Chapter 3. Determination of semivolatile organic compounds and polycyclic aromatic hydrocarbons in solids by gas chromatography/mass spectrometry

Abstract

A method for the determination of 38 polycyclic aromatic hydrocarbons (PAHs) and semivolatile organic compounds in solid samples is described. Samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from the solid sample twice at 13,800 kilopascals; first at 120 degrees Celsius using a water/isopropyl alcohol mixture (50:50, volume-to-volume ratio), and then the sample is extracted at 200 degrees Celsius using a water/isopropyl alcohol mixture (80:20, volume-to-volume ratio). The compounds are isolated using disposable solid-phase extraction (SPE) cartridges containing divinylbenzene-vinylpyrrolidone copolymer resin. The cartridges are dried with nitrogen gas, and then sorbed compounds are eluted from the SPE material using a dichloromethane/diethyl ether mixture (80:20, volume-to-volume ratio) and passed through a sodium sulfate/Florisil SPE cartridge to remove residual water and to further clean up the extract. The concentrated extract is solvent exchanged into ethyl acetate and the solvent volume reduced to 0.5 milliliter. Internal standard compounds are added prior to analysis by capillary-column gas chromatography/mass spectrometry. Comparisons of PAH data for 28 sediment samples extracted by Soxhlet and the accelerated solvent extraction (ASE) method described in this report produced similar results. Extraction of PAH compounds from standard reference material using this method also compared favorably with Soxhlet extraction. The recoveries of PAHs less than molecular weight 202 (pyrene or fluoranthene) are higher by up to 20 percent using this ASE method, whereas the recoveries of PAHs greater than or equal to molecular weight 202 are equivalent. This ASE method of sample extraction of solids has advantages over conventional Soxhlet extraction by increasing automation of the extraction process, reducing extraction time, and using less solvent. Extract cleanup also is greatly simplified because SPE replaces commonly used gel permeation chromatography. The performance of the method (as expressed by mean recoveries and mean precision) was determined using Ottawa sand, a commercially available topsoil, and an environmental stream sediment, fortified at 1.5 and 15 micrograms per compound. Recoveries of PAH and semivolatile compounds in Ottawa sand samples fortified at 1.5 micrograms averaged 88 percent ? 9.4 percent relative standard deviation, and calculated initial method detection limits per compound averaged 14 micrograms per kilogram, assuming a 25-gram sample size. The recovery for 1,2,4-trichlorobenzene is less than 60 percent; thus, the concentration of this compound will always be reported as estimated with the E remark code. The analysis of 25 alkylated PAH homolog groups also can be determined with this method with extra data analysis and review, but because of the lack of authentic reference standard compounds, these results are considered to be semiquantitative. The PAH homolog groups are quantitated using the response factor of a parent PAH method compound, if available. Precision data for the alkylated PAH homologs detected in a marine sediment standard reference material (SRM 1944) also are presented to document and demonstrate method capability.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Steven D. Zaugg, Mark R. Burkhardt, Teresa L. Burbank, Mary C. Olson, Jana L. Iverson, Michael P. Schroeder. 2006. Chapter 3. Determination of semivolatile organic compounds and polycyclic aromatic hydrocarbons in solids by gas chromatography/mass spectrometry. https://doi.org/10.3133/tm5b3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

dMODELS, a MATLAB software package for modeling crustal deformation near volcanic centers and active faults using Global Navigation Satellite System data—User guide

dMODELS is a MATLAB software package that implements the most common analytical models used to interpret deformation measurements near faults and active volcanic centers. This manual focuses on inversion of deformation data from the Global Navigation Satellite System (GNSS). The included case studies emphasize the GNSS inversion component of the software. Source models include pressurized spherical, spheroidal, and horizontal sill (penny-crack) magma reservoirs in a homogeneous, elastic, isotropic, flat half-space. A topography correction is available for the spherical source. Dikes and faults are described following the mathematical notation for the rectangular dislocations in a homogeneous, elastic, flat half-space. Equations have been reviewed for typographical errors present in the original literature and verified against finite-element method numerical models. GNSS data from the 2006 eruption at Augustine Volcano, Alaska; the 1998–2000 unrest at Taal Volcano, Philippines; and the 2009 earthquake in L’Aquila, Italy, are used to demonstrate the application of the software package.

Techniques and Methods

Aspergillosis (Avian) case definition for wildlife

Diagnostic laboratories receive carcasses and samples for diagnostic evaluation and pathogen/toxin detection. Case definitions bring clarity and consistency to the evaluation process. Their use within and between organizations allows more uniform reporting of diseases and etiologic agents. The intent of a case definition is to provide scientifically based criteria for determining: (a) if an individual carcass has a specific disease and degree of confidence in that diagnosis and (b) if there is evidence of a pathogen or toxin in a carcass or sample (for example, swab, tissue sample, skin scraping, blood/serum sample, environmental sample, or other). This case definition is specific to aspergillosis and applies to all avian species.

Techniques and Methods

Field sampling guidelines for developing and verifying satellite remote sensing chlorophyll a concentration and fluorescence models in inland waters

Harmful algal blooms are increasing in frequency in inland waters across the United States, resulting in a need to monitor phytoplankton bloom events to track ecosystem health and productivity. Remote sensing of chlorophyll a values offers a cost-effective and powerful method for early detection and characterization of bloom events and serves as an overall indicator of water quality and trophic state, with regular, repeated sampling of landscape-wide, high spatial resolution measurements. Field measurements are necessary for developing and verifying chlorophyll a retrieval models. For model verification, chlorophyll a concentration or fluorescence and light attenuation measurements are needed; for model development, turbidity and colored dissolved organic matter concentration measurements are additionally needed; and for model development and verification, radiometric measurements, taxonomic identification of phytoplankton, inherent optical properties, and cyanotoxin concentration are further measurements that can provide context. This report outlines detailed methods and priority considerations for collecting high-quality field data in inland waters (defined as rivers, lakes, reservoirs, estuaries, streams, and wetlands). The described methods include best practices for collecting and preparing discretely collected water samples and for calibration, maintenance, and quality assurance and quality control of field sensors. Whereas the priorities will vary between applications, some general guidelines are to collect field samples (1) as close in time to a satellite overpass as possible, (2) from representative areas of the waterbody to capture the range of spatial variability, and (3) near the surface to match remote sensing reflectance data.

Techniques and Methods