USGS ScienceSearch

SEARCH · USGS Science

Results for “Talanta”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Spectrophotometric determination of fluorine in silicate rocks

The rock powder is sintered with a sodium carbonate flux containing zinc oxide and magnesium carbonate, the sinter-cake leached with water and the resulting solution filtered. Fluorine is separated from the acidified filtrate by steam distillation and determined spectrophotometrically by means of a zirconium-SPADNS reagent. If a multiple-unit distillation apparatus is used, 12 determinations can be completed per man-day.

Talanta

Determination of palladium, platinum and rhodium in geologic materials by fire assay and emission spectrography

A method is described for the determination of palladium down to 4ppb (parts per billion, 10 9 ), platinum down to 10 ppb and rhodium down to 5 ppb in 15 g of sample. Fire-assay techniques are used to preconcentrate the platinum metals into a gold bead, then the bead is dissolved in aqua regia and diluted to volume with 1 M hydrochloric acid. The solution is analysed by optical emission spectrography of the residue from 200 μl of it evaporated on a pair of flat-top graphite electrodes. This method requires much less sample handling than most published methods for these elements. Data are presented for G-1, W-1, and six new standard rocks of the U.S. Geological Survey. The values for palladium in W-1 are in reasonable agreement with previously published data.

Talanta

Atomic-absorption determination of rhodium in chromite concentrates

Rhodium is determined in chromite concentrates by atomic absorption after concentration either by co-precipitation with tellurium formed by the reduction of tellurite with tin(II) chloride or by fire assay into a gold bead. Interelement interferences in the atomic-absorption determination are removed by buffering the solutions with lanthanum sulphate (lanthanum concentration 1%). Substantial amounts of Ag, Al, Au, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ho, Hg, K, La, Mg, Mn, Mo, Na, Ni, Pb, Te, Ti, V, Y, Zn and platinum metals can be tolerated. A lower limit of approximately 0.07 ppm Rh can be determined in a 3-g sample.

Talanta

Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 μg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.

Talanta

Determination of iridium in mafic rocks by atomic absorption

Iridium is determined in mineralized mafic rocks by atomic absorption after fire-assay concentration into a gold bead. Interelement interferences in the atomic-absorption determination are removed and Ir sensitivity is increased by buffering the solutions with a mixture of copper and sodium sulphates. Substantial amounts of Ag, Al, Au, Bi, Ca, Cd, Co, Cr, Fe, Ho, Hg, K, La, Mg, Mn, Mo, Ni, Pb, Te, Ti, V, Y, Zn and platinum metals can be tolerated in the atomic-absorption determination. The sensitivity and detection limits are 3.2 and 0.25 ppm of Ir, respectively.

Talanta

Spectrophotometric procedure using rhodamine B for determination of submicrogram quantities of antimony in rocks

A spectrophotometric procedure using Rhodamine B is given for the determination of antimony in mineralized rocks after its separation as stibine. A study of the Rhodamine B reaction points to the importance of the order of addition of reagents in enhancing sensitivity and increasing the stability of the system. The tolerance of some 26 elements is established for the overall procedure. Although the limit of determination is approximately 0·5 ppm Sb in a 0·2-g sample, the procedure is intended primarily for screening samples containing more than 1 ppm Sb. In pure solutions 0·1 μg of antimony can be determined with a relative standard deviation of 25%. For >0·2 μg of antimony a relative standard deviation of 15% or less can be expected.

Talanta

Determination of 30 elements in coal and fly ash by thermal and epithermal neutron-activation analysis

Thirty elements are determined in coal and fly ash by instrumental neutron-activation analysis using both thermal and epithermal irradiation. Gamma-ray spectra were recorded 7 and 20 days after the irradiations. The procedure is applicable to the routine analysis of coals and fly ash. Epithermal irradiation was found preferable for the determination of Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, Cs, Ba, Sm, Tb, Hf, Ta, W, Th and U, whereas thermal irradiation was best for Sc, Cr, Fe, Co, La, Ce, Nd, Eu, Yb and Lu. Results for SRM 1632 (coal) and SRM 1633 (fly ash) agree with those of other investigators.

Talanta

Atomic-absorption determination of beryllium in geological materials by use of electrothermal atomization

A method is described for the atomic-absorption determination of beryllium in geological materials, that utilizes electrothermal atomization after a separation by solvent extraction. Samples are decomposed with hydrofluoric acid and nitric acid in Teflon-lined pressure decomposition vessels. Beryllium is isolated by its extraction as beryllium acetylacetonate at pH 8 into xylene and back-extraction in 3 M hydrochloric acid. The method has been successfully applied to the determination of beryllium in 14 U.S. Geological Survey standard rocks. Four subsamples from four bottles of each standard sample were analysed in random order. The mean beryllium contents (ppm) are: AGV-1, 1.98; PCC-1, 0.024; MAG-1, 2.84; BHVO-1, 0.90; DTS-1, 0.026; SCo-1, 1.74; SDC-1, 2.52; BCR-1, 1.44; GSP-1, 1.22; SGR-1, 0.86; QLO-1, 1.83; RGM-1, 2.21; STM-1, 8.75; G-2, 2.29. An analysis of variance shows that all the samples may be considered homogeneous at F 0.95 except AGV-1 and DTS-1 which may be considered homogeneous at F 0.99 .

Talanta

Matrix effects on the determination of manganese in geological materials by atomic-absorption spectrophotometry under different flame conditions

Suppression caused by five of the seven matrix elements studied (Si, Al, Fe, Ca and Mg) was observed in the atomic-absorption determination of manganese in geological materials, when synthetic solutions and the recommended oxidizing air—acetylene flame were used. The magnitude of the suppression effects depends on (1) the kind and concentration of the interfering elements, (2) the type of acid medium, and (3) the concentration of manganese to be determined. All interferences noted are removed or alleviated by using a reducing nitrous oxide—acetylene flame. The atomic-absorption method using this flame can be applied to the determination of total and extractable manganese in a wide range of geological materials without interferences. Analyses of six U.S. Geological Survey rock standards for manganese gave results in agreement with the reported values.

Talanta

The determination of lead in 13 USGS standard rocks

Lead was determined in 13 U.S. Geological Survey standard rocks by graphite furnace atomization and atomic-absorption spectrometry after extraction of lead with diethylammonium diethyldithiocarbamic acid. An analysis of variance of the results obtained from a random sampling of three different bottles of each standard rock showed no heterogeneity among bottles, at the F0.95 level, for a 100-mg sample-size. The relative error of the method, based on the standard deviation of the mean within bottles, was generally less than 10%.

Talanta

Separation of arsenic(III) and arsenic(V) in ground waters by ion-exchange

The predominant species of arsenic in ground water are probably arsenite and arsenate. These can be separated with a strong anion-exchange resin (Dowex 1 × 8; 100–200 mesh, acetate form) in a 10 cm × 7 mm column. Samples are filtered and acidified with concentrated hydrochloric acid (1 ml per 100 ml of sample) at the sample site. Five ml of the acidified sample are used for the separation. At this acidity, As(III) passes through the acetate-form resin, and As(V) is retained. As(V) is eluted by passage of 0.12 M hydrochloric acid through the column (resulting in conversion of the resin back into the chloride form). Samples are collected in 5-ml portions up to a total of 20 ml. The arsenic concentration in each portion is determined by graphite-furnace atomic-absorption spectrophotometry. The first two fractions give the As(III) concentration and the last two the As(V) concentration. The detection limit for the concentration of each species is 1 μg l "> μ gl.

Talanta

An ion-selective electrode method for determination of chlorine in geological materials

A method is presented for the determination of chlorine in geological materials, in which a chloride-selective ion electrode is used after decomposition of the sample with hydrofluoric acid and separation of chlorine in a gas-diffusion cell. Data are presented for 30 geological standard materials. The relative standard deviation of the method is estimated to be better than 8% for amounts of chloride of 10 μg and greater.

Talanta

A rapid geochemical spectrophotometric determination of tungsten with dithiol

1-g sample is decomposed with nitric and hydrofluoric acids, and after evaporation of the solution to dryness the residue is dissolved in concentrated hydrochloric acid. A clear aliquot is treated with stannous chloride to inhibit interferences. The blue tungsten dithiol complex is developed at a temperature of 85° over a half-hour period. The complex is extracted into 2 ml of heptane and the tungsten is determined spectrophotometrically with a sensitivity of 0.5 ppm. Fifty samples per man-day can be analysed in this manner.

Talanta

Determination of arsenic in geological materials by x-ray fluorescence spectrometry after solvent extraction and deposition on a filter

Rock, soil, or sediment samples are decomposed with a mixture of nitric and sulphuric adds. After reduction from arsenic(V) with ammonium thiosulphate, arsenic(III) is extracted as the chlorocomplex into benzene from a sulphuric-hydrochloric acid medium. The benzene solution is transferred onto a filter-paper disc impregnated with a solution of sodium bicarbonate and potassium sodium tartrate, and the benzene allowed to evaporate. The arsenic present is determined by X-ray fluorescence. In a 0.5-g sample, 1–1000 ppm of arsenic can be determined. The close proximity of the lead L α peak (2θ 48.73°), to the arsenic K α peak (2θ 48.83°) does not cause any interference, because lead is not extracted under the experimental conditions. Arsenic values obtained are in agreement with those reported for various reference samples.

Talanta

Determination of total tin in geological materials by electrothermal atomic-absorption spectrophotometry using a tungsten-impregnated graphite furnace

An electrothermal atomic-absorption spectrophotometric method is described for the determination of total tin in geological materials, with use of a tungsten-impregnated graphite furnace. The sample is decomposed by fusion with lithium metaborate and the melt is dissolved in 10% hydrochloric acid. Tin is then extracted into trioctylphosphine oxide-methyl isobutyl ketone prior to atomization. Impregnation of the furnace with a sodium tungstate solution increases the sensitivity of the determination and improves the precision of the results. The limits of determination are 0.5–20 ppm of tin in the sample. Higher tin values can be determined by dilution of the extract. Replicate analyses of eighteen geological reference samples with diverse matrices gave relative standard deviations ranging from 2.0 to 10.8% with an average of 4.6%. Average tin values for reference samples were in general agreement with, but more precise than, those reported by others. Apparent recoveries of tin added to various samples ranged from 95 to 111% with an average of 102%.

Talanta