USGS Science⌕ Search

SEARCH · USGS Science

Results for “Fuel”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,243 records · Page 69Linked to original sources

Groundwater quality in the Western San Joaquin Valley study unit, 2010: California GAMA Priority Basin Project

Water quality in groundwater resources used for public drinking-water supply in the Western San Joaquin Valley (WSJV) was investigated by the USGS in cooperation with the California State Water Resources Control Board (SWRCB) as part of its Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. The WSJV includes two study areas: the Delta–Mendota and Westside subbasins of the San Joaquin Valley groundwater basin. Study objectives for the WSJV study unit included two assessment types: (1) a status assessment yielding quantitative estimates of the current (2010) status of groundwater quality in the groundwater resources used for public drinking water, and (2) an evaluation of natural and anthropogenic factors that could be affecting the groundwater quality. The assessments characterized the quality of untreated groundwater, not the quality of treated drinking water delivered to consumers by water distributors. The status assessment was based on data collected from 43 wells sampled by the U.S. Geological Survey for the GAMA Priority Basin Project (USGS-GAMA) in 2010 and data compiled in the SWRCB Division of Drinking Water (SWRCB-DDW) database for 74 additional public-supply wells sampled for regulatory compliance purposes between 2007 and 2010. To provide context, concentrations of constituents measured in groundwater were compared to U.S. Environmental Protection Agency (EPA) and SWRCB-DDW regulatory and non-regulatory benchmarks for drinking-water quality. The status assessment used a spatially weighted, grid-based method to estimate the proportion of the groundwater resources used for public drinking water that has concentrations for particular constituents or class of constituents approaching or above benchmark concentrations. This method provides statistically unbiased results at the study-area scale within the WSJV study unit, and permits comparison of the two study areas to other areas assessed by the GAMA Priority Basin Project statewide. Groundwater resources used for public drinking water in the WSJV study unit are among the most saline and most affected by high concentrations of inorganic constituents of all groundwater resources used for public drinking water that have been assessed by the GAMA Priority Basin Project statewide. Among the 82 GAMA Priority Basin Project study areas statewide, the Delta–Mendota study area ranked above the 90th percentile for aquifer-scale proportions of groundwater resources having concentrations of total dissolved solids (TDS), sulfate, chloride, manganese, boron, chromium(VI), selenium, and strontium above benchmarks, and the Westside study area ranked above the 90th percentile for TDS, sulfate, manganese, and boron. In the WSJV study unit as a whole, one or more inorganic constituents with regulatory or non-regulatory, health-based benchmarks were present at concentrations above benchmarks in about 53 percent of the groundwater resources used for public drinking water, and one or more organic constituents with regulatory health-based benchmarks were detected at concentrations above benchmarks in about 3 percent of the resource. Individual constituents present at concentrations greater than health-based benchmarks in greater than 2 percent of groundwater resources used for public drinking water included: boron (51 percent, SWRCB-DDW notification level), chromium(VI) (25 percent, SWRCB-DDW maximum contaminant level (MCL)), arsenic (10 percent, EPA MCL), strontium (5.1 percent, EPA Lifetime health advisory level (HAL)), nitrate (3.9 percent, EPA MCL), molybdenum (3.8 percent, EPA HAL), selenium (2.6 percent, EPA MCL), and benzene (2.6 percent, SWRCB-DDW MCL). In addition, 50 percent of the resource had TDS concentrations greater than non-regulatory, aesthetic-based SWRCB-DDW upper secondary maximum contaminant level (SMCL), and 44 percent had manganese concentrations greater than the SWRCB-DDW SMCL. Natural and anthropogenic factors that could affect the groundwater quality were evaluated by using results from statistical testing of associations between constituent concentrations and values of potential explanatory factors, inferences from geochemical and age-dating tracer results, and by considering the water-quality results in the context of the hydrogeologic setting of the WSJV study unit. Natural factors, particularly the lithologies of the source areas for groundwater recharge and of the aquifers, were the dominant factors affecting groundwater quality in most of the WSJV study unit. However, where groundwater resources used for public supply included groundwater recharged in the modern era, mobilization of constituents by recharge of water used for irrigation also affected groundwater quality. Public-supply wells in the Westside study area had a median depth of 305 m and primarily tapped groundwater recharged hundreds to thousands of years ago, whereas public-supply wells in the Delta–Mendota study area had a median depth of 85 m and primarily tapped either groundwater recharged within the last 60 years or groundwater consisting of mixtures of this modern recharge and older recharge. Public-supply wells in the WSJV study unit are screened in the Tulare Formation and zones above and below the Corcoran Clay Member are used. The Tulare Formation primarily consists of alluvial sediments derived from the Coast Ranges to the west, except along the valley trough at the eastern margin of the WSJV study unit where the Tulare Formation consists of fluvial sands derived from the Sierra Nevada to the east. Groundwater from wells screened in the Sierra Nevada sands had manganese-reducing or manganese- and iron-reducing oxidation-reduction (redox) conditions. These redox conditions commonly were associated with elevated arsenic or molybdenum concentrations, and the dominance of arsenic(III) in the dissolved arsenic supports reductive dissolution of iron and manganese oxyhydroxides as the mechanism. In addition, groundwater from many wells screened in Sierra Nevada sands contained low concentrations of nitrite or ammonium, indicating reduction of nitrate by denitrification or dissimilatory processes, respectively. Geology of the Coast Ranges westward of the study unit strongly affects groundwater quality in the WSJV. Elevated concentrations of TDS, sulfate, boron, selenium and strontium in groundwater were primarily associated with aquifer sediments and recharge derived from areas of the Coast Ranges dominated by Cretaceous-to-Miocene age, organic-rich, reduced marine shales, known as the source of selenium in WSJV soils, surface water, and groundwater. Low sulfur-isotopic values (δ34S) of dissolved sulfate indicate that the sulfate was largely derived from oxidation of biogenic pyrite from the shales, and correlations with trace element concentrations, geologic setting, and groundwater geochemical modeling indicated that distributions of sulfate, strontium, and selenium in groundwater were controlled by dissolution of secondary sulfate minerals in soils and sediments. Elevated concentrations of chromium(VI) were primarily associated with aquifer sediments and recharge derived from areas of the Coast Ranges dominated by the Franciscan Complex and ultramafic rocks. The Franciscan Complex also has boron-rich, sodium-chloride dominated hydrothermal fluids that contribute to elevated concentrations of boron and TDS. Groundwater from wells screened in Coast Ranges alluvium was primarily oxic and relatively alkaline (median pH value of 7.55) in the Delta–Mendota study area, and primarily nitrate-reducing or suboxic and alkaline (median pH value of 8.4) in the Westside study area. Many groundwater samples from those wells have elevated concentrations of arsenic(V), molybdenum, selenium, or chromium(VI), consistent with desorption of metal oxyanions from mineral surfaces under those geochemical conditions. High concentrations of benzene were associated with deep wells located in the vicinity of petroleum deposits at the southern end of the Westside study area. Groundwater from these wells had premodern age and anoxic geochemical conditions, and the ratios among concentrations of hydrocarbon constituents were different from ratios found in fuels and combustion products, which is consistent with a geogenic source for the benzene rather than contamination from anthropogenic sources. Water stable-isotope compositions, groundwater recharge temperatures, and groundwater ages were used to infer four types of groundwater: (1) groundwater derived from natural recharge of water from major rivers draining the Sierra Nevada; (2) groundwater primarily derived from natural recharge of water from Coast Ranges runoff; (3) groundwater derived from recharge of pumped groundwater applied to the land surface for irrigation; and (4) groundwater derived from recharge during a period of much cooler paleoclimate. Water previously used for irrigation was found both above and below the Corcoran Clay, supporting earlier inferences that this clay member is no longer a robust confining unit. Recharge of water used for irrigation has direct and indirect effects on groundwater quality. Elevated nitrate concentrations and detections of herbicides and fumigants in the Delta–Mendota study area generally were associated with greater agricultural land use near the well and with water recharged during the last 60 years. However, the extent of the groundwater resource affected by agricultural sources of nitrate was limited by groundwater redox conditions sufficient to reduce nitrate. The detection frequency of perchlorate in Delta–Mendota groundwater was greater than expected for natural conditions. Perchlorate, nitrate, selenium, and strontium concentrations were correlated with one another and were greater in groundwater inferred to be recharge of previously pumped groundwater used for irrigation. The source of the perchlorate, selenium, and strontium appears to be salts deposited in the soils and sediments of the arid WSJV that are dissolved and flushed into groundwater by the increased amount of recharge caused by irrigation. In the Delta–Mendota study area, the groundwater with elevated concentrations of selenium was found deeper in the aquifer system than it was reported by a previous study 25 years earlier, suggesting that this transient front of groundwater with elevated concentrations of constituents derived from dissolution of soil salts by irrigation recharge is moving down through the aquifer system and is now reaching the depth zone used for public drinking water supply.

California↗

Status and understanding of groundwater quality in the Bear Valley and Lake Arrowhead Watershed Study Unit, 2010: California GAMA Priority Basin Project

Groundwater quality in the 112-square-mile Bear Valley and Lake Arrowhead Watershed (BEAR) study unit was investigated as part of the Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The study unit comprises two study areas (Bear Valley and Lake Arrowhead Watershed) in southern California in San Bernardino County. The GAMA-PBP is conducted by the California State Water Resources Control Board (SWRCB) in cooperation with the U.S. Geological Survey (USGS) and the Lawrence Livermore National Laboratory. The GAMA BEAR study was designed to provide a spatially balanced, robust assessment of the quality of untreated (raw) groundwater from the primary aquifer systems in the two study areas of the BEAR study unit. The assessment is based on water-quality collected by the USGS from 38 sites (27 grid and 11 understanding) during 2010 and on water-quality data from the SWRCB-Division of Drinking Water (DDW) database. The primary aquifer system is defined by springs and the perforation intervals of wells listed in the SWRCB-DDW water-quality database for the BEAR study unit. This study included two types of assessments: (1) a status assessment , which characterized the status of the quality of the groundwater resource as of 2010 by using data from samples analyzed for volatile organic compounds, pesticides, and naturally present inorganic constituents, such as major ions and trace elements, and (2) an understanding assessment , which evaluated the natural and human factors potentially affecting the groundwater quality. The assessments were intended to characterize the quality of groundwater resources in the primary aquifer system of the BEAR study unit, not the treated drinking water delivered to consumers. Bear Valley study area and the Lake Arrowhead Watershed study area were also compared statistically on the basis of water-quality results and factors potentially affecting the groundwater quality. Relative concentrations (RCs), which are sample concentration of a particular constituent divided by its associated health- or aesthetic-based benchmark concentrations, were used for evaluating the groundwater quality for those constituents that have Federal or California regulatory or non-regulatory benchmarks for drinking-water quality. An RC greater than 1.0 indicates a concentration greater than a benchmark. Organic (volatile organic compounds and pesticides) and special-interest (perchlorate) constituent RCs were classified as “high” (RC greater than 1.0), “moderate” (RC less than or equal to 1.0 and greater than 0.1), or “low” (RC less than or equal to 0.1). For inorganic (radioactive, trace element, major ion, and nutrient) constituents, the boundary between low and moderate RCs was set at 0.5. Aquifer-scale proportion was used as the primary metric in the status assessment for evaluating groundwater quality at the study-unit scale or for its component areas. High aquifer-scale proportion was defined as the percentage of the area of the primary aquifer system with a RC greater than 1.0 for a particular constituent or class of constituents; the percentage is based on area rather than volume. Moderate and low aquifer-scale proportions were defined as the percentage of the primary aquifer system with moderate and low RCs, respectively. A spatially weighted statistical approach was used to evaluate aquifer-scale proportions for individual constituents and classes of constituents. The status assessment for the Bear Valley study area found that inorganic constituents with health-based benchmarks were detected at high RCs in 9.0 percent of the primary aquifer system and at moderate RCs in 13 percent. The high RCs of inorganic constituents primarily reflected high aquifer-scale proportions of fluoride (in 5.4 percent of the primary aquifer system) and arsenic (3.6 percent). The RCs of organic constituents with health-based benchmarks were high in 1.0 percent of the primary aquifer system, moderate in 8.1 percent, and low in 70 percent. Organic constituents were detected in 79 percent of the primary aquifer system. Two groups of organic constituents and two individual organic constituents were detected at frequencies greater than 10 percent of samples from the USGS grid sites: trihalomethanes (THMs), solvents, methyl tert -butyl ether (MTBE), and simazine. The special-interest constituent perchlorate was detected in 93 percent of the primary aquifer system; it was detected at moderate RCs in 7.1 percent and at low RCs in 86 percent. The status assessment in the Lake Arrowhead Watershed study area showed that inorganic constituents with human-health benchmarks were detected at high RCs in 25 percent of the primary aquifer system and at moderate RCs in 41 percent. The high aquifer-scale proportion of inorganic constituents primarily reflected high aquifer-scale proportions of radon‑222 (in 62 percent of the primary aquifer system) and uranium (26 percent). RCs of organic constituents with health-based benchmarks were moderate in 7.7 percent of the primary aquifer system and low in 46 percent. Organic constituents were detected in 54 percent of the primary aquifer system. The only organic constituents that were detected at frequencies greater than 10 percent of samples from the USGS grid sites were THMs. Perchlorate was detected in 62 percent of the primary aquifer system at uniformly low RCs. The second component of this study, the understanding assessment , identified the natural and human factors that could have affected the groundwater quality in the BEAR study unit by evaluating statistical correlations between water-quality constituents and potential explanatory factors. The potential explanatory factors evaluated were land use (including density of septic tanks and leaking or formerly leaking underground fuel tanks), site type, aquifer lithology, well construction (well depth and depth to the top-of-perforated interval), elevation, aridity index, groundwater-age distribution, and oxidation-reduction condition (including pH and dissolved oxygen concentration). Results of the statistical evaluations were used to explain the distribution of constituents in groundwater of the BEAR study unit. In the Bear Valley study area, high and moderate RCs of fluoride were found in sites known to be influenced by hydrothermic conditions or that had high concentrations of fluoride historically. The high RC of arsenic can likely be attributed to desorption of arsenic from aquifer sediments saturated in old groundwater with high pH under reducing conditions. The THMs were detected more frequently at USGS grid sites that were wells, part of a large urban water system, and surrounded by urban land use. Solvents, MTBE, and simazine were all detected more frequently at USGS grid sites that were wells with a greater urban percentage of surrounding land use and that accessed older groundwater than other USGS grid sites. Comparison between the observed and predicted detection frequencies of perchlorate at USGS grid sites indicated that anthropogenic sources could have contributed to low levels of perchlorate in the groundwater of the Bear Valley study area. In the Lake Arrowhead Watershed study area, high and moderate RCs of radon-222 and uranium can be attributed to older groundwater from the granitic fractured-rock primary aquifer system. Low RCs of THMs were detected at USGS grid sites that were wells and part of small water systems. The similarities between the observed and predicted detection frequencies of perchlorate in samples from USGS grid sites indicated that the source and distribution of perchlorate were most likely attributable to precipitation (rain and snow), with minimal, if any, contribution from anthropogenic sources.

California↗

Carbon dioxide enhanced oil recovery performance according to the literature

Introduction The need to increase the efficiency of oil recovery and environmental concerns are bringing to prominence the use of carbon dioxide (CO 2 ) as a tertiary recovery agent. Assessment of the impact of flooding with CO 2 all eligible reservoirs in the United States not yet undergoing enhanced oil recovery (EOR) requires making the best possible use of the experience gained in 40 years of applications. Review of the publicly available literature has located relevant CO 2 -EOR information for 53 units (fields, reservoirs, pilot areas) in the United States and 17 abroad. As the world simultaneously faces an increasing concentration of CO 2 in the atmosphere and a higher demand for fossil fuels, the CO 2 -EOR process continues to gain popularity for its efficiency as a tertiary recovery agent and for the potential for having some CO 2 trapped in the subsurface as an unintended consequence of the enhanced production (Advanced Resources International and Melzer Consulting, 2009). More extensive application of CO 2 -EOR worldwide, however, is not making it significantly easier to predict the exact outcome of the CO 2 flooding in new reservoirs. The standard approach to examine and manage risks is to analyze the intended target by conducting laboratory work, running simulation models, and, finally, gaining field experience with a pilot test. This approach, though, is not always possible. For example, assessment of the potential of CO 2 -EOR at the national level in a vast country such as the United States requires making forecasts based on information already available. Although many studies are proprietary, the published literature has provided reviews of CO 2 -EOR projects. Yet, there is always interest in updating reports and analyzing the information under new perspectives. Brock and Bryan (1989) described results obtained during the earlier days of CO 2 -EOR from 1972 to 1987. Most of the recovery predictions, however, were based on intended injections of 30 percent the size of the reservoir’s hydrocarbon pore volume (HCPV), and the predictions in most cases badly missed the actual recoveries because of the embryonic state of tertiary recovery in general and CO 2 flooding in particular at the time. Brock and Bryan (1989), for example, reported for the Weber Sandstone in the Rangely oil field in Colorado, an expected recovery of 7.5 percent of the original oil in place (OOIP) after injecting a volume of CO 2 equivalent to 30 percent of the HCPV, but Clark (2012) reported that after injecting a volume of CO 2 equivalent to 46 percent of the HCPV, the actual recovery was 4.8 percent of the OOIP. Decades later, the numbers by Brock and Bryan (1989) continue to be cited as part of expanded reviews, such as the one by Kuuskraa and Koperna (2006). Other comprehensive reviews including recovery factors are those of Christensen and others (2001) and Lake and Walsh (2008). The Oil and Gas Journal (O&GJ) periodically reports on active CO 2 -EOR operations worldwide, but those releases do not include recovery factors. The monograph by Jarrell and others (2002) remains the most technically comprehensive publication on CO 2 flooding, but it does not cover recovery factors either. This chapter is a review of the literature found in a search for information about CO 2 -EOR. It has been prepared as part of a project by the U.S. Geological Survey (USGS) to assess the incremental oil production that would be technically feasible by CO 2 flooding of all suitable oil reservoirs in the country not yet undergoing tertiary recovery.

Scientific Investigations Report↗

Hydraulic and water-quality indicators of aquifer zones contributing groundwater flow to wells in the Santa Fe Group aquifer system near southeast Albuquerque, New Mexico, 2013–16

An ethylene dibromide (EDB) plume extends approximately 5,880 feet northeast from the Bulk Fuels Facility on Kirtland Air Force Base. The leading edge of the EDB plume is about 3,700 feet upgradient from several water-supply wells. The water-supply wells are screened in the upper Santa Fe Group aquifer system. Within the upper Santa Fe Group, two primary clay-rich layers, the A1 and A2 units, separate water-producing zones. The U.S. Geological Survey, in cooperation with the Albuquerque Bernalillo County Water Utility Authority and the U.S. Air Force, installed four sentinel well nests and two aquifer-test pumping wells between the EDB plume and the water-supply wells. The purpose of the sentinel wells is to provide early warning of EDB plume migration towards water-supply wells. The sentinel well nests include at least three wells that are screened above, in between, and below the A1 and A2 units. The two aquifer-test pumping wells, installed for performing hydraulic tests on the aquifer system, are screened across both clay layers, as are the nearby water-supply wells. Well-bore flow logging indicated that greater than 60 percent of groundwater flow to the wells was through the deepest interval below the lowermost clay layer (A1 unit). The interval between the A1 and A2 units is the second most productive interval. Water-quality data also indicated that water drawn from the aquifer-test pumping wells and previously studied nearby water-supply wells is most similar in composition to water from the sentinel wells screened in the middle and deep intervals.

New Mexico↗

Occurrence, fate, and transport of aerially applied herbicides to control invasive buffelgrass within Saguaro National Park Rincon Mountain District, Arizona, 2015–18

The spread of the invasive and fire-adapted buffelgrass ( Cenchrus ciliaris L.) threatens desert ecosystems by competing for resources, increasing fuel loads, and creating wildfire connectivity. The Rincon Mountain District of Saguaro National Park addressed this natural resource threat with the use of glyphosate-based herbicides (GBHs). In 2010, the Rincon Mountain District initiated an aerial restoration plan to control dense buffelgrass patches in remote areas and implemented a trial project to evaluate the effects of aerial restoration techniques that included the helicopter application of GBHs. In 2014, more than 250 acres of buffelgrass in the Rincon Mountain District were treated with the aerial application of GBHs. This widespread aerial application of GBHs continued through 2018, but the potential transport and effects to aquatic ecosystems were unknown. In 2015–18, the U.S. Geological Survey, in cooperation with the National Park Service, studied the occurrence, distribution, fate, and transport of glyphosate in surface water and sediments derived from areas that were treated during past and current aerial herbicide applications. Three watersheds, treated with different regimens of GBHs, were sampled for glyphosate and the primary metabolite of glyphosate, aminomethylphosphonic acid (AMPA), during various hydrologic flow conditions. Water and aquatic sediment were collected from three watersheds, each in a different stage of application during the U.S. Geological Survey study. The unnamed watershed above the Loma Verde Trailhead referred to by the National Park Service as “Loma Verde canyon” had received no aerial treatment since 2014, whereas the Box Canyon watershed was aerially treated every year beginning in 2014. The Madrona Canyon watershed was first sprayed in 2016 and aerial application continued once a year though the entirety of the study. In addition, terrestrial soil samples were sampled from areas sprayed to understand dissipation rates and herbicide transport via sediments washing away during rainfall runoff. The concentrations present in water and sediment samples were compared to ecological benchmarks and characterized within the context of the environmental conditions of the park setting. Of the 48 water samples collected and analyzed for glyphosate and AMPA, 10.4 percent and 14.6 percent were detected above the laboratory minimum detection limit, respectively. Mean water concentrations, calculated using specific statistical methods for non-detects, were equal to the laboratory minimum detection limit of 0.02 microgram per liter for samples collected in all the watersheds. In aquatic sediments, glyphosate and AMPA were detected in 10.7 and 25.0 percent of the samples, whereas 89.5 and 100 percent of the terrestrial soil samples had detections for glyphosate and AMPA, respectively. Mean aquatic sediment concentrations were 1.13 and 4.42 micrograms per kilogram (μg/kg) for glyphosate and AMPA, respectively. Mean terrestrial soil concentrations were orders of magnitude greater than water and aquatic sediment with concentrations of 678 μg/kg for AMPA and 1,240 μg/kg for glyphosate. Hours after glyphosate-based herbicide was applied, the concentrations of glyphosate and AMPA were present in terrestrial soil samples near or above the laboratory maximum detection limit of 5,000 μg/kg. The Box Canyon watershed was the most intensively treated watershed in terms of total land area treated, total amount of GBH applied, and number of years treated. The frequent and large volume of treatment resulted in the highest number of detections of glyphosate and AMPA in water (3 and 7 detections, respectively) and in aquatic sediment (2 and 6 detections, respectively) samples. In comparison, the other two watersheds had two or fewer detections for glyphosate and AMPA in water and aquatic sediment. Glyphosate detected in pools was associated with increased rainfall closer in time to the last herbicide treatment. Glyphosate and AMPA concentration ratios above one, along with stable-isotope and tritium results, indicated that runoff processes were the primary transport mechanism for the two compounds when found in streams and pools rather than subsurface recharge or deeper flow paths. One pool in a small tributary of Box Canyon consistently had detections of glyphosate and AMPA in aquatic sediments, but these frequent concentrations were likely related to the intensive application upstream, near the steep terrain above the head of the channel that supplies the downstream pool. Intense flows during summer rainfall events move treated sediments into this channel where vegetation and the incised bedrock banks of the pool retained those sediments and ultimately led to frequent detections of both compounds. Isotope results in most of the pools and tinajas indicated that the water source had residence time representative of recently recharged waters, on the order of years. No water concentrations exceeded published criteria for human health or aquatic life. Median and maximum glyphosate and AMPA water concentrations were lower than those reported in other national assessments, but maximum concentrations observed in individual runoff samples were higher than median concentrations measured in the national assessments. A similar finding was observed with aquatic sediment concentrations measured in the Rincon Mountain District. Results from the study were compared and assessed in the context of other studies examining GBHs and their effects on amphibians, fish, and macroinvertebrates. This comparison was used to generalize the potential risk to aquatic species similar to those species in the Rincon Mountain District. Concentrations of published effect levels were several orders of magnitude greater than the highest concentration detected in water at the Rincon Mountain District. Most published studies evaluate acute and chronic toxicity for glyphosate and GBHs, and these criteria may not be representative of environmental conditions in the Rincon Mountain District. The classic lethal dose studies conducted in a controlled laboratory setting may not be suitable for comparison to the longer, variable, low-dose exposure conditions in the pools and tinajas in the Rincon Mountain District. However, this study determined that the fate of GBHs transported from treated areas to potential aquatic habitat was highly variable in occurrence, timing, and concentrations. This variability in glyphosate concentrations was too high, and the potential exposure was determined to be far too complex to directly compare with the results from controlled studies. This study provides the first information collected on GBHs used to control invasive buffelgrass in a remote, mountainous, and semiarid setting. The information about the transport and fate of herbicide application near aquatic habitat will help to inform managers about the broader ecosystem implications and provide useful information to other agencies implementing buffelgrass remediation strategies near aquatic habitat.

Arizona↗

Comparison of passive and pumped sampling methods for analysis of groundwater quality, Kirtland Air Force Base, Albuquerque, New Mexico, 2019

A plume of ethylene dibromide (EDB) dissolved in groundwater extends northeast from the Bulk Fuels Facility on Kirtland Air Force Base, New Mexico. The leading edge of the EDB plume is upgradient from several water-supply wells. In 2013, the U.S. Geological Survey (USGS), in cooperation with the Albuquerque Bernalillo County Water Utility Authority and the U.S. Air Force, installed four sentinel well nests and two aquifer-test pumping wells between the EDB plume and the water-supply wells to serve as an early warning if the plume travels toward the water-supply wells. Since 2015, the USGS has used submersible pumps to sample the sentinel wells quarterly. In February 2017, the USGS began using dual-membrane passive diffusion bag samplers for quarterly sampling in the wells. To ensure that the passive samplers are obtaining representative samples of the groundwater contaminants, the USGS, in cooperation with the U.S. Air Force, initiated a study in 2019 to compare results from pump sampling and passive samplers and to use vertical profiling to determine the optimal depth for passive sampler placement in the screened interval to better inform long-term monitoring of the site. Vertical profiling included deploying passive samplers throughout the submerged screened interval of four shallow sentinel wells. After retrieval of the passive samplers, pump samples were collected. The results of analyses of both types of samples were compared. Volatile organic compound results for this study were all below the raised reporting levels, which is a level five times the maximum concentration detected in a blank and determined by an in-depth quality assessment; therefore, this study focused on inorganic constituent results, including major ions, trace elements, and stable isotopes of water, to calculate the relative percent difference (RPD) between the pump and passive sampling method results as a way to determine where passive samplers would be best placed in each of the wells. Several analytes had an RPD of more than plus or minus 50 percent, and several analytes were not within the estimated variability for each sampling method. Additionally, the variability within each sampling method was quantified and compared. Factors that likely contributed to the lack of comparison between each sampling method included temporal variability, flow regime, volume of sample integrated through different aquifer intervals, and reduction/oxidation processes. RPD and method variability were used to determine the intervals within each well with the greatest agreement between sampling methods. Optimal sampling depths for each well were then correlated to the intervals where quarterly sampling has been occurring.

New Mexico↗

Potential effects of projected pumping scenarios on future water-table elevations near Kirtland Air Force Base in Albuquerque, New Mexico

The U.S. Geological Survey, in cooperation with the Air Force Civil Engineer Center, simulated different groundwater pumping scenarios from 2016 to 2050 to determine the potential future changes in groundwater levels in areas around the Kirtland Air Force Base Bulk Fuels Facility and an ethylene dibromide (EDB) plume. Projections of water supply and demand created by the Albuquerque Bernalillo County Water Utility Authority were used to develop the future groundwater pumping scenarios used as inputs for a refined local-scale model within the updated Middle Rio Grande Basin regional model. The simulated water-table elevations in model cells that contain the EDB plume in the medium demand and medium supply scenario rose 29 feet (ft) until 2035, then remained within 10 ft of that elevation through 2050, whereas the water-table elevations in the high demand and low supply scenario rose about 26 ft until 2035 and then decreased by more than 10 ft. Simulated water-table elevations in the low demand and high supply scenario continued to rise throughout most of the future simulation period and peaked at about 44 ft over the 2016 water-table elevation. All of the scenarios ended the future simulation period with higher simulated water-table elevations than at the beginning of the future simulation period. Simulations that represented the potentially highest and lowest volume of groundwater pumping near the EDB plume by adjusting the spatial distribution of pumping had similar simulated water-table elevations as the nonadjusted scenarios, with maximum water-table elevation changes that only differed by about 2 ft from the nonadjusted scenarios. Consideration should be taken when using these model results to inform decisions because the model results are subject to uncertainty from many different sources, including uncertainty in the future pumping scenarios as well as the model itself because of the simplification of the hydrogeologic system.

New Mexico↗

Climate change impacts on plant communities in the sagebrush region—A science synthesis to inform Bureau of Land Management resource management

This report synthesizes current (2024) science-based knowledge related to the impacts of climate change on big sagebrush vegetation in Western North America. This effort was conducted through the U.S. Geological Survey working with the Bureau of Land Management as part of multiple science syntheses to aid management agencies developing environmental impacts assessments in response to human-related or caused events. This report reviews the potential impacts climate change may have on sagebrush vegetation and related management decisions. The body of the synthesis introduces the diverse impacts of climate change across the region by first focusing directly on what climate change may entail in terms of altered temperature and precipitation patterns. The report then discusses how these changes could likely affect individual plant species based on experimental results and scale the impacts to species distributions and community composition. The synthesis section ends by surveying efforts to model potential future changes in habitat. The report goes on to link the synthesis conclusions to individual land uses or land management decisions, such as forage resources, restoration or fuel treatment. Finally, the report provides a section that discusses the pros and cons of available datasets that model the potential future of vegetation in the sagebrush region.

Arizona, California, Colorado, Idaho, Montana, Nev↗

Mineralogy and geochemistry of a uraniferous coal from the Red Desert Area, Sweetwater County, Wyoming

A sample of subbituminous uraniferous coal from the Red Desert, Sweetwater County, Wyo., was studied mineralogically. The coal contains gypsum (6 percent), kaolinite (1 percent), quartz (0.3 percent), calcite (trace), and limonite (trace). This suite of minerals and the absence of pyrite show that the coal has been subjected to weathering and oxidation. No uranium minerals have been found; mechanical fractionation has indicated that the uranium is associated with the organic constituents of the coal. The minerals that have been isolated contain 0.0006 percent uranium, a content which is to be expected for nonuraniferous sedimentary rocks. The organic components of the coal contain approximately 0.002 percent uranium. On the basis of material balance calculations, the organic components carry 98 percent of the uranium in the coal. Fischer assays of this weathered coal from the Red Desert indicate a yield of 16.7 gallons of tar per ton on low-temperature retorting. In view of the large reserve of subbituminous coal in the Red Desert, its probable ease of mining, and its tar yield, it may be desirable to carry out further evaluation of the coal as a fuel or raw material for the manufacture of tar or chemicals. If economic factors permit utilization of the coal, the uranium, although present in small percentages, could be recovered as a byproduct.

Wyoming↗

Results of core drilling for uranium-bearing lignite, Mendenhall area, Harding County, South Dakota

Core drilling for data on uranium-bearing lignite in the Mendenhall area, Harding County, S. Dak. , was conducted by the U. S. Bureau of Mines during the period October 1952 to July 1953. Forty-two core holes totaling 9, 683 feet drilled in an area of about six square miles indicate a reserve of about 127/000,000 tons of lignite of which about 49,000,000 tons contain an average of 0.005 percent uranium or more. The Mendenhall area is near the center of the Slim Buttes, which are about 30 miles long from north to south. The uranium-bearing lignite averages, 5. 4 feet in thickness and occurs in the Ludlow member of the Fort Union formation of Paleocene age. Fuel analyses of about 130 samples indicate that the lignite contains about 15 percent ash, 36.7 percent moisture, 24r percent fixed carbon, 23.9 percent volatile matter, and 1.5 percent sulfur and has heating values of about 5,800 btu (as received). Uranium analyses of about 700 samples of lignite core indicate that about 2, 790 tons of uranium are present in the Mendenhall area. Inferred uranium reserves of 2,335 and .1. 050 tons are indicated by grade cutoffs of 0. 005 and 0. 01 percent uranium in the lignites, and 2, 065 and l s 35Stons are indicated by grade cutoffs of 0.03 and 0.05 percent uranium in the lignite ash. The above grade cutoffs have been incorporated on maps showing areal distribution: and thickness of mineralized beds.

South Dakota↗

Guidelines for the use of the semipermeable membrane device (SPMD) and the polar organic chemical integrative sampler (POCIS) in environmental monitoring studies

The success of an environmental monitoring study using passive samplers, or any sampling method, begins in the office or laboratory. Regardless of the specific methods used, the general steps include the formulation of a sampling plan, training of personnel, performing the field (sampling) work, processing the collected samples to recover chemicals of interest, analysis of the enriched extracts, and interpretation of the data. Each of these areas will be discussed in the following sections with emphasis on specific considerations with the use of passive samplers. Water is an extremely heterogeneous matrix both spatially and temporally (Keith, 1991). The mixing and distribution of dissolved organic chemicals in a water body are controlled by the hydrodynamics of the water, the sorption partition coefficients of the chemicals, and the amount of organic matter (suspended sediments, colloids, and dissolved organic carbon) present. In lakes and oceans, stratification because of changes in temperature, water movement, and water composition can occur resulting in dramatic changes in chemical concentrations with depth (Keith, 1991). Additional complications related to episodic events, such as surface runoff, spills, and other point source contamination, can result in isolated or short-lived pulses of contaminants in the water. The application of passive sampling technologies for the monitoring of legacy and emerging organic chemicals in the environment is becoming widely accepted worldwide. The primary use of passive sampling methods for environmental studies is in the area of surface-water monitoring; however, these techniques have been applied to air and groundwater monitoring studies. Although these samplers have no mechanical or moving parts, electrical or fuel needs which require regular monitoring, there are still considerations that need to be understood in order to have a successful study. Two of the most commonly used passive samplers for organic contaminants are the semipermeable membrane device (SPMD) and the polar organic chemical integrative sampler (POCIS). The tips given in this document focus on these two samplers but are applicable to most types of passive sampling devices. The information in this guide is heavily weighted towards the sampling of water; however, information specific to the use of SPMDs for air sampling will also be covered.

Techniques and Methods↗

Occurrence and distribution of methyl tert-butyl ether and other volatile organic compounds in drinking water in the Northeast and Mid-Atlantic regions of the United States, 1993-98

Data on volatile organic compounds (VOCs) in drinking water supplied by 2,110 randomly selected community water systems (CWSs) in 12 Northeast and Mid-Atlantic States indicate 64 VOC analytes were detected at least once during 1993-98. Selection of the 2,110 CWSs inventoried for this study targeted 20 percent of the 10,479 active CWSs in the region and represented a random subset of the total distribution by State, source of water, and size of system. The data include 21,635 analyses of drinking water collected for compliance monitoring under the Safe Drinking Water Act; the data mostly represent finished drinking water collected at the pointof- entry to, or at more distal locations within, each CWS?s distribution system following any watertreatment processes. VOC detections were more common in drinking water supplied by large systems (serving more than 3,300 people) that tap surface-water sources or both surface- and groundwater sources than in small systems supplied exclusively by ground-water sources. Trihalomethane (THM) compounds, which are potentially formed during the process of disinfecting drinking water with chlorine, were detected in 45 percent of the randomly selected CWSs. Chloroform was the most frequently detected THM, reported in 39 percent of the CWSs. The gasoline additive methyl tert-butyl ether (MTBE) was the most frequently detected VOC in drinking water after the THMs. MTBE was detected in 8.9 percent of the 1,194 randomly selected CWSs that analyzed samples for MTBE at any reporting level, and it was detected in 7.8 percent of the 1,074 CWSs that provided MTBE data at the 1.0-?g/L (microgram per liter) reporting level. As with other VOCs reported in drinking water, most MTBE concentrations were less than 5.0 ?g/L, and less than 1 percent of CWSs reported MTBE concentrations at or above the 20.0-?g/L lower limit recommended by the U.S. Environmental Protection Agency?s Drinking-Water Advisory. The frequency of MTBE detections in drinking water is significantly related to high- MTBE-use patterns. Detections are five times more likely in areas where MTBE is or has been used in gasoline at greater than 5 percent by volume as part of the oxygenated or reformulated (OXY/RFG) fuels program. Detection frequencies of the individual gasoline compounds (benzene, toluene, ethylbenzene, and xylenes (BTEX)) were mostly less than 3 percent of the randomly selected CWSs, but collectively, BTEX compounds were detected in 8.4 percent of CWSs. BTEX concentrations also were low and just three drinkingwater samples contained BTEX at concentrations exceeding 20 ?g/L. Co-occurrence of MTBE and BTEX was rare, and only 0.8 percent of CWSs reported simultaneous detections of MTBE and BTEX compounds. Low concentrations and cooccurrence of MTBE and BTEX indicate most gasoline contaminants in drinking water probably represent nonpoint sources. Solvents were frequently detected in drinking water in the 12-State area. One or more of 27 individual solvent VOCs were detected at any reporting level in 3,080 drinking-water samples from 304 randomly selected CWSs (14 percent) and in 206 CWSs (9.8 percent) at concentrations at or above 1.0 ?g/L. High co-occurrence among solvents probably reflects common sources and the presence of transformation by-products. Other VOCs were relatively rarely detected in drinking water in the 12-State area. Six percent (127) of the 2,110 randomly selected CWSs reported concentrations of 16 VOCs at or above drinking-water criteria. The 127 CWSs collectively serve 2.6 million people. The occurrence of VOCs in drinking water was significantly associated (p<0.0001) with high population- density urban areas. New Jersey, Massachusetts, and Rhode Island, States with substantial urbanization and high population density, had the highest frequency of VOC detections among the 12 States. More than two-thirds of the randomly selected CWSs in New Jersey reported detecting VOC concentrations in drinking water at or above 1

Water-Resources Investigations Report↗

Investigation of Ground-Water Availability and Quality in Orange County, North Carolina

A countywide inventory was conducted of 649 wells in nine hydrogeologic units in Orange County, North Carolina. As a result of this inventory, estimates of ground-water availability and use were calculated, and water-quality results were obtained from 51 wells sampled throughout the County from December 1998 through January 1999. The typical well in Orange County has an average depth of 208 feet, an average casing length of 53.6 feet, a static water level of 26.6 feet, a yield of 17.6 gallons per minute, and a well casing diameter of 6.25 inches. The saturated thickness of the regolith averages 27.0 feet and the yield per foot of total well depth averages 0.119 gallon per minute per foot. Two areas of the County are more favorable for high-yield wells—a west-southwest to east-northeast trending area in the northwestern part of the County, and a southwest to northeast trending area in the southwestern part of the County. Well yields in Orange County show little correlation with topographic or hydrogeologic setting. Fifty-one sampling locations were selected based on (a) countywide areal distribution, (b) weighted distribution among hydrogeologic units, and (c) permission from homeowners. The list of analytes for the sampling program consisted of common anions and cations, metals and trace elements, nutrients, organic compounds, and radon. Samples were screened for the presence of fuel compounds and pesticides by using immuno-assay techniques. Dissolved oxygen, pH, temperature, specific conductance, and alkalinity were measured in the field. The median pH was 6.9, which is nearly neutral, and the median hardness was 75 milligrams per liter calcium carbonate. The median dissolved solids concentration was 125 milligrams per liter, and the median specific conductance was 175 microsiemens per centimeter at 25 degrees Celsius. Orange County ground water is classified as a calcium-bicarbonate type. High nutrient concentrations were not found in samples collected for this study. Nitrate was detected in 82 percent of the samples at concentrations ranging up to 7.2 milligrams per liter, although the median concentration was 0.49 milligram per liter; all other samples had a concentration of 2.9 milligrams per liter or less. In general, trace elements were detected infrequently or at concentrations less than State drinking-water standards. However, exceedances of North Carolina drinking-water standards were observed for iron (3 exceedances of 51 analyses, detection up to 1,100 micrograms per liter), manganese (12 exceedances of 51 analyses, detection up to 890 micrograms per liter), and zinc (4 exceedances of 31 analyses, detection up to 4,900 micrograms per liter). Lead was detected in 8 of 31 samples with a concentration up to 3.5 micrograms per liter. Zinc, manganese, iron, and copper were the most frequently detected trace metals at 100, 94, 80, and 61 percent, respectively. Lead, arsenic, bromide, alum inum, and selenium were detected in 13 to 26 percent of the analyses. No benzene, toluene, ethylbenzene, and xylene (BTEX) or atrazine compounds were detected in any of the samples. Radon activities in ground water can be high because of the rock units present in Orange County. Radon activity ranged from 38 to 4,462 picocuries per liter countywide, with a median activity of 405 picocuries per liter. Median radon activities in Orange County were highest in felsic rocks (487 picocuries per liter) and lowest in mafic rocks (357 picocuries per liter). When evaluated by individual hydrogeologic units, the median radon activity was highest in the phyllite unit (1,080 picocuries per liter in 2 samples) and the felsic metaigneous unit (571 picocuries per liter in 13 samples). Overall, water-quality data in Orange County indicate few drinking-water concerns. No organic contaminants analyzed (total BTEX and atrazine) or excessive nutrient concentrations were detected, and few exceedances of North Carolina drinking- water standards were detected.

North Carolina↗

Shallow ground-water quality in the Boston, Massachusetts metropolitan area

Analyses of water samples collected from 29 wells across the Boston metropolitan area indicate that shallow ground water in recently urbanized settings often contains trace amounts of nutrients, fuel, and industrial-based organic compounds. Most of the samples that contained detectable amounts of organic compounds also had elevated levels of iron and total dissolved solids. Nitrate was detected in 83 percent of the samples, but the U.S. Environmental Protection Agency's (USEPA) drinking-water standard of 10 milligrams per liter nitrate was exceeded in just one sample. Low levels of volatile organic compounds (VOCs) were detected in 76 percent of the samples, with as many as 13 different VOCs detected in a single sample. The concentration of methyl-tert-butyl ether (MTBE) in one sample was 267 micrograms per liter, which exceeds the Massachusetts Department of Environmental Protection drinking-water guideline of 70 micrograms per liter. Chloroform and MTBE were the two most frequently detected VOCs. MTBE was detected at the same frequency in ground water in the Boston metropolitan area as in other urban areas of New England. Chloroform is detected at higher frequency in old, densely populated areas in New England than in more recently developed, less densely populated areas. Pesticide detections were few, but only at trace concentrations, and none of the concentrations exceeded any drinking-water standard.

Massachusetts↗

Assessment of natural attenuation of ground-water contamination at sites FT03, LF13, and WP14/LF15, Dover Air Force Base, Delaware

Water-quality, aquifer-sediment, and hydrologic data were used to assess the effectiveness of natural attenuation of ground-water contamination at Fire Training Area Three, the Rubble Area Landfill, the Liquid Waste Disposal Landfill, and the Receiver Station Landfill in the East Management Unit of Dover Air Force Base, Delaware. These sites, which are contaminated with chlorinated solvents and fuel hydrocarbons, are undergoing long-term monitoring to determine if natural attenuation continues to sufficiently reduce contaminant concentrations to meet regulatory requirements. This report is the first assessment of the effectiveness of natural attenuation at these sites since long-term monitoring began in 1999, and follows a preliminary investigation done in 1995-96. This assessment was done by the U.S. Geological Survey in cooperation with the U.S. Air Force. Since 1995-96, additional information has been collected and used in the current assessment. The conclusions in this report are based primarily on ground-water samples collected from January through March 2000. Previous analytical results from selected wells, available geologic and geophysical well logs, and newly acquired information such as sediment organic-carbon measurements, hydraulic-conductivity measurements determined from slug tests on wells in the natural attenuation study area, and water-level measurements from surficial-aquifer wells also were used in this assessment. This information was used to: (1) calculate retardation factors and estimate contaminant migration velocities, (2) improve estimates of ground-water flow directions and inferred contaminant migration pathways, (3) better define the areal extent of contamination and the proximity of contaminants to discharge areas and the Base boundary, (4) develop a better understanding of the vertical variability of contaminant concentrations and redox conditions, (5) evaluate the effects of temporal changes on concentrations in the plumes and source areas, and (6) determine whether intrinsic biodegradation is occurring at these sites. The water-quality data indicate that intrinsic biodegradation is occurring at all three sites. The strongest indication of intrinsic biodegradation is the detection of tetrachloroethene and trichloroethene breakdown products within and down-gradient of the source areas. The patterns of electron acceptors and metabolic by-products indicate that contaminant biodegradation has changed the prevailing geochemistry of the surficial aquifer, creating the strongly reducing conditions necessary for chlorinated solvent biodegradation. Geochemical changes include depleted dissolved oxygen and elevated ferrous iron and methane levels relative to concentrations in uncontaminated zones of the surficial aquifer. At Fire Training Area Three and the Rubble Area Landfill sites, natural attenuation appears to be adequate for controlling the migration of the contaminant plumes. At the third site, the Liquid Waste Disposal and Receiver Station Landfills, the plume is larger and the uncertainty about the effectiveness of natural attenuation in reducing contaminant concentrations and controlling plume migration is greater. Ground-water data indicate, however, that U.S. Environmental Protection Agency maximum contaminant levels were not exceeded in any point-of-compliance wells located along the Base boundary. The information presented in this report led to the development of improved conceptual models for these sites, and to the recognition of four issues that are currently unclear and may need further study. These issues include delineating the areal and vertical extent of the contaminant plumes in greater detail, determining the extent of intrinsic biodegradation downgradient of the Liquid Waste Disposal and Receiver Station Landfills, determining the fate of contaminants in the ground-water discharge areas, and determining the effect of temporal variability in source concentrations and ground-water flow patterns on the plume migrating from the Liquid Waste Disposal and Receiver Station Landfills. Some of these issues have been addressed with additional data collection since the January-March 2000 sampling round.

Delaware↗

Occurrence and status of volatile organic compounds in ground water from rural, untreated, self-supplied domestic wells in the United States, 1986-99

Samples of untreated ground water from 1,926 rural, self-supplied domestic wells were analyzed for volatile organic compounds (VOCs) during 1986-99. This information was used to characterize the occurrence and status of VOCs in domestic well water. The samples were either collected as part of the U.S. Geological Survey?s National Water-Quality Assessment (NAWQA) Program occurrence-assessment studies or were compiled by NAWQA from existing ambient ground-water or source-water-quality monitoring programs conducted by local, State, and other Federal agencies. Water samples were collected at the wellhead prior to treatment or storage. In most samples, 55 target VOCs were analyzed, and occurrence and status information generally was computed at an assessment level of 0.2 mg/L (microgram per liter). At least one VOC was detected in 12 percent of samples (232 samples) at an assessment level of 0.2 mg/L. This detection frequency is relatively low compared to the 26 percent detection frequency of at least one VOC in public sup-ply wells sampled by NAWQA, and the difference may be due, in part, to the higher pumping rates, pumping stress factors, and larger contributing areas of public supply wells. Samples with detections of at least one VOC were collected from wells located in 31 of 39 States. Solvents were the most frequently detected VOC group with detections in 4.6 percent of samples (89 samples) at an assessment level of 0.2 mg/L. The geographic distribution of detections of some VOC groups, such as fumigants and oxygenates, relates to the use pattern of com-pounds in that group. With the exception of com-pounds used in organic synthesis, detection frequencies of VOCs by group are proportional to the average half-life of compounds in the group. When the organic synthesis group is excluded from the analysis, a good correlation exists between the detection frequency of VOCs by group and average half-life of compounds in the group. Individually, VOCs were not commonly detected at an assessment level of 0.2 mg/L, with the seven most frequently detected VOCs found in only 1 to 5 percent of samples. Mixtures (two or more compounds) were a common mode of occurrence for VOCs when no assessment level was applied, and mixtures occurred in one-half of all samples that contained at least one VOC. Only 1.4 percent of samples (27 samples) had one or more VOC concentrations that exceeded a federally established drinking-water standard or health criterion. Only 0.1 percent of samples (2 samples) had one or more VOC concentrations that exceeded a taste/odor threshold. Potential point sources of VOCs near domestic wells are numerous. Leaks from under-ground storage tanks and aboveground storage tanks that hold gasoline, diesel fuel, or heating oil have the potential to be major point sources of contaminants to domestic wells. Shock chlorination may be a source of trichloromethane and other trihalomethanes in some domestic wells. Septic systems are believed to be an important source of contaminants to domestic wells, but extensive research on this subject does not exist. VOCs frequently are ingredients in household products such as cleansers and insecticides, and some VOCs have been found in septic systems.

Water-Resources Investigations Report↗

Magnitude and extent of arsenic and thallium concentrations in ground water and sediments at the Charleston Naval Complex, North Charleston, South Carolina, 1994-99

Water-quality samples were collected quarterly during 1994-99 from 604 wells screened in the surficial aquifer system beneath the Charleston Naval Complex, North Charleston, South Carolina. Arsenic and thallium were selected for analysis because concentrations of these metals in some wells consistently exceeded the established (2001) drinking water maximum contaminant levels of 10 and 2 micrograms per liter, respectively. The analysis was conducted to determine the magnitude and spatial distribution of arsenic and thallium in ground water at the Charleston Naval Complex and to quantify arsenic and thallium concentrations in a dated sediment core from Shipyard Creek marsh near the southern boundary of the Naval Complex. The surficial aquifer system beneath the Charleston Naval Complex consists of an unconfined upper surficial aquifer and a confined lower surficial aquifer. Hydraulic connection between the two aquifers is limited or nonexistent throughout the system at the Naval Complex. The Charleston Naval Complex is divided into nine operational units designated as zones A through I. Arsenic and thallium concentration data were compiled and interpreted for the two surficial aquifers within each zone. Mean arsenic (n=603) and thallium (n=604) concentrations were calculated for water samples from each well screened in the upper and lower surficial aquifers. In the upper surficial aquifer, mean arsenic concentrations ranged from 0.9 to 339 micrograms per liter and exceeded 10 micrograms per liter in 29 percent of the wells. In the lower surficial aquifer, mean arsenic concentrations ranged from 1.0 to 97.4 micrograms per liter and exceeded 10 micrograms per liter in 23 percent of the wells. The greatest number of water samples with mean arsenic concentrations exceeding 10 micrograms per liter were collected from wells in the upper surficial aquifer at zone E in the northwestern part of the study area. Well clusters, defined as three or more wells in a solid-waste management unit or area of concern, where the mean arsenic concentration exceeded 10 micrograms per liter, were identified in association with 12 sites in the upper surficial aquifer-solid-waste management unit 039 (a drum-storage area) in zone A; solid-waste management units 044 (coal-storage area) and 047 (burning dump) in zone C; solid-waste management unit 065 (lead-storage area) and area of concern 556 (dry docks 3 and 4) in zone E; areas of concern 609 (building 1346 gas station) and 613 (locomotive shop) in zone F; solid-waste management units 006 (public works storage yard) and 008 (oil sludge pit), and area of concern 709 (fuel-delivery system wells 12, 13, and 14) in zone G; and solid-waste management units 009 (closed landfill) and 196 (south landfill) in zone H. One well cluster was identified in the lower surficial aquifer in association with solidwaste management unit 009 (closed landfill) in zone H. Mean thallium concentrations in water from all wells ranged from less than 1.6 to 32.6 micrograms per liter in water samples from the upper surficial aquifer, and from less than 1.6 to 67.7 micrograms per liter in water samples from the lower surficial aquifer. Mean thallium concentrations equal to or greater than 10 micrograms per liter were present in water samples from 21 of 604 wells (3.5 percent). Of the 21 wells, 14 wells were located at solid-waste management unit 009 (closed landfill) in zone H near Shipyard Creek, 8 wells in the upper aquifer, and 6 wells in the lower aquifer. One well cluster where thallium exceeded 10 micrograms per liter was identified in association with solid-waste management unit 009 (closed landfill) in the upper surficial aquifer. Mean arsenic and thallium concentrations in water were calculated for all wells screened in one aquifer and located in a single zone, and are referred to as zone mean concentration in this report. Zone mean arsenic concentrations in all nine zones ranged from 3.2 to 18 micrograms per liter in water samples from the upper surficial aquifer and from 2.7 to 22 micrograms per liter in water samples from the lower surficial aquifer. Zone mean thallium concentrations in all nine zones ranged from 3.2 to 13 micrograms per liter in water samples from the upper surficial aquifer and from 3.2 to 14 micrograms per liter in water samples from the lower surficial aquifer. Ground-water samples rarely had elevated (equal to or greater than 10 micrograms per liter) concentrations of both arsenic and thallium. Water samples had coincident elevated arsenic and thallium concentrations in 10 wells in zone H, 1 well in zone A, and 1 well in zone B. Sediment quality at Shipyard Creek marsh was investigated by collecting an 11.8-foot -long sediment core (SYC-1) adjacent to zone I. The mean arsenic concentration in sediment samples from SYC-1 (n= 160) was 3.05 milligrams per kilogram plus or minus 0.92. The mean arsenic concentration and standard deviation calculated for SYC-1 sediment samples fall within the standard error for the background mean arsenic concentration reported for South Carolina sediments (1.5 milligrams per kilogram plus or minus 2. 7). All but one sample (core depth =50 inches) was less than the threshold-effects level of 7.24 milligrams per kilogram. Acid extracts of the sediment samples were analyzed for thallium concentration, but none were detected. These data indicate no obvious change in arsenic or thallium concentrations with depth in the core.

South Carolina↗

Water and bed-sediment quality in the vicinity of Berlin Lake, Ohio, 2001

Berlin Lake, in northeast Ohio, was created by the U.S. Army Corps of Engineers in 1943 and is used primarily for flood control for the upper reaches of the Mahoning River. The area surrounding and under the lake has been tapped for oil and natural gas production. One of the by-products of oil and gas production is concentrated salt water or brine, which might have an effect on the chemical quality of area potable-water sources. This report presents the results of a U.S. Geological Survey baseline study to collect current (2001) water and sediment-quality data and to characterize water quality in the Berlin Lake watershed. Chloride-to-bromide ratios were used to detect the presence of brine in water samples and to indicate possible adverse effects on water quality. Analyses of ground-water samples from domestic wells in the area indicate a source of chloride and bromide, but defining the source would require more data collection. Analyses of specific conductance and dissolved solids indicate that 78 percent (14 of 18) of the ground-water samples exceeded the Secondary Maximum Contaminant Level for dissolved solids in public water supplies of 500 milligrams per liter (mg/L), compared to 6 percent of samples exceeding 500 mg/L in two nearby studies. Surface water was analyzed twice, once each during low-flow and surface runoff conditions. A comparison of the 2001 data to historical chloride concentrations, accounting for seasonal changes, does not indicate an increase in chloride loads for surface water in the area of Berlin Lake. Polycyclic aromatic hydrocarbons were found in bed-sediment samples collected from the mouths of major tributaries to Berlin Lake. Polycyclic aromatic hydrocarbons are produced during the incomplete combustion of organic carbon materials such as wood and fossil fuels, and they are components of petroleum products.

Water-Resources Investigations Report↗