USGS ScienceSearch

USGS · wsp1748

Apparatus and techniques for measuring bedload

Abstract

The need for accurate determinations of the total sediment discharge of particles of bedload size has prompted this investigation of available and possible measuring apparatus and procedures. The accuracy of measurements of sediment discharge made with trap-type samplers is affected by the variability of sampler efficiency, by the oscillatory variation of bedload discharge, and by sampler placement. Equations that were developed for determining total discharge from measured bedioad discharge and measured suspended-sediment discharge are simplest if the bedload apparatus measures only the true bedload. Early bedload samplers are generally unsatisfactory. Recently developed or suggested apparatus include various improved samplers of the pressure-difference type, a pumping sampler, a magnetic sampler, acoustical instruments that measure the magnitude of the sound of particle collisions, an ultrasonic bedload sampler designed to measure and integrate electronically the concentration and velocity, and a tiltmeter designed to measure the total sediment discharge from the ground tilt that results from the passage of flow. All the pressure-difference samplers are improvements over early samplers, but none are void of the inherent shortcomings of trap-type apparatus; probably the Sphinx (Dutch) and VUV (Hungarian) samplers are the most satisfactory. The acoustical instruments are capable of measuring only the relative discharge. The ultrasonic sampler and the tiltmeter are not adequate without further development. Some new possible apparatus and means for measuring or aiding in measuring bedload discharge are small pit samplers, ultrasonic sounders, pressure transducers, and photography. A small pit sampler for measuring bedload discharge was designed to provide self-placement and portability ; however, its practicability and efficiency are undetermined. Exploratory films show that by using slowmotion photography the discharge of particles larger than about pea size can be determined provided the flow is clear; however, photography generally is not practical. Ultrasonic sounders provide continuous and accurate data on bed configuration and dune movement for use in equations that were developed for computing the bedload discharge. Computations with the equations indicate that the interpretation of the sounding data needs further study. Pressure transducers placed beneath the bed surface possibly can be used to provide information on dune movement; however, their installation would be difficult. The time required for collecting data on bed configuration and dune movement throughout a cross section could be substantially reduced by using several transducers simultaneously in conjunction with an ultrasonic sounder. A modified ultrasonic sounder that provides information on the shape and velocity of large particles and a method for determining the discharge of such particles were proposed; the method seems most feasible for particles of high sphericity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David Wellington Hubbell. 1964. Apparatus and techniques for measuring bedload. https://doi.org/10.3133/wsp1748

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Basic ground-water hydrology

Ground water is one of the Nation's most valuable natural resources. It is the source of about 40 percent of the water used for all purposes exclusive of hydropower generation and electric powerplant cooling. Surprisingly, for a resource that is so widely used and so important to the health and to the economy of the country, the occurrence of ground water is not only poorly understood but is also, in fact, the subject of many widespread misconceptions. Common misconceptions include the belief that ground water occurs in underground rivers resembling surface streams whose presence can be detected by certain individuals. These misconceptions and others have hampered the development and conservation of ground water and have adversely affected the protection of its quality. In order for the Nation to receive maximum benefit from its ground-water resource, it is essential that everyone, from the rural homeowner to managers of industrial and municipal water supplies to heads of Federal and State water-regulatory agencies, become more knowledgeable about the occurrence, development, and protection of ground water. This report has been prepared to help meet the needs of these groups, as well as the needs of hydrologists, well drillers, and others engaged in the study and development of ground-water supplies. It consists of 45 sections on the basic elements of ground-water hydrology, arranged in order from the most basic aspects of the subject through a discussion of the methods used to determine the yield of aquifers to a discussion of common problems encountered in the operation of ground-water supplies. Each section consists of a brief text and one or more drawings or maps that illustrate the main points covered in the text. Because the text is, in effect, an expanded discussion of the illustrations, most of the illustrations are not captioned. However, where more than one drawing is included in a section, each drawing is assigned a number, given in parentheses, and these numbers are inserted at places in the text where the reader should refer to the drawing. In accordance with U.S. Geological Survey policy to encourage the use of metric units, these units are used in most sections. In the sections dealing with the analysis of aquifer (pumping) test data, equations are given in both consistent units and in the inconsistent inch-pound units still in relatively common use among ground-water hydrologists and well drillers. As an aid to those who are not familiar with metric units and with the conversion of ground-water hydraulic units from inch-pound units to metric units, conversion tables are given on the inside back cover. Definitions of ground-water terms are given where the terms are first introduced. Because some of these terms will be new to many readers, abbreviated definitions are also given on the inside front cover for convenient reference by those who wish to review the definitions from time to time as they read the text. Finally, for those who need to review some of the simple mathematical operations that are used in ground-water hydrology, a section on numbers, equations, and conversions is included at the end of the text.

Water Supply Paper

Validation of a numerical modeling method for simulating rainfall-runoff relations for headwater basins in western King and Snohomish Counties, Washington

The validity of a previously determined numerical modeling method was assessed. Numerical models for 11 drainage basins were constructed with the Hydrologic Simulation Program-FORTRAN (HSPF) with parameter values that were generalized for the physiographic region. Large and recurrent simulation errors were initially identified, but three systematic modifications of the models corrected those errors for 10 out of the 11 basins. The validity of the numerical modeling method for simulating rainfall-runoff relations in the study area, as modified during this investigation, was not rejected, but observed streamflow data were needed to apply the method.

Water Supply Paper

Sediment-quality assessment of Franklin D. Roosevelt Lake and the upstream reach of the Columbia River, Washington, 1992

Elevated concentrations of trace elements were found in bed sediment of Lake Roosevelt and the Columbia River, its principal source of inflow. Trace-element concentrations in whole water samples did not exceed criteria for freshwater organisms. Bed sediments of Lake Roosevelt were analyzed for organic compounds associated with wood-pulp waste. Dioxins and furans were found in suspended sediment and water of the Columbia River. Abundance and diversity of benthic invertebrate communities were analyzed.

Water Supply Paper