USGS ScienceSearch

USGS · tm10C15

Determination of the delta(15N/14N)of Ammonium (NH4+) in Water: RSIL Lab Code 2898

Abstract

The purpose of the technique described by Reston Stable Isotope Laboratory (RSIL) lab code 2898 is to determine the N isotopic composition, delta(15N/14N), abbreviated as d15N, of ammonium (NH4+) in water (freshwater and saline water). The procedure involves converting dissolved NH4+ into NH3 gas by raising the pH of the sample to above 9 with MgO and subsequently trapping the gas quantitatively as (NH4)2SO4 on a glass fiber (GF) filter. The GF filter is saturated with NaHSO4 and pressure sealed between two gas-permeable polypropylene filters. The GF filter 'sandwich' floats on the surface of the water sample in a closed bottle. NH3 diffuses from the water through the polypropylene filter and reacts with NaHSO4, forming (NH4)2SO4 on the GF filter. The GF filter containing (NH4)2SO4 is dried and then combusted with a Carlo Erba NC 2500 elemental analyzer (EA), which is used to convert total nitrogen in a solid sample into N2 gas. The EA is connected to a continuous-flow isotope-ratio mass spectrometer (CF-IRMS), which determines the relative difference in ratios of the amounts of the stable isotopes of nitrogen (15N and 14N) of the product N2 gas and a reference N2 gas. The filters containing the samples are compressed in tin capsules and loaded into a Costech Zero-Blank Autosampler on the EA. Under computer control, samples then are dropped into a heated reaction tube that contains an oxidant, where combustion takes place in a He atmosphere containing an excess of O2 gas. To remove S-O gases produced from the NaHSO4, a plug of Ag-coated Cu wool is inserted at the bottom of the reaction tube. Combustion products are transported by a He carrier through a reduction furnace to remove excess O2, toconvert all nitrogen oxides to N2, and to remove any remaining S-O gases. The gases then pass through a drying tube to remove water. The gas-phase products, mainly N2 and a small amount of background CO2, are separated by a gas chromatograph (GC). The gas is then introduced into the IRMS through a Finnigan ConFlo II interface. The ConFlo II interface is used to introduce not only sample into the IRMS but also N2 reference gas and He for sample dilution. The flash combustion is quantitative, so no isotopic fractionation is involved. The IRMS is a Finnigan Delta V CF-IRMS with 10 cups and is capable of detecting ion beams with mass/charge (m/z) 28, 29, 30. The ion beams from N2 are as follows: m/z 28 = 14N14N, m/z 29 = 14N15N, and m/z 30 = 15N15N. The ion beam with m/z 30 also represents 14N16O, which may indicate contamination or incomplete reduction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Janet E. Hannon, John Karl Böhlke. 2008. Determination of the delta(15N/14N)of Ammonium (NH4+) in Water: RSIL Lab Code 2898. https://doi.org/10.3133/tm10c15

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

dMODELS, a MATLAB software package for modeling crustal deformation near volcanic centers and active faults using Global Navigation Satellite System data—User guide

dMODELS is a MATLAB software package that implements the most common analytical models used to interpret deformation measurements near faults and active volcanic centers. This manual focuses on inversion of deformation data from the Global Navigation Satellite System (GNSS). The included case studies emphasize the GNSS inversion component of the software. Source models include pressurized spherical, spheroidal, and horizontal sill (penny-crack) magma reservoirs in a homogeneous, elastic, isotropic, flat half-space. A topography correction is available for the spherical source. Dikes and faults are described following the mathematical notation for the rectangular dislocations in a homogeneous, elastic, flat half-space. Equations have been reviewed for typographical errors present in the original literature and verified against finite-element method numerical models. GNSS data from the 2006 eruption at Augustine Volcano, Alaska; the 1998–2000 unrest at Taal Volcano, Philippines; and the 2009 earthquake in L’Aquila, Italy, are used to demonstrate the application of the software package.

Techniques and Methods

Aspergillosis (Avian) case definition for wildlife

Diagnostic laboratories receive carcasses and samples for diagnostic evaluation and pathogen/toxin detection. Case definitions bring clarity and consistency to the evaluation process. Their use within and between organizations allows more uniform reporting of diseases and etiologic agents. The intent of a case definition is to provide scientifically based criteria for determining: (a) if an individual carcass has a specific disease and degree of confidence in that diagnosis and (b) if there is evidence of a pathogen or toxin in a carcass or sample (for example, swab, tissue sample, skin scraping, blood/serum sample, environmental sample, or other). This case definition is specific to aspergillosis and applies to all avian species.

Techniques and Methods

Field sampling guidelines for developing and verifying satellite remote sensing chlorophyll a concentration and fluorescence models in inland waters

Harmful algal blooms are increasing in frequency in inland waters across the United States, resulting in a need to monitor phytoplankton bloom events to track ecosystem health and productivity. Remote sensing of chlorophyll a values offers a cost-effective and powerful method for early detection and characterization of bloom events and serves as an overall indicator of water quality and trophic state, with regular, repeated sampling of landscape-wide, high spatial resolution measurements. Field measurements are necessary for developing and verifying chlorophyll a retrieval models. For model verification, chlorophyll a concentration or fluorescence and light attenuation measurements are needed; for model development, turbidity and colored dissolved organic matter concentration measurements are additionally needed; and for model development and verification, radiometric measurements, taxonomic identification of phytoplankton, inherent optical properties, and cyanotoxin concentration are further measurements that can provide context. This report outlines detailed methods and priority considerations for collecting high-quality field data in inland waters (defined as rivers, lakes, reservoirs, estuaries, streams, and wetlands). The described methods include best practices for collecting and preparing discretely collected water samples and for calibration, maintenance, and quality assurance and quality control of field sensors. Whereas the priorities will vary between applications, some general guidelines are to collect field samples (1) as close in time to a satellite overpass as possible, (2) from representative areas of the waterbody to capture the range of spatial variability, and (3) near the surface to match remote sensing reflectance data.

Techniques and Methods