate surrogate for concentration maps that are otherwise impossible to obtain. Under reasonable assumptions, estimates of groundwater.

Massachusetts↗

Field evidence for a protistan role in an organically-contaminated aquifer

The association between protists, bacteria, and dissolved organic carbon (DOC) in an oxygen-depleted, 6 km-long wastewater contaminant plume within a sandy aquifer (Cape Cod, MA) was investigated by comparing abundance patterns along longitudinal and vertical transects and at a control site. Strong linear correlations were observed between unattached bacterial abundance and DOC for much of the upgradient-half of the plume (0.1−2.5 km downgradient from the source) that is characterized by quasi-steady state chemistry. However, a logarithmic decrease was observed between the number of protists supported per mg of DOC and the estimated age of the DOC within the plume. The relatively labile dissolved organic contaminants that characterize the groundwater sampled from the plume ≤0.1 km downgradient from the contaminant source appeared to indirectly support 3−4 times as many protists (per mg of DOC) as the older, more recalcitrant DOC in the alkylbenzene sulfonate (ABS)-contaminated zone at 3 km downgradient (∼30 years travel time). Substantive numbers of protists (>10 4 /cm 3 ) were recovered from suboxic zones of the plume. The higher than expected ratios of protists to unattached bacteria (10 to 100:1) observed in much of the plume suggest that protists may be grazing upon both surface-associated and unattached bacterial communities to meet their nutritional requirements. In closed bottle incubation experiments, the presence of protists caused an increase in bacterial growth rate, which became more apparent at higher amendments of labile DOC (3−20 mgC/L). The presence of protists resulted in an increase in the apparent substrate saturation level for the unattached bacterial community, suggesting an important role for protists in the fate of more-labile aquifer organic contaminants.

Massachusetts↗

Multispecies reactive tracer test in an aquifer with spatially variable chemical conditions, Cape Cod, Massachusetts: Dispersive transport of bromide and nickel

Dispersive transport of groundwater solutes was investigated as part of a multispecies reactive tracer test conducted under spatially variable chemical conditions in an unconfined, sewage‐contaminated sand and gravel aquifer on Cape Cod, Massachusetts. Transport of the nonreactive tracer bromide (Br) reflected physical and hydrologic processes. Transport of the reactive tracer nickel (Ni) complexed with an organic ligand (NiEDTA) varied in response to pH and other chemical conditions within the aquifer. A loss of about 14% of the Ni mass was calculated from the distribution of tracers through time. This loss is consistent with reversible adsorption of NiEDTA onto the iron and aluminum oxyhydroxide coatings on the aquifer sediments. The Ni consistently lagged behind Br with a calculated retardation coefficient of 1.2. Longitudinal dispersivities reached constant values of 2.2 and 1.1 m for Br and Ni, respectively, by at least 69 m of travel. The smaller dispersivity for Ni possibly was due to nonlinear or spatially variant adsorption of NiEDTA. In the upper, uncontaminated zone of the aquifer, longitudinal dispersion of Ni was greater than that of Br early in the test as a result of reversible adsorption of NiEDTA. In general, transverse dispersivities were much smaller (horizontal: 1.4–1.5 × 10 −2 m; vertical: 0.5–3.8 × 10 −3 m) than the longitudinal dispersivities. The Br results are similar to those from a test conducted eight years earlier, suggesting that transport parameters are spatially stationary within the aquifer at the scale of 300 m covered by the spatially overlapping tests. A significant difference between the two tests was the travel distance (69 and 26 m) needed to reach a constant longitudinal dispersivity.

Massachusetts↗

Design and performance of a horizontal mooring for upper-ocean research

This paper describes the design and performance of a two-dimensional moored array for sampling horizontal variability in the upper ocean. The mooring was deployed in Massachusetts Bay in a water depth of 84 m for the purpose of measuring the horizontal structure of internal waves. The mooring was instrumented with three acoustic current meters (ACMs) spaced along a 170-m horizontal cable that was stretched between two subsurface buoys 20 m below the sea surface. Five 25-m-long vertical instrument strings were suspended from the horizontal cable. A bottom-mounted acoustic Doppler current profiler (ADCP) was deployed nearby to measure the current velocity throughout the water column. Pressure sensors mounted on the subsurface buoys and the vertical instrument strings were used to measure the vertical displacements of the array in response to the currents. Measurements from the ACMs and the ADCP were used to construct time-dependent, two-dimensional current fields. The current fields were used as input to a numerical model that calculated the deformation of the array with respect to the nominal zero-current configuration. Comparison of the calculated vertical offsets of the downstream subsurface buoy and downstream vertical instrument string with the pressure measurements were used to verify the numerical code. These results were then used to estimate total deformation of the array due to the passage of the internal waves. Based on the analysis of the three internal wave events with the highest measured vertical offsets, it is concluded that the geometry of the main structure (horizontal cable and anchor legs) was kept to within ±2.0 m, and the geometry of the vertical instrument strings was kept to within ±4.0 m except for one instance when the current velocity reached 0.88 m s −1 .

Massachusetts↗

Survival of stream-dwelling Atlantic salmon: Effects of life history variation, season, and age

To determine seasonal and age-class variation in the abundance and survival of Atlantic salmon Salmo salar , we conducted multiple samplings of individually tagged juveniles in a small stream (West Brook, Massachusetts). We also estimated the differences in survival and probability of smolting for mature and immature parr. Survival was approximately twofold lower during winter as compared with summer and was higher for fish in their first winter than for fish in their second winter. Parr maturation rates were high (50% of all fish) and peaked in September. The estimated numbers of mature and immature fish were equal for the March samples preceding the smolt run, indicating no overall differences in survival between mature and immature fish during stream residence. Age-2 mature fish were one-third as likely to smolt as immature fish, however, resulting in survival probabilities (from March to smoltification) of 0.22 for mature fish and 0.61 for immature fish. Approximately one-third of the fish captured in the smolt trap were estimated as mature during previous sampling, and virtually all of the age-2 fish remaining in the stream following the smolt run were previously mature. We found no differences in gill Na + , K + ATPase activity between previously mature smolts and immature smolts, but activity was significantly higher in March for fish that later smolted than for those that did not.

Massachusetts↗

A night seining technique for sampling juvenile Atlantic salmon in streams

For many studies of the population dynamics, growth, and movement of juvenile Atlantic salmon Salmo salar , it is necessary to resample tagged individuals multiple times. However, common sampling techniques such as electrofishing can have negative effects on fish survival and growth, especially when individuals are repeatedly sampled. We describe an alternative to electrofishing that involves sampling at night with small, one-person seines. Juvenile Atlantic salmon in a small brook were tagged with passive integrated transponder tags and sampled 15 times by means of night seining, day electrofishing, and day seining techniques. Capturing juvenile Atlantic salmon by day seining was inefficient, resulting in a capture probability estimate of 0.18. The mean capture probability estimate was 0.45 during night seining samples and 0.78 during electrofishing samples. The total number of age-0 Atlantic salmon captured via night seining increased 4.5 times after fish attained a mean fork length of just over 60 mm. A much greater number of brook trout Salvelinus fontinalis and brown trout Salmo trutta were captured in electrofishing samples than in night seining samples. Night seining may prove useful when electrofishing is impractical, when threatened or endangered species exist, or when multiple recaptures of individuals are desired.

Massachusetts↗

Effects of water-management alternatives on streamflow in the Ipswich River basin, Massachusetts

Management alternatives that could help mitigate the effects of water withdrawals on streamflow in the Ipswich River Basin were evaluated by simulation with a calibrated Hydrologic Simulation Program--Fortran (HSPF) model. The effects of management alternatives on streamflow were simulated for a 35-year period (1961-95). Most alternatives examined increased low flows compared to the base simulation of average 1989-93 withdrawals. Only the simulation of no septic-effluent inflow, and the simulation of a 20-percent increase in withdrawals, further lowered flows or caused the river to stop flowing for longer periods of time than the simulation of average 1989-93 withdrawals. Simulations of reduced seasonal withdrawals by 20 percent, and by 50 percent, resulted in a modest increase in low flow in a critical habitat reach (model reach 8 near the Reading town well field); log-Pearson Type III analysis of simulated daily-mean flow indicated that under these reduced withdrawals, model reach 8 would stop flowing for a period of seven consecutive days about every other year, whereas under average 1989-93 withdrawals this reach would stop flowing for a seven consecutive day period almost every year. Simulations of no seasonal withdrawals, and simulations that stopped streamflow depletion when flow in model reach 19 was below 22 cubic feet per second, indicated flow would be maintained in model reach 8 at all times. Simulations indicated wastewater-return flows would augment low flow in proportion to the rate of return flow. Simulations of a 1.5 million gallons per day return flow rate indicated model reach 8 would stop flowing for a period of seven consecutive days about once every 5 years; simulated return flow rates of 1.1 million gallons per day indicated that model reach 8 would stop flowing for a period of seven consecutive days about every other year. Simulation of reduced seasonal withdrawals, combined with no septic effluent return flow, indicated only a slight increase in low flow compared to low flows simulated under average 1989-93 withdrawals. Simulation of reduced seasonal withdrawal, combined with 2.6 million gallons per day wastewater-return flows, provided more flow in model reach 8 than that simulated under no withdrawals.

Massachusetts↗

Preliminary assessment of streamflow requirements for habitat protection for selected sites on the Assabet and Charles rivers, eastern Massachusetts

Streamflow requirements for habitat protection were determined at several critical riffle reaches in the Assabet River and Charles River Basins. The R2Cross and Wetted-Perimeter methods yielded median streamflow requirements of 0.75 cubic feet per second per square mile (ft3/s/mi2) and 0.13 ft3/s/mi2, respectively. Three study reaches are on tributaries to the Assabet River (Danforth Brook, Great Brook, and Elizabeth Brook), two are on the mainstem of the Charles River, and one is on a tributary to the Charles River (Mine Brook). The strength of the R2Cross and Wetted-Perimeter methods is that they may be applied at ungaged locations. A Range of Variability Approach analysis was conducted on a common 30-year period of record from 1969 to 1998 for five mostly unaltered flow, streamgaging stations. The discharge range defined by the median R2Cross and Wetted-Perimeter streamflow requirements brackets the interquartile range for the median of monthly-mean flows during the summer low-flow period, as defined by the Range of Variability Approach analysis of five streamgaging stations. The median R2Cross streamflow requirement for the five riffles compares very closely to the median Tennant 40-percent of the mean annual flow requirement for good habitat condition. The median Wetted-Perimeter streamflow requirement compares closely to the median Tennant 10-percent of the mean annual-flow requirement for a poor habitat condition. Tennant and Range of Variability Approach methods require continuous discharge records for analysis.

Massachusetts↗

Volatile organic compounds, specific conductance, and temperature in the bottom sediments of Mill Pond, Ashland, Massachusetts, April 2001

A plume of volatile organic compounds in ground water extends northward from the former Nyanza Property in Ashland, Massachusetts, and discharges into the Sudbury River and the upstream end of Mill Pond. A network of polyethylene-membrane passive-vapor-diffusion samplers was installed in February 2001 to help define the lateral extent of the plume under the pond, including an area vegetated by wetland herbs, sedges, and shrubs. Chlorobenzene and trichloroethene were detected with passive-vapor-diffusion samplers at five locations in the bottom sediments of the southern part of the approximate one acre of vegetated area in Mill Pond. Vapor concentrations of chlorobenzene ranged from 178 to 2,210 parts per billion by volume, and vapor concentrations of trichloroethene ranged from 20 to 96 parts per billion by volume. Chlorobenzene also was detected in one sediment-pore-water sample extracted with a push-point sampler in this area; the concentration was 25 micrograms per liter. Toluene was detected with passive-vapor-diffusion samplers at three sites in the open pond area north of the vegetated areas. Vapor concentrations of toluene ranged from 20 to 90 parts per billion by volume. Specific conductance and temperature of sediment-pore waters were measured at selected sampling sites in Mill Pond to examine their possible associations with the presence of volatile organic compounds. Temperature in the sediment-pore water also was measured to convert vapor concentrations of volatile organic compounds collected with diffusion samplers to equivalent water concentrations. These equivalent water concentrations were then to be compared with water concentrations collected with a push-point sampler. Because of the limited detections of volatile organic compounds at sites where water samples were collected and where specific conductance and temperature were measured, these potential associations and conversions could not be assessed.

Massachusetts↗

Effectiveness of three best management practices for highway-runoff quality along the Southeast Expressway, Boston, Massachusetts

Best management practices (BMPs) near highways are designed to reduce the amount of suspended sediment and associated constituents, including debris and litter, discharged from the roadway surface. The effectiveness of a deep-sumped hooded catch basin, three 2-chambered 1,500-gallon oil-grit separators, and mechanized street sweeping in reducing sediment and associated constituents was examined along the Southeast Expressway (Interstate Route 93) in Boston, Massachusetts. Repeated observations of the volume and distribution of bottom material in the oil-grit separators, including data on particle-size distributions, were compared to data from bottom material deposited during the initial 3 years of operation. The performance of catch-basin hoods and the oil-grit separators in reducing floating debris was assessed by examining the quantity of material retained by each structural BMP compared to the quantity of material retained by and discharged from the oil-grit separators, which received flow from the catch basins. The ability of each structural BMP to reduce suspended-sediment loads was assessed by examining (a) the difference in the concentrations of suspended sediment in samples collected simultaneously from the inlet and outlet of each BMP, and (b) the difference between inlet loads and outlet loads during a 14-month monitoring period for the catch basin and one separator, and a 10-month monitoring period for the second separator. The third separator was not monitored continuously; instead, samples were collected from it during three visits separated in time by several months. Suspended-sediment loads for the entire study area were estimated on the basis of the long-term average annual precipitation and the estimated inlet and outlet loads of two of the separators. The effects of mechanized street sweeping were assessed by evaluating the differences between suspended-sediment loads before and after street sweeping, relative to storm precipitation totals, and by comparing the particle-size distributions of sediment samples collected from the sweepers to bottom-material samples collected from the structural BMPs. A mass-balance calculation was used to quantify the accuracy of the estimated sediment-removal efficiency for each structural BMP. The ability of each structural BMP to reduce concentrations of inorganic and organic constituents was assessed by determining the differences in concentrations between the inlets and outlets of the BMPs for four storms. The inlet flows of the separators were sampled during five storms for analysis of fecal-indicator bacteria. The particle-size distribution of bottom material found in the first and second chambers of the separators was similar for all three separators. Consistent collection of floatable debris at the outlet of one separator during 12 storms suggests that floatable debris were not indefinitely retained. Concentrations of suspended sediment in discrete samples of runoff collected from the inlets of the two separators ranged from 8.5 to 7,110 mg/L. Concentrations of suspended sediment in discrete samples of runoff collected from the outlets of the separators ranged from 5 to 2,170 mg/L. The 14-month sediment-removal efficiency was 35 percent for one separator, and 28 percent for the second separator. In the combined-treatment system in this study, where catch basins provided primary suspended-sediment treatment, the separators reduced the mass of the suspended sediment from the pavement by about an additional 18 percent. The concentrations of suspended sediment in discrete samples of runoff collected from the inlet of the catch basin ranged from 32 to 13,600 mg/L. Concentrations of suspended sediment in discrete samples of runoff collected from the outlet of the catch basin ranged from 25.7 to 7,030 mg/L. The sediment-removal efficiency for individual storms during the 14-month monitoring period for the deep-sumped hooded catch basin was 39 percent. The concentrations of 29 inorganic constituents in bottom sediments were typically higher for the size fraction less than 0.062 mm in diameter. Concentrations of total organic carbon (TOC) were similar for the size fraction less than 0.062 mm in diameter and the fraction greater than 2.00 mm in diameter. Concentrations of total polyaromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) were larger in the fraction greater than 2.00 mm in diameter than in the size fractions less than 2.00 mm in diameter. Since PAHs and PCBs are commonly associated with TOC (including organically coated sediment), it is believed that the PCB and PAH concentrations in the solid fraction less than 0.062 mm in diameter were similar to the concentrations in the solid fraction greater than 2.00 mm in diameter, if not greater because of the effects of the surface area. The estimated annual suspended-sediment load for the entire study area was about 29,000 kg. Approximately 24,000 kg discharged directly to Malibu Beach and Tenean Beach embayments, and the remaining 5,000 kg discharged to the land surface. These loads do not include an estimated 2,000 kg of suspended sediment retained by the five oil-grit separators in the area. Mechanized street sweepers were used on the pavement three times during the study. Samples of sweepings were collected each time for the analysis of particle size. The first mechanized street sweeping had no observable effect on subsequent storm loads of suspended sediment. Following the second sweeping, a net increase of the suspended-sediment load was observed at one station and a net decrease of the suspended-sediment load was observed at the second station. These effects, however, were only temporary. The third time the highway was swept was after continuous monitoring was terminated. The particle-size distribution in sweeper samples for the size fraction less than 4 mm in diameter was similar to the particle-size distribution in bottom sediment in the catch basin. The concentration of particles greater than 0.5 mm in diameter was higher in sweeper samples than in samples from the separators, so the sweepers were successful in removing the larger particles. Because the highway lacks curbing that would provide a physical boundary to trap debris and sediment, and the equipment was inefficient in trapping particles less than 0.062 mm in diameter, pavement sweeping provided few water-quality benefits for the Southeast Expressway. The primary factor controlling the efficiency of each structural BMP in removing suspended sediment was retention time. Examination of constituent-sediment relations suggests that the retention time for many highway-related constituents was short; these constituents either were dissolved and not subject to treatment by simple gravity separation, or were associated with particles less than 0.062 mm in diameter, which commonly passed through the BMPs. Thus, the potential effectiveness of the separators and the catch basins to reduce loads of inorganic and organic constituents was much less than their ability to reduce loads of suspended sediment. The average relative percent difference (RPD) between concentrations of trace metals in stormwater samples from the inlets and the outlets of the separators ranged from 15 to 30 percent. The average RPD for concentrations of organic constituents was commonly less than about 10 percent and negative in several cases. The separators did not affect the concentrations of dissolved solids as they passed through their chambers. The average RPD between the event mean concentrations for trace metals in samples collected from the inlet and outlet of the catch basin during storms was about 25 percent. The average RPD for concentrations of organic constituents was typically less than 20 percent and even negative in several cases, except for oil and grease, which was near 30 percent. The observed ranges of the RPDs for both types of BMPs were probably larger than the actual ranges because the particle-size and concentration of suspended sediment sampled in the BMP inflows during the four storms introduced a bias in favor of higher concentrations. Concentrations of fecal and Enterococci bacteria were found throughout the storms at the inlets of the two continuously monitored separators; this result indicated that the pavement washoff process was inefficient or that there was a continuous source of bacteria in the drainage area. The efficiency of the structural BMPs tested in this study in reducing fecal-indicator bacteria concentrations was not quantified; each BMP chamber is likely to retain a quantity of fecal-indicator bacteria proportional to its storage volume after a storm. Removal of bacteria from the BMP is dependent on how well the bacteria survive until the next storm and the potential for bacterial export during the next storm.

Massachusetts↗