USGS ScienceSearch

SEARCH · USGS Science

Results for “Frontiers in Environmental Science”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,607 records · Page 32Linked to original sources

Relationship between peak and cumulative ground motions from 49 Mw 3-6 earthquakes in the San Francisco Bay Area

We examine the relationship between peak ground velocity (PGV) and cumulative absolute displacement (CAD) for 49 M w 3 – 6 earthquakes in the San Francisco Bay Area (SFBA) and gain insight into the spatiotemporal partitioning of seismic energy in ground motion records with respect to source, path, and site effects. PGV and CAD are positively correlated, but there can be large deviations from the average trend. For example, ground motion records with either very long duration resonance or short pulse-like motions will have higher or lower CAD, respectively, but could have very similar PGV. We perform principal component analysis (PCA) on PGV-CAD for >7000 records in the SFBA with the goal of investigating what influences positive or negative anomalies in cumulative motions. PCA rotates the PGV-CAD datapoints into two principal components, where the one with the larger variance, which we call the “primary intensity” represents mostly the distance-dependence of ground motion amplitudes. The other principal component, which we call the “excess motion”, represents the deviation from cumulative motions that would be typical for a ground motion record with a given PGV. The excess motion will be positive in the case of records with long duration ringing and will be negative for short duration pulse-like ground motions. We find that excess motion is generally positive at sites in sedimentary basins and in soft sediments around the SF Bay. Excess motion is generally negative in the very near field, as well as at sites on hard bedrock. We discuss the findings here in terms of implications for seismic hazard applications and other wave propagation phenomena.

California

Petrography and mineralogy of selected pre-Middle Jurassic basement rocks beneath the Atlantic and Gulf Coastal Plains in Florida

Florida is covered by flat-lying sedimentary strata of the Atlantic and Gulf Coastal Plains. These strata have accumulated since Middle Jurassic time. The pre-Middle Jurassic, or basement, rocks that underlie the Coastal Plain in Florida are known only from drill cores and cuttings recovered from a relatively small number of boreholes. This data report presents petrographic observations and the results of X-ray diffraction analyses of basement rocks from 18 boreholes across Florida in support of the identification, discrimination, and correlation of units for a subcrop geologic map of pre-Middle Jurassic rocks composing Florida’s sub-Coastal Plain geology.

Florida

Examining the role of elevated and sustained strain in dynamically triggering earthquakes on the Anza section of the San Jacinto fault

Microearthquakes can be dynamically triggered in southern California by remote earthquakes. However, directly connecting dynamic triggering mechanisms with observational data remains challenging. One proposed failure mechanism suggests that both the amplitude and duration of cyclic fatigue caused by the passing seismic wave contribute to triggering occurrence. Here, we measure dynamic strains recorded by borehole strainmeters in the Anza section of the San Jacinto fault zone from 710 earthquakes that occurred over 300 km away between 2008 and 2017 to systematically investigate the role of elevated and sustained strain in controlling dynamic triggering. We design a suite of tests to evaluate whether specific amplitude thresholds and durations of strain can predict dynamic triggering cases. We further test whether the peak dynamic strain (PDS) can predict triggering occurrence in combination with the strain amplitude and duration. Based on these tests, there is no strain amplitude–duration threshold that can distinguish triggering occurrence in Anza. Dynamic triggering is more likely to occur if a remote earthquake causes a PDS above 100 nanostrain, though many cases were triggered at smaller PDSs. The lack of clear correlation between triggering and characteristics of the dynamic strain field suggests that the tested features of the incoming waves do not determine triggering occurrence and local fault conditions and slip processes are more important in controlling dynamic triggering in Anza.

California

Chemical evolution and estimated flow velocity of water in the Trinity Aquifer, south-central Texas

Three permeable zones with varying lithology and water chemistry compose the Trinity aquifer, a principal source of water in the 5,500- square-mile study area in south-central Texas. The upper permeable zone locally yields small quantities of water to wells and was not included in this study. The middle permeable zone primarily is composed of limestone with minor amounts of dolostone. Terrigenous sand and marine limestone, with minor amounts of dolostone, are the principal lithologic units in the lower permeable zone. Dissolved solids concentrations range from 329 to 1,820 milligrams per liter in water samples from the middle permeable zone and from 518 to 3,030 milligrams per liter in water samples from the lower permeable zone. Principal hydrochemical facies in the middle permeable zone are calcium magnesium bicarbonate and calcium magnesium sulfate. Hydrochemical facies in ground-water samples from the lower permeable zone vary. Tritium concentrations as large as 5.3 tritium units in the southeastern part of the study area are indicative of relatively recent recharge. Results of a geochemical mass balance simulation along a flowpath in the middle permeable zone indicate a mass transfer of 4.25 millimoles per liter of dolomite dissolved, 5.74 millimoles per liter of gypsum dissolved, 0.46 millimole per liter of sodium chloride dissolved, 8.07 millimoles per liter of calcite precipitated, and 0.67 millimole per liter of calcium-for-sodium cation exchange between solid and aqueous phases. These results support dedolomitization as a principal chemical process in the middle permeable zone of the Trinity aquifer. Results of a simulation along a flowpath in the lower permeable zone indicate a mass transfer of 0.41 millimole per liter of dolomite dissolved, 0.001 millimole per liter of gypsum dissolved, 9.58 millimoles per liter of sodium chloride dissolved, 1.09 millimoles per liter of calcite precipitated, and 1.11 millimoles per liter of sodium-forcalcium cation exchange between solid and aqueous phases. Lower permeable zone processes indicate sodium chloride dissolution, dedolomitization, and cation exchange. Ground-water-flow velocities determined from adjusted carbon-14 ages, calculated using NETPATH, for selected flowpaths in the middle and lower permeable zones were about 1.7 feet per year and less than about 4.4 feet per year, respectively.

Texas

Detailed investigation of a coastal plain-Piedmont fault contact in northeastern Virginia

A trench across the Dumfries fault of the Stafford fault zone near Stafford, Virginia (see Mixon and Newell, 1976) exposed a high-angle reverse fault juxtaposing Paleozoic Quantico Slate and Cretaceous Potomac Group rocks. A system of subsidiary reverse faults and small scale normal faults disrupt the Coastal Plain strata adjacent to the main fault. Cross-cutting relations and stratigraphic details indicate that the subsidiary faults in the Cretaceous rocks document a history of episodic deformation, in part active during accumulation of the Coastal Plain strata. Slickensides and stereo net analysis of theorientation of subsidiary reverse faults, normal faults, and bedding indicate that, through time, faulting consistently included right lateral separation.

Virginia

Groundwater quality and groundwater levels in Dougherty County, Georgia, April 2020 through January 2023

The Upper Floridan aquifer is the uppermost reliable groundwater source in southwest Georgia. The aquifer lies on top of the Claiborne, Clayton, and Cretaceous aquifers, all of which exhibited water-level declines in the 1960s and 1970s. The U.S. Geological Survey has been working cooperatively with Albany Utilities to monitor groundwater quality and availability in these aquifers since 1977. Flow direction in the Upper Floridan aquifer is to the south and toward the Flint River. During the past 3 years, water levels varied above and below period-of-record median values. Water levels in the Upper Floridan aquifer were primarily above or at median levels during 2020 and 2021 and at or below median levels during 2022. Water levels in the Claiborne aquifer were above median levels, whereas water levels in the Clayton aquifer were at or below median levels, and in the Cretaceous aquifer system were close to median levels. During January 2021, eight wells were sampled for major ions, including nitrate plus nitrite as nitrogen (N). Nitrate plus nitrite as N concentrations ranged from 2.3 to 10.5 milligrams per liter (mg/L). During December 2021, seven wells were sampled for major ions, including nitrate plus nitrite as N. Nitrate plus nitrite as N concentrations ranged from 3.9 to 9.9 mg/L. During November 2022, eight wells were sampled for major ions, including nitrate plus nitrite as N. Nitrate plus nitrite as N concentrations ranged from 3.9 to 10.0 mg/L. Two wells were also sampled for per- and polyfluoroalkyl substances during November 2022.

Georgia

Analyzing spatial distributions and alignments of pitted cone features in Utopia Planitia on Mars

Martian geomorphology and surface features provide links to understanding past geologic processes such as fluid movement, local and regional tectonics, and feature formation mechanisms. Pitted cones are common features in the northern plains basins of Mars. They have been proposed to have formed from upwelling volatile-rich fluids, such as magma or water-sediment slurries. In this study, we map the spatial distributions of pitted cone features across the Utopia Planitia (UP) basin. Using the Average Nearest Neighbor technique, we find that pitted cone features appear to be clustered across the basin, occurring in a narrow band around the circumferential rim of UP. Additionally, we find that pitted cone features also appear to be aligned in chains that are sub-parallel with the basin margin. Parallel bands of cones generally follow elevation contours of the UP basin, which suggests elevation or a correlated factor plays a major role in pitted cone and cone chain formation. We propose that pitted cones and cone chains may be related to vertical fractures formed around the UP basin rim from subsidence of infilling basin material.

Icarus

Insights into widespread landsliding in southern Appalachia from Hurricane Helene

Between 23 and 27 September 2024, antecedent rain followed by Hurricane Helene produced one of the most damaging weather events in southern Appalachia history. The back-to-back storm events resulted in a maximum cumulative rainfall of 848 mm and hurricane-force wind gusts over 170 km/h in western North Carolina, eastern Tennessee, and southwestern Virginia. The resulting regional flooding, landslides, and tree blowdown caused over 100 fatalities, damaged or destroyed critical infrastructure and thousands of structures, and severed connectivity across the region. Over the next several weeks, a multi-agency landslide response produced a rapid hazard assessment and mapped 2217 landslides, 55% of which damaged infrastructure or property. Orographic uplift enhanced rainfall, resulting in concentrated landsliding along the ~250 km swath of the Blue Ridge escarpment in western North Carolina. Landslides initiated predominantly on windward-facing (southeast-facing) slopes, and localized clustering of initiation points indicated a strong influence of hillslope-scale meteorological and geomorphic factors. Many shallow landslides mobilized into larger, highly mobile, and damaging debris flows that graded into floods. Here, we put our preliminary observations in the context of historical storm-driven landslide events and open new avenues for investigating the nature and extent of landslides and their effects in southern Appalachia and similar environments.

Georgia, North Carolina, South Carolina, Tennessee

Hydrologic response of groundwater and streamflow to natural and anthropogenic drivers of change in headwaters of the upper Colorado River basin during recent wet (1982–1999) and drought (2000–2022) conditions

Study region: Headwaters of the upper Colorado River basin (UCOL), USA Study focus: Surface-water and groundwater numerical models incorporating water-use information were used to investigate changes in climate, water use, and simulated hydrologic responses of snow processes, evapotranspiration, groundwater, and streamflow during recent wet (1982–1999) and drought (2000–2022) periods in the headwater subregions of the upper Colorado River basin. New hydrologic insights for the region: Decreases in average streamflow between wet and drought periods ranged from 20 % in the Colorado River headwaters subregion to 23 % in the Gunnison River headwaters subregion. Like streamflow, average surface runoff was statistically less during the drought than the wet period, with decreases from 24–31 % in the headwaters. On a volume basis, runoff decreases were greater than streamflow decreases in both the Colorado River and Gunnison River headwaters. Although the amount of water-year groundwater discharge to streams remained nearly the same between the wet and drought periods, groundwater as a percentage of streamflow increased between the wet and drought periods, highlighting the importance of groundwater in sustaining streamflow during drought conditions. Multiple linear regression analyses revealed that snowmelt-only models were better than the best precipitation and temperature models at explaining streamflow variability from all headwater subregions for both the wet and drought periods.

Arizona, Colorado, New Mexico, Utah, Wyoming

Postglacial ecosystem development of a hydrothermal landscape in Yellowstone National Park

The Yellowstone geo-ecosystem has been the subject of much research, but the ecological history of the Yellowstone Plateau volcanic field and its iconic geyser basins is less known. In this investigation, paleoenvironmental analyses of sediment cores from lakes in Lower Geyser Basin were compared with regional records and paleoclimate model simulations to reconstruct the vegetation, wildfire, limnology, hydrothermal dynamics, and climate drivers since deglaciation, 15,000 to 14,000 years ago. Pollen data from Lower Geyser Basin lakes reveal the strong influence of infertile rhyolitic soils on vegetation history: an initial late-glacial steppe was replaced by lodgepole pine forest from 12.8 to 11.0 ka, with little change in forest composition or cover thereafter despite changing climate. This stability contrasts with the more dynamic vegetation response on nonrhyolite substrates in the Yellowstone region where nutrient and moisture availability is greater. Highest wildfire activity and low lake nutrient levels in Lower Geyser Basin occurred from 12 to 4 ka, when summers were substantially warmer and drier and fire-inducing vapor pressure deficits were 29 to 56% higher. The hydrothermal history, inferred from sedimentary arsenic and cesium abundances, was spatially and temporally variable but lake-forming hydrothermal events align with periods of abundant moisture. Thus, long-term changes in wildfire, limnology, and, to some extent, hydrothermal activity were governed by insolation-driven climate variations, whereas the vegetation response was muted and constrained by geologic processes. These findings suggest that warmer, drier conditions in the future could result in less hydrothermal activity yet little change in forest cover across the Yellowstone Plateau volcanic field despite more wildfires.

Idaho, Montana, Wyoming

A comparison of electronic particle counting and pipette techniques in routine mud analysis

Electronic particle counting and pipette size-analysis techniques are compared for their relative effectiveness in large-scale routine mud analysis. Optimum laboratory procedures for conducting electronic analyses with a Model TA Coulter Counter are presented. Comparative electronic and pipette analyses conducted on the same samples resulted in equivalent precision for both techniques. Results of electronic analyses consistently showed size distributions significantly coarser than those obtained by pipette analyses. The laboratory efficiency of the relatively rapid electronic technique is far superior to that of the pipette technique, although more extensive precautionary measures are required to maintain a high level of analytical accuracy and precision. The quality of electronic analyses largely depends upon the effectiveness of standardized operational procedures established within the laboratory.

Open-File Report

Simulation of the impacts of spring diversions on streamflow in the Strawberry Creek watershed, San Bernardino County, California, using an integrated hydrological model

The Strawberry Creek watershed, in the San Bernardino Mountains of southern California, features a group of natural springs known as Arrowhead Springs that have been augmented with diversions in the form of sub-horizontal borings and tunnels. Understanding the effects of these structures on streamflow through groundwater capture is crucial for managing surface-water resources in this watershed. In this study, we constructed the Strawberry Creek integrated hydrological model to increase this understanding. The Strawberry Creek integrated hydrological model is an integrated surface runoff and groundwater model, GSFLOW to simulate surface runoff and infiltration and groundwater flow. The model has 263 rows and 176 columns in each of its three layers. The model area includes the Strawberry Creek and four adjacent watersheds. The precipitation-runoff modeling system was calibrated using two streamflow gaging stations, and the groundwater and surface-water flow model was calibrated to the reported spring diversion discharge and a sparse number of groundwater-level measurements. The Strawberry Creek integrated hydrological model was run with and without diversions active, and simulated streamflow was compared, indicating that in the headwaters of Strawberry Creek, about 35 percent of the diversion flow was captured from base flow.

California

Assessment of the interconnection between Tampa Bay and the Floridan aquifer system: Historical groundwater data compilation and analysis, 1976–2022

The U.S. Geological Survey used existing data collected after the last major navigational channel modification in the mid-1980s to investigate groundwater levels and chloride concentrations in wells in the Floridan aquifer system and other aquifers beneath and near Tampa Bay. Tampa Bay is located on the west-central coast of Florida and provides access for commercial shipping. In 2021, the U.S. Army Corps of Engineers began to investigate alternatives to improve the efficiency of the deep-draft navigation channels within Tampa Bay, reduce costs, improve safety, and analyze the implications of modifying navigational channels. The Floridan aquifer system underlies Tampa Bay and is the primary source of public water supply in the region. Modifications to the channels have the potential to expose the Floridan aquifer system to the saltwater in Tampa Bay, with the potential to increase salinity in wells in the region. Other factors affecting the groundwater levels and the location of the freshwater/saltwater interface were also examined, including changes in sea level, groundwater extraction, and variations in climate. Groundwater levels and well-construction reports were used to identify whether different aquifer units are well-connected. Twelve wells had available data before and after the last major channel modifications, which took place in the 1980s, with six datasets of chloride concentration available in areas along the northern and eastern coastline of Tampa Bay, which is nearest to historical dredging activities. Of these six, Kendall’s τ and p -values indicated increasing trends in chloride concentration for three datasets (TR 11-2, TR 10-2, 51), no trend in chloride concentration for two datasets (TR 9-3, 50), and a decreasing trend in chloride concentration for one dataset (TR 9-1). The upward trends in chloride concentration observed for TR 10-2 and 51 are likely the result of changes in local groundwater withdrawals. Well TR 11-2 had a gradual increasing trend in chloride concentration, fresh groundwater throughout the period of record, and a 3- to 4-foot increase in hydraulic head during the period of record, possibly caused by the construction and control of the Tampa Bypass Canal, resulting in changes to the regional potentiometric surface.

Florida

Assessing legacy nitrogen in groundwater using numerical models of the Long Island aquifer system, New York

Nitrogen transported along groundwater flow paths in coastal aquifers can contribute substantially to nitrogen loading into surface water receptors, particularly in hydrologic systems dominated by groundwater discharge. Nitrogen entrained in the aquifer is a function of land use and associated nitrogen sources at the time of groundwater recharge, which may differ considerably from present-day sources. Legacy nitrogen can result in substantial discrepancies between observed present-day nitrogen loading to surface water receptors and loading estimated from present-day sources. Additionally, legacy nitrogen can continue to discharge into surface waters after nitrogen mitigation actions have been undertaken. Here, we use a numerical modeling framework to compare three methods of estimating time-varying historical nitrogen loads to four water bodies (receptors) on eastern Long Island, New York. The methods span a range of data requirements and process complexity, from instantaneous receptor loads calculated from steady-state groundwater contributing areas, to transient loads estimated by explicitly simulating legacy groundwater nitrogen transport over a century with large changes in nitrogen sources and hydrologic conditions. The effects of legacy nitrogen on estimated receptor loads varied temporally and spatially within the study area. Depending on antecedent nitrogen inputs and hydrologic conditions, historical annual nitrogen loads estimated from transient simulations accounting for legacy nitrogen can be quite similar (<10% difference) or substantially different (±100%) from those estimated from simpler instantaneous methods. Continued input of present-day nitrogen sources using methods that account for legacy nitrogen results in asymptotic increases in receptor nitrogen loads over time, indicating that simulated present-day receptor nitrogen loads are not in equilibrium with present-day inputs. For these receptors in disequilibrium, models simulating transient groundwater nitrogen transport could be used to account for legacy nitrogen lag times to help resource managers evaluate the potential effectiveness of proposed nitrogen mitigation actions.

EarthArXiv

Ground-water quality near an inactive landfill and sludge-spreading area, Tallahassee, Florida

Ground-water quality of a 120-acre area encompassing an inactive landfill southwest of Tallahassee, Florida, was assessed by installing and sampling 21 monitoring wells. Sludge from a municipal sewage-treatment plant was also applied to the land surface near the landfill site. Water samples were collected from the 21 monitoring wells from June 1987 through September 1990 and analyzed for concentrations of major ions, nitrogen species, trace metals, field measurements, and more than 140 organic constituents. Water quality in the Upper Floridan aquifer at the study site was compared to background water quality in other areas of Leon County. Ground-water quality of the study site was evaluated by the location of wells sampled in relation to the landfill and the sludge-spreading areas. Results of nonparametric statistical analysis indicated that potassium and nitrite plus nitrate as nitrogen concentrations in water samples from wells completed in the Upper Floridan aquifer at the study site were significantly different at the 5 percent probability level from those in samples from background wells completed in this aquifer in Leon County. Median potassium concentrations were 0.4 mg/L (milligrams per liter) in water from wells at the study site and 0.7 mg/L in water from background wells in Leon County. Median nitrite plus nitrate concentrations were 6.48 mg/L in water samples from wells at the study site and 0.51 mg/L in water samples from background wells. Graphical comparison of the water quality characteristics in water from six categories of wells; upgradient, landfill, adjacent to the landfill, downgradient onsite, downgradient offsite, and background Leon County, indicated that sodium, bicarbonate, sulfate, iron, manganese, and dissolved solids concentrations and specific conductance values were highest within the landfill. Upgradient and downgradient well categories include wells in areas affected by sludge spreading. Localized reducing conditions were indicated in a downgradient area by median iron concentrations of 930 and 30 ug/L (micrograms per liter) in samples from wells only 5 feet apart. Nitrite plus nitrate concentrations were lowest in water from wells in the landfill compared to water from the other categories. Concentrations of most trace elements and organic compounds were mostly below detection limits, although State maximum contaminant levels of 1 ug/L for benzene and vinyl chloride and 3 ug/L for tetrachloroethene were exceeded in 14 samples. Concentrations of sodium, potassium, chloride, sulfate, nitrite plus nitrate, total organic and ammonia nitrogen, and ammonia nitrogen in ground water were statistically analyzed in areas affected by sludge-spreading and other areas. Only nitrite plus nitrate and chloride concentrations were significantly different between the two areas. Median nitrite plus nitrate and chloride concentrations in sludge-spreading areas were 6.9 mg/L and 2.9 mg/L, respectively, compared to 1.1 mg/L and 1.8 mg/L in other areas.

Florida

Transmissivity and water quality of water-producing zones in the intermediate aquifer system, Sarasota County, Florida

The intermediate aquifer system is an important water source in Sarasota County, Florida, because the quality of water in it is usually better than that in the underlying Upper Floridan aquifer. The intermediate aquifer system consists of a group of up to three water-producing zones separated by less-permeable units that restrict the vertical movement of ground water between zones. The diverse lithology, that makes up the intermediate aquifer system, reflects the variety of depositional environments that occurred during the late Oligocene and Miocene epochs. Slight changes in the depositional environment resulted in aquifer heterogeneity, creating both localized connection between water-producing zones and abrupt culmination of water-producing zones that are not well documented. Aquifer heterogeneity results in vertical and areal variability in hydraulic and water-quality properties. The uppermost water-producing zone is designated producing zone 1 but is not extensively used because of its limited production capability and limited areal extent. The second water-producing zone is designated producing zone 2, and most of the domestic- and irrigation-supply wells in the area are open to this zone. Additionally, producing zone 2 is utilized for public supply in southern coastal areas of Sarasota County. Producing zone 3 is the lowermost and most productive water-producing zone in the intermediate aquifer system. Public-supply well fields serving the cities of Sarasota and Venice, as well as the Plantation and Mabry Carlton Reserve well fields, utilize producing zone 3. Heads within the intermediate aquifer system generally increase with aquifer depth. However, localized head-gradient reversals occur in the study area, coinciding with sites of intense ground-water withdrawals. Heads in producing zones 1, 2, and 3 range from 1 to 23, 0.2 to 34, and 7 to 42 feet above sea level, respectively. Generally, an upward head gradient exists between producing zones 3 and 2. However, an upward head gradient between producing zones 2 and 1 does not consistently occur throughout Sarasota County, probably the result of greater ground-water withdrawals from producing zone 2 than from producing zone 1. The transmissivity of the intermediate aquifer system is spatially variable. Specific-capacity data from selected wells penetrating producing zones 2 and 3, were used to estimate transmissivity. Estimated transmissivity values for producing zones 2 and 3 range from about 100 to 26,000 feet squared per day and from about 1,300 to 6,200 feet squared per day, respectively. Because the capacity of specific water-producing zones is highly variable from site to site, estimating the performance of a specific water-producing zone as a water resource is difficult. Water samples collected during the study were analyzed for major-ion concentrations. Generally, bicarbonate type water from rock interaction occurs in northern Sarasota County; enriched calcium-magnesium-sulfate type water from deeper aquifers occurs in central Sarasota County; and sodium-chloride type water from saltwater mixing occurs in southern Sarasota County. In some areas of northern Sarasota County, the major-ion concentrations in water are lower in producing zone 2 than in producing zone 1. Major-ion concentrations in water are higher in producing zone 3 throughout the study area. A major objective of the study was to evaluate hydraulic and water-quality data to determine distinctions that could be used to characterize a particular producing zone. However, data indicate that both hydraulic and water-quality properties are highly variable within and between zones, and are more related to the degree of connection between and areal extent of water-producing zones than to aquifer depth and distance from the coast.

Florida

Thermo-hydrologic processes governing supra-permafrost talik dynamics in discontinuous permafrost near Umiujaq (Québec, Canada)

Widespread supra-permafrost talik formation is currently recognized as a critical mechanism that could accelerate permafrost thaw in the Arctic (e.g., Connon et al. 2018; Farquharson et al. 2022). However, the trajectory of permafrost dynamics following talik formation may prove difficult to predict. Physically-based cryohydrogeologic models provide a powerful tool for understanding processes and factors controlling talik dynamics and, ultimately, how permafrost will respond to climate change. Such models are typically used to represent multiple non-linear processes relevant for groundwater systems in cold regions, such as coupled heat and groundwater movement, including freeze-thaw dynamics and the effects on the surface energy balance and the subsurface thermal and hydraulic properties (Lamontagne-Hallé et al. 2020). Though cryohydrogeologic modeling advances have been made in simulating talik dynamics, few applications have been tested against robust long-term hydrometeorological and subsurface observations.

Quebec

Methods for estimating selected low-flow statistics at gaged and ungaged stream sites in Massachusetts

The U.S. Geological Survey, in cooperation with the Massachusetts Department of Conservation and Recreation, Office of Water Resources, computed selected at-site streamflow statistics at U.S. Geological Survey streamgages in and near Massachusetts and developed regional regression equations for estimating selected streamflows at ungaged stream sites in Massachusetts. Two sets of regional regression equations were developed: (1) the “mainland” equations, for mainland Massachusetts excluding the area covered by the second set, and (2) the “southeastern” equations, for the Plymouth-Carver-Kingston-Duxbury aquifer area in southeastern Massachusetts and for Cape Cod. The regression equations and at-site statistics may be used by Federal, State, and local water managers in addressing water-resources issues relevant in Massachusetts. Regional regression analyses for the mainland equations were developed to estimate the following 27 streamflow statistics: 99-, 98-, 95-, 90-, 85-, 80-, 75-, 70-, 60-, and 50-percent flow durations; monthly June, July, August, and September 90- and 50-percent flow durations; February, June, and August median of the monthly means; harmonic mean; and medians of the following annual low-flow frequency statistics: 7-day; 7-day, 2-year; 7-day, 10-year; 30-day, 2-year; and 30-day, 10-year. The analyses used 81 streamgages with minimal to no regulations in and near Massachusetts. The regression analyses determined that four basin characteristics—drainage area, combined hydrologic soils A and B, streamflow variability index, and annual mean temperature—were the only significant explanatory variables for the different mainland equations. Regional regression equations were developed for the Plymouth-Carver-Kingston-Duxbury aquifer area in southeastern Massachusetts and Cape Cod, because surface-water drainage areas and groundwater contributing areas do not always coincide in this area of the State. The regression analyses to estimate 10 flow durations from the 99th to 50th percentiles used 18 streamflow sites with some occasional minor regulations—because there are few unregulated streams in southeastern Massachusetts. The analyses determined that groundwater contributing area and storage (combined water bodies and wetlands) were the only significant explanatory variables in the southeastern equations.

Massachusetts