USGS ScienceSearch

Geology topics

J. E. Landmeyer

Publications and source records attributed to J. E. Landmeyer.

25 records · Page 2Linked to original sources

Assessment of intrinsic bioremediation of gasoline contamination in the shallow aquifer, Laurel Bay Exchange, Marine Corps Air Station Beaufort, South Carolina

Laboratory, field, and digital solute-transport- modeling studies demonstrate that microorganisms indigenous to the shallow ground-water system at Laurel Bay Exchange, Marine Corps Air Station Beaufort, South Carolina, can degrade petroleum hydrocarbons in gasoline released at the site. Microorganisms in aquifer sediments incubated in the laboratory under aerobic and anaerobic conditions mineralized radiolabeled carbon 14-toluene to 14 C-carbon dioxide with first-order rate constants of K bio = -0.640 per day and K bio = -0.003 per day, respectively. Digital solute- transport modeling using the numerical code SUTRA revealed that anaerobic biodegradation of benzene occurs with a first-order rate constant near K bio = -0.00025 per day. Sandy aquifer material beneath Laurel Bay Exchange is characterized by relatively high hydraulic conductivities (K aq = 8.9 to 17.3 feet per day), average ground-water flow rate of about 60 feet per year, and a relatively uniform hydraulic gradient of 0.004 feet per foot. The sandy aquifer material also has low adsorptive potentials for toluene and benzene (both about K ad = 2.0 x 10 -9 cubic feet per milligram), because of the lack of natural organic matter in the aquifer. The combination of this ground-water-flow rate and absence of significant adsorptive capacity in the aquifer permits toluene and benzene concentrations to be detected downgradient from the source area in monitoring wells, even though biodegradation of these compounds has been demonstrated. Solute-transport simulations, however, indicate that toluene and benzene will not reach the Broad River, the nearest point of contact with wildlife or human populations, about 3,600 feet west of the site boundary. These simulations also show that contamination will not be transported to the nearest Marine Corps property line about 2,400 feet south of the site. This is primarily because the source of contaminants has essentially been removed, and the low adsorptive capacity of the aquifer sediments has prevented the occurrence of an adsorbed, continuous source of petroleum hydrocarbons. Therefore, digital simulations of toluene and benzene transport at Laurel Bay Exchange indicate that intrinsic bioremediation could be a successful remediation alternative for prohibiting transport of dissolved toluene and benzene to the Broad River.

South Carolina

Distribution of petroleum hydrocarbons and toluene biodegradation, Knox Street fire pits, Fort Bragg, North Carolina

An investigation was conducted at the Knox Street fire pits, Fort Bragg, North Carolina, to monitor the distribution of toluene, ethylbenzene, and xylene (TEX) in soil vapor, ground water, and ground-water/vapor to evaluate if total concentrations of TEX at the site are decreasing with time, and to quantify biodegradation rates of toluene in the unsaturated and saturated zones. Soil-vapor and ground-water samples were collected around the fire pits and ground-water/vapor samples were collected along the ground-water discharge zone, Beaver Creek, on a monthly basis from June 1994 through June 1995. Concentrations of TEX compounds in these samples were determined with a field gas chro- matograph. Laboratory experiments were performed on aquifer sediment samples to measure rates of toluene biodegradation by in situ micro- organisms. Based on field gas chromatographic analytical results, contamination levels of TEX compounds in both soil vapor and ground water appear to decrease downgradient of the fire-pit source area. During the 1-year study period, the observed temporal and spatial trends in soil vapor TEX concentrations appear to reflect differences in the distribution of TEX among solid, aqueous, and gaseous phases within fuel-contaminated soils in the unsaturated zone. Soil temperature and soil moisture are two important factors which influence the distribution of TEX com- pounds among the different phases. Because of the short period of data collection, it was not possible to distinguish between seasonal fluc- tuations in soil vapor TEX concentrations and an overall net decrease in TEX concentrations at the study site. No seasonal trend was observed in total TEX concentrations for ground- water samples collected at the study site. Although the analytical results could not be used to determine if ground-water TEX concen- trations decreased during the study at a specific location, the data were used to examine rate constants of toluene biodegradation. Based on ground-water toluene concentration data, a maximum rate constant for anaerobic biodegradation of toluene in the saturated zone was estimated to be as low as 0.002 d-1 or as high as 0.026 d-1. Based on analyses of ground-water/vapor samples, toluene was the prin- cipal TEX compound identified in ground water discharging to Beaver Creek. Observed decreases in ground-water/vapor toluene concentrations during the study period may reflect a decrease in source inputs, an increase in dilution caused by higher ground-water flow, and(or) removal by biological or other physical processes. Rate constants of toluene anaerobic biodegradation determined by laboratory measurements illustrate a typical acclimation response of micro-organisms to hydrocarbon contamination in sediments collected from the site. Toluene biodegradation rate constants derived from laboratory microcosm studies ranged from 0.001 to 0.027 d-1, which is similar to the range of 0.002 to 0.026 d-1 for toluene biodegradation rate constants derived from ground-water analytical data. The close agreement of toluene biodegradation rate constants reported using both approaches offer strong evidence that toluene can be degraded at environmentally significant rates at the study site.

Water-Resources Investigations Report

Geology, hydrogeology, and potential of intrinsic bioremediation at the National Park Service Dockside II site and adjacent areas, Charleston, South Carolina, 1993-94

A long history of industrial and commercial use of the National Park Service property and adjacent properties located in downtown Charleston, South Carolina, has caused extensive contamination of the shallow subsurface soils and water-table aquifer. The National Park Service property is located adjacent to a former manufactured-gas plant site, which is the major source of the contamination. Contamination of this shallow water-table aquifer is of concern because shallow ground water discharges to the Cooper River and contains contaminants, which may affect adjacent wildlife or human populations. The geology of the National Park Service property above the Ashley Formation of the Cooper Group consists of two Quaternary lithostratigraphic marine units, the Wando Formation and Holocene deposits, overlain by artificial fill. The Wando Formation overlies the Ashley Formation, a sandy calcareous clay, and consists of soft, organic clay overlain by gray sand. The Holocene deposits are composed of clayey to silty sand and soft organic-rich clay. The artificial fill, which was placed at the site to create dry land where salt marsh existed previously, is composed of sand, silt, and various scrap materials. The shallow hydrogeology of the National Park Service property overlying the Ashley Formation can be subdivided into two sandy aquifers separated by a leaky, black, organic-rich clay. The unconfined upper surficial aquifer is primarily artificial fill. The lower surficial aquifer consists of the Wando sand unit and is confined by the leaky organic-rich clay. Aquifer tests performed on the wells screened in these aquifers resulted in hydraulic conductivities from 0.1 to 10 feet per day for the upper surficial aquifer, and 16 feet per day for the lower surficial aquifer. Vertical hydraulic gradients at the site are typically low. A downward gradient from the upper surficial aquifer to the lower surficial aquifer occurs throughout most of the year. A brick-lined storm-water-drainage archway located in the study area is a conduit for the overflow of seawater into the surficial aquifer during exceptionally high tides. The efficiency of intrinsic bioremediation to reduce contaminant migration in the upper surficial aquifer at the National Park Service site was assessed to determine if, and at what concentrations, contaminants are being transported to the Cooper River. This assessment required incorporating hydrologic, geochemical, microbiologic, and demographic information into a predictive solute-transport model to determine rates of contaminant transport to the Cooper River. The transport of toluene and naphthalene was modeled as a surrogate for the transport of aromatic and other hydrocarbon compounds at the study area. Laboratory estimates of the adsorption coefficients for sediments of the upper surficial aquifer suggest preferential adsorption of naphthalene over toluene. The adsorption coefficient of naphthalene is at least two orders of magnitude greater than that determined for toluene. Laboratory microbial-biodegradation experiments indicate that microorganisms present in the shallow aquifer have the potential to degrade toluene under anaerobic and aerobic conditions, and naphthalene primarily under aerobic conditions. Rates of microbial biodegradation are similar for both compounds under aerobic conditions. Flow-model calibration to the January 1994 water-table surface of the upper surficial aquifer was achieved by specifying appropriate hydrogeologic boundary conditions and using hydraulic conductivity values determined in the field. The brick-lined storm-water drainage archway located in the study area was modeled to account for ground-water discharge through this drain. An exploratory modeling approach was used to evaluate the range of possible solutions that approximate the transport of contaminants to the observed distributions. Approximate toluene solute-transport conditions for January 1994 were estimated using velocity dist

South Carolina

Assessment of intrinsic bioremediation of jet fuel contamination in a shallow aquifer, Beaufort, South Carolina

Field and laboratory studies show that microorganisms indigenous to the ground-water system underlying Tank Farm C, Marine Corps Air Station Beaufort, S.C., degrade petroleum hydrocarbons under aerobic and anaerobic conditions. Under aerobic conditions, sediments from the shallow aquifer underlying the site mineralized radiolabeled (14C) toluene to 14CO2 with first-order rate constants of about -0.29 per day. Sediments incubated under anaerobic conditions mineralized radiolabeled toluene more slowly, with first-order rate constants of -0.001 per day. Although anaerobic rates of biodegradation are low, they are significant in the hydrologic and geochemical context of the site. Because of low hydraulic conductivities (1.9-9.1 feet per day) and low hydraulic gradients (about 0.004 feet per feet), ground water flows slowly (approximately 20 feet per year) at this site. Furthermore, aquifer sediments contain organic-rich peat that has a high sorptive capacity. Under these conditions, hydrocarbon contaminants have moved no further than 10 feet downgradient of the jet fuel free product. Digital solute-transport simulations, using the range of model parameters measured at the site, show that dissolved contaminants will be completely degraded before they are discharged from the aquifer into adjacent surface-water bodies. These results show that natural attenuation processes are containing the migration of soluble hydrocarbons, and that intrinsic bioremediation is a potentially effective remedial strategy at this site.

South Carolina

Microbial transformation of nitroaromatics in surface soils and aquifer materials

Microorganisms indigenous to surface soils and aquifer materials collected at a munitions-contaminated site transformed 2,4,6-trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DNT), and 2,6-dinitrotoluene (2,6-DNT) to amino-nitro intermediates within 20 to 70 days. Carbon mineralization studies with both unlabeled (TNT, 2,4-DNT, and 2,6-DNT) and radiolabeled ([ 14 C]TNT) substrates indicated that a significant fraction of these source compounds was degraded to CO 2 .

Missouri

Description and application of capture zone delineation for a wellfield at Hilton Head Island, South Carolina

Ground-water capture zone boundaries for individual pumped wells in a confined aquffer were delineated by using groundwater models. Both analytical and numerical (semi-analytical) models that more accurately represent the $round-water-flow system were used. All models delineated 2-dimensional boundaries (capture zones) that represent the areal extent of groundwater contribution to a pumped well. The resultant capture zones were evaluated on the basis of the ability of each model to realistically rapresent the part of the ground-water-flow system that contributed water to the pumped wells. Analytical models used were based on a fixed radius approach, and induded; an arbitrary radius model, a calculated fixed radius model based on the volumetric-flow equation with a time-of-travel criterion, and a calculated fixed radius model derived from modification of the Theis model with a drawdown criterion. Numerical models used induded the 2-dimensional, finite-difference models RESSQC and MWCAP. The arbitrary radius and Theis analytical models delineated capture zone boundaries that compared least favorably with capture zones delineated using the volumetric-flow analytical model and both numerical models. The numerical models produced more hydrologically reasonable capture zones (that were oriented parallel to the regional flow direction) than the volumetric-flow equation. The RESSQC numerical model computed more hydrologically realistic capture zones than the MWCAP numerical model by accounting for changes in the shape of capture zones caused by multiple-well interference. The capture zone boundaries generated by using both analytical and numerical models indicated that the curnmtly used 100-foot radius of protection around a wellhead in South Carolina is an underestimate of the extent of ground-water capture for pumped wetis in this particular wellfield in the Upper Floridan aquifer. The arbitrary fixed radius of 100 feet was shown to underestimate the upgradient contribution of ground-water flow to a pumped well.

South Carolina

Influence of Pb on microbial activity in Pb-contaminated soils

Investigations of the influence of Pb on soil microbial communities have focused on Pb concentrations of 1 g kg-’ or less (Barkay et al., 1985; Capone et al., 1983; Chang and Broadbent, 1981; Doelman and Haanstra, 1979; Trevors et al., 1985). However, a number of environments exist in which Pb concentrations exceed 1 g kg-’ dry soil (Davenport and Peryea, 1991; Davis et al., 1992; Bisessar, 1982). Bisessar (1982) reported an inverse correlation between Pb concentration and the bacterial population size in soil near a secondary lead smelter. However, similar trends in the concentrations of Pb, As, Cd, and Cu at the site make it difficult to attribute the reductions in population size to Pb alone. Although the effects on microbial carbon mineralization of Pb concentrations as high as 20,000 g kg-’ dry soil were investigated by Debosz et a/. (1985), differences in pH between Pb treatments and the lack of controls for abiotic CO, evolution make the results of the study equivocal. Our purpose was to examine the effects of g kg-’ Pb concentrations on the growth and productivity of soil microbial communities.

Soil Biology and Biochemistry