USGS Science⌕ Search

SEARCH · USGS Science

Results for “Geothermics”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Gases in steam from Cerro Prieto geothermal wells with a discussion of steam/gas ratio measurements

As part of a joint USGS-CFE geochemical study of Cerro Prieto, steam samples were collected for gas analyses in April, 1977. Analyses of the major gas components of the steam were made by wet chemistry (for H2O,CO2,H2S and NH3) and by gas chromatography (He,H2,Ar,O2,N2 and hydrocarbons). The hydrocarbon gases in Cerro Prieto steam closely resemble hydrocarbons in steam from Larderello, Italy and The Geysers, California which, although they are vapor-dominated rather than hot-water geothermal systems, also have sedimentary aquifer rocks. These sedimentary geothermal hydrocarbons are characterized by the presence of branched C4-6 compounds and a lack of unsaturated compounds other than benzene. Relatively large amounts of benzene may be characteristic of high-temperature geothermal systems. All hydrocarbons in these gases other than methane most probably originate from the thermal metamorphosis of organic matter contained in the sediments. ?? 1979.

Geothermics↗

Origin and transport of chloride in superheated geothermal steam

Hydrogen chloride (HCl) is a known component of some volcanic gases and volcanic-related hydrothermal systems. It has recently been discovered in superheated steam in exploited geothermal systems, usually as a result of HCl-induced corrosion of well casing and steam gathering systems. Evaluation of four geothermal systems (Tatun, Taiwan; Krafla, Iceland; Larderello, Italy and The Geysers, USA) which produce CI-bearing steam provides evidence for the presence of Cl as HCl and the natural reservoir conditions which can produce HCl-bearing steam. Theoretical calculations defining the physical and chemical conditions of the reservoir liquid which can produce HCl-bearing steam are presented. The main factors are pH, temperature and Cl concentration. Lower pH, higher temperature and higher chlorinity allow more HCl to be volatilized with steam. In order to reach the surface in steam, the HCl cannot contact liquid water in which it is more soluble, essentially limiting transport to superheated steam. Temperature, pH and Cl concentration of reservoir liquids in each of the geothermal systems evaluated combine differently to produce HCl-bearing steam.

Geothermics↗

Hydrogeochemical exploration of geothermal prospects in the Tecuamburro Volcano region, Guatemala

Chemical and isotopic analyses of thermal and nonthermal waters and of gases from springs and fumaroles are used to evaluate the geothermal potential of the Tecuamburro Volcano region, Guatemala. Chemically distinct geothermal surface manifestations generally occur in separate hydrogeologic areas within this 400 km 2 region: low-pressure fumaroles with temperatures near local boiling occur at 1470 m elevation in a sulfur mine near the summit of Tecuamburro Volcano; non-boiling acid-sulfate hot springs and mud pots are restricted to the Laguna Ixpaco area, about 5 km NNW of the sulfur mine and 350–400 m lower in elevation; steam-heated and thermal-meteoric waters are found on the flanks of Tecuamburro Volcano and several kilometers to the north in the andesitic highland, where the Infernitos fumarole (97°C at 1180 m) is the primary feature; neutral-chloride hot springs discharge along Rio Los Esclavos, principally near Colmenares at 490 m elevation, about 8–10 km SE of Infernitos. Maximum geothermometer temperatures calculated from Colmenares neutral-chloride spring compositions are ~ ∼180° C "> 180°C , whereas maximum subsurface temperatures based on Laguna Ixpaco gas compositions are ~ ∼310° C "> 310°C . An exploration core hole drilled to a depth of 808 m about 0.3 km south of Laguna Ixpaco had a bottom-hole temperature of 238°C but did not produce sufficient fluids to confirm or chemically characterize a geothermal reservoir. Hydrogeochemical data combined with regional geologic interpretations indicate that there are probably two hydrothermal-convection systems, which are separated by a major NW-trending structural boundary, the Ixpaco fault. One system with reservoir temperatures near 300°C lies beneath Tecuamburro Volcano and consists of a large vapor zone that feeds steam to the Laguna Ixpaco area, with underlying hot water that flows laterally to feed a small group of warm, chloriderich springs SE of Tecuamburro Volcano. The other system is located beneath the Infernitos area in the andesitic highland and consists of a lower-temperature (150–190°C) reservoir with a large natural discharge that feeds the Colmenares hot springs.

Tecuamburro Volcano↗

Fluid inclusions and preliminary studies of hydrothermal alteration in core hole PLTG-1, Platanares geothermal area, Honduras

The Platanares geothermal area in western Honduras consists of more than 100 hot springs that issue from numerous hot-spring groups along the banks or within the streambed of the Quebrada de Agua Caliente (brook of hot water). Evaluation of this geothermal area included drilling a 650-m deep PLTG-1 drill hole which penetrated a surface mantling of stream terrace deposits, about 550 m of Tertiary andesitic lava flows, and Cretaceous to lower Tertiary sedimentary rocks in the lower 90 m of the drill core. Fractures and cavities in the drill core are partly to completely filled by hydrothermal minerals that include quartz, kaolinite, mixed-layer illite-smectite, barite, fluorite, chlorite, calcite, laumontite, biotite, hematite, marcasite, pyrite, arsenopyrite, stibnite, and sphalerite; the most common open-space fillings are calcite and quartz. Biotite from 138.9-m depth, dated at 37.41 Ma by replicate 40Ar/39 Ar analyses using a continuous laser system, is the earliest hydrothermal mineral deposited in the PLTG-1 drill core. This mid-Tertiary age indicates that at least some of the hydrothermal alteration encountered in the PLTG-1 drill core occurred in the distant past and is unrelated to the present geothermal system. Furthermore, homogenization temperatures (Th) and melting-point temperatures (Tm) for fluid inclusions in two of the later-formed hydrothermal minerals, calcite and barite, suggest that the temperatures and concentration of dissolved solids of the fluids present at the time these fluid inclusions formed were very different from the present temperatures and fluid chemistry measured in the drill hole. Liquid-rich secondary fluid inclusions in barite and caicite from drill hole PLTG-1 have Th values that range from about 20??C less than the present measured temperature curve at 590.1-m depth to as much as 90??C higher than the temperature curve at 46.75-m depth. Many of the barite Th measurements (ranging between 114?? and 265??C) plot above the reference surface boiling-point curve for pure water assuming hydrostatic conditions; however, the absence of evidence for boiling in the fluid inclusions indicates that at the time the minerals formed, the ground surface must have been at least 80 m higher than at present and underwent stream erosion to the current elevation. Near-surface mixed-layer illite-smectite is closely associated with barite and appears to have formed at about the same temperature range (about 120?? to 200??C) as the fluid-inclusion Th values for barite. Fluid-inclusion Th values for calcite range between about 136?? and 213??C. Several of the calcite Th values are significantly lower than the present measured temperature curve. The melting-point temperatures (Tm) of fluid-inclusion ice yield calculated salinities, ranging from near zero to as much as 5.4 wt. % NaCl equivalent, which suggest that much of the barite and calcite precipitated from fluids of significantly greater salinity than the present low salinity Platanares hot-spring water or water produced from the drill hole.

Journal of Volcanology and Geothermal Research↗

Controls on the Karaha-Telaga Bodas geothermal reservoir, Indonesia

Karaha-Telaga Bodas is a partially vapor-dominated, fracture-controlled geothermal system located adjacent to Galunggung Volcano in western Java, Indonesia. The geothermal system consists of: (1) a caprock, ranging from several hundred to 1600 m in thickness, and characterized by a steep, conductive temperature gradient and low permeability; (2) an underlying vapor-dominated zone that extends below sea level; and (3) a deep liquid-dominated zone with measured temperatures up to 353 ??C. Heat is provided by a tabular granodiorite stock encountered at about 3 km depth. A structural analysis of the geothermal system shows that the effective base of the reservoir is controlled either by the boundary between brittle and ductile deformational regimes or by the closure and collapse of fractures within volcanic rocks located above the brittle/ductile transition. The base of the caprock is determined by the distribution of initially low-permeability lithologies above the reservoir; the extent of pervasive clay alteration that has significantly reduced primary rock permeabilities; the distribution of secondary minerals deposited by descending waters; and, locally, by a downward change from a strike-slip to an extensional stress regime. Fluid-producing zones are controlled by both matrix and fracture permeabilities. High matrix permeabilities are associated with lacustrine, pyroclastic, and epiclastic deposits. Productive fractures are those showing the greatest tendency to slip and dilate under the present-day stress conditions. Although the reservoir appears to be in pressure communication across its length, fluid, and gas chemistries vary laterally, suggesting the presence of isolated convection cells. ?? 2006 CNR.

Geothermics↗

Stochastic inversion of gravity, magnetic, tracer, lithology, and fault data for geologically realistic structural models: Patua Geothermal Field case study

Financial risk due to geological uncertainty is a major barrier for geothermal development. Production from a geothermal well depends on the unknown location of subsurface geological structures, such as faults that contain hydrothermal fluids. Traditionally, geoscientists collect many different datasets, interpret the datasets manually, and create a single model estimating faults' locations. This method, however, does not provide information about the uncertainty regarding the location of faults and often does not fully respect all observed datasets. Previous researchers investigated the use of stochastic inversion schemes for addressing geological uncertainty, but often at the expense of geologic realism. In this paper, we present algorithms and open-source code to stochastically invert five typical datasets for creating geologically realistic structural models. Using a case study with real data from the Patua Geothermal Field, we show that these inversion algorithms are successful in finding an ensemble of structural models that are geologically realistic and match the observed data sufficiently. Geoscientists can use this ensemble of models to optimize reservoir management decisions given structural uncertainty.

Nevada↗

Three-dimensional temperature maps of the Williston Basin, USA: Implications for deep hot sedimentary and enhanced geothermal resources

As part of U.S. Geological Survey's (USGS) efforts to identify and assess geothermal energy resources of the US, a three-dimensional (3D) geologic and thermal model has been constructed for the Williston Basin, USA. The geologic model consists of all sedimentary units above the Proterozoic and Archean crystalline rock (called basement herein), with a total sedimentary thickness of up to 5 km near the basin center. Twenty-nine geologic units were mapped from interpreted formation tops from 16,465 wells. A 3D temperature model was constructed to a depth of 7 km by constructing a 3D heat flow model for the sedimentary units, followed by estimating underlying temperature using a one-dimensional (1D) analytic solution for heat flow within the underlying crystalline basement. Using the sedimentary basin model, heat flow was simulated in 3D and was calibrated using three temperature datasets: 1) 24 high-confidence static temperature logs (equilibrium thermal profiles), 2) more than15,000 drill stem test (DST) measurements from >7,000 wells, and 3) more than 45,000 bottomhole temperature (BHT) measurements from >14,000 wells. The DST and BHT datasets provide broad spatial coverage, but are lower confidence, primarily because measurements were made prior to attaining thermal equilibrium. DST and BHT measurements were binned regionally to develop representative thermal profiles that generally agree with these lower quality data (hereafter called pseudowell temperature profiles). Layer properties (primarily thermal conductivity and compaction curves) were set to best estimate values, then the heat flow model was calibrated to fit pseudowell and static temperature logs primarily by adjusting basal heat flow to approximate the overall temperature profile. Minor adjustments to thermal conductivity allowed adjusting changes in slope at lithologic contacts. Resulting maps include 3D temperature and basal (bottom of sedimentary units) heat flow estimates, which are used as input for the temperature model of the basement. The crystalline basement temperature model uses an analytic 1D solution to the heat flow equation that requires estimates of heat flow and temperature at the upper boundary (i.e., the sediment/basement contact), radiogenic heat production within the crystalline basement, and reference thermal conductivity (i.e., uncorrected for temperature). Two regions of high heat flow are identified: 1) in western North Dakota along the North American Central Plains Conductivity Anomaly and 2) in eastern Montana near the Poplar dome. Within the sedimentary column in the center of the basin of the basin, an area of approximately 100,000 km2 is predicted to have moderate- to high-temperature geothermal resources (>90 °C) under the thickest sequences of sediments. Where thick insulation and high heat flow coincide, electric-grade resources can be less than 4 km deep. Assuming a maximum feasible drilling depth of 7 km, temperatures are predicted to be as high as 175 °C. The geologic model may be used to identify strata at sufficient temperatures that may have natural permeability or that may have conditions that favor development of enhanced/engineered geothermal systems resources.

Montana, North Dakota, South Dakota↗

Geophysical characterization of the Northwest Geysers geothermal field, California

The Clear Lake Volcanic Field in northern California is the youngest and northern-most part of a long-lived volcanic system that has produced recent (~10 ka) eruptions. Adjacent to the Clear Lake Volcanic Field is the worlds largest energy producing geothermal field, The Geysers. The hottest part of The Geysers geothermal field is in the northwest where temperatures reach ~400 C at 3 km depth. Low permeability, high thermal gradients, and low steam saturation prescribed development of an enhanced geothermal system (EGS) in the Northwest Geysers to increase energy producing capacity. Though the Northwest Geysers is known to be the hottest part of the field, geophysical methods have failed to adequately image any inferred heat source. This project aims to image the heat source of the Northwest Geysers using newly collected gravity and magnetotelluric (MT) measurements. Gravity data were jointly modeled with existing magnetic data along a two-dimensional profile aligned with an existing geologic cross-section. The key feature of the potential field model is a low-density, low-susceptibility body at 5 km depth (bmsl) under the EGS. MT data were modeled in three-dimensions to characterize subsurface resistivity structure, where the upper 3 km of the resistivity model agrees well with existing data. Lithologic and steam saturation are estimated from modeled resistivity values using existing geophysical data. Below 3 km depth (bmsl), the resistivity model images a possible young intrusion under the EGS. A possible zone of partial melt (<5%) below 7 km depth (bmsl) in the northwestern part of the field is also imaged which extends northeast towards the main part of the Clear Lake Volcanic Field.

California↗

Exploration drilling and reservoir model of the Platanares geothermal system, Honduras, Central America

Results of drilling, logging, and testing of three exploration core holes, combined with results of geologic and hydrogeochemical investigations, have been used to present a reservoir model of the Platanares geothermal system, Honduras. Geothermal fluids circulate at depths ??? 1.5 km in a region of active tectonism devoid of Quaternary volcanism. Large, artesian water entries of 160 to 165??C geothermal fluid in two core holes at 625 to 644 m and 460 to 635 m depth have maximum flow rates of roughly 355 and 560 l/min, respectively, which are equivalent to power outputs of about 3.1 and 5.1 MW(thermal). Dilute, alkali-chloride reservoir fluids (TDS ??? 1200 mg/kg) are produced from fractured Miocene andesite and Cretaceous to Eocene redbeds that are hydrothermally altered. Fracture permeabillity in producing horizons is locally greater than 1500 and bulk porosity is ??? 6%. A simple, fracture-dominated, volume-impedance model assuming turbulent flow indicates that the calculated reservoir storage capacity of each flowing hole is approximately 9.7 ?? 106 l/(kg cm-2), Tritium data indicate a mean residence time of 450 yr for water in the reservoir. Multiplying the natural fluid discharge rate by the mean residence time gives an estimated water volume of the Platanares system of ??? 0.78 km3. Downward continuation of a 139??C/km "conductive" gradient at a depth of 400 m in a third core hole implies that the depth to a 225??C source reservoir (predicted from chemical geothermometers) is at least 1.5 km. Uranium-thorium disequilibrium ages on calcite veins at the surface and in the core holes indicate that the present Platanares hydrothermal system has been active for the last 0.25 m.y. ?? 1991.

Journal of Volcanology and Geothermal Research↗

Can geologic factors be predictive for distinguishing between productive and non-productive geothermal wells?

Geologic data are examined to evaluate whether certain geologic characteristics occur in higher abundance or higher magnitude along production geothermal wells relative to non-productive wells. We perform 3D geologic mapping, 3D stress modeling, and fault-slip modeling to estimate fourteen different geologic factors that are hypothesized to control or correlate with well productivity. The geologic factors are; heat, fault-damage zone thickness, distance from active faults, fault intersection/termination density, fault curvature, slip tendency of faults, dilation tendency of faults, dilation resulting from modeled fault slip, normal stress reduction resulting from modeled fault slip, Coulomb shear stress increase resulting from modeled fault slip, the summed thickness of ‘favorable’ lithologies within a borehole, the summed thickness of fault damage zones in favorable lithologies within a borehole, the distance along the borehole to the nearest geologic contact, and the thickness of individual stratigraphic units. These geologic factors are quantified along fifty wells at Brady geothermal system, including twelve production wells and thirty-one non-productive wells. Results indicate that geologic factors such as stress changes associated with faulting, nearness to and thickness of fault zones, distance from geologic contacts, and heat occur in higher magnitude or higher abundance along production wells relative to non-productive wells. These geologic factors may play an important role in controlling the locations and distribution of fluid circulation in geothermal fields.

Geothermal Resources Council Transactions↗

Dynamics of permeability evolution in stimulated geothermal reservoirs

Spatially and temporally evolving permeability fields are fundamentally associated with the operation of enhanced geothermal systems. This chapter explores the resulting magnitude and patterns of permeability alteration as well as the coupled physical processes that control the evolution of permeability during shear stimulation and long-term evolution of a geothermal reservoir. It also explores mechanisms involved in the enhancement of fracture permeability, targeting injection pressures that encourage self-propping shear stimulation alongside elastic pressure and thermal dilatation of fracture sets. Simulation of a short-term, high-injection-rate enhanced geothermal system stimulation explored the importance of hydraulic versus thermal effects and the impact of a temperature differential between fluid in the fractures and the adjoining rock matrix. The effects of variations in fracture spacing on the evolution of permeability is at least as important as the magnitude of initial permeability, and quantifying the driving mechanisms is critical to understanding reservoir response.

Book chapter↗

Solute and geothermal flux monitoring using electrical conductivity in the Madison, Firehole, and Gibbon Rivers, Yellowstone National Park

The thermal output from the Yellowstone magma chamber can be estimated from the Cl flux in the major rivers in Yellowstone National Park; and by utilizing continuous discharge and electrical conductivity measurements the Cl flux can be calculated. The relationship between electrical conductivity and concentrations of Cl and other geothermal solutes (Na, SO 4 , F, HCO 3 , SiO 2 , K, Li, B, and As) was quantified at monitoring sites along the Madison, Gibbon, and Firehole Rivers, which receive discharge from some of the largest and most active geothermal areas in Yellowstone. Except for some trace elements, most solutes behave conservatively and the ratios between geothermal solute concentrations are constant in the Madison, Gibbon, and Firehole Rivers. Hence, dissolved concentrations of Cl, Na, SO 4 , F, HCO 3 , SiO 2 , K, Li, Ca, B and As correlate well with conductivity ( R 2 > 0.9 for most solutes) and most exhibit linear trends. The 2011 flux for Cl, SO 4 , F and HCO 3 determined using automated conductivity sensors and discharge data from nearby USGS gaging stations is in good agreement with those of previous years (1983–1994 and 1997–2008) at each of the monitoring sites. Continuous conductivity monitoring provides a cost- and labor-effective alternative to existing protocols whereby flux is estimated through manual collection of numerous water samples and subsequent chemical analysis. Electrical conductivity data also yield insights into a variety of topics of research interest at Yellowstone and elsewhere: (1) Geyser eruptions are easily identified and the solute flux quantified with conductivity data. (2) Short-term heavy rain events can produce conductivity anomalies due to dissolution of efflorescent salts that are temporarily trapped in and around geyser basins during low-flow periods. During a major rain event in October 2010, 180,000 kg of additional solute was measured in the Madison River. (3) The output of thermal water from the Gibbon River appears to have increased by about 0.2%/a in recent years, while the output of thermal water for the Firehole River shows a decrease of about 10% from 1983 to 2011. Confirmation of these trends will require continuing Cl flux monitoring over the coming decades.

Wyoming↗

Geothermal solute flux monitoring and the source and fate of solutes in the Snake River, Yellowstone National Park, WY

The combined geothermal discharge from over 10,000 features in Yellowstone National Park (YNP) can be can be estimated from the Cl flux in the Madison, Yellowstone, Falls, and Snake Rivers. Over the last 30 years, the Cl flux in YNP Rivers has been calculated using discharge measurements and Cl concentrations determined in discrete water samples and it has been determined that approximately 12% of the Cl flux exiting YNP is from the Snake River. The relationship between electrical conductivity and concentrations of Cl and other geothermal solutes was quantified at a monitoring site located downstream from the thermal inputs in the Snake River. Beginning in 2012, continuous (15 min) electrical conductivity measurements have been made at the monitoring site. Combining continuous electrical conductivity and discharge data, the Cl and other geothermal solute fluxes were determined. The 2013&ndash;2015 Cl fluxes (5.3&ndash;5.8 kt/yr) determined using electrical conductivity are comparable to historical data. In addition, synoptic water samples and discharge data were obtained from sites along the Snake River under low-flow conditions of September 2014. The synoptic water study extended 17 km upstream from the monitoring site. Surface inflows were sampled to identify sources and to quantify solute loading. The Lewis River was the primary source of Cl, Na, K, Cl, SiO 2 , Rb, and As loads (50&ndash;80%) in the Snake River. The largest source of SO 4 was from the upper Snake River (50%). Most of the Ca and Mg (50&ndash;55%) originate from the Snake Hot Springs. Chloride, Ca, Mg, Na, K, SiO 2 , F, HCO 3 , SO 4 , B, Li, Rb, and As behave conservatively in the Snake River, and therefore correlate well with conductivity (R 2 &ge; 0.97).

Wyoming↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: A U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

Arizona, Illinois, Maryland, Michigan, Mississippi↗

A new syringe pump apparatus for the retrieval and temporal analysis of helium in groundwaters and geothermal fluids

We present details of a newly designed syringe pump apparatus for the retrieval and temporal analysis of helium (SPARTAH). The device is composed of a commercially available syringe pump connected to coils of Cu tubing, which interface the syringe and the groundwater or geothermal wellhead. Through test deployments at geothermal wells in Iceland and California, we show that well fluids are drawn smoothly, accurately, and continuously into the Cu tubing and can be time‐stamped through user‐determined operating parameters. In the laboratory, the tubing is sectioned to reveal helium (He) characteristics of the fluids at times and for durations of interest. The device is capable of prolonged deployments, up to 6 months or more, with minimal maintenance. It can be used to produce detailed time series records of He, or any other geochemical parameter, in groundwaters and geothermal fluids. SPARTAH has application in monitoring projects assessing the relationship between external transient events (e.g., earthquakes) and geochemical signals in aqueous fluids.

Geochemistry, Geophysics, Geosystems↗

Three-dimensional seismic image of a geothermal reservoir: The Geysers, California

Three-dimensional seismic travel-time tomography of The Geysers geothermal area, in the coast ranges of northern California, shows a strong (−9%) anomaly in V P /V S , the ratio of the compressional and shear wave speeds, that is not evident in V P alone and corresponds closely to the most intensively exploited part of the geothermal reservoir. This anomaly probably indicates low pore pressure and relatively dry conditions, caused partly by boiling of pore water as steam is extracted. Steam pressure decreases over the last decade have probably caused seismologically measurable changes in wave speeds. Tomographic measurement of V P /V S is a promising technique both for identifying geothermal resources and for monitoring them during exploitation.

Geophysical Research Letters↗

Relatively stable pressure effects and time-increasing thermal contraction control Heber geothermal field deformation

Due to geological complexities and observational gaps, it is challenging to identify the governing physical processes of geothermal field deformation including ground subsidence and earthquakes. In the west and east regions of the Heber Geothermal Field (HGF), decade-long subsidence was occurring despite injection of heat-depleted brines, along with transient reversals between uplift and subsidence. These observed phenomena contradict current knowledge that injection leads to surface uplift. Here we show that high-yield production wells at the HGF center siphon fluid from surrounding regions, which can cause subsidence at low-rate injection locations. Moreover, the thermal contraction effect by cooling increases with time and eventually overwhelms the pressure effects of pressure fluctuation and poroelastic responses, which keep relatively stable during geothermal operations. The observed subsidence anomalies result from the siphoning effect and thermal contraction. We further demonstrate that thermal contraction dominates long-term trends of surface displacement and seismicity growth, while pressure effects drive near-instantaneous changes.

California↗

Integrated exploration for low-temperature geothermal resources in the Honey Lake Basin, California

An integrated exploration study is presented to locate low-temperature geothermal reservoirs in the Honey Lake area of northern California. Regional studies to locate the geothermal resources included gravity, infra-red, water-temperature, and water-quality analyses. Five anomalies were mapped from resistivity surveys. Additional study of three anomalies by temperature-gradient and seismic methods was undertaken to define structure and potential of the geothermal resource. The gravity data show a graben structure in the area. Seismic reflection data indicate faults associated with surface-resistivity and temperature-gradient data. The data support the interpretation that the shallow reservoirs are replenished along the fault zones by deeply circulating heated meteoric waters.

California↗