USGS Science⌕ Search

SEARCH · USGS Science

Results for “Geothermics”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14Linked to original sources

Effects of geothermal development on deformation in the Long Valley Caldera, eastern California, 1985-1994

Long Valley caldera in east central California has been the site of crustal unrest in the form of seismicity and ground deformation in response to magmatic inflation since 1980. Uplift of the resurgent dome has totaled ∼0.6 m over the 1975–1992 period. Within this region of uplift, and near the southwestern edge of the resurgent dome, is the Casa Diablo area, which experienced relative subsidence of 0.17 m between 1985 and 1992. Geothermal fluid production began at Casa Diablo in 1985 to supply a binary electric power plant; currently, three such plants generate a total of about 40 MW of electricity. The plants are supplied by 170°C water pumped from depths near 150m; all the produced water is reinjected at cooler temperatures at depths near 600 m. Analyses of data from (1) regional leveling lines and a network of bench marks in the geothermal well field area, (2) tilt observations from an L‐shaped array of bench marks, and (3) calculations relating pressure and temperature changes to subsidence indicate that relative subsidence at Casa Diablo results mainly from reductions in pressure in the shallow production reservoir and overlying formations and reductions in temperature in the underlying injection reservoir. Secondary effects on deformation are caused by offsets along the Taylor‐Bryant fault bounding the west side of the well field.

California↗

Industrially induced changes in Earth structure at the geysers geothermal area, California

Industrial exploitation is causing clearly-measurable changes in Earth structure at The Geysers geothermal area, California. Production at The Geysers peaked in the late 1980s at ∼3.5 × 10³ kg s −1 of steam and 1800 MW of electricity. It subsequently decreased by about 10% per year [ Barker et al. , 1992] because of declining reservoir pressure. The steam reservoir coincides with a strong negative anomaly (∼0.16, ∼9%) in the compressional-to-shear seismic wave speed ratio V P / V S , consistent with the expected effects of low-pressure vapor-phase pore fluid [ Julian et al. , 1996]. Between 1991 and 1994 this anomaly increased in amplitude by up to about 0.07 (∼4%). This is consistent with the expected effects of continued pressure reduction and conversion of pore water to steam as a result of exploitation. These unique results show that V P / V S tomography can easily detect saturation changes caused by exploitation of reservoirs, and is a potentially valuable technique for monitoring environmental change. They also provide geophysical observational evidence that geothermal energy is not a renewable energy source.

Geophysical Research Letters↗

The fate of geothermal arsenic in the Madison and Missouri Rivers, Montana and Wyoming

Geothermal As from Yellowstone National Park causes high As concentrations (10–370 μ g/L) in the Madison and Missouri Rivers in Montana and Wyoming. Arsenic transport is largely conservative in the upper basin as demonstrated by the near equivalence of dissolved and total-recoverable As concentrations, the constancy of As loads, and consistent ratios of concentrations of As to conservative geothermal tracers. Diurnal cycling of As between aqueous and solid phases in response to p H-induced changes in sorption equilibria causes small variations of about 10–20% in dissolved As concentrations. HCl-extractable As concentrations in river and lake sediment in the upper basin are variable depending on position relative to the As-rich headwaters and geochemical and physical processes associated with lakes. In the lower Missouri River, large quantities of suspended sediment from tributaries provide sufficient sorption sites for substantial conversion of As from the aqueous phase to the solid phase.

Montana, Wyoming↗

Probabilistic 3-D time-lapse inversion of magnetotelluric data: Application to an enhanced geothermal system

Surface-based monitoring of mass transfer caused by injections and extractions in deep boreholes is crucial to maximize oil, gas and geothermal production. Inductive electromagnetic methods, such as magnetotellurics, are appealing for these applications due to their large penetration depths and sensitivity to changes in fluid conductivity and fracture connectivity. In this work, we propose a 3-D Markov chain Monte Carlo inversion of time-lapse magnetotelluric data to image mass transfer following a saline fluid injection. The inversion estimates the posterior probability density function of the resulting plume, and thereby quantifies model uncertainty. To decrease computation times, we base the parametrization on a reduced Legendre moment decomposition of the plume. A synthetic test shows that our methodology is effective when the electrical resistivity structure prior to the injection is well known. The centre of mass and spread of the plume are well retrieved.We then apply our inversion strategy to an injection experiment in an enhanced geothermal system at Paralana, South Australia, and compare it to a 3-D deterministic time-lapse inversion. The latter retrieves resistivity changes that are more shallow than the actual injection interval, whereas the probabilistic inversion retrieves plumes that are located at the correct depths and oriented in a preferential north-south direction. To explain the time-lapse data, the inversion requires unrealistically large resistivity changes with respect to the base model. We suggest that this is partly explained by unaccounted subsurface heterogeneities in the base model from which time-lapse changes are inferred.

Geophysical Journal International↗

Fungi from geothermal soils in Yellowstone National Park

Geothermal soils near Amphitheater Springs in Yellowstone National Park were characterized by high temperatures (up to 70°C), high heavy metal content, low pH values (down to pH 2.7), sparse vegetation, and limited organic carbon. From these soils we cultured 16 fungal species. Two of these species were thermophilic, and six were thermotolerant. We cultured only three of these species from nearby cool (0 to 22°C) soils. Transect studies revealed that higher numbers of CFUs occurred in and below the root zone of the perennial plant Dichanthelium lanuginosum (hot springs panic grass). The dynamics of fungal CFUs in geothermal soil and nearby nongeothermal soil were investigated for 12 months by examining soil cores and in situ mesocosms. For all of the fungal species studied, the temperature of the soil from which the organisms were cultured corresponded with their optimum axenic growth temperature.

Wyoming↗

Hydrothermal minerals and microstructures in the Silangkitang geothermal field along the Great Sumatran fault zone, Sumatra, Indonesia

Detailed study of core samples of silicic tuff recovered from three geothermal wells along the strike-slip Great Sumatran fault zone near Silangkitang, North Sumatra, supports a model for enhanced hydrothermal circulation adjacent to this major plate-boundary fault. Two wells (A and C) were drilled nearly vertically ∼1 km southwest of the eastern (i.e., the principal) fault trace, and the third, directional well (B) was drilled eastward from the site of well A to within ∼100 m of the principal fault trace. The examined core samples come from depths of 1650–2120 m at measured well temperatures of 180–320 °C. The samples collected near the principal fault trace have the highest temperatures, the largest amount of secondary pore space that correlates with high secondary permeability, and the most extensive hydrothermal mineral development. Secondary permeability and the degree of hydrothermal alteration decrease toward the southwestern margin of the fault zone. These features indicate episodic, localized flow of hot, possibly CO 2 -rich fluids within the fault zone. The microstructure populations identified in the core samples correlate to the subsidiary fault patterns typical of strike-slip faults. The geothermal reservoir appears to be centered on the fault zone, with the principal fault strands and adjoining, highly fractured and hydrothermally altered rock serving as the main conduits for vertical fluid flow and advective heat transport from deeper magmatic sources.

Great Sumatran Fault Zone, Sumatra↗

Influence of time on metamorphism of sedimentary organic matter in liquid-dominated geothermal systems, western North America

Temperature ( T in °C) and mean vitrinite reflectance ( R m in %) of sedimentary organic matter samples from six liquid-dominated geothermal systems plot about a line approximated by a regression equation of the form R m = 0.435 exp 0.00683 T . The reflectance data from these systems are strongly temperature-dependent, with a coefficient of determination ( r 2 ) of 0.8. Geologic evidence indicates that reaction duration ranges from 10 3 or 10 4 to 10 6 yr in these systems that appear to have near-maximum temperatures. The uncertainty in vitrinite reflectance and temperature determinations must account for a large part of the remaining variability not explained by the regression equation; therefore, the strong temperature dependence of R m indicates that after about 10 4 yr, reaction duration has little or no influence on metamorphism of organic matter in liquid-dominated geothermal systems. These data indicate that vitrinite reflectance can be used to determine the maximum temperature reached in hot sedimentary basins of moderate longevity.

Geology↗

Deep permeable fault–controlled helium transport and limited mantle flux in two extensional geothermal systems in the Great Basin, United States

This study assesses the relative importance of deeply circulating meteoric water and direct mantle fluid inputs on near-surface 3 He/ 4 He anomalies reported at the Coso and Beowawe geothermal fields of the western United States. The depth of meteoric fluid circulation is a critical factor that controls the temperature, extent of fluid-rock isotope exchange, and mixing with deeply sourced fluids containing mantle volatiles. The influence of mantle fluid flux on the reported helium anomalies appears to be negligible in both systems. This study illustrates the importance of deeply penetrating permeable fault zones (10 −12 to 10 −15 m 2 ) in focusing groundwater and mantle volatiles with high 3 He/ 4 He ratios to shallow crustal levels. These continental geothermal systems are driven by free convection.

Great Basin↗

Hydrologic models of modern and fossil geothermal systems in the Great Basin: Genetic implications for epithermal Au-Ag and Carlin-type gold deposits

The Great Basin region in the western United States contains active geothermal systems, large epithermal Au-Ag deposits, and world-class Carlin-type gold deposits. Temperature profiles, fluid inclusion studies, and isotopic evidence suggest that modern and fossil hydrothermal systems associated with gold mineralization share many common features, including the absence of a clear magmatic fluid source, discharge areas restricted to fault zones, and remarkably high temperatures (>200 ??C) at shallow depths (200-1500 m). While the plumbing of these systems varies, geochemical and isotopic data collected at the Dixie Valley and Beowawe geothermal systems suggest that fluid circulation along fault zones was relatively deep (>5 km) and comprised of relatively unexchanged Pleistocene meteoric water with small (<2.5%) shifts from the meteoric water line (MWL). Many fossil ore-forming systems were also dominated by meteoric water, but usually exhibit ??18O fluid-rock interactions with larger shifts of 5???-20??? from the MWL. Here we present a suite of two-dimensional regional (100 km) and local (40-50 km) scale hydrologic models that we have used to study the plumbing of modern and Tertiary hydrothermal systems of the Great Basin. Geologically and geophysically consistent cross sections were used to generate somewhat idealized hydrogeologic models for these systems that include the most important faults, aquifers, and confining units in their approximate configurations. Multiple constraints were used, including enthalpy, ??18O, silica compositions of fluids and/or rocks, groundwater residence times, fluid inclusion homogenization temperatures, and apatite fission track anomalies. Our results suggest that these hydrothermal systems were driven by natural thermal convection along anisotropic, subvertical faults connected in many cases at depth by permeable aquifers within favorable lithostratigraphic horizons. Those with minimal fluid ?? 18O shifts are restricted to high-permeability fault zones and relatively small-scale (???5 km), single-pass flow systems (e.g., Beowawe). Those with intermediate to large isotopic shifts (e.g., epithermal and Carlin-type Au) had larger-scale (???15 km) loop convection cells with a greater component of flow through marine sedimentary rocks at lower water/rock ratios and greater endowments of gold. Enthalpy calculations constrain the duration of Carlin-type gold systems to probably <200 k.y. Shallow heat flow gradients and fluid silica concentrations suggest that the duration of the modern Beowawe system is <5 k.y. However, fluid flow at Beowawe during the Quaternary must have been episodic with a net duration of ???200 k.y. to account for the amount of silica in the sinter deposits. In the Carlin trend, fluid circulation extended down into Paleozoic siliciclastic rocks, which afforded more mixing with isotopically enriched higher enthalpy fluids. Computed fission track ages along the Carlin trend included the convective effects, and ranged between 91.6 and 35.3 Ma. Older fission track ages occurred in zones of groundwater recharge, and the younger ages occurred in discharge areas. This is largely consistent with fission track ages reported in recent studies. We found that either an amagmatic system with more permeable faults (10-11 m2) or a magmatic system with less permeable faults (10-13 m2) could account for the published isotopic and thermal data along the Carlin trend systems. Localized high heat flow beneath the Muleshoe fault was needed to match fl uid inclusion temperatures at Mule Canyon. However, both magmatic and amagmatic scenarios require the existence of deep, permeable faults to bring hot fluids to the near surface. ?? 2008 Geological Society of America.

Geosphere↗

Coniform stromatolites from geothermal systems, North Island, New Zealand

Coniform stromatolites are found in several sites in the Tokaanu and Whakarewarewa geothermal areas of North Island, New Zealand. At Tokaanu, silicification of these stromatolites is taking place in Kirihoro, a shallow hot springfed pool. At Whakarewarewa, subfossil silicified coniform stromatolites are found on the floor of "Waikite Pool" on the discharge apron below Waikite Geyser, and in an old sinter succession at Te Anarata. The microbes in the coniform stromatolites from Tokaanu, Waikite Pool, and Te Anarata have been well preserved through rapid silicification. Nevertheless, subtle differences in the silicification style induced morphological variations that commonly mask or alter morphological features needed for identification of the microbes in terms of extant taxa. The coniform stromatolites in the New Zealand hotspring pools are distinctive because (1) they are formed of upward tapering (i.e., conical) columns, (2) neighboring columns commonly are linked by vertical sheets or bridges, (3) internally, they are formed of alternating high- and low-porosity laminae that have a conical vertical profile, and (4) Phormidium form more than 90% of the biota. As such, they are comparable to modern coniform mats and stromatolites found in the geothermal systems of Yellowstone National Park and ice-covered lakes in Antarctica. Formation of the coniform stromatolites is restricted to pools that are characterized by low current energy and a microflora that is dominated by Phormidium. These delicate and intricate stromatolites could not form in areas characterized by fast flowing water or a diverse microflora. Thus, it appears that the distribution of these distinctive stromatolites is controlled by biological constraints that are superimposed on environmental needs.

Palaios↗

Seismicity rate change at the Coso Geothermal Field following the July 2019 Ridgecrest M7.1 earthquake

Many geothermal and volcanic regions experience remote and regional triggering following large earthquakes. The transient or permanent changes in stresses acting on faults and fractures can lead to changes in seismicity rates following either the passage of teleseismic waves or the permanent change in stresses following regional events. One such region of prevalent triggering is the Coso Geothermal Field (CGF) in eastern California, which is located roughly 30km to the north of the 2019 M7.1 Ridgecrest epicenter. Previous regional earthquakes have seemingly caused increases in seismicity rate surrounding the CGF, but also showed an absence of such rate increases in the CGF itself. To test whether seismicity rates in the CGF were dissimilar to the surrounding area following the M7.1 Ridgecrest earthquake, I carry out seismicity rate change calculations using a catalog of seismicity complied using a local seismic network and find that the CGF behaves identical to the surrounding area. Comparisons of seismicity rate changes calculated using a regional network derived catalog and the local network derived catalog show that for a moderate, regional earthquake, the local network catalog reveals a change in seismicity rate while the regionally network catalog shows no significant changes. The differences are likely related to incomplete sampling of seismicity using the regional network due to the existence of a very shallow brittle ductile transition centered on the CGF. The CGF thus is prone to triggering from both teleseismic and regional earthquakes.

California↗

Phase separation in seafloor geothermal systems: An experimental study of the effects on metal transport

Experimental investigations were carried out by reacting natural and evolved sea-water with crystalline basalt from the Juan de Fuca Ridge in order to study the effects of vapour-liquid phase separation on metal mobilization in sea-floor geothermal systems in which phase separation occurs between the top of a magma chamber (300-500 bar) and the sea-floor (230-250 bar). The geochemical processes produced by a combination of closed-system phase separation and adiabatic expansion under the conditions characterizing the sea-floor geothermal systems resulted in a significant increase in the acidity and concentration of heavy metals in the liquid phase and strikingly high concentrations of metals in the vapour.

American Journal of Science↗

Spatial patterns of diagenesis during geothermal circulation in carbonate platforms

Geothermal convection of seawater deep in carbonate platforms could provide the necessary supply of magnesium for dolomitization at temperatures high enough to overcome kinetic limitations. We used reactive-transport simulations to predict the rates and spatial patterns of dolomitization during geothermal convection in a platform that was 40 km across and 2 km thick. In the simulations, porosity and permeability decrease with depth to account for sediment compaction. Dolomitization of a platform consisting of medium grained (∼0.05 mm) sediments occurred in a broad band ranging from ∼2.5 km depth near the margin to ∼1.5 km depth near the platform center. The area of dolomitization is deep enough that temperatures exceed ∼50°C but not so deep that low permeabilities restrict mass transport. Complete dolomitization in the center of this zone is estimated to require at least 60 my. Incorporation of permeability contrasts, permeable beds, and reactive beds focused dolomitization strongly and reduced the estimated time required for dolomitization by as much as 50 percent. Dolomitization created magnesium-depleted, calcium-rich fluids in less than 10 ky, and results support a link between dolomitization and anhydrite precipitation where adequate sulfate is available.

American Journal of Science↗

Geothermal resources of southern Idaho

The geothermal resource of southern Idaho as assessed by the U.S. Geological Survey in 1978 is large. Most of the known hydrothermal systems in southern Idaho have calculated reservoir temperatures of less than 150?C. Water from many of these systems is valuable for direct heat applications, but is lower than the temperature of interest for commercial generation of electricity at the present time. Most of the known and inferred geothermal resources of southern Idaho underlie the Snake River Plain. However, major uncertainties exist concerning the geology and temperatures beneath the plain. By far the largest hydrothermal system in Idaho is in the Bruneau-Grand View area of the western Snake River Plain with a calculated reservoir temperature of 107?C and an energy of 4.5? 10 20 joules. No evidence of higher temperature water associated with this system has been found. Although the geology of the eastern Snake River Plain suggests that a large thermal anomaly may underlie this area of the plain, direct evidence of high temperatures has not been found. Large volumes of water at temperatures between 90? and 150?C probably exist along the margins of the Snake River Plain and in local areas north and south of the plain. Areas that appear particularly promising for the occurrence of large high-temperature hydrothermal systems are: the area north of the Snake River Plain and west of the Idaho batholith, the Island Park area, segments of the margins of the eastern Snake River Plain, and the Blackfoot lava field.

Circular↗

Distribution of high-temperature (>150 °C) geothermal resources in California

California contains, by far, the greatest geothermal generating capacity in the United States, and with the possible exception of Alaska, the greatest potential for the development of additional resources. California has nearly 2/3 of the US geothermal electrical installed capacity of over 3,000 MW. Depending on assumptions regarding reservoir characteristics and future market conditions, additional resources of between 2,000 and 10,000 MWe might be developed (see e.g., Muffler, 1979).

California↗

Physical-Property Measurements on Core samples from Drill-Holes DB-1 and DB-2, Blue Mountain Geothermal Prospect, North-Central Nevada

From May to June 2008, the U.S. Geological Survey (USGS) collected and measured physical properties on 36 core samples from drill-hole Deep Blue No. 1 (DB-1) and 46 samples from drill-hole Deep Blue No. 2 (DB-2) along the west side of Blue Mountain about 40 km west of Winnemucca, Nev. These data were collected as part of an effort to determine the geophysical setting of the Blue Mountain geothermal prospect as an aid to understanding the geologic framework of geothermal systems throughout the Great Basin. The physical properties of these rocks and other rock types in the area create a distinguishable pattern of gravity and magnetic anomalies that can be used to infer their subsurface geologic structure. Drill-holes DB-1 and DB-2 were spudded in alluvium on the western flank of Blue Mountain in 2002 and 2004, respectively, and are about 1 km apart. Drill-hole DB-1 is at a ground elevation of 1,325 m and was drilled to a depth of 672 m and drill-hole DB-2 is at a ground elevation of 1,392 m and was drilled to a depth of 1522 m. Diameter of the core samples is 6.4 cm. These drill holes penetrate Jurassic and Triassic metasedimentary rocks predominantly consisting of argillite, mudstone, and sandstone; Tertiary diorite and gabbro; and younger Tertiary felsic dikes.

Open-File Report↗

A time-lapse gravity survey of the Coso geothermal field, China Lake Naval Air Weapons Station, California

We have conducted a gravity survey of the Coso geothermal field to continue the time-lapse gravity study of the area initiated in 1991. In this report, we outline a method of processing the gravity data that minimizes the random errors and instrument bias introduced into the data by the Scintrex CG-5 relative gravimeters that were used. After processing, the standard deviation of the data was estimated to be ±13 microGals. These data reveal that the negative gravity anomaly over the Coso geothermal field, centered on gravity station CER1, is continuing to increase in magnitude over time. Preliminary modeling indicates that water-table drawdown at the location of CER1 is between 65 and 326 meters over the last two decades. We note, however, that several assumptions on which the model results depend, such as constant elevation and free-water level over the study period, still require verification.

California↗

Seismic hazard assessment at the Fallon, Nevada, Frontier Observatory for Research in Geothermal Energy site

Enhanced geothermal systems (EGS) technology aims to engineer a productive geothermal reservoir in regions of hot, but low permeability, rocks. In any EGS operation, the rock mass requires stimulation by high pressure injection of fluids, which has the potential to induce seismicity. To address the seismic hazard specifically, a probabilistic seismic hazard assessment (PSHA) is often required and is generally part of an induced seismicity mitigation plan (ISMP). A specific PSHA for the proposed Fallon, Nev., FORGE site is outlined below that relies solely on hypothetical stimulation scenarios and analog sites to assess the hazard of induced seismicity in the absence of local microseismicity. Partially due to the lack of existing seismicity at the site and partially to arrive at conservative estimates of the hazard, the PSHA is calculated for a range of b-values. Results indicate that the conservative estimates of seismic hazard at locations having significant, sensitive infrastructure near the proposed site are very low.

Nevada↗