USGS Science⌕ Search

SEARCH · USGS Science

Results for “Geothermics”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Source processes of industrially-induced earthquakes at the Geysers geothermal area, California

Microearthquake activity at The Geysers geothermal area, California, mirrors the steam production rate, suggesting that the earthquakes are industrially induced. A 15-station network of digital, three-component seismic stations was operated for one month in 1991, and 3,900 earthquakes were recorded. Highly-accurate moment tensors were derived for 30 of the best recorded earthquakes by tracing rays through tomographically derived 3-D VP and VP / VS structures, and inverting P-and S-wave polarities and amplitude ratios. The orientations of the P-and T-axes are very scattered, suggesting that there is no strong, systematic deviatoric stress field in the reservoir, which could explain why the earthquakes are not large. Most of the events had significant non-double-couple (non-DC) components in their source mechanisms with volumetric components up to ???30% of the total moment. Explosive and implosive sources were observed in approximately equal numbers, and must be caused by cavity creation (or expansion) and collapse. It is likely that there is a causal relationship between these processes and fluid reinjection and steam withdrawal. Compensated linear vector dipole (CLVD) components were up to 100% of the deviatoric component. Combinations of opening cracks and shear faults cannot explain all the observations, and rapid fluid flow may also be involved. The pattern of non-DC failure at The Geysers contrasts with that of the Hengill-Grensdalur area in Iceland, a largely unexploited water-dominated field in an extensional stress regime. These differences are poorly understood but may be linked to the contrasting regional stress regimes and the industrial exploitation at The Geysers.

Geophysics↗

Reservoir controling factors in the Karaha-Telaga Bodas geothermal field, Indonesia

Karaha - Telaga Bodas geothermal system consists of: 1) a caprock, ranging from several hundred meters to 1600 m thick that is characterized by steep, conductive temperature gradients and low permeabilities; 2) an underlying vapor-dominated zone that extends below sea level; and 3) a deep liquid-dominated zone with measured temperatures up to 353??C. Heat is provided by a 3 km deep tabular granodiorite stock. The effective base of the reservoir is controlled by the stress regime's effect on fractures within volcanic rocks located above the brittle/ductile deformation boundary. The base of the caprock is controlled by the distribution of initially low-permeability lithologies above the reservoir; the extent of pervasive clay alteration that has reduced initial permeabilities; the distribution of secondary minerals deposited by descending waters; and by a downward change from a strike-slip to an extensional stress regime. Producing zones are controlled by both matrix and fracture permeabilities.

Conference Paper↗

Gravity and magnetic studies of the Geysers-Clear Lake geothermal region, California, USA

Gravity and magnetic fields in The Geysers-Clear Lake region are interpreted in relation to the known geology and other available geophysical data. New gravity data provide additional detail with the area of geothermal steam production. Computer techniques were used for removal of the regional gravity field, anomaly enhancement, and modeling subsurface structures. The gravity field was separated into three components: (1) a regional field presumed to be due to deep crustal structure related to the continental margin; (2) a residual gravity low of approximately 30 mgal centered over Mount Hannah and having an approximate diameter of 20 km, which is caused, according to our model, by a magma chamber whose top lies within 10 km of the surface; and (3) a closed residual low over the original steam production field. This low is probably related to effects within 1.5 km of the surface and was modeled as a steam-saturated reservoir structure. Local magnetic highs correlate with surface outcrops of serpentinite and relief on the volcanic rocks. Upward continuation of the aeromagnetic data suggests that the serpentinite body along the Collayomi fault may extend to a depth of more than 3 km near Boggs Mountain, but that other serpentinite bodies are probably more shallow. A long-wavelength magnetic high (centered at ~39°03'N 122°33'W) and a magnetic low (centered at ~38&deg:43'N 122°47'W) give half-width depth estimates of about 10 km. The center of the Mount Hannah gravity low lies in an area between these features and appears devoid of deep magnetic expression.

California↗

Delineation of fractures, foliation, and groundwater of the bedrock at a geothermal feasibility site on Roosevelt Island, New York County, New York

Advanced borehole-geophysical methods were used to investigate the hydrogeology of the crystalline bedrock in three boreholes on Roosevelt Island, New York County, New York. Cornell University was evaluating the feasibility of using geothermal energy for a future campus at the site. The borehole-logging techniques were used to delineate bedrock fractures, foliation, and groundwater-flow zones of the Fordham Gneiss in test boreholes at the site. Three fracture populations dominated by small (0.04 in or less) fractures were delineated in the three boreholes. A sub-horizontal population with low to moderate dipping fractures, a northeast dipping population with moderate to high angle fractures, and a small northwest dipping high angle fracture population. One large southwest dipping transmissive fracture underlies the entire study area with a mean dip azimuth of 235º southwest and a dip angle of 31º (N325ºW 31ºSW). The mean foliation dip azimuth was 296º northwest with a mean dip angle of 73º (N26ºE 73ºNW). Groundwater appears to flow through a network of fractures dominated by a large fracture underlying the site that is affected by tidal variations from the nearby East River. The total number of fractures penetrated by each borehole was 95, 63, and 68, with fracture indices of 0.26, 0.20, and 0.20 in GT-1 (NY292), GT-2 (NY293), and GT-3 (NY294), respectively. Aquifer test data indicate the specific capacity of boreholes GT-1 (NY292), GT-2 (NY293), and GT-3 (NY294) was 1.9, 1.5, and 3.7 gal/min/ft, respectively. The large contribution of flow from the leaking casing in borehole GT-3 (NY294) caused the doubling in specific capacity compared to boreholes GT-1 (NY292) and GT-2 (NY293). The transmissivities of the large fracture intersected by the three boreholes tested (GT-1, GT-2, and GT-3), calculated from aquifer-test analyses of time-drawdown data and flowmeter differencing, were 133, 124, and 65 feet squared per day (ft2/d), respectively. Gringarten analysis indicated the large fracture intersects a low transmissivity boundary or distant fracture network with an average transmissivity of 69 ft2/d, this distant hydraulic boundary averages about 200 ft away from boreholes GT-1 and GT-2. Field measurements of specific conductance of the three boreholes under ambient conditions at the site indicate an increase in conductivity toward the southwest part of the site. Specific conductance was 5, 6, and 23 millisiemens per centimeter (mS/cm) in boreholes GT-2, GT-3, and GT-1, respectively. Three borehole radar reflection logs collected at each of the boreholes indicated increased penetration with depth and the large fracture intersecting all three boreholes was imaged as far as 80 ft from the boreholes. A borehole radar attenuation tomogram from GT-1 to GT-2 indicated the large fracture intersected by the boreholes extends between the boreholes with a low angle southwest dip.

New York↗

An approach to modeling coupled thermal-hydraulic-chemical processes in geothermal systems

Interactions between hydrothermal fluids and rock alter mineralogy, leading to the formation of secondary minerals and potentially significant physical and chemical property changes. Reactive transport simulations are essential for evaluating the coupled processes controlling the geochemical, thermal and hydrological evolution of geothermal systems. The objective of this preliminary investigation is to successfully replicate observations from a series of hydrothermal laboratory experiments [Morrow et al., 2001] using the code TOUGHREACT. The laboratory experiments carried out by Morrow et al. [2001] measure permeability reduction in fractured and intact Westerly granite due to high-temperature fluid flow through core samples. Initial permeability and temperature values used in our simulations reflect these experimental conditions and range from 6.13 × 10−20 to 1.5 × 10−17 m2 and 150 to 300 °C, respectively. The primary mineralogy of the model rock is plagioclase (40 vol.%), K-feldspar (20 vol.%), quartz (30 vol.%), and biotite (10 vol.%). The simulations are constrained by the requirement that permeability, relative mineral abundances, and fluid chemistry agree with experimental observations. In the models, the granite core samples are represented as one-dimensional reaction domains. We find that the mineral abundances, solute concentrations, and permeability evolutions predicted by the models are consistent with those observed in the experiments carried out by Morrow et al. [2001] only if the mineral reactive surface areas decrease with increasing clay mineral abundance. This modeling approach suggests the importance of explicitly incorporating changing mineral surface areas into reactive transport models.

Conference Paper↗

The calculation of aquifer chemistry in hot-water geothermal systems

The temperature and chemical conditions (pH, gas pressure, and ion activities) in a geothermal aquifer supplying a producing bore can be calculated from the enthalpy of the total fluid (liquid + vapor) produced and chemical analyses of water and steam separated and collected at known pressures. Alternatively, if a single water phase exists in the aquifer, the complete analysis (including gases) of a sample collected from the aquifer by a downhole sampler is sufficient to determine the aquifer chemistry without a measured value of the enthalpy. The assumptions made are that the fluid is produced from a single aquifer and is homogeneous in enthalpy and chemical composition. These calculations of aquifer chemistry involving large amounts of ancillary information and many iterations require computer methods. A computer program in PL-1 to perform these calculations is available from the National Technical Information Service as document PB-219 376.

Journal of Research of the U.S. Geological Survey↗

Recurrent geothermally induced debris avalanches on Boulder Glacier, Mount Baker, Washington

Avalanches of snow, firn and hydrothermally altered rock and mud have been released six times since 1958 from Sherman Peak, part of the crater rim south of the main summit of Mount Baker, Wash. The avalanches traveled nearly identical paths 2.0-2.6 km down Boulder Glacier on the east slope of the volcano. Debris from at least one past avalanche can be seen as a thin bed of acidic mud in the glacier terminus. Fumaroles. thermal springs, and areas of warm ground, some of which are subglacial, are concentrated in the crater and were mapped by aerial infrared thermography. The outgoing radiant flux per unit area from a cluster of infrared anomalies within 50-150 m of the avalanche source was estimated to be 319 W m -2 (7,620 μ cal cm -2 s -1 ) in November 1972, which is sufficient to account for observed ice perforations. In addition vapor emission, not apparent in thermography, was observed along the source margin after the avalanche of August 1973. The principal conditions that produce the avalanches are considered to be the large accumulation of snow and firn on top of hydrothermally altered clay-rich ground at Sherman Peak and the saturation near the ground-firn interface by melt water produced both by summer snow ablation and by geothermal emission. The periodic avalanches have a potential for impounding water in the crater in addition to ponded water already known to occur. Sudden release of impounded water could present a danger to the Boulder Creek valley below.

Washington↗

Pleistocene rhyolite of the Mineral Mountains, Utah: Geothermal and archeological significance

Little-eroded rhyolitic tuffs, flows, and domes extend over about 25 km 2 along the western side of the Mineral Mountains, southwestern Utah, which is along the eastern edge of the Roosevelt KGBA (Known Geothermal Resource Area). Initial eruptions resulted in two low-viscosity lava flows of nonporphyritic rhyolite. These were followed by bedded pumice falls and nonwelded ash flows. The youngest activity produced at least nine viscous domes and small lava flows of rhyolite that contain 1-5 percent phenocrysts of quartz, plagioclase, sodic sanidine, and biotite; distinction between domes and eroded flow segments locally is difficult. Potassium-argon ages indicate that all the rhyolite of the Mineral Mountains was erupted between 0.8 and 0.5 m.y. ago. The rhyolite rests on dissected granite of the Mineral Mountains pluton, the largest intrusion in Utah, which has yielded published K-Ar ages of 9 and 15 m.y. A small older dissected rhyolite dome, about 8 m.y. old, occurs just west of the range front. Whether the young ages of the pluton represent time of intrusion or of later reheating, they, in conjunction with the Pleistocene rhyolite in the Mineral Mountains, do indicate a major late Cenozoic thermal anomaly, the size and age of which is significant to evaluation of the Roosevelt KGRA. The rhyolite is also the only known source of implement-grade obsidian in the southwest between eastern California and northern New Mexico.

Utah↗

Measuring total antimony in geothermal waters by flame atomic absorption spectrometry

A flame atomic absorption procedure utilizing an electrodeless discharge lamp is described for determining total solute antimony in silica-rich geothermal waters. Following NaNO 2 oxidation of Sb +3 , SbCl 5 is extracted from 6 N HCl solution by using MIBK (methyl isobutyl ketone) ; silica in the organic layer is removed by centrifugation. The analytical detection limit for antimony is about 6 micrograms per liter in the original sample; the coefficient of variation is 4 percent at the 250 μ g/L Sb level. Comparable total antimony levels were found in sample splits which had been either filtered and acidified (to pH less than 1.5) with HNO 3 or left untreated at the time of sample collection.

Journal of Research of the U.S. Geological Survey↗

Importance of understanding bottom-up control when characterizing geothermal systems

Methods designed to identify favorable areas for geothermal resources have traditionally been focused on near-surface information, namely data that can be compiled into a 2D map. However, these methods fail to account for the third dimension: depth. As a result, they do not incorporate deep crustal and mantle features like heat sources. Geophysical methods with multi-scale capabilities, such as magnetotellurics (MT), provide tools to image deeper structures and bottom-up control on location of near surface hydrothermal systems in 3D. This study briefly demonstrates the advantage of understanding bottom-up control on hydrothermal systems to aid assessment and characterization. A regional 3D electrical resistivity model of the Great Basin is developed from MT data that images the near surface down to the mantle. From the 3D model, electrical conductance (depth integrated electrical conductivity) maps are created at logical depth intervals to identify anomalies. The conductance maps image discrete zones of high-conductance between 15-20 km depth indicative of fluid collection at the brittle-ductile transition; high-conductance zones around Moho depths (30-50 km) suggestive of partial melt; high-conductance zones in the upper mantle indicative of higher temperature and larger melt fraction, and low-conductance zones indicative of lithospheric material descending in the mantle. One anomalous zone of low-conductance in the mantle is under the north central Nevada, suggesting vertical mantle flow transport of heat to the crust related to sinking lithospheric material.

Conference Paper↗

The health hazards of volcanic and geothermal gases: A guide for the public

This guide has been prepared by the International Volcanic Health Hazard Network (IVHHN) to explain the potential adverse health effects of volcanic and geothermal gas and aerosol emissions. It provides general information on how to protect yourself and your family. The information is based on a range of evidence from academics and health and regulatory agencies. Contact your local public health or emergency management agency for information tailored to your location.

Report↗

Geothermal reservoir temperatures estimated from the oxygen isotope compositions of dissolved sulfate and water from hot springs and shallow drillholes

The oxygen isotope compositions of dissolved sulfate and water from hot springs and shallow drillholes have been tested as a geothermometer in three areas of the western United States. Limited analyses of spring and borehole fluids and existing experimental rate studies suggest that dissolved sulfate and water are probably in isotopic equilibrium in all reservoirs of significant size with temperatures above ca. 140??C and that little re-equilibration occurs during ascent to the surface. The geothermometer is, however, affected by changes in ??18O of water due to subsurface boiling and dilution and by addition of sulfate of nearsurface origin. Methods are described to calculate the effects of boiling and dilution. The geothermometer, is applied to thermal systems of Yellowstone Park, Wyoming, Long Valley, California, and Raft River, Idaho to estimate deep reservoir temperatures of 360, 240, and 142??C, respectively. ?? 1976.

Geothermics↗

Transient-pressure analysis in geothermal steam reservoirs with an immobile vaporizing liquid phase

A finite-difference model for the radial horizontal flow of steam through a porous medium is used to evaluate transient-pressure behavior in the presence of an immobile vaporizing or condensing liquid phase. Graphs of pressure drawdown and buildup in terms of dimensionless pressure and time are obtained for a well discharging steam at a constant mass flow rate for a specified time. The assumptions are made that the steam is in local thermal equilibrium with the reservoir rocks, that temperature changes are due only to phase change, and that effects of vapor-pressure lowering are negligible. Computations show that when a vaporizing liquid phase is present the pressure drawdown exhibits behavior similar to that observed in noncondensable gas reservoirs, but delayed in time. A theoretical analysis allows for the computation of this delay and demonstrates that it is independent of flow geometry. The response that occurs upon pressure buildup is markedly different from that in a noncondensable gas system. This result may provide a diagnostic tool for establishing the existence of phase-change phenomena within a reservoir. ?? 1979.

Geothermics↗

Gas chemistry and thermometry of the Cerro Prieto, Mexico, geothermal field

Gas compositions of Cerro Prieto wells in 1977 reflected strong boiling in the reservoir around wells M-20 and M-25. This boiling zone appeared to be collapsing in 1982 when a number of wells in this area of the field were shut-in. In 1977 and 1982, gas compositions also showed boiling zones corresponding to faults H and L postulated by Halfman et al. (1982). Four gas geothermometers were applied, based on reservoir equilibria and calculated fugacities. The Fisher - Tropsch reaction predicted high temperatures and appeared to re-equilibrate slowly, whereas the H2S reaction predicted low temperatures and appeared to re-equilibrate rapidly. Hydrogen and NH3 reactions were intermediate. Like gas compositions, the geothermometers reflected reservoir processes, such as boiling. Surface gas compositions are related to well compositions, but contain large concentrations of N2 originating from air dissolved in groundwater. The groundwater appears to originate in the east and flow over the production field before mixing with reservoir gases near the surface. ?? 1984.

Geothermics↗

Production induced boiling and cold water entry in the Cerro Prieto geothermal reservoir indicated by chemical and physical measurements

Chemical and physical data suggest that the relatively shallow, western part of the Cerro Prieto reservoir is bounded below by low permeability rocks, and above and at the sides by an interface with cooler water. There is no continuous permeability barrier around or immediately above the reservoir. Permeability within the reservoir is dominantly intergranular. Mixture with cooler water rather than boiling is the dominant cooling process in the natural state, and production causes displacement of hot water by cooler water, not by vapour. Local boiling occurs near most wells in response to pressure decreases, but no general vapour zone has formed. ?? 1984.

Geothermics↗

Hydrogeologic reconnaissance of the Beowawe Geysers geothermal area, Nevada

The Beowawe Geysers in north-central Nevada are the discharge from a hydrothermal-convection system in a region of high heat flow. The site of thermal-fluid upflow (at about 18 kg/s before drilling and well testing) appears to be related to the intersection at depth of two major fault zones. Assuming steady-state conditions, recharge within the drainage basin could account for both thermal and nonthermal ground-water discharge. Circulation of thermal fluid to depths exceeding 5 km is required to attain estimated temperatures of more than 220°C.

Geothermics↗

KAr ages, chemical composition and geothermal significance of cenozoic basalt near the Jordan rift

Late Cenozoic mafic lavas crop out locally along the Jordan rift. Some of these lavas are spatially associated with thermal springs, and this association has prompted some workers to hypothesize that the hot water derives its thermal energy from the shallow, still hot intrusive roots of the volcanic rocks. However, all of the volcanic rocks appear to represent mantle-derived mafic magma that rose rather quickly to the Earth's surface, without filling crustal reservoirs within which differentiation would have produced evolved, derivative products. Moreover, the lavas are too old and of too small a volume to represent the surface expression of an active reservoir of magma within the crust. These interpretations of the volcanic geology are consistent with conclusions drawn from the chemistry of the thermal water; the water has equilibrated with host rocks at no more than 110°C, probably at depths of 2–3 km. Thus, thermal springs along the Jordan rift appear to reflect heating during circulation through a regional regime of average crustal heat flow (Galanis et at. , 1986). The magmatic activity may only be a second or third order contributor to this heat flow.

Geothermics↗

Geology of the platanares geothermal area, Departamento de Copan, Honduras

Platanares is located 16 km west of Santa Rosa de Copan, Honduras, along the Quebrada del Agua Caliente. The thermal manifestations are along faults in tuffs, tuffaceous sedimentary rocks, and lavas of the Padre Miguel Group. These tuffs are silicified near the faults, are fractured, and may provide the fracture permeability necessary for the hydrothermal system. Tuffs are overlain by a wedge of terrace gravels up to 60 m thick. Quaternary conglomerates of the Quebrada del Agua Caliente are cemented by silica sinter. The Platanares area contains numerous faults, all of which appear to be extensional. There are four groups of faults (N80/sup 0/E to N70/sup 0/W, N30/sup 0/ to 60/sup 0/W, N40/sup 0/ to 65/sup 0/E, and N00/sup 0/ to 05/sup 0/W). All hot springs at this site are located along faults that trend mostly northwest and north. Twenty-eight spring groups were described over an area of 0.2 km/sup 2/; half were boiling. Based on surface temperatures and flow rates, between 0.7 and 1.0 MW thermal energy is estimated for the area. The increased temperature of the stream flowing through the thermal area indicates that several megawatts of thermal energy are being added to the stream. We recommend that a dipole-dipole resistivity line be run along the Quebrada del Agua Caliente to identify zones of fracture permeability associated with buried faults and hot water reservoirs within those fault zones. A thermal gradient corehole should be drilled at Platanares to test temperatures, lithologies, and permeability of the hydrothermal system.

Journal of Volcanology and Geothermal Research↗