Archive of chirp subbottom data collected during USGS cruise ATSV99045, northern North Carolina, October 9-27, 1999
No abstract available.
subject
Report: explore 620 source-linked works published from 1913 to 2026, with original documents and citations.
This collection is a preview while coverage and quality are evaluated.
Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.
Sources: usgs. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.
No abstract available.
No abstract available.
No abstract available.
No abstract available.
No abstract available.
Winter snow accumulation and summer snow, firn, and ice melt were measured at South Cascade Glacier, Washington, to determine the winter and net balances for the 1999 balance year. The 1999 winter snow balance, averaged over the glacier, was 3.59 meters, and the net balance was 1.02 meters. Since the winter balance record began in 1959, only three winters have had a higher winter balance. Since the net balance record began in 1953, only 2 years have had a greater positive net balance than 1999. Runoff was measured from the glacier and an adjacent non-glacierized basin. Air temperature, precipitation, and humidity were measured nearby, and ice speed was measured. This report makes these data available to the glaciological and climatological community.
No abstract available.
Forty-four river, stream, and drain sites in the Upper Colorado River Basin in Colorado were sampled during 1996-98 to determine the occurrence and distribution of pesticides in the basin. In a fixed-station study, 57 surface-water samples were collected from October 1996 through January 1998 at four sites. Each site was sampled approximately monthly for up to a year, with more frequent sampling during the spring and summer growing season. In a synoptic study, surface-water samples were collected at 43 sites in the agricultural areas of the Grand Valley and the Uncompahgre River Valley in May 1998. Each site was sampled once. Pesticide concentrations generally were low and varied seasonally and across land uses. Thirty-five pesticides were detected at least once in the two studies, and 11 pesticides accounted for almost 82 percent of the detections. Herbicides were more commonly detected than insecticides, and only the herbicides alachlor and atrazine were detected in more than 50 percent of the samples. Carbofuran was the most commonly detected insecticide and was detected in 19 percent of the samples. Pesticide detections increased and were measured at higher concentrations in the summer months and at the agriculture sites. All pesticide concentrations were less than drinking-water standards, and most complied with human-health advisories and criteria for the protection of freshwater aquatic life. Pesticides in the Upper Colorado River Basin in Colorado were detected slightly less frequently and generally at lower concentrations than in 20 National Water-Quality Assessment Program study-unit basins that collected water-quality data from 1992 through 1996. Results from surface-water sampling conducted during 1996?98 in the Upper Colorado River Basin in Colorado indicate that beneficial uses of water were not being impaired by the presence of pesticides in surface waters in the basin.
Periodic and continual water-level data from 1963 to 1998 were compiled and quality assured for 65 observation wells on Pahute Mesa and vicinity, Nye County, Nevada. As part of the quality assurance of all water levels, ancillary data pertinent to computing hydraulic heads in wells were compiled and analyzed. Quality-assured water levels that were not necessarily in error but which did not represent static heads in the regional aquifer system, or required some other qualification, were flagged. Water levels flagged include those recovering from recent pumping or well construction, water levels affected by nuclear tests, and measurements affected by borehole deviations. A cursory examination of about 30 wells with available water-level and down-hole temperature data indicate that water levels in most wells on Pahute Mesa would not be significantly affected by temperature if corrected to 95 degrees Fahrenheit. Wells with large corrections (greater than 10 feet) are those with long water columns (greater than 1,500 feet of water above the assumed point of inflow) in combination with mean water-column temperatures exceeding 105 degrees Fahrenheit. Water-level fluctuations in wells on Pahute Mesa are caused by several factors including infiltration of precipitation, barometric pressure, Earth tides, ground-water pumpage, and seismic events caused by tectonic activity and underground nuclear testing. No observed water-level fluctuations were attributed to a naturally occurring earthquake. The magnitude and duration of changes in water levels caused by nuclear tests are affected by the test size and the distance from a well to the test. Identifying water levels that might be affected by past nuclear tests is difficult because pre-testing water-level data are sparse. Hydrologically significant trends were found in 13 of 25 wells with multiple years of water-level record. The largest change in water levels (1,029 feet in 25 years) occurred in well U-19v PS 1D as a result of the Almendro nuclear test. Likely explanations for trends in most of the wells are either changes in precipitation patterns that affect recharge rates to the ground-water system, pumping effects from water-supply well U-20 WW, or a combination of these two factors.
Ground-penetrating radar was used to measure the depth and extent of existing and infilled scour holes and previous scour surfaces at seven bridges in New Hampshire from April 1996 to November 1998. Ground-penetrating-radar survey techniques initially were used by the U.S. Geological Survey to study streambed scour at 30 bridges. Sixteen of the 30 bridges were re-surveyed where floods exceeded a 2-year recurrence interval. A 300-megahertz signal was used in the ground-penetrating radar system that penetrated through depths as great as 20 feet of water and as great as 32 feet of streambed materials. Existing scour-hole dimensions, infilled thickness, previous scour surfaces, and streambed materials were detected using ground-penetrating radar. Depths to riprap materials and pier footings were identified and verified with bridge plans. Post data-collection-processing techniques were applied to assist in the interpretation of the data, and the processed data were displayed and printed as line plots. Processing included distance normalization, migration, and filtering but processing was kept to a minimum and some interference from multiple reflections was left in the record. Of the 16 post-flood bridges, 22 ground-penetrating-radar cross sections at 7 bridges were compared and presented in this report. Existing scour holes were detected during 1996 (pre-flood) data collection in nine cross sections where scour depths ranged from 1 to 3 feet. New scour holes were detected during 1998 (post-flood) data collection in four cross sections where scour depths were as great as 4 feet deep. Infilled scour holes were detected in seven cross sections, where depths of infilling ranged from less than 1 to 4 feet. Depth of infilling by means of steel rod and hammer was difficult to verify in the field because of cobble and boulder streambeds or deep water. Previous scour surfaces in streambed materials were identified in 15 cross sections and the depths to these surfaces ranged from 1 to 10 feet below the streambed. Riprap materials or pier footings were identified in all cross sections. Calculated record depths generally agree with bridge plans. Pier footings were exposed at two bridges and steel pile was exposed at one bridge. Exposures were verified by field observations.
Suspended-sediment concentrations, discharges, loads, and yields were determined for eight subbasins in the Housatonic River Basin in western Massachusetts, eastern New York, and northwestern Connecticut from April 1994 through March 1996. Suspended-sediment samples were collected at three continuous-record sediment stations and at four partial-record sediment stations. Suspended-sediment concentrations in samples collected during the period of study ranged from less than 0.5 to 3,400 milligrams per liter, and concurrent streamflows ranged from 0.03 to 126 cubic feet per second per square mile at the seven stations. Median suspended-sediment concentrations in samples collected at each station ranged from 7 to 61 milligrams per liter. Median streamflows during suspended-sediment sampling ranged from 1.86 to 5.88 cubic feet per second per square mile. Instantaneous suspended-sediment yields ranged from less than 0.005 to 185 tons per day per square mile, and medians ranged from 0.03 to 1.12 tons per day per square mile at the seven stations. Total suspended-sediment loads (mass) from April 1994 through March 1996 at the continuous-record sediment stations were 11,603 tons at Housatonic River near Great Barrington, 7,929 tons at Green River, and 54,347 tons at Housatonic River near Ashley Falls. Suspended-sediment load during January 1996 at the Green River station accounted for about 54 percent of the total suspended-sediment load for the Green River during the 2-year study. Suspended-sediment load on January 19 and 20, 1996, at the Green River station accounted for about 50 percent of the January 1996 suspended-sediment load, or about 27 percent of the total suspended-sediment load during the 2-year study. This large suspended-sediment transport was the result of rainfall and snowmelt on January 19 and 20, 1996--the equivalent of a 5- to 6-inch rain storm in the Green River subbasin. Total suspended-sediment loads during the 2-year study at the partial-record sediment stations were 3,052 tons at Williams River, 1,758 tons at Ironworks Brook, and 17,927 tons at Konkapot River. Suspended-sediment yields from April 1994 through March 1996 at the continuous-record sediment stations were 21 (tons/yr)/mi 2 at Housatonic River near Great Barrington, 78 (tons/yr)/mi 2 at Green River, and 58 (tons/yr)/mi 2 at Housatonic River near Ashley Falls. Suspended-sediment yields during the 2- year study at the partial-record sediment stations were 35 (tons/yr)/mi 2 at Williams River, 78 (tons/yr)/mi 2 at Ironworks Brook, and 147 (tons/yr)/mi 2 at Konkapot River. Suspended-sediment yields were estimated for two subbasins in the Housatonic River Basin--Schenob Brook at Sheffield, a partial-record sediment station, and the area adjacent to the Housatonic River between Great Barrington and Ashley Falls. The estimate of suspended-sediment yield at Schenob Brook at Sheffield of 82 (tons/yr)/mi 2 is comparable to the yield determined for the Green River and Ironworks Brook. The estimate of suspended-sediment yield for the area adjacent to the Housatonic River between Great Barrington and Ashley Falls was 395 (tons/yr)/mi 2 . This estimated suspended-sediment yield was 2.7 to 18.8 times greater than that estimated for any of the other subbasins. Several basin and land-use characteristics thought to affect suspended-sediment transport in the subbasins were compared to the suspended-sediment yields. The characteristics that seemed to affect suspended-sediment discharge were dams, which contributes to decreased yields; Hadley, Limerick, Linlithgo, Saco, and Winooski silt loam soils (high erodibility soils), which contributes to increased yields; stratified-drift deposits, which contributes to increased yields; and agricultural and open land, which contributes to increased yields. The effect of stratified-drift deposits on suspended-sediment discharge is thought to be greater when those deposits are of glaciolacustrine (generally clay, silt, and fine sand), rather than glaciofluvial (clay, silt, sand, gravel, and cobbles) origin. The silt loam soils, glaciolacustrine deposits, and agricultural and open land are interrelated, inasmuch as the silt loam soils generally are associated with glaciolacustrine deposits and agricultural activities.
Natural attenuation is a viable alternative to pump and treat for meeting remediation objectives in the vicinity of the southern contaminant plume. The combination of historically low contaminant concentrations in ground water, a landfill cap that limits source area contributions, favorable conditions for degradation of VC, and a relatively long downgradient distance to potential receptors are all favorable for natural attenuation as a remediation alternative. Natural attenuation could effectively meet all but one remediation goal that extraction wells PW- 2, PW-4, PW-6, PW-7, PW-8 and PW-9 are currently being employed to meet. The goal of preventing migration of all VC across the site boundary could not be met by natural attenuation. Some VC would migrate south of the Navy boundary, but the potential for subsequent VC mineralization downgradient of the base and the existing institutional controls would result in minimal additional risk from using natural attenuation. In the western contaminant plume natural attenuation is not currently a viable alternative to pump and treat for meeting remediation objectives. There is a possibility that rates for reductive dechlorination of TCE and TCA could increase substantially if the plume was allowed to migrate beneath the Oak Harbor landfill, but there are not enough data to be certain of such an increase. TCA and TCE concentrations at the leading edge of the western plume need to be reduced to at least 25 and 40 µg/L, respectively, to be protective of potential downgradient receptors. Source area TCA and TCE concentrations have decreased substantially over the past ten years, and the extraction wells PW-3 and PW-5 in particular are removing a significant mass of contaminants from ground water, so natural attenuation may be a viable alternative for the western plume in the future. There would be some possible side benefits of using natural attenuation as an alternative to pump and treat in the southern contaminant plume. The first would be that the resulting decrease in the amount of treated water that would need to be recharged in the swale north of the landfill would result in less off-base migration of contamination across the western site boundary. The second benefit would be a substantial reduction in the amount of dissolved iron and manganese being extracted from the shallow aquifer and run through the treatment system. Removing that source of operation and maintenance problems would result in more effective containment and removal of contamination in the western contaminant plume. The most critical data gap identified in this evaluation is the paucity of contaminant chemistry information downgradient of the Navy boundary in the vicinity of the southern contaminant plume. Without such data, the behavior of the plume and the protectiveness of natural attenuation to downgradient receptors cannot be verified, and field attenuation rates for VC cannot be determined directly. The existing long-term monitoring plan would need to be reviewed and revised if natural attenuation is selected as a remedy for the contamination in the southern plume. In particular, additional performance monitoring wells may be required downgradient of the property.
The Scituate Reservoir Basin covers about 94 square miles in north central Rhode Island and supplies more than 60 percent of the State of Rhode Island's drinking water. The basin includes the Scituate Reservoir Basin and six smaller tributary reservoirs with a combined capacity of about 40 billion gallons. Most of the basin is forested and undeveloped. However, because of its proximity to the Providence, Rhode Island, metropolitan area, the basin is subject to increasing development pressure and there is concern that this may lead to the degradation of the water supply. Selected water-quality constituent concentrations, loads, and trends in the Scituate Reservoir Basin, Rhode Island, were investigated locate parts of the basin likely responsible for exporting disproportionately large amounts of water-quality constituents to streams, rivers, and tributary reservoirs, and to determine whether water quality in the basin has been changing with time. Water-quality data collected between 1982 and 1995 by the Providence Water Supply Board PWSB) in 34 subbasins of the Scituate Reservoir Basin were analyzed. Subbasin loads and yields of total coliform bacteria, chloride, nitrate, iron, and manganese, estimated from constituent concentrations and estimated mean daily discharge records for the 1995 water year, were used to determine which subbasins contributed disproportionately large amounts of these constituents. Measurements of pH, color, turbidity, and concentrations of total coliform bacteria, sodium, alkalinity, chloride, nitrate, orthophosphate, iron, and manganese made between 1982 and 1995 by the PWSB were evaluated for trends. To determine the potential effects of human-induced changes in drainage- basin characteristics on water quality in the basin, relations between drainage-basin characteristics and concentrations of selected water-quality constituents also were investigated. Median values for pH, turbidity, total coliform bacteria, sodium, alkalinity, chloride, nitrate, and iron were largest in subbasins with predominately residential land use. Median instantaneous loads reflected drainage-basin size. However, loads normalized by drainage area (median instantaneous yields) also were largest in residential areas where point and non-point sources are likely, and in areas of poorly drained soils. Significant trends in water-quality constituents from 1982 to 1995 in the Scituate Reservoir Basin indicate that the quality of the water resources in the basin may be slowly changing. Scituate Reservoir subbasins with large amounts of residential land use showed increasing trends in alkalinity and chloride. In contrast, subbasins distributed throughout the drainage basin showed increasing trends in pH, color, nitrate, and iron concentrations, indicating that these characteristics and constituents may be affected more by atmospheric deposition. Although changing, water-quality constituent concentrations in the Scituate Reservoir Basin only occasionally exceeded Rhode Island and USEPA water-quality guidelines and standards. Result of correlation analysis between pH, color, turbidity, and concentrations total coliform bacteria, sodium, alkalinity, chloride, nitrate, orthophosphate, iron, and manganese and land use, geology, wetlands, slope, soil drainability, and roads indicated that the percentage of wetlands, roads, and slope appear have the greatest effect on water-quality in the Scituate Reservoir Basin. The percentage of urban, residential, and commercial land use also are important, but to a lesser degree than wetlands, roads, and slope. Finally, geology appears to have the least effect on water quality compared to other drainage-basin characteristics investigated.
Logistic regression was used to relate anthropogenic (man-made) and natural factors to the occurrence of elevated concentrations of nitrite plus nitrate as nitrogen in ground water in the Columbia Basin Ground Water Management Area, eastern Washington. Variables that were analyzed included well depth, depth of well casing, ground-water recharge rates, presence of canals, fertilizer application amounts, soils, surficial geology, and land-use types. The variables that best explain the occurrence of nitrate concentrations above 3 milligrams per liter in wells were the amount of fertilizer applied annually within a 2-kilometer radius of a well and the depth of the well casing; the variables that best explain the occurrence of nitrate above 10 milligrams per liter included the amount of fertilizer applied annually within a 3-kilometer radius of a well, the depth of the well casing, and the mean soil hydrologic group, which is a measure of soil infiltration rate. Based on the relations between these variables and elevated nitrate concentrations, models were developed using logistic regression that predict the probability that ground water will exceed a nitrate concentration of either 3 milligrams per liter or 10 milligrams per liter. Maps were produced that illustrate the predicted probability that ground-water nitrate concentrations will exceed 3 milligrams per liter or 10 milligrams per liter for wells cased to 78 feet below land surface (median casing depth) and the predicted depth to which wells would need to be cased in order to have an 80-percent probability of drawing water with a nitrate concentration below either 3 milligrams per liter or 10 milligrams per liter. Maps showing the predicted probability for the occurrence of elevated nitrate concentrations indicate that the irrigated agricultural regions are most at risk. The predicted depths to which wells need to be cased in order to have an 80-percent chance of obtaining low nitrate ground water exceed 600 feet in the irrigated agricultural regions, whereas wells in dryland agricultural areas generally need a casing in excess of 400 feet. The predicted depth to which wells need to be cased to have at least an 80-percent chance to draw water with a nitrate concentration less than 10 milligrams per liter generally did not exceed 800 feet, with a 200-foot casing depth typical of the majority of the area.
The U.S. Geological Survey (USGS), in cooperation with Oakland County Health Division (OCHD), collected 140 water samples from 38 wells in Oakland County during 1998 to better understand ground-water quality. OCHD had observed temporal variations in concentrations of various constituents, so two additional sets of samples were collected to evaluate potential short-term variability related to sample collection procedures and long-term seasonal variability. Replicate samples from 28 wells were analyzed in the Michigan Department of Environmental Quality (MDEQ) Drinking Water Laboratory to compare MDEQ’s analytical results to those obtained from the USGS National Water Quality Laboratory. Several additional databases describing population, land use, water supply, soils, geology, and flows of ground water and surface water are presented in the first part of the report to assist in interpreting the water-quality data. Maps created from these databases are provided in the first portion of the report as an extension of the study-area description. The U.S. Environmental Protection Agency (USEPA) has established Maximum Contaminant Levels (MCL) and Secondary Maximum Contaminant Levels (SMCL) for which samples were analyzed in this study. Water from the 38 wells sampled by the USGS did not exceed the SMCL or MCL for sulfate, fluoride, or nitrite. However, water from 26 wells exceeded the SMCL for iron, water from 12 wells exceeded the SMCL for manganese, and water from 12 wells exceeded the SMCL for dissolved solids. Water from two wells exceeded the MCL for nitrate, although nitrate concentrations in water from most wells was below the detection limit. Water from seven wells exceeded the SMCL for chloride, and water from all wells contained detectable concentrations of chloride. Water from five wells exceeded the MCL for arsenic, and most of the wells sampled contained detectable concentrations of arsenic. These five wells were identified from previous MDEQ analyses to have elevated arsenic concentrations, and were sampled to obtain additional chemistry information. Replicate samples were collected from 26 of the 38 wells for analysis at the MDEQ Drinking-Water Laboratory to compare the results with the USGS National Water Quality Laboratory. The results of the replicate analyses indicate close agreement between the laboratories, with mean differences for nitrate, chloride, and arsenic of 0.10 milligrams per liter (mg/L) as nitrogen, 6.8 mg/L, and 0.0008 mg/L, respectively between the USGS and MDEQ analyses. Potential health effects associated with ingesting nitrate, chloride, and arsenic are provided with the water-quality data, along with references for further information.