USGS Science⌕ Search

SEARCH · USGS Science

Results for “Geothermics”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Heat flow in Railroad Valley, Nevada and implications for geothermal resources in the south-central Great Basin

The Great Basin is a province of high average heat flow (approximately 90 mW m -2 ), with higher values characteristic of some areas and relatively low heat flow (<60 mW m -2 ) characteristic of an area in south-central Nevada known as the Eureka Low. There is hydrologic and thermal evidence that the Eureka Low results from a relatively shallow, hydrologically controlled heat sink associated with interbasin water flow in the Paleozoic carbonate aquifers. Evaluating this hypothesis and investigating the thermal state of the Eureka Low at depth is a high priority for the US Geological Survey as it prepares a new national geothermal resource assessment. Part of this investigation is focused on Railroad Valley, the site of the largest petroleum reservoirs in Nevada and one of the few locations within the Eureka Low with a known geothermal system. Temperature and thermal conductivity data have been acquired from wells in Railroad Valley in order to determine heat flow in the basin. The results reveal a complex interaction of cooling due to shallow ground-water flow, relatively low (49 to 76 mW m -2 ) conductive heat flow at depth in most of the basin, and high (up to 234 mW m -2 ) heat flow associated with the 125°C geothermal system that encompasses the Bacon Flat and Grant Canyon oil fields. The presence of the Railroad Valley geothermal resource within the Eureka Low may be reflect the absence of deep ground-water flow sweeping heat out of the basin. If true, this suggests that other areas in the carbonate aquifer province may contain deep geothermal resources that are masked by ground-water flow.

Nevada↗

Searching for an electrical-grade geothermal resource in Northern Arizona to help geopower the west

The U.S Department of Energy s "Geopowering the West" initiative seeks to double the number of states (currently 4) that generate geothermal electric power over the next few years. Some states, like New Mexico and Oregon, have plentiful and conspicuous geothermal manifestations, and are thus likely to further DOE's goal relatively easily. Other states, including Arizona, demonstrate less geothermal potential, but nevertheless have sites worthy of additional investigation. The Arizona site with greatest potential is near Sunset Crater, a basaltic volcano less than 1,000 years old several kilometers northeast of Flagstaff. Several silicic volcanoes nearby are young enough to have still-hot intrusive roots. Moreover, there is geophysical evidence for magma or hot rock in middle to lower crust beneath the area. A high level of interest in this area by the geothermal industry during the 1970s waned because surface thermal indicators, such as high heat flow, hot springs, and fumaroles are absent. The absence of these features is probably the result of a well-documented deep and pervasive regional aquifer, which likely creates a thermal barrier to the rise of hydrothermal activity from depth, Surface based geological and geophysical studies are under way to evaluate further the geothermal potential of the area and to locate a site for a drill hole to explore for a hydrothermal system beneath the ground-water barrier.

California, Nevada↗

Geothermal resource assessment of the United States

Geothermal resource assessment is the broadly based appraisal of the quantities of heat that might be extracted from the earth and used economically at some reasonable future time. In the United States, the Geological Survey is responsible for preparing geothermal assessments based on the best available data and interpretations. Updates are required every few years owing to increasing knowledge, enlarging data base, improving technology, and changing economics. Because geothermal understanding is incomplete and rapidly evolving, the USGS complements its assessments with a broad program of geothermal research that includes (1) study of geothermal processes on crustal and local scales, (2) regional evaluations, (3) intensive study of type systems before and during exploitation (4) improvement of exploration techniques, and (5) investigation of geoenvironmental constraints. ?? 1978 Birkha??user Verlag.

Pure and Applied Geophysics PAGEOPH↗

Detection of aseismic slip and poroelastic reservoir deformation at the North Brawley Geothermal Field from 2009 to 2019

The North Brawley Geothermal Field, located within the Brawley Seismic Zone of Southern California, presents a case study for understanding seismic hazards linked to fluid injection and geothermal energy extraction. An earthquake swarm near the geothermal field in 2012 included two earthquakes with magnitudes greater than 5 and was potentially preceded by a years-long aseismic slip transient. To better understand ground deformation around the geothermal field, including its evolution with time and its physical mechanisms, we analyze deformation before, during, and after the swarm using ground- and satellite-based geodetic techniques between 2009 and 2019. We integrate observations from GNSS, Sentinel-1, TerraSAR-X, UAVSAR, and leveling surveys into a single deformation history. Modeling of this new collection of observations at the North Brawley Geothermal Field provides evidence for 80% more pre-swarm aseismic slip than previously recognized from 2009 to 2012. During the 2012 Brawley swarm, our geodetic slip inversions closely match the results of seismic waveform inversions from the swarm events. After the 2012 swarm, surface deformation is dominated by poroelastic deformation of a shallow fluid reservoir at <1 km depth rather than fault slip. The deformation history and seismicity catalogs at North Brawley suggest a cessation of fault-related slip during the ∼7 years after the 2012 earthquake swarm.

California↗

Three-dimensional geologic model of the northern Nevada rift and the Beowawe geothermal system, north-central Nevada

A three-dimensional (3D) geologic model of part of the northern Nevada rift encompassing the Beowawe geothermal system was developed from a series of two-dimensional (2D) geologic and geophysical models. The 3D model was constrained by local geophysical, geologic, and drill-hole information and integrates geologic and tectonic interpretations for the region. It places important geologic constraints on the extent and configuration of the active Beowawe geothermal system. The geologic framework represented in this model facilitates hydrologic modeling of the Beowawe geothermal system and evaluation of fluid flow in faults and adjacent rock units. Basin depths were determined using an iterative gravity-inversion technique that calculates the thickness of low-density, basin-filling deposits. The remaining subsurface structure was modeled using 2D potential-field modeling software. Crustal cross sections from the 2D models were generalized for use in the 3D model and consist of six stratigraphic layers defined as low-density basin sediments, volcanic rocks, basalt-andesite rocks of the northern Nevada rift, Jurassic and Cretaceous intrusive rocks, and Paleozoic siliceous and carbonate sedimentary rocks of the upper and lower plates of the Roberts Mountains allochthon, respectively. This simplified stratigraphy was combined with mapped surface geology and was extrapolated across the 3D model area. Features along the northern Nevada rift depicted by the model may represent preexisting crustal structures that controlled the locations and character of Tertiary tectonic and magmatic events related to Basin and Range extension and emplacement of the middle Miocene northern Nevada rift. Several of the geologic features represented are important components of the Beowawe geothermal system. Prominent ENE-trending faults (e.g., Malpais fault) that bound the southern edge of Whirlwind Valley, and older NNW-striking faults (e.g., Dunphy Pass and Muleshoe faults) that form major features of the model, are likely important pathways for geothermal fluids and groundwater flow from the Humboldt River, which may recharge the Beowawe system.

Nevada↗

Introduction to this special section: Geothermal energy

Geothermal energy is a global renewable resource that has the potential to provide a significant portion of baseload energy in many regions. In the United States, it has the potential to provide 8.5% of the electric generation capacity by the middle of the century. In general, geothermal systems require heat, permeability, and water to be viable for energy generation. However, with current technologies, only heat is strictly necessary in a native system. Engineered geothermal systems (EGS) introduce water into the subsurface at elevated pressures and reduced temperatures and enhance permeability through hydraulic and/or shear fracturing. Additionally, although moderate- to high-temperature resources currently dominate geothermal energy production, low-temperature resources have been utilized for direct-use cases. When well balanced and maintained, geothermal resources can produce significant amounts of heat and achieve long-term sustainability on the order of an estimated tens to hundreds of years.

The Leading Edge↗

Context-specific parasitism in Tubifex tubifex in geothermally influenced stream reaches in Yellowstone National Park

Parasites can regulate host abundance and influence the composition and structure of communities. However, host-parasite interactions might be context-specific if environmental conditions can alter the outcome of parasitism and disease. An understanding of how host-parasite interactions might change in different contexts will be useful for predicting and managing disease against a background of anthropogenic environmental change. We examined the ecology of Myxobolus cerebralis , the parasite that causes whirling disease in salmonids, and its obligate host, Tubifex tubifex , in geothermally variable stream reaches in Yellowstone National Park. We identified reaches in 4 categories of geothermal influence, which were characterized by variable substrates, temperatures, specific conductivities, and pH. In each reach, we measured aspects of host ecology (abundance, relative abundance, size, and genotype of T. tubifex ), parasite ecology (infection prevalence in T. tubifex and abundance of M. cerebralis -infected T. tubifex ), and risk to fish of contracting whirling disease. Tubifex tubifex abundance was high all in reaches characterized by geothermal influence, whereas abundance of M. cerebralis -infected T. tubifex was high only in reaches characterized by intermediate geothermal influence. We suggest that habitat had a contextual effect on parasitism in the oligochaete host. Abundance of infected hosts appeared to depend on host abundance in all reach types except those with high geothermal influence, where abundance of infected hosts depended on environmental factors.

Journal of the North American Benthological Societ↗

The evolution of volcano-hosted geothermal systems based on deep wells from Karaha-Telaga Bodas, Indonesia

Temperature and pressure surveys, fluid samples, and petrologic analyses of rock samples from deep drill holes at the Karaha - Telaga Bodas geothermal field on the volcanic ridge extending northward from Galunggung Volcano, West Java, have provided a unique opportunity to characterize the evolution of an active volcano-hosted geothermal system. Wells up to 3 km in depth have encountered temperatures as high as 353??C and a weakly altered granodiorite that intruded to within 2 to 3 km of the surface. The intrusion is shallowest beneath the southern end of the field where an acid lake overlies a nearly vertical low resistivity structure (<10 ohm-m) defined by magnetotelluric measurements. This structure is interpreted to represent a vapor-dominated chimney that provides a pathway to the surface for magmatic gases. Four distinct hydrothermal mineral assemblages document the evolution of the geothermal system and the transition from liquid- to vapor-dominated conditions. The earliest assemblage represents the initial liquid-dominated system generated during emplacement of the granodiorite between 5910 ?? 76 and 4200 ?? 150 y BP. Tourmaline, biotite, actinolite, epidote and clay minerals were deposited contemporaneously at progressively greater distances from the intrusive contact (assemblage 1). At 4200 ?? 150 y BP, flank collapse and the formation of the volcano's crater, Kawah Galunggung, resulted in catastrophic decompression and boiling of the hydrothermal fluids. This event initiated development of the modern vapor-dominated regime. Chalcedony and then quartz were deposited as the early low salinity liquids boiled (assemblage 2). Both vapor- and liquid-rich fluid inclusions were trapped in the quartz crystals. Liquid-rich fluid inclusions from the southern part of the field record salinities ranging from 0 to 26 weight percent NaCl- CaCl2 equivalent and locally contain fluorite daughter crystals. We suggest, based on temperature-salinity relationships and evidence of boiling, that these fluids were progressively concentrated as steam was lost from the system. However, mixing with fluids derived from the underlying intrusion or generated during the formation of acid SO4 water on the vapor-dominated chimney margins could have contributed to the observed salinities. As pressures declined, CO2- and SO4-rich steam-heated water drained downward, depositing anhydrite and calcite (assemblage 3) in the fractures, limiting further recharge. Fluid inclusions with salinities up to 31 weight percent NaCl equivalent were trapped in these minerals as the descending water vaporized. The final assemblage is represented by precipitates of NaCl, KCl and FeClx deposited on rock surfaces in portions of the vapor-dominated zone that boiled dry. Vapor-dominated conditions extend over a distance of at least 10 km and to depths below sea level. Deep wells drilled into the underlying liquid-dominated reservoir in the northern and central part of the volcanic ridge produce low salinity fluids representing recent recharge of meteoric and steam-heated water. The evolution of volcanic-hosted vapor-dominated geothermal systems can be described by a five stage model. Stage 1 involves the formation of an over-pressured liquid-dominated geothermal system soon after magmatic intrusion. In Stages 2 and 3, pressures progressively decrease, and a curtain of steam-heated water surrounding a magmatic vapor-dominated chimney at 350??C and 14 ?? 2 MPa develops. The relatively low pressure near the base of the chimney causes liquid inflow adjacent to the intrusion and the development of a secondary marginal vapor-dominated zone. In Stage 4, the magmatic vapor discharge from the intrusion becomes small, vapor pressure declines, and the secondary vapor-dominated zone expands above the intrusion. In Stage 5, the vapor-dominated zone floods because heat from the intrusion is insufficient to boil all liquid inflow. A more common, liquid-dominated volcanic-hosted system the

American Journal of Science↗

Numerical analysis of seawater circulation in carbonate platforms: II. The dynamic interaction between geothermal and brine reflux circulation

Density-driven seawater circulation may occur in carbonate platforms due to geothermal heating and / or reflux of water of elevated salinity. In geothermal circulation lateral contrasts in temperature between seawater and platform groundwaters warmed by the geothermal heat flux result in upward convective flow, with colder seawater drawn into the platform at depth. With reflux circulation, platform-top waters concentrated by evaporation flow downward, displacing less dense underlying groundwaters. We have used a variable density groundwater flow model to examine the pattern, magnitude and interaction of these two different circulation mechanisms, for mesosaline platform-top waters ( 50 ‰ ) and brines concentrated up to saturation with respect to gypsum ( 150 ‰ ) and halite ( 246 ‰ ). Geothermal circulation, most active around the platform margin, becomes restricted and eventually shut-off by reflux of brines from the platform interior towards the margin. The persistence of geothermal circulation is dependent on the rate of brine reflux, which is proportional to the concentration of platform-top brines and also critically dependent on the magnitude and distribution of permeability. Low permeability evaporites can severely restrict reflux whereas high permeability units in hydraulic continuity enhance brine transport. Reduction in permeability with depth and anisotropy of permeability (kv < < kh) focuses flow laterally in the shallow subsurface (<1 km), resulting in a horizontally elongated brine plume. Aquifer porosity and dispersivity are relatively minor controls on reflux. Platform brines can entrain surficial seawater when brine generating conditions cease but the platform-top remains submerged, a variant of reflux we term "latent reflux". Brines concentrated up to gypsum saturation have relatively long residence times of at least 100 times the duration of the reflux event. They thus represent a long-term control on post-reflux groundwater circulation, and consequently on the rates and spatial patterns of shallow burial diagenesis, such as dolomitization.

American Journal of Science↗

Assessment of Moderate- and High-Temperature Geothermal Resources of the United States

Scientists with the U.S. Geological Survey (USGS) recently completed an assessment of our Nation's geothermal resources. Geothermal power plants are currently operating in six states: Alaska, California, Hawaii, Idaho, Nevada, and Utah. The assessment indicates that the electric power generation potential from identified geothermal systems is 9,057 Megawatts-electric (MWe), distributed over 13 states. The mean estimated power production potential from undiscovered geothermal resources is 30,033 MWe. Additionally, another estimated 517,800 MWe could be generated through implementation of technology for creating geothermal reservoirs in regions characterized by high temperature, but low permeability, rock formations.

Fact Sheet↗

Abrupt physical and chemical changes during 1992-1999, Anderson Springs, SE Geyser Geothermal Field, California

The Anderson Springs area is located about 90 miles (145 kilometers) north of San Francisco, California, in the southwestern part of Lake County. The area was first developed in the late 1800s as a health resort, which was active until the 1930s. Patrons drank a variety of cool to hot mineral waters from improved springs, swam in various baths and pools, and hiked in the rugged hills flanking Anderson Creek and its tributaries. In the bluffs to the south of the resort were four small mercury mines of the eastern Mayacmas quicksilver district. About 1,260 flasks of mercury were produced from these mines between 1909 and 1943. By the early 1970s, the higher ridges south and west of Anderson Springs became part of the southeast sector of the greater Geysers geothermal field. Today, several electric power plants are built on these ridges, producing energy from a vapor-dominated 240 °C reservoir. Only the main hot spring at Anderson Springs has maintained a recognizable identity since the 1930s. The hot spring is actually a cluster of seeps and springs that issue from a small fault in a ravine southwest of Anderson Creek. Published and unpublished records show that the maximum temperature (Tm) of this cluster fell gradually from 63°C in 1889 to 48°C in 1992. However, Tm of the cluster climbed to 77°C in 1995 and neared boiling (98°C) in 1998. A new cluster of boiling vents and small fumaroles (Tm = 99.3°C) formed in 1998 about 30 m north of the old spring cluster. Several evergreen trees on steep slopes immediately above these vents apparently were killed by the new activity. Thermal waters at Anderson Hot Springs are mostly composed of near-surface ground waters with some added gases and condensed steam from The Geysers geothermal system. Compared to gas samples from Southeast Geysers wells, the hot spring gases are higher in CO 2 and lower in H 2 S and NH 3 . As the springs increased in temperature, however, the gas composition became more like the mean composition of steam discharges from the Southeast Geysers. The hot spring waters are low in ions of Cl, B, and Li, but relatively high in HCO 3 , SO 4 and NH 4 . The stable-isotope compositions (deuterium and oxygen-18) of these waters plot near the global meteoric water line. Geochemical data through time reveal apparent maxima in the concentrations of SO 4 , Fe, and Mn in 1991 to 1992, before the cluster became hotter. The black-to-gray deposits from the new spring cluster are rich in pyrite and contain anomalous metals. About one-half mile to the east of the hot springs, mineralized water discharges intermittently from an old adit of the Schwartz (Anderson) mine, and enters a tributary of Anderson Creek. This drainage increased substantially in July 1998, and a slurry of mine water and precipitates were transported down the tributary and into Anderson Creek. In December 1998, the adit water was 22°C, and had a chemical composition that was similar to spring waters that once discharged in the ravines surrounding the old Anderson Springs resort. The cause for the abrupt changes that have occurred in thermal features at Anderson Springs is still not resolved. One possibility is that these changes are a response to withdrawal of steam from The Geysers geothermal field over more than 20 years of production. Pressure declines in the geothermal reservoir may have caused a "drying out" of the overlying condensation zone. Induced boiling in this zone and upflow of deep steam to shallower depths would cause heating and vaporization of shallow ground waters. In addition, earthquakes occurring in the vicinity of Anderson Springs have increased significantly after nearby geothermal power plants began operation. These earthquakes may have enhanced surface discharge of thermal fluids along fractures and faults.

California↗

Hydrogeologic framework and considerations for drilling and grouting of closed-loop geothermal bores in the Erie-Ontario Lowlands and Allegheny Plateau of New York State

The hydrogeologic framework at closed-loop geothermal sites in the Erie-Ontario Lowlands and Allegheny Plateau of central and western New York is the result of the complex interaction of bedrock geology, glacial geology, and groundwater hydrology, and the occurrence of petroleum and gas. Considerations for closed-loop geothermal bore installation include the thickness and character of glacial deposits, bedrock solubility and depth to competent rock, karst development, the distribution of highly permeable zones and their hydraulic heads, and the presence of saline water, gas, and oil. The hydrogeology of the Erie-Ontario Lowlands and Allegheny Plateau poses challenges to closed-loop geothermal bore drilling and casing; managing drill cuttings, discharge water, and gas; and grouting. The potential to encounter severe challenges typically increases with bore depth. This report highlights hydrogeologic considerations for closed-loop geothermal bore installation in New York’s Erie-Ontario Lowlands and Allegheny Plateau to help guide the efficient and safe development of geothermal resources in the regions.

New York↗

Regional and local networks of horizontal control, Cerro Prieto geothermal area, Mexico

The Cerro Prieto geothermal area in the Mexicali Valley 30 km southeast of Mexicali, Baja California, is probably deforming due to (1) the extraction of large volumes of steam and hot water, and (2) active tectonism. Two networks of precise horizontal control were established in Mexicali Valley by the U.S. Geological Survey in 1977-78 to measure both types of movement as they occur. These networks consisted of (1) a regional trilateration net brought into the mountain ranges west of the geothermal area from survey stations on an existing U.S. Geological Survey crustal-strain network north of the international border, and (2) a local net tied to stations in the regional net and encompassing the area of present and planned geothermal production. Survey lines in this net were selected to span areas of probable ground-surface movements in and around the geothermal area. Electronic distance measuring (EDM) instruments, operating with a modulated laser beam, were used to measure the distances between stations in both networks. The regional net was run using a highly precise long-range EDM instrument, helicopters for transportation of men and equipment to inaccessible stations on mountain peaks, and a fixed wing airplane flying along the line of sight. Precision of measurements with this complex long-range system approached 0.2 parts per million of line length. The local net was measured with medium range EDM instrument requiring minimal ancillary equipment. Precision of measurements with this less complex system approached 3 parts per million for the shorter line lengths. The detection and analysis of ground-surface movements resulting from tectonic strains or induced by geothermal fluid withdrawal is dependent on subsequent resurveys of these networks.

Baja California↗

Selected data for low-temperature (less than 90 degrees C) geothermal systems in the United States; reference data for U.S. Geological Survey Circular 892

Supporting data are presented for the 1982 low-temperature geothermal resource assessment of the United States. Data are presented for 2072 geothermal sites which are representative of 1168 low-temperature geothermal systems identified in 26 States. The low-temperature geothermal systems consist of 978 isolated hydrothermal-convection systems, 148 delineated-area hydrothermal-convection systems, and 42 delineated-area conduction-dominated systems. The basic data and estimates of reservoir conditions are presented for each geothermal system, and energy estimates are given for the accessible resource base, resource, and beneficial heat for each isolated system.

Open-File Report↗

Some fluid-inclusion measurements for geothermal drill holes in California, Nevada, El Salvador, and Russia

The purpose of this report is to make available fluid-inclusion information from drill holes in five geothermal areas: The Geysers and Long Valley caldera in northern California; Steamboat Springs, Nevada; the Ahuachapan field of El Salvador, Central America; and the Mutnovsky geothermal field, Kamchatka Peninsula, Russia. These data were produced at the request of various individuals to provide needed subsurface-temperature data for their investigations. The fluid-inclusion information presented in this report has not been previously published, and, since the author did not work in these geothermal areas, only a very minimal attempt is made at interpreting the data. Information on the location of the drill holes from which the core specimens originated ranges from very poor in the case of the Russian drill holes to very good for those in the USA. Mineral specimens from drill-core samples in the five geothermal areas were utilized as cleavage chips, thin sections polished on a single side, or double polished thin sections (polished on both sides). Fluid inclusions from all three USA geothermal areas were found in either hydrothermal or primary quartz crystals. These fluid inclusions firstly were frozen and gradually thawed to determine the final melting-point temperatures (Tm) as the last piece of ice melted and secondly, were heated to the temperature at which the vapor phase disappeared to obtain homogenization temperatures (Tn). For the El Salvador and Russian core specimens the fluid inclusions were hosted in calcite, and the order of the two procedures was reversed because calcite is a much softer mineral than quartz and there is a greater danger of the fluid inclusions decrepitating as the ice expands during freezing. A Chaixmeca microthermometry apparatus was used during studies of the Steamboat Springs and The Geysers fluid inclusions. For the remaining studies, a Linkam THM 600 heating/freezing stage and TMS 90 temperature control system were employed. Accuracy of the data generated from both instruments is similar, with values of about ±2°C for heating studies and about ±0.2°C for the freezing methods.

Open-File Report↗

Subsurface temperatures and geothermal gradients on the North Slope, Alaska

Geothermal gradients as interpreted from a series of high-resolution stabilized well-bore-temperature surveys from 46 North Slope, Alaska, wells vary laterally and vertically throughout the near-surface sediment (0-2,000 m). The data from these surveys have been used in conjunction with depths of ice-bearing permafrost, as interpreted from 102 well logs, to project geothermal gradients within and below the ice-bearing permafrost sequence. The geothermal gradients calculated from the projected temperature profiles are similar to the geothermal gradients measured in the temperature surveys. Measured and projected geothermal gradients in the ice-bearing permafrost sequence range from 1.5??C/100m in the Prudhoe Bay area to 5.1??C/100m in the National Petroleum Reserve in Alaska (NPRA).

Society of Petroleum Engineers of AIME, (Paper) SP↗

Prioritizing High-Temperature Geothermal Resources in Utah

The Utah Geological Survey and the Utah Energy Office recently released geothermal resource information for Utah as a "digital atlas." We are now expanding this project to include economic analyses of selected geothermal sites and previously unavailable resource information. The enhancements to the digital atlas will include new resource, demographic, regulatory, economic, and other information to allow analyses of economic factors for comparing and ranking geothermal resource sites in Utah for potential electric power development. New resource information includes temperature gradient and fluid chemistry data, which was previously proprietary. Economic analyses are based upon a project evaluation model to assess capital and operating expenses for a variety of geothermal powerplant configuration scenarios. A review of legal and institutional issues regarding geothermal development coupled with water development will also be included.

Conference Paper↗

GIS methodology for geothermal play fairway analysis: Example from the Snake River Plain volcanic province

Play fairway analysis in geothermal exploration derives from a systematic methodology originally developed within the petroleum industry and is based on a geologic and hydrologic framework of identified geothermal systems. We are tailoring this methodology to study the geothermal resource potential of the Snake River Plain and surrounding region. This project has contributed to the success of this approach by cataloging the critical elements controlling exploitable hydrothermal systems, establishing risk matrices that evaluate these elements in terms of both probability of success and level of knowledge, and building automated tools to process results. ArcGIS was used to compile a range of different data types, which we refer to as ‘elements’ (e.g., faults, vents, heatflow…), with distinct characteristics and confidence values. Raw data for each element were transformed into data layers with a common format. Because different data types have different uncertainties, each evidence layer had an accompanying confidence layer, which reflects spatial variations in these uncertainties. Risk maps represent the product of evidence and confidence layers, and are the basic building blocks used to construct Common Risk Segment (CRS) maps for heat, permeability, and seal. CRS maps quantify the variable risk associated with each of these critical components. In a final step, the three CRS maps were combined into a Composite Common Risk Segment (CCRS) map for analysis that reveals favorable areas for geothermal exploration. Python scripts were developed to automate data processing and to enhance the flexibility of the data analysis. Python scripting provided the structure that makes a custom workflow possible. Nearly every tool available in the ArcGIS ArcToolbox can be executed using commands in the Python programming language. This enabled the construction of a group of tools that could automate most of the processing for the project. Currently, our tools are repeatable, scalable, modifiable, and transferrable, allowing us to automate the task of data analysis and the production of CRS and CCRS maps. Our ultimate goal is to produce a toolkit that can be imported into ArcGIS and applied to any geothermal play type, with fully tunable parameters that will allow for the production of multiple versions of the CRS and CCRS maps in order to better test for sensitivity and to validate results.

Idaho↗