USGS Science⌕ Search

SEARCH · USGS Science

Results for “Sensor Review”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

77 records · Page 5Linked to original sources

Pressure calibrants in the hydrothermal diamond-anvil cell

Based on the equation of state of water (EOSW), experimental pressure in the hydrothermal diamond-anvil cell (HDAC) using pure water or dilute aqueous solutions as a pressure medium can be accurately determined at each measured temperature. Consequently, meaningful interpretations can be obtained for observations in the HDAC, which has been widely accepted as a versatile, modern apparatus for hydrothermal experiments. However, this is not true when other pressure media were used because there is no reliable way to determine experimental pressure other than the use of in situ pressure sensors. Most of the available pressure sensors are difficult to apply because they either require expensive facilities to perform the measurements or are unable to provide the accuracy needed for the interpretation of hydrothermal experiments. The only exception is to use the interferometric method to detect the ??-?? quartz transition, although such applications are limited to temperatures above 573??C. In this study, three pressure calibrants were calibrated for applications at lower temperatures, and they were based on visual observation of the ferroelastic phase transitions in BaTiO3 (tetragonal/cubic), Pb3(PO4)2 (monoclinic/trigonal), and PbTiO3 (tetragonal/cubic). For the phase transitions in BaTiO3 and Pb3(PO4)2, the temperature at which twinning disappears during heating was taken as the transition temperature (Ttr); the phase transition pressures (Ptr) can be calculated, respectively, from Ptr (MPa; ??3%) = 0.17 - 21.25 [(Ttr) - 115.3], and Ptr (MPa; ??2%) = 1.00 - 10.62 [(Ttr) - 180.2], where Ttr is in ??C. For the phase transition in PbTiO3, the temperature at which the movement of phase front begins (or ends) on heating (or cooling) was taken as the transition temperature (Ttr,h or Ttr,c), and the phase transition pressures on heating (Ptr,h) and cooling (Ptr,c) can be calculated from Ptr,h (MPa; ??4%) = 7021.7 - 14.235 (Ttr,h), and Ptr,c (MPa; ??4%) = 6831.3 - 14.001 (Ttr,c). Phase transitions for these three pressure calibrants are easy to detect visually, and their P-T phase boundaries have negative slopes and intersect isochors of most of the geologic fluids at high angles and, therefore, are easy to apply. Copyright ?? 2007 by V. H. Winston & Son, Inc. All rights reserved.

International Geology Review↗

Evaluation of landslide monitoring in the Polish Carpathians

In response to the June 15, 2010 request from the Polish Geological Institute (PGI) to the U.S. Geological Survey (USGS) for assistance and advice regarding real-time landslide monitoring, landslide specialists from the USGS Landslide Hazard Program visited PGI headquarters and field sites in September 2010. During our visit we became familiar with characteristics of landslides in the Polish Carpathians, reviewed PGI monitoring techniques, and assessed needs for monitoring at recently activated landslides. Visits to several landslides that are monitored by PGI (the Just, Hańczowa, Szymbark, Siercza and Łasńica landslides) revealed that current data collection (monthly GPS and inclinometer surveys, hourly piezometers readings) is generally sufficient for collecting basic information about landslide displacement, depth, and groundwater conditions. Large landslides are typically hydrologically complex, and we would expect such complexity in Carpathian landslides, given the alternating shale and sandstone stratigraphy and complex geologic structures of the flysch bedrock. Consequently groundwater observations could be improved by installing several piezometers that sample the basal shear zone of each landslide being monitored by PGI. These could be supplemented by additional piezometers at shallower depths to help clarify general flow directions and hydraulic gradients. Remedial works at Hańczowa make the landslide unsuitable for monitoring as part of an early warning network. Monitoring there should focus on continued performance of the remedial works. Our suggestions for new monitoring at recently activated landslides are summarized in table 1. Displacement monitoring using extensometers and (or) GPS is a high priority at Kłodne, Łaśnica, Łazki, and Siedloki. Geomorphologic mapping of active surface features (scarps, cracks, shear zones, folds, and thrusts) in sufficient detail to reveal the kinematics of each landslide would greatly help in planning subsurface exploration and monitoring. Mapping should take advantage of existing and future airborne lidar data sets of specific areas, where available. Borehole inclinometers and piezometers would complete the basic monitoring package for these landslides. The landslide at Kłodne may be well suited for more detailed monitoring for landslide process research, although research opportunities exist at the other landslides as well. The landslide near Siedloki may be a good candidate for terrestrial laser scanning (TLS). Tandem streamflow gages upstream and downstream from the Siedloki landslide, or laser distance meters to monitor advancement of the toe, may be needed to provide warning of stream blockage of Potok Milowski. A real-time warning system specifically for the Łazki landslide might be considered due to potential concerns about catastrophic movement into Międzybrodzie Reservoir. Challenges associated with the establishment of a complete real-time monitoring and early warning system are far greater than just the technical and logistical aspects of installing remote monitoring systems at a large number of landslides. Long-term maintenance of a landslide monitoring network will involve considerable effort and expense as sensors break-down from exposure to weather, landslide movement, and harsh underground environmental conditions. Once PGI’s planned pilot network of 10-20 monitored landslides is operating, a period of observation and analysis will be needed to establish appropriate alert levels and criteria for issuing alerts and warnings. Simultaneously, discussions with authorities will be needed to develop action plans for responding to landslide notifications and (or) warnings. Public resistance to landslide warnings and mandated evacuations may be high given the low historical incidence of fatalities and injuries resulting from Carpathian landslides and the small potential for warnings to reduce landslide damage to homes and land. Careful weighing of purpose, advantages, and costs of a large-scale monitoring and early warning program is needed early in the planning process and should be revisited regularly throughout pilot and final implementation. In this report, we present a generic plan for monitoring of a hypothetical Carpathian landslide that illustrates how our suggestions for each of the specific landslides could be implemented. The plan includes basic pore pressure, displacement, and weather monitoring, along with supplemental monitoring for special conditions at specific landslides. Table 2 summarizes the overall approach and basic equipment and software requirements.

Open-File Report↗

Experimental Advanced Airborne Research Lidar (EAARL) Data Processing Manual

The Experimental Advanced Airborne Research Lidar (EAARL) is an example of a Light Detection and Ranging (Lidar) system that utilizes a blue-green wavelength (532 nanometers) to determine the distance to an object. The distance is determined by recording the travel time of a transmitted pulse at the speed of light (fig. 1). This system uses raster laser scanning with full-waveform (multi-peak) resolving capabilities to measure submerged topography and adjacent coastal land elevations simultaneously (Nayegandhi and others, 2009). This document reviews procedures for the post-processing of EAARL data using the custom-built Airborne Lidar Processing System (ALPS). ALPS software was developed in an open-source programming environment operated on a Linux platform. It has the ability to combine the laser return backscatter digitized at 1-nanosecond intervals with aircraft positioning information. This solution enables the exploration and processing of the EAARL data in an interactive or batch mode. ALPS also includes modules for the creation of bare earth, canopy-top, and submerged topography Digital Elevation Models (DEMs). The EAARL system uses an Earth-centered coordinate and reference system that removes the necessity to reference submerged topography data relative to water level or tide gages (Nayegandhi and others, 2006). The EAARL system can be mounted in an array of small twin-engine aircraft that operate at 300 meters above ground level (AGL) at a speed of 60 meters per second (117 knots). While other systems strive to maximize operational depth limits, EAARL has a narrow transmit beam and receiver field of view (1.5 to 2 milliradians), which improves the depth-measurement accuracy in shallow, clear water but limits the maximum depth to about 1.5 Secchi disk depth (~20 meters) in clear water. The laser transmitter [Continuum EPO-5000 yttrium aluminum garnet (YAG)] produces up to 5,000 short-duration (1.2 nanosecond), low-power (70 microjoules) pulses each second. Each pulse is focused into an illumination area that has a radius of about 20 centimeters on the ground. The pulse-repetition frequency of the EAARL transmitter varies along each across-track scan to produce equal cross-track sample spacing and near uniform density (Nayegandhi and others, 2006). Targets can have varying physical and optical characteristics that cause extreme fluctuations in laser backscatter complexity and signal strength. To accommodate this dynamic range, EAARL has the real-time ability to detect, capture, and automatically adapt to each laser return backscatter. The backscattered energy is collected by an array of four high-speed waveform digitizers connected to an array of four sub-nanosecond photodetectors. Each of the four photodetectors receives a finite range of the returning laser backscatter photons. The most sensitive channel receives 90% of the photons, the least sensitive receives 0.9%, and the middle channel receives 9% (Wright and Brock, 2002). The fourth channel is available for detection but is not currently being utilized. All four channels are digitized simultaneously into 65,536 samples for every laser pulse. Receiver optics consists of a 15-centimeter-diameter dielectric-coated Newtonian telescope, a computer-driven raster scanning mirror oscillating at 12.5 hertz (25 rasters per second), and an array of sub-nanosecond photodetectors. The signal emitted by the pulsed laser transmitter is amplified as backscatter by the optical telescope receiver. The photomultiplier tube (PMT) then converts the optical energy into electrical impulses (Nayegandhi and others, 2006). In addition to the full-waveform resolving laser, the EAARL sensor suite includes a down-looking 70-centimeter-resolution Red-Green-Blue (RGB) digital network camera, a high-resolution color infrared (CIR) multispectral camera (14-centimeter-resolution), two precision dual-frequency kinematic carrier-phase global positioning system (GPS) receivers, and an

Open-File Report↗

Accuracy assessment/validation methodology and results of 2010–11 land-cover/land-use data for Pools 13, 26, La Grange, and Open River South, Upper Mississippi River System

Introduction/Background The U.S. Geological Survey (USGS)-Upper Midwest Environmental Sciences Center (UMESC) was responsible for development of several land cover/land use (LCU) systemic datasets of the Upper Mississippi River System (UMRS). These efforts (1989 and 2000) were funded by the U.S. Army Corps of Engineers’ Upper Mississippi River Restoration Program (UMRR) Long Term Resource Monitoring (LTRM) element. Development of systemic datasets includes the acquisition, processing, and serving of high-resolution aerial photography and land cover/land use spatial datasets ( http://www.umesc.usgs.gov/data_library/land_cover_use/land_cover_use_data.html ). In 2008, the UMRR reached a collaborative agreement with the U.S. Fish and Wildlife Service-Region 3 to collect high-resolution digital imagery of the entire UMRS floodplain during 2010–11 for LTRM. The UMESC helped acquire, process, and serve this imagery, as well as produce and serve the 2010–11 LCU systemic dataset of the UMRS floodplain. Digital imagery for Pools 13, 26, La Grange, and Open River South was collected using an Applanix DSS 439 digital sensor system with a 40 millimeter lens and Color Infrared (CIR) filter. The imagery was collected at a resolution of 20 centimeters/pixel (8 inches/pixel) for Pool 13 and 40 centimeters/pixel (16 inches/pixel) for Pools 26, Open River South, and La Grange. All imagery was projected to Universal Transverse Mercator (UTM) Zone 15, North American Datum of 1983 (NAD 83). The General Wetland Vegetation Classification (GWVC) system used for mapping is hierarchical, and its 31 classes can be collapsed into broader categories using either a 15- or 7-class level. While the 1989 and 2000 LCU systemic datasets have not gone through a traditional thematic accuracy assessment (AA) in the past, nor have they undergone a validation analysis, the end products are of high quality. For each systemic dataset produced (1989, 2000, 2010–11), extensive field reconnaissance is performed before photointerpretation. The intent of this field reconnaissance is to learn, test, and verify image signatures as they relate to vegetation types. Questionable areas on the imagery are visited, and the plants or land features observed in the area are recorded for reference. This procedure verifies vegetation signatures on the imagery with those on the ground. In addition, once the photointerpretation is complete, the final LCU dataset undergoes extensive quality assurance/quality control to ensure the imagery is mapped correctly. Since the 2000 LCU systemic dataset was developed, there has been a growing interest in completing thematic AAs for the LTRM LCU spatial datasets. The objective of an AA is to measure the probability that a particular location has been assigned its correct vegetation class. An AA estimates thematic (map class) errors in the data, giving users information needed to determine data suitability for a particular application. At the same time, data producers are able to learn more about the nature of errors in the data. Thus, the two attributes of an AA are “producers’ accuracy,” which is the probability that an AA point has been mapped correctly (also referred to as an error of omission); and “users’ accuracy,” which is the probability that the map actually represents what was found on the ground (also referred to as error of commission). Producers’ and users’ accuracies can be obtained from the same set of data by using different analyses. Accuracy assessment is an extensive effort that requires seasonal field personnel and equipment, data entry, analyses, and post processing—tasks that are costly and time consuming. The geospatial team at the UMESC has suggested a validation process for understanding the accuracy of the spatial datasets, which will be tested on at least some areas of the UMRS. Validation is not a true verification of map-class type in the field; however, it can provide the user of the map with useful information that is similar to a field AA. Similar to an AA, validation involves generating random points based on the total area for each map class. However, instead of collecting field data, two or three individuals not involved with the photo-interpretative mapping separately review each of the points onscreen and record a best-fit vegetation type(s) for each site. Once the individual analyses are complete, results are joined together and a comparative analysis is performed. The objective of this initial analysis is to identify areas where the validation results were in agreement (matches) and areas where validation results were in disagreement (mismatches). The two or three individuals then perform an analysis, looking at each mismatched site, and agree upon a final validation class. (If two vegetation types at a specific site appear to be equally prevalent, the validation team is permitted to assign the site two best-fit vegetation types.) Following the validation team’s comparative analysis of vegetation assignments, the data are entered into a database and compared to the mappers’ vegetation assignments. Agreements and disagreements between the map and validation classes are identified, and a contingency table is produced. This document presents the AA processes/results for Pools 13 and La Grange, as well as the validation process/results for Pools 13 and 26 and Open River South.

Iowa, Illinois, Minnesota, Missouri, Wisconsin↗

Geochemistry and microbiology of groundwater and solids from extraction and monitoring wells and their relation to well efficiency at a Federally operated confined disposal facility, East Chicago, Indiana

In cooperation with the U.S. Army Corps of Engineers, Chicago District, the U.S. Geological Survey investigated the processes affecting water quality, geochemistry, and microbiology in representative extraction and monitoring wells at a confined disposal facility (CDF) in East Chicago, Indiana. The CDF is a 140-acre Federally-managed facility that was the former location of an oil refinery and is now used for the long-term disposal and storage of dredge material from the Indiana Harbor and Indiana Harbor Canal. Residual petroleum hydrocarbons and leachate from the CDF are contained within the facility by use of a groundwater cutoff wall. The wall consists of a soil-bentonite slurry and a gradient control system made up of an automated network of 96 extraction wells, 42 monitoring wells, and 2 ultrasonic sensors that maintain an inward hydraulic gradient at the site. The pumps in the extraction wells require vigilant maintenance and must be replaced when unable to withdraw water at a rate sufficient to maintain the required inward gradient. The wells are screened in the Calumet aquifer, a coarse-grained sand and gravel unit that extends approximately 35 feet below the land surface and is not utilized for drinking-water supply at the CDF or in the surrounding area. This study was initiated to identify the cause of decreased pump discharges and to identify potential mitigation strategies. For this study, the U.S. Geological Survey collected groundwater and solids from monitoring and extraction wells. Groundwater samples were collected during June 2014 for precautionary health screening and on four occasions during September 2014 through November 2014. Groundwater samples collected from two extraction wells during June 2014 were analyzed for concentrations of anthropogenic organic constituents. During September through November 2014, groundwater samples were collected from one additional extraction well, and samples from three monitoring wells were analyzed for concentrations of inorganic and organic constituents, dissolved gases, and bacterial abundance and diversity. Solid samples were collected during April 2014, during September 2014 through November 2014, and during November 2016. Solid samples were collected from the exterior of extraction-well pumps and as flocculent from water samples. Solid samples were collected from 10 wells, including 1 extraction well and 3 monitoring wells sampled for water quality. Solid samples were analyzed for mineralogy, solid-phase habit, geochemistry, and organic composition. The following is a list of observations that were made during this study: (1) the water quality is substantially variable among the six well locations sampled as part of this study—lower (more negative) redox values and higher concentrations of many constituents (including calcium, magnesium, sodium, and sulfate) and properties (including dissolved solids, hardness, and turbidity) were detected in sampled wells located near the extraction wells with the highest frequency of failure; (2) water-level drawdown is variable between extraction wells—wells with the greatest drawdown may pull deeper groundwater into the borehole; (3) dissolved gas results indicate reducing oxidation-reduction processes in the aquifer material that can feasibly contribute iron, carbon dioxide, and other byproducts from hydrocarbon degradation to precipitates and solids that accumulate on and impair pump operation; (4) crystalline and amorphous solid-phase minerals are precipitating in the borehole; (5) several types of bacteria are present in water pumped from extraction wells and are likely responsible for bonding mineral and microbiologic matter to the pump (and other well components); and (6) bacteria may create microenvironments that facilitate precipitation of solids or inhibit dissolution of unstable minerals once the bacteria adhere to biofilm attached to the pump. Results of the study indicate that bacteria may be accumulating and entrapping solid material on the exterior of pumps. This accumulation reduces heat transfer and water discharge from the pump and may lead to decreased efficiency or mechanical failure. Observations could not be made on the well screen, gravel pack, or surrounding geologic formation; therefore, mitigating measures in the borehole may not solve well-productivity issues. Remedies for the pump fouling problems were derived from the review and interpretation of data collected during this study and from information documented in other sources about groundwater well fouling. Potential remedies to problems associated with pump fouling at the CDF may include the following: (1) reducing attractiveness of the extraction wells for microbiological growth by modifying the chemical or physical environment of the well, (2) modifying the pump exterior to decrease microbiological adherence, (3) changing the pumping regime to control the chemistry of water entering the well from the surrounding aquifer material, (4) modifying the pumps to be less physically and thermally attractive, and (5) removing hydrocarbons from groundwater and the aquifer material surrounding the wells or adding surfactants to make them more mobile. Pilot scale testing may be necessary to identify the most effective treatment or combination of treatments.

Indiana↗