USGS ScienceSearch

SEARCH · USGS Science

Results for “International Journal for Disaster Risk Reduction”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,443 records · Page 42Linked to original sources

Groundwater-level elevations in the Denver Basin bedrock aquifers and Upper Black Squirrel Creek alluvial aquifer, El Paso County, Colorado, 2021–24

El Paso County is the second-most populous county in Colorado and is projected to grow another 15 percent by 2030. Within El Paso County is the Upper Black Squirrel Creek Designated Groundwater Basin (Black Squirrel Basin), an area where surface water is scarce and water users rely primarily on groundwater from five different aquifers (the Upper Black Squirrel Creek alluvial aquifer and four bedrock aquifers within the Denver Basin aquifer system: the lower Dawson, Denver, Arapahoe, and Laramie-Fox Hills aquifers) to meet their needs. Currently (2024), land within the Upper Black Squirrel Creek Basin is primarily used for rural grazing and agriculture; however, municipal development is ongoing. In 2021, the U.S. Geological Survey, in cooperation with the Upper Black Squirrel Creek Ground Water Management District, began a study to establish a baseline dataset and assess the groundwater resources of the aquifers within the Black Squirrel Basin. A network of 39 wells was established in 2021; discrete groundwater-level measurements were made bimonthly. Nine of the 39 wells were equipped with pressure transducers to record hourly groundwater-level data. Seven wells had statistically significant seasonal trends, and trends at 3 wells were negative. For the discrete data, 16 wells had a significant trend for the study period, and 4 wells had negative trends. For the time-series data, 8 wells had significant trends, and 3 wells had negative trends. Potentiometric surface maps were created for this study using discrete, static groundwater levels measured in April 2023. These maps showed the estimated groundwater flow direction from the north-northwest to the south-southeast in the alluvial aquifer and from the northwest to the east-southeast for the lower Dawson and Denver aquifer wells. This study indicates the potential benefit of monitoring wells in the areas near municipal pumping. Additional monitoring could lead to a better understanding of connectivity between aquifers and be an important tool for assessing long-term sustainability of groundwater use.

Colorado

Comparison of two approaches for determining ground-water discharge and pumpage in the lower Arkansas River Basin, Colorado, 1997-98

In March 1994, the Colorado Division of Water Resources (CDWR) adopted “Rules Governing the Measurement of Tributary Ground Water Diversions Located in the Arkansas River Basin” (Office of the State Engineer, 1994); these initial rules were amended in February 1996 (Office of the State Engineer, 1996). The amended rules require users of wells that divert tributary ground water to annually report the water pumped monthly by each well. The rules allow a well owner to report the pumpage measured by a totalizing flowmeter (TFM) or pumpage determined from electrical power data and a power conversion coefficient (PCC) (Hurr and Litke, 1989). Opinions by representatives of the State of Kansas, presented before the Special Master hearing a court case [State of Kansas v. State of Colorado, No. 105 Original (1996)] concerning post-Compact well pumping, stated that the PCC approach does not provide the same level of accuracy and reliability as a TFM when used to determine pumpage. In 1997, the U.S. Geological Survey (USGS), in cooperation with the CDWR, began a 2-year study to compare ground-water pumpage estimates made using the TFM and the PCC approaches. The study area was along the Arkansas River between Pueblo, Colorado, and the Colorado-Kansas State line (fig. 1). The two approaches for estimating ground-water discharge and pumpage were compared for more than 100 wells completed in the alluvial aquifer of the Arkansas River Basin. The TFM approach uses an inline flowmeter to directly measure instantaneous discharge and the total volume of water pumped at a well. The PCC approach uses electrical power consumption records and a power conversion coefficient to estimate the pumpage at ground-water wells. This executive summary describes the results of the comparison of the two approaches. Specifically, (1) the differences in instantaneous discharge measured with three portable flowmeters and measured with an inline TFM are evaluated, and the statistical differences in paired instantaneous discharge between the two approaches are determined; (2) short- and long-term variations in the PCC’s are presented; (3) differences in pumpage between the two approaches are evaluated, and the statistical differences in pumpage between the two approaches are determined; (4) potential sources of discrepancy between pumpage estimates are discussed; and (5) differences in total network pumpage using the two approaches are presented. During the irrigation seasons of 1997 and 1998, instantaneous discharge and electrical power demand were measured at randomly selected wells to determine PCC’s. At more than 100 wells, the PCC’s determined during the 1998 season were applied to total electrical power consumption data that was recorded between the initial and final readings at each network well site in 1998 to estimate total ground-water pumpage. At each site, an inline TFM was installed in a full-flowing, acceptable test section of pipe on the discharge side of the pump where the measurement of discharge was made. Measurements of instantaneous ground-water discharge also were made using three different types of portable flowmeters. The average velocity multiplied by the cross-sectional area of the discharge pipe was used to compute the discharge in gallons per minute. Whenever possible, discharge measurements were made at each network site using all three types of portable flowmeters.

Colorado

Detection of viral, bacterial, and protozoan pathogens and microbial source tracking markers in paired large- and small-volume water samples

When sampling for waterborne microbes, researchers may need to diverge from recommended sample volumes due to logistical constraints, novel targets, or challenging matrices, with little guidance about the potential impact on results. In field studies, we measured bacteria, viruses, and protozoa (15 quantitative polymerase chain reaction assays) in paired large- and small-volume samples to evaluate method performance and relevant factors. Concordance between methods was low. Large-volume ultrafiltration yielded more detections than small-volume sampling, especially for pathogens in groundwater. Greater microbial concentrations were associated with more frequent detections in small-volume samples and greater concordance between paired samples. Large-volume samples appeared to be more susceptible to diminished sensitivity from complex sample matrices. In laboratory studies, recovery of microbes was poorer for large- than small-volume methods, although large-volume methods more reliably detected low-concentration targets. Large-volume samples were less stable than small-volume samples during storage. Overall, large-volume sampling was superior for detecting pathogens but may underestimate concentrations; small-volume sampling was more prone to false negatives but was adequate when concentrations were relatively high, like we observed for microbial source tracking in surface waters.

Wisconsin

Did they feel it? Legacy maroseismic data illuminates an engimatic 20th century earthquake

The challenges and the importance of preserving legacy instrumental records of earthquakes are now well-recognized (e.g., Richards & Hellweg, 2020, https://doi.org/10.1785/0220200053 ). Seismologists may not be aware of parallel challenges and opportunities with legacy macroseismic data for earthquakes in the United States. For much of the 20th century, macroseismic data were collected by a series of U.S. government agencies using a standard questionnaire distributed on postcards. Published summaries of postcards provide macroseismic data akin to modern Did You Feel It? questionnaire responses. In this paper we focus on the M 6.5 Fickle Hill, California earthquake, on 21 December 1954 (Hellweg et al., 2025) as a proof-of-concept, illustrating the potential of what we dub Did They Feel It? (DTFI) data to improve our understanding of significant 20th century U.S. earthquakes for which instrumental data are sparse. Legacy macroseismic data interpreted following modern conventions can potentially constrain traditional ShakeMaps at a level of detail and accuracy that in some respects rival maps for modern earthquakes. The updated ShakeMap for the 1954 Fickle Hill earthquake, also drawing from recently published media and first-person accounts, supports the location, depth, and stress drop value estimated from available instrumental data (Hellweg et al., 2025).

California

Sensitivity of Alabama freshwater gastropod species to nickel exposure

Snails are effective bioindicators due to their prolific distribution, high level of endemism, and capacity to accumulate contaminants. Freshwater snails have unique ecological niches which are imperiled by land‐use change and the introduction of hazardous chemicals. To assess how environmental alterations affect gastropods, lab‐based studies are needed to characterize the toxicity of specific stressors. This can help guide policy decisions and remediation efforts. The aim of this research was to characterize acute toxicity of nickel (Ni) on endemic snails ( Somatogyrus georgianus [Walker, 1904], Elimia cahawbensis [Lea, 1861], and Elimia spp.) and measure the accumulation of Ni and mineral elements including calcium (Ca), magnesium, potassium, and sodium (Na). Snails were exposed to six concentrations (25–800 µg/L) of Ni for 96 h. Among the studied snail species, E. cahawbensis was the most sensitive to Ni, with the lowest lethal concentration where 50% of the organisms died (LC50) at 88.88 µg/L Ni after 96 h. The LC50 at 96 h for S. georgianus was 167.78 µg/L Ni, and 393.13 μg/L Ni for Elimia spp. Except for Elimia spp., mortality of the other two snail species corresponded to the whole‐body uptake of Ni. Nickel exposure also influenced Ca and Na uptake for Elimia spp. All three endemic species are potential candidate species for evaluating localized effects of human activities, and the present study provides a first step in characterizing how snails would be affected by environmental alterations. More research could further characterize potential effects of other human stressors on these endemic snail species. Future research into subindividual responses and routes of exposure can further elucidate variations in species sensitivity.

Alabama

Determination of per- and polyfluoroalkyl substances in water by direct injection of matrix-modified centrifuge supernatant and liquid chromatography/tandem mass spectrometry with isotope dilution

A direct-injection liquid chromatography/tandem mass spectrometry method was developed to determine 34 per- and polyfluoroalkyl substances (PFAS), including selected branched isomers, in centrifuge supernatant of matrix-modified (amended with approximately 50 percent methanol) water samples. The method has been validated in reagent water, surface water, groundwater, and wastewater effluent. Other water types (for example, drinking water, untreated wastewater, and landfill leachate) have been analyzed by the method but not systematically validated. Recovery of isotope-dilution standards, added to each sample, may be used to assess method performance in nonvalidated matrices on a sample-by-sample basis. Using this method, PFAS concentrations were determined in the range of 2–2,000 nanograms per liter in water samples. This range can be extended by diluting concentrated samples. At circumneutral pH, most compounds are present in the environment in their ionized form, and data are reported as such (for example, perfluorooctanoic acid is referred to as “perfluorooctanoate” [PFOA], perfluorooctane sulfonic acid is referred to as “perfluorooctane sulfonate” [PFOS]). Sample preparation procedures were designed without the use of filtration and with minimum sample handling steps to mitigate procedural losses of target compounds due to sorption to surfaces. Further, isotope-dilution quantification allowed for the correction of bias that may result from procedural losses, matrix-induced signal suppression or enhancement, and other factors. Validation experiments to characterize bias and variability, method detection level, and holding time were done in four distinct water matrices—reagent water, surface water, treated wastewater effluent, and groundwater—at multiple concentration levels. Mean PFAS recoveries met data quality objectives of bias and variability studies in all four validation matrices except for two compounds with low and variable recovery in the reagent water matrix only. Isotope-dilution standards, treated as surrogate compounds, were analyzed in more than 1,500 customer-submitted environmental samples with aggregate recovery of 102.5±6.5 percent (mean±standard deviation). Maximum holding times for all target compounds in the four validation matrices were 28 days for refrigerated samples and 90 days for frozen samples.

Techniques and Methods

Relationship between peak and cumulative ground motions from 49 Mw 3-6 earthquakes in the San Francisco Bay Area

We examine the relationship between peak ground velocity (PGV) and cumulative absolute displacement (CAD) for 49 M w 3 – 6 earthquakes in the San Francisco Bay Area (SFBA) and gain insight into the spatiotemporal partitioning of seismic energy in ground motion records with respect to source, path, and site effects. PGV and CAD are positively correlated, but there can be large deviations from the average trend. For example, ground motion records with either very long duration resonance or short pulse-like motions will have higher or lower CAD, respectively, but could have very similar PGV. We perform principal component analysis (PCA) on PGV-CAD for >7000 records in the SFBA with the goal of investigating what influences positive or negative anomalies in cumulative motions. PCA rotates the PGV-CAD datapoints into two principal components, where the one with the larger variance, which we call the “primary intensity” represents mostly the distance-dependence of ground motion amplitudes. The other principal component, which we call the “excess motion”, represents the deviation from cumulative motions that would be typical for a ground motion record with a given PGV. The excess motion will be positive in the case of records with long duration ringing and will be negative for short duration pulse-like ground motions. We find that excess motion is generally positive at sites in sedimentary basins and in soft sediments around the SF Bay. Excess motion is generally negative in the very near field, as well as at sites on hard bedrock. We discuss the findings here in terms of implications for seismic hazard applications and other wave propagation phenomena.

California

Enhancing mineral systems exploration through geochronology, thermochronology, and isotope analysis: USGS Geochron and USGS Isotope databases

A mineral systems approach to mineral exploration provides a comprehensive framework for understanding ore deposit formation by examining the geodynamic, magmatic, hydrothermal, and sedimentary processes responsible for mineralization, alteration, and remobilization of economic mineral deposits. Temporal and thermal constraints on ore genesis are crucial for refining mineral system models and guiding predictive exploration strategies. Geochronology and thermochronology offer invaluable insights into the timing and thermal evolution of ore-forming processes, whereas isotopic analyses provide critical information on the source and geochemical history of ore-forming fluids. Combining these methodologies have proven highly effective for mineral exploration in regions like Australia, however, their combined application has been limited in the United States. To apply these tools to mineral systems-based exploration, the U.S. Geological Survey (USGS) has developed two products: (1) The USGS Geochron Database, and (2) the USGS Isotope Database. These databases provide centralized repositories of geo/thermochronological dates and data (Geochron Database) and both radiogenic and stable isotope data (Isotope Database) generated by the USGS and partners over the past decades. Integrating these datasets together and with traditional exploration approaches provides the mineral exploration community with powerful tools for determining the temporal and thermal histories of ore systems and identifying metallogenic source provinces.

Continental United States

Fiber-imaged supershear dynamics in the 2024 Mw 7 Mendocino Fault earthquake

Fault structure and rupture physics are deeply intertwined, and observations of this coupling are critical for understanding earthquake behavior. Rupture propagation is observable at fine scales using dense seismic networks. Fiber-optic sensing allows for long-term deployments of ultradense arrays that enable high-resolution measurements of infrequent, large earthquakes. We recorded the 2024 moment magnitude ( M w ) 7 Mendocino Fault earthquake with a nearby fiber-optic array and imaged its behavior with seismic beamforming. The rupture propagated to the east at subshear velocity; stagnated near the Mendocino Triple Junction, a zone of structural complexity; and subsequently transitioned to supershear velocity. The correlation between source physics and structure shows how lithospheric heterogeneity affects first-order characteristics of earthquake ruptures. Our results also demonstrate the potential for fiber-optic sensing to improve real-time estimation of key parameters for early warning.

California

Potentiometric surface maps and groundwater-level hydrographs for confined aquifers of the New Jersey Coastal Plain, 2018

The U.S. Geological Survey, in cooperation with the New Jersey Department of Environmental Protection (NJDEP), prepared potentiometric surface maps for 10 confined aquifers of the New Jersey Coastal Plain physiographic province based on water-level measurements collected during late 2018 and early 2019 from 951 wells in New Jersey and parts of Pennsylvania and Delaware. Maps were prepared for the confined Cohansey aquifer, Rio Grande water-bearing zone, Atlantic City 800-foot sand, Piney Point aquifer, Vincentown aquifer, Wenonah-Mount Laurel aquifer, Englishtown aquifer system, and the upper, middle, and lower aquifers of the Potomac-Raritan-Magothy aquifer system. Potentiometric surface maps indicate regional cones of depression in the following aquifers and the counties in which they are centered: Atlantic City 800-foot sand in Atlantic County, the Piney Point aquifer in Cumberland County, the Wenonah-Mount Laurel aquifer and Englishtown aquifer system in Monmouth and Ocean Counties, the Wenonah-Mount Laurel aquifer in Camden and Gloucester County, the upper aquifer of the Potomac-Raritan-Magothy aquifer system in Ocean County, and the upper, middle, and lower aquifers of the Potomac-Raritan-Magothy aquifer system in Camden County. Cones of depression with smaller areal extents were in the confined Cohansey aquifer, the Rio Grande water-bearing zone, the Atlantic City 800-foot sand centered in Cape May County, the Piney Point aquifer centered in Ocean County, the Wenonah-Mount Laurel aquifer in Salem and Burlington Counties, the Englishtown aquifer system in Camden County, the upper aquifer of the Potomac-Raritan-Magothy aquifer system in Monmouth County, and the middle aquifer of the Potomac-Raritan-Magothy aquifer system in Monmouth, Ocean, and Salem Counties. No cone of depression was interpreted in the Vincentown aquifer. Long-term hydrographs are presented for 75 wells spanning each of the 10 confined aquifers, and contain a mix of discrete water-level measurements and daily mean water levels based on continuously recorded 15-minute data. Changes of water levels during 2014–19, as indicated by the hydrographs, were compared with those of previous periods to assess any departures from historical data. During 2014–19, water levels were stable and fluctuated within similar ranges as previous periods in the following aquifers and locations: all wells in the confined Cohansey aquifer, the Rio Grande water-bearing zone, the Vincentown aquifer, the Englishtown aquifer system, the Piney Point aquifer wells in Burlington and Ocean Counties, six of eight wells in the Wenonah-Mount Laurel aquifer, all wells in the upper and lower aquifers of the Potomac-Raritan-Magothy aquifer system outside NJDEP Critical Areas, and all wells in the middle aquifer of the Potomac-Raritan-Magothy aquifer system except those within NJDEP Critical Area II. Increasing water levels in 2014–19, ongoing since historical periods, were indicated in the following aquifers and locations: Atlantic County wells in the Piney Point aquifer, all wells in the upper and lower aquifers of the Potomac-Raritan-Magothy aquifer system outside NJDEP Critical Areas, and all wells in the middle aquifer of the Potomac-Raritan-Magothy aquifer system within NJDEP Critical Area II. Water levels in the Atlantic City 800-foot sand also increased during 2014–19 in wells in Atlantic County and northern Cape May County closer to the center of the cone of depression in that aquifer, which is a response unique to this period and absent from previous periods. During 2013–19, continued decreasing water levels, ongoing since previous periods, were indicated by hydrographs of Atlantic City 800-foot sand wells in southern Cape May County, Piney Point aquifer wells in Cumberland County where the regional cone of depression is located, and two wells in the Wenonah-Mount Laurel aquifer—070478, which in 2014–19 departed from previous periods, and 330020, which continued a gradual decrease throughout its period of record.

New Jersey

Hydrogeologic framework and conceptual model of the Red River alluvial aquifer east of Lake Texoma, southeastern Oklahoma, 1980–2022

The 1973 Oklahoma Groundwater Law (Oklahoma Statutes §82-1020.5) requires that the Oklahoma Water Resources Board conduct hydrologic investigations of the State’s groundwater basins to support a determination of the maximum annual yield for each groundwater basin. At present (2025), the Oklahoma Water Resources Board has not established a maximum annual yield for the Red River alluvial aquifer east of Lake Texoma. To support the evaluation and determination of a maximum annual yield, a hydrogeologic framework and conceptual groundwater-flow model were developed to assess groundwater availability in the Red River alluvial aquifer east of Lake Texoma. The scope of this hydrologic investigation is the alluvium and terrace containing the Red River alluvial aquifer in Oklahoma between Lake Texoma, the Texas State line, and the Arkansas State line, an extent referred to in this report as “the eastern part of the Red River alluvial aquifer.” Parts of the alluvium and terrace extent in Arkansas and Texas are included in some analyses to address hydrologic influences from outside the aquifer’s boundaries in Oklahoma. The eastern part of the Red River alluvial aquifer in southeastern Oklahoma consists of approximately 401,280 acres of Quaternary alluvium and terrace deposits associated with the Red River and its major tributaries. Mean annual recharge to the aquifer for the 1980–2022 study period was estimated to be 8.62 inches per year, or 17.98 percent of the mean annual precipitation over the same period (47.94 inches). This mean annual recharge rate is equivalent to an inflow of approximately 288,250 acre-feet per year for the eastern part of the Red River alluvial aquifer. Recharge estimated using the Soil-Water-Balance code accounts for 98.7 percent of the conceptual-model inflows to the eastern part of the Red River alluvial aquifer. Saturated-zone evapotranspiration accounts for 11.9 percent and net streambed seepage accounts for 87.4 percent of the outflows in the conceptual model.

Arkansas, Oklahoma, Texas

Evaluating the potential of co-located non-petroleum energy resources in the Gulf Coast using play fairwayaAnalysis

Geological resources critical to the energy transition, such as sedimentary geothermal, carbon storage potential, and lithium in brines, commonly struggle for economic feasibility as stand-alone developments but can have greater viability when the potential for more than one of these resources exist within the same reservoir or stacked in different stratigraphic intervals. There may also be instances where development of one resource inhibits development of others and decisions need to be made on how to best prioritize the use of those resources in the subsurface. Subsurface data sets were analyzed and integrated to evaluate the distribution of non-petroleum energy and related resources in the onshore and nearshore U.S. Gulf Coast. Temperature, pressure, brine composition (lithium content), and reservoir quality data for thirty-four depositional units have been compiled and visualized to high-grade areas where multiple resource opportunities likely coexist. For sedimentary geothermal, possible resource areas are defined as low potential (<90°C), moderate potential (90–150°C), and high potential (>150°C). For CO 2 storage, high potential areas exhibit supercritical CO 2 conditions less than 80% of the fracture gradient. Areas with pore pressure between 80% and 100% of the fracture gradient are considered to exhibit moderate potential and areas where the fracture gradient is equal to or greater than 100% are assigned low potential. Lithium resources in brines were defined by lithium concentrations as low potential (<100ppm), moderate potential (100-200ppm), or high potential (>200ppm). Reservoir quality affects the viability of all three of these resources and is evaluated using depositional environment maps of each unit. The resulting play fairway maps can be used for regional scale screening evaluations of these resources and to identify areas of interest where more detailed, prospect-scale studies can be undertaken.

Gulf Coast

Streamflow, base flow, and ground-water recharge in the Housatonic River basin, western Massachusetts and parts of eastern New York and northwestern Connecticut

Streamflows for selected flow durations from 1 to 99 percent and the August median streamflows were estimated for 11 long-term streamflow-gaging stations in and near the study area. Estimates of streamflow and associated standard errors were determined for selected flow durations from 50 to 99 percent and the August median streamflows for 21 low-flow partial-record stations and for selected flow durations from 1 to 99 percent and the August median streamflows for two partial-record stations and seven short-term discontinued streamflow-gaging stations. Median streamflows per square mile for the 10-, 50-, and 90-percent flow durations and the August median streamflows were 3.90, 1.01, 0.185, and 0.248 cubic feet per second per square mile. Streamflows per square mile at selected flow-duration discharges between 1 and 99 percent at the 41 stations were related to basin characteristics to explain differences in streamflow characteristics. Basin characteristics included basin elevations, extent of stratified-drift deposits, land use, aspect, and underlying bedrock geology types. Most streamflow differences were positively correlated to basin elevation differences, most likely because precipitation increases with elevation, and to stratified-drift deposits, which allow more precipitation to recharge the ground water and to discharge later than do till and bedrock deposits. Mean base flow was computed from continuous records of daily mean discharge at 11 long-term streamflow-gaging stations in and near the study area. Mean annual base flow ranged from 13.4 to 24.5 inches per year. Minimum annual base flow ranged from 45 to 72 percent of mean annual rates at the 11 long-term stations, and the ratio of base flow to streamflow (base-flow index) ranged from 0.55 to 0.80. Base-flow durations between 1 and 99 percent were calculated from streamflow records at the 11 long-term streamflow-gaging stations. Base flow accounted for 45.5 to 85.0 percent of total annual streamflow at the 1- and 99-percent flow durations. Ground-water-recharge rates were computed from continuous records of daily mean discharge at 11 long-term streamflow-gaging stations in and near the study area. Mean annual ground-water-recharge rates ranged from 17.5 to 22.4 inches per year at 10 of the 11 long-term stations. Mean annual ground-water-recharge rates ranged from 2 to 7 inches per year higher than base flow. Minimum annual ground-water-recharge rates ranged from 48 to 72 percent of mean annual ground-water-recharge rates. Mean annual potential ground-water recharge was estimated from monthly climatological data collected at six climatological stations in and near the study area. Mean potential ground-water recharge ranged from about 17.9 to 28.9 inches per year, with a median value of 22.6 inches per year. This median value compares well to that calculated by use of streamflow records at the 11 streamflow-gaging stations (20.0 inches per year). Streamflows per square mile for the 10-, 50-, and 90-percent flow durations at stations in and near the study area were similar to those computed for other unregulated long-term continuous streamflow-gaging stations in central and eastern Massachusetts. Base-flow and ground-water-recharge rates in the study area compared closely to results from other studies in southeastern Massachusetts and Rhode Island, which were based on the same computational methods.

Connecticut, Massachusetts, New York

Streams, springs, and volcanic lakes for volcano monitoring

Introduction Volcanic unrest can trigger appreciable change to surface waters such as streams, springs, and volcanic lakes. Magma degassing produces gases and soluble salts that are absorbed into groundwater that feeds streams and lakes. As magma ascends, the amount of heat and degassing will increase, and so will any related geochemical and thermal signal. Subsurface magma movement can cause pressurization that alters hydrostatic head and may induce groundwater discharge. Fluid-pressure changes have been linked to distal volcano-tectonic earthquakes (White and McCausland, 2016; Coulon and others, 2017) and phreatic eruptions (for example, Yamaoka and others, 2016). Clearly, changes in groundwater and surface waters are both indicators of unrest and clues to how and where magma is rising toward the surface. Where possible, it is prudent to incorporate real-time hydrologic data into multiparameter monitoring of restless volcanoes. Hydrologic dynamics can also be tracked by changes in groundwater levels that are commonly measured in shallow boreholes (see of Flinders, A.F., Lowenstern, J.B., Coombs, M.L., and Poland, M.P., eds., Recommended capabilities and instrumentation for volcano monitoring in the United States: U.S. Geological Survey Scientific Investigations Report 2024–5062–K, 5 p., https://doi.org/10.3133/sir20245062k. ">chapter K , this volume, on boreholes; Hurwitz and Lowenstern, 2024). Although inferred to be common, relatively few volcano-hydrology anomalies are well documented, and many are essentially anecdotal (Newhall and others, 2001), reflecting the fact that high-resolution time series remain rare. Extreme examples include the 2008 eruption of Nevado del Huila, Colombia, where relatively minor phreatomagmatic eruptions were accompanied by expulsion of as much as 300 million cubic meters of groundwater from fissures high on the volcano (Worni and others, 2011), generating large lahars. Substantial decreases in flow rate from springs about 8 kilometers from the summit of Mayon Volcano, Philippines, have been noted before most eruptions in the 20th century (Newhall and others, 2001). Stream monitoring at Redoubt Volcano in 2009 allowed Werner and others (2012) to recognize that groundwater was unable to absorb (or scrub) the high flux of volcanic gas and that a high CO 2 /SO 2 precursor signal had been evident for 5 months prior to the eruption. A key to better interpreting hydrologic anomalies—or even identifying them—is therefore obtaining adequate baseline data. Most hydrologic monitoring at U.S. volcanoes has been accomplished by intermittent sampling surveys with annual or less frequent sampling (for example, https://hotspringchem.wr.usgs.gov/index.php ). More frequent sampling, however, generally is needed to establish reliable baselines. A recent hydrologic and hydrothermal monitoring experiment at 25 sites and 10 of the 12 level 4 (very high threat) volcanoes in the U.S. portion of the Cascade Range demonstrated that there is sufficient temporal variability in hydrothermal fluxes, even during quiescent periods, that one-time measurements will commonly have limited interpretive value (Crankshaw and others, 2018). Thus, surveys are best augmented with data from streamgages (for example, Evans and others, 2004; Bergfeld and others, 2008). Streamflow (water discharge) data allow measured temperature and specific conductance to be converted to heat and solute mass fluxes, which could be insightful parameters for detecting anomalous activity (McCleskey and others, 2012). At the Yellowstone Caldera, long-term monitoring of river solutes has allowed calculation of the chloride flux, a proxy for heat discharge (Hurwitz and others, 2007; McCleskey and others, 2016) from the subsurface magma. This is readily accomplished because data from streamgages are continuously recorded and archived by the U.S. Geological Survey (USGS) National Water Information System (NWIS) (USGS, 2024). Similar studies on stratovolcanoes or shield volcanoes would be scientifically useful, and yet are logistically challenging, requiring streamgages on numerous radial drainages complemented by either frequent manual sampling or numerous deployments of equipment to measure water temperature and specific conductance as a proxy for water chemistry. Another challenge is that some volcanic areas, especially shield volcanoes, are characterized by near-surface porous rocks and soils, such that surface streams are rare and replaced by distant, dilute large-volume springs with only a trace of any original volcanically sourced water (Manga, 2001; Hurwitz and others, 2021). Volcanic lakes are worthy of special attention for monitoring efforts, as their temperature and composition can provide evidence of increased flux of volatile-rich fluids from below. Quantifying changes in volatile and heat release from magma can be simpler in lakes than for volcanoes with radial drainages and no major lakes. Moreover, volcanic lakes pose a range of hazards themselves, including phreatomagmatic eruptions, debris flows, flank collapse, tsunamis, and toxic gas release (Mastin and Witter, 2000; Delmelle and others, 2015; Manville, 2015; Rouwet and others, 2015)—hazards that have historically been responsible for substantial loss of life at many volcanoes worldwide (Manville, 2015). Catastrophic CO 2 release at Lake Nyos, Cameroon, in 1986 suffocated about 1,750 people and about 3,500 livestock and was probably triggered by a large landslide into the gas-saturated lake (Kling and others, 1987; Evans and others, 1993). Gas-charged springs in Soda Bay within Clear Lake (California) have caused almost a dozen deaths to bathers in the past hundred years (ABC News, 2000). A 2005 example of lake overturn and abundant gas release was documented at Mount Chiginagak in Alaska (Schaefer and others, 2008) but did not result in any human casualties. Although thermally stratified lakes, which promote trapping of exsolved magmatic gas, tend to develop in tropical regions, the phenomenon can also arise where salinity creates meromixis (a condition in which a lake does not mix completely), as occurs in Mono Lake, California (Jellison and Melack, 1993; Jellison and others, 1998). If magma erupts or flows into a lake, the interaction between hot magma and cold water can be explosive (Mastin and others, 2004; Zimanowski and others, 2015) and substantially expand the area affected by the eruption. Another hazard is the breaching of crater rims by landslides triggered by volcanic and (or) seismic activity. Under some circumstances, substantial volumes of water can be displaced, leading to large floods and lahars. Late Holocene lake flooding from Aniakchak Crater in the Alaska Peninsula (Waythomas, 2022) and from Paulina Lake in Newberry Crater, Oregon (Chitwood and Jensen, 2000), caused by the failure of outlet sills, testify to the substantial hazards at lake-filled calderas. Several volcanic systems in the United States host lakes known to receive heat and gas from underlying magma. These lakes vary widely in area, depth, and chemical composition. Lakes are present at level 4 volcanoes, including Crater Lake and Newberry Volcano in Oregon; Yellowstone Caldera in Wyoming; Long Valley Caldera, Clear Lake volcanic field, Medicine Lake, and Salton Buttes in California; and Aniakchak Crater, Mount Katmai, Fisher Caldera, Mount Okmok, and Kaguyak Crater, among others, in Alaska. A water lake was present in Halemaʻumaʻu, the crater of Kīlauea, Hawai‘i (fig. F1), from October 2019 to December 2020. Level 3 volcanoes with lakes include Mono Lake volcanic field (Calif.), Mount Bachelor (Ore.), Ukinrek Maars and Mount Chiginagak (Alaska), and Soda Lake (Nevada). In addition, there are lakes at many levels 1 and 2 volcanoes. In the United States, there are no strongly acidic lakes that receive abundant input of magmatic gas, such as those found at Mount Ruapehu (New Zealand), Ijen and Kelud (Indonesia), and Poás (Costa Rica). Nevertheless, many contain fluids that provide clues to magmatic processes below. Since publication of a previous report on recommended instrumentation for volcano monitoring (Moran and others, 2008), continuous hydrologic monitoring has become increasingly feasible. However, changes in water pressure, temperature, and chemistry remain, in general, poorly studied phenomena at volcanoes (Sparks, 2003; National Academies of Sciences, Engineering, and Medicine, 2017). Recent efforts by the USGS have included the temporary study of Cascade Range volcanoes, which included frequent (15 minute to hourly) temporal sampling of temperature, depth, and conductivity (Crankshaw and others, 2018; Ingebritsen and Evans, 2019). At Yellowstone Caldera, many streamgages have now added thermistors and specific conductance sensors, allowing estimation of time-dependent chloride flux as a proxy for variations in subsurface heat flux (McCleskey and others, 2012, 2016). Efforts to better understand lakes have also accelerated, with bathymetric mapping and sampling carried out at several locations in the United States. Especially thorough work was done at Yellowstone Lake thanks to the Hydrothermal Dynamics of Yellowstone Lake (HD-YLAKE, https://hdylake.org ) project, funded primarily by the National Science Foundation. In addition to geophysical surveys and recovery of cores and other samples, HD-YLAKE investigations included remotely operated vehicle (ROV) investigations of hydrothermal vents on the lake floor (fig. F2). Data collected by the ROV provided a better understanding of the thermal and chemical influx from lake-bottom hydrothermal systems (Sohn and others, 2017). In this chapter, we focus on detecting changes in the chemistry, temperature, discharge, or water levels of streams, springs, and lakes that can be caused by seismicity, volumetric strains, or increases in gas flux associated with ascending magma. There is unavoidable overlap with other chapters of this report. Samples of water and gas can also be obtained in boreholes ( of Flinders, A.F., Lowenstern, J.B., Coombs, M.L., and Poland, M.P., eds., Recommended capabilities and instrumentation for volcano monitoring in the United States: U.S. Geological Survey Scientific Investigations Report 2024–5062–K, 5 p., https://doi.org/10.3133/sir20245062k. ">chapter K , this volume; Hurwitz and Lowenstern, 2024), both shallow and deep. Gas monitoring ( of Flinders, A.F., Lowenstern, J.B., Coombs, M.L., and Poland, M.P., eds., Recommended capabilities and instrumentation for volcano monitoring in the United States: U.S. Geological Survey Scientific Investigations Report 2024–5062–E, 11 p., https://doi.org/10.3133/sir20245062e.">chapter E , this volume; Lewicki and others, 2024) relies in part on samples from springs and wells, particularly where measurable gas plumes are absent. Water acts as a trigger and lubricant for landslides and sediment-rich floods, and so hydrology has obvious relevance for lahar monitoring, as discussed in of Flinders, A.F., Lowenstern, J.B., Coombs, M.L., and Poland, M.P., eds., Recommended capabilities and instrumentation for volcano monitoring in the United States: U.S. Geological Survey Scientific Investigations Report 2024–5062–H, 6 p., https://doi.org/10.3133/sir20245062h. ">chapter H (this volume; Thelen and others, 2024). Shared situational awareness among scientists engaged in geophysical, gas, and hydrologic monitoring will improve overall understanding of the volcanic hazard.

Scientific Investigations Report

Static and dynamic strain in the 1886 Charleston, South Carolina, earthquake

During the 1886 Mw 7.3 Charleston, South Carolina, earthquake, three railroads emanating from the city were exposed to severe shaking. Expansion joints in segmented railroad tracks are designed to allow railroad infrastructure to withstand a few parts in 10,000 of thermoelastic strain. We show that, in 1886, transient contractions exceeding this limiting value buckled rails, and transient extensions pulled rails apart. Calculated values for dynamic strain in the meizoseismal region are in reasonable agreement with those anticipated from the relation between strain and moment magnitude proposed by Barbour et al. (2021) and exceed estimated tectonic strain released by the earthquake by an order of magnitude. Almost all of the documented disturbances of railroad lines, including evidence for shortening of the rails, can thus be ascribed to the effects of dynamic strain changes, not static strain. Little or no damage to railroads was reported outside the estimated 10 −4 dynamic strain contour. The correspondence between 10 −3 and 2×10 −4 contours of dynamic strain and Mercalli intensity 9 and 8, anticipated from the dependence of each quantity on peak ground velocity, suggests it may be possible to use railroad damage to quantitatively estimate shaking intensity. At one location, near Rantowles, ≈20 km west of Charleston, a photograph of buckled track taken one day after the earthquake has been cited as evidence for shallow dextral slip and has long focused a search for a causal fault in this region. Photogrammetric analysis reveals that the buckle was caused by transient contraction of <10 cm with no dextral offset. Our results further weaken the evidence for faulting in the swamps and forests south of the Ashley River in 1886, hitherto motivated by the photograph and limited macroseismic evidence for high‐intensity shaking.

South Carolina

Dynamic baseflow storage estimates and the role of topography, geology and evapotranspiration on streamflow recession characteristics in the Neversink Reservoir Watershed, New York

Estimates of dynamic groundwater volumes supplying baseflow to streams are important for water availability projections during extended periods of drought. The primary goals of this study were to provide dynamic storage volume estimates, inferred from streamflow recession analysis, for baseflow regimes within seven gaged catchments within the Neversink Reservoir Watershed (NRW), a critical municipal water source for New York City. Additionally, geomorphological properties, surficial geology and hydro-meteorological processes were quantified and described in relation to time and spatially variable recession behaviour and storage estimates across the NRW. To explore these relationships, we (1) evaluated seasonal trends in streamflow recession behaviour in relation to modelled potential evapotranspiration (PET) and catchment runoff rates, (2) derived empirical streamflow models for cool-season runoff using both linear and nonlinear reservoir assumptions for baseflow and (3) calculated metrics related to the geology and geomorphology of each catchment and compared these metrics to area normalised baseflow dynamic storage estimates. Results show that baseflow recession behaves as a nonlinear reservoir, and applying linear groundwater reservoir assumptions may underestimate the total dynamic storage volumes compared to what would be predicted for a nonlinear reservoir. Increases in PET caused decreases in storage conditions that resulted in increased recession rates and nonlinearity in streamflow recession during the growing season. Additionally, we found that while no single physical catchment characteristic solely predicted catchment storage dynamics, sediment volume and stream gradients were stronger predictors of normalised storage volumes than catchment surface area or surface topography alone. Within the NRW, catchments with the highest sediment volume exhibited the lowest recession rates and higher dynamic storage volumes, while the smallest catchment, mostly devoid of sediment, had the fastest recession rate and lowest dynamic storage volume.

New York

Regional evaluation of evapotranspiration in the Everglades

Nine sites in the Florida Everglades were selected and instrumented for collection of data necessary for evapotranspiration-determination using the Bowen-ratio energy-budget method. The sites were selected to represent the sawgrass or cattail marshes, wet prairie, and open-water areas that constitute most of the natural Everglades system. At each site, measurements necessary for evapotranspiration (ET) calculation and modeling were automatically made and stored on-site at 15- or 30-minute intervals. Data collected included air temperature and humidity at two heights, wind speed and direction, incoming solar radiation, net solar radiation, water level and temperature, soil moisture content, soil temperature, soil heat flux, and rainfall. Data summarized in this report were collected from January 1996 through December 1997, and the development of site-specific and regional models of ET for this period is described. Latent heat flux is the energy flux density equivalent of the ET rate. Modified Priestley-Taylor models of latent heat flux as a function of selected independent variables were developed at each site. These models were used to fill in periods of missing latent heat flux measurement, and to develop regional models of the entire Everglades region. The regional models may be used to estimate ET in wet prairie, sawgrass or cattail marsh, and open-water portions of the natural Everglades system. The models are not applicable to forested areas or to the brackish areas adjacent to Florida Bay. Two types of regional models were developed. One type of model uses measurements of available energy at a site, together with incoming solar energy and water depth, to estimate hourly ET. This available-energy model requires site data for net radiation, water heat storage, and soil heat flux, as well as data for incoming solar radiation and water depth. The other type of model requires only incoming solar energy, air temperature, and water depth data to provide estimates of hourly ET. The second model thus uses data that are more readily available than the data required for the available-energy model. Computed ET mean annual totals for all nine sites for the 1996-97 period ranged from 42.4 inches per year at a site where the water level is below land surface for several months each year to 57.4 inches per year at an open-water site with no emergent vegetation. Although the density of photosynthetically-active plant leaves has been shown to relate directly to ET in some studies, it does not appear to relate directly to ET in the Everglades, based on comparison of annual ET data with leaf-area index, defined as the Normalized Difference Vegetation Index (NDVI), data from satellite imagery. NDVI and ET appear to be inversely related in the Everglades. The greatest ET rates occurred at open-water sites where the NDVI data indicated the lowest leaf-area index. Among the remaining vegetated sites, there is no clear relation between ET and NDVI, though the highest ET rate corresponded to the lowest NDVI and one of the lowest ET rates corresponded to the highest NDVI value. The variation in ET follows a seasonal pattern, with lowest monthly ET totals occurring in December through February, and highest ET occurring in May through August. The greatest range in monthly ET among all nine sites for the 2-year period occurred at site 3: from 1.81 inches in December 1997 to 6.84 inches in July 1996. A study to compare the Bowen-ratio/energy balance method of ET measurement with the eddy-correlation method was done at one site from June 22, 1998, through September 28, 1998. This comparison indicated that both methods gave comparable values of the Bowen ratio, but there was a considerable difference in available energy measured by the two methods. The mean of all 30-minute measured turbulent heat fluxes from the eddy-correlation apparatus for June 22 through September 29, 1998, was 137.4 watts per square meter, and the mean of the corresponding measured energy was 163.6 watts per square meter, or about 20 percent greater. The disagreement in mean energy fluxes measured by the two methods is problematical and is not fully understood. Although the difference seems to be related to friction velocity, and is practically non-existent at values of friction velocity greater than 0.3 meter per second, the "correctness" of either method cannot be determined with the data available.

Florida

A 700-year rupture sequence of great eastern Aleutian earthquakes from tsunami modeling of stratigraphic records

Great Aleutian underthrusting earthquakes produced destructive tsunamis impacting Hawaiʻi in 1946 and 1957. Prior modeling of the 1957 tsunami deposit and runup records on eastern Aleutian and Hawaiian Islands jointly with tide-gauge observations across the Pacific Ocean constrained a rupture model with shallow slip up to 26 m along 600 km of the plate boundary. Here we implement this modeling approach to older deposits and show alternating deep and shallow megathrust slip up to 26, 32, and 22 m for great earthquakes along the same segment in the 18 th , 15 th , and 14 th centuries. All three modeled prehistoric Aleutian earthquakes produce tsunami inundation in Hawaiʻi with the most severe, 14 th century event having impacts exceeding the 1957 event. The along-dip variability of these four ruptures spanning seven centuries provides insights on earthquake cycles for engineering design and hazard assessment. The 15 th century and 1957 rupture models provide evidence for recurrence of tsunami earthquakes, which can produce disproportionately large tsunamis for a given moment magnitude due to reduced rigidity in the shallow megathrust. The 14 th and 18 th century events likely ruptured deeper regions that did not slip in 1957, suggesting potential for corresponding deeper failure in the next great eastern Aleutian earthquake.

Alaska, Hawaii