Hydrogeologic characterization of Area B, Fort Detrick, Maryland

Abstract

Groundwater in the karst groundwater system at Area B of Fort Detrick in Frederick County, Maryland, is contaminated with chlorinated solvents from the past disposal of laboratory wastes. In cooperation with U.S. Army Environmental Command and U.S. Army Garrison Fort Detrick, the U.S. Geological Survey performed a 3-year study to refine the conceptual model of groundwater flow in and around Area B of Fort Detrick at the site- to regional-scale. The investigation was designed to review the geologic setting, assess the temporal variability of the hydrologic system, evaluate the potential for interbasin groundwater flow, determine the degree of vertical connectivity of the aquifer, characterize the sources and timing of groundwater recharge, and identify if dyes from previous tracer tests continue to drain from the aquifer. This study established a continuous hydrologic monitoring network of 12 water level gages, 2 streamgages, a precipitation gage, and in situ fluorometric monitoring. A water budget analysis was performed using hydrologic monitoring data and a soil-water balance model constructed for the study. In this study each individual water budget term is calculated using available data or through modeling, and a water budget residual term is calculated. If the water budget residual term is small relative to the uncertainty of the underlying data, then an additional import or export of water (in other words, interbasin transfer) is not needed to fully describe the hydrologic system. Groundwater and spring samples from 20 locations were collected in a 2019 synoptic geochemical sampling event and analyzed for a suite of analytes that included groundwater age tracer constituents. The karst groundwater system was found to be highly responsive to hydrologic events, with strong water level and stream base flow responses to individual storm events and a historic wet period in 2017 and 2018. The water budget analysis included historic flooding in May 2018, though more typical hydrologic patterns were observed in 2019 and 2020. During most evaluated intervals, the water budget residual was less than the estimated uncertainty on the residual for the two Carroll Creek watersheds, which suggested no substantial net interbasin flow occurs from these watersheds. The watershed difference area, a region that includes Area B, had a significant negative water budget residual, which may be the result of a net interbasin import of groundwater or the result of focused groundwater recharge not simulated by the soil-water balance model. Geochemical analysis and groundwater age dating reveals shallow groundwater (approximately less than [<] 150 feet deep) appears to be relatively young (approximately <30 years) and to be recharged in the vicinity of Area B. In the deep groundwater sampled in this study (approximately greater than [>] 150 feet deep), older groundwater from a differing recharge source, based on stable isotopes and noble gas analyses, is observed and interpreted to represent less direct connectivity to the surface and increased proportions of water recharged to the north and (or) west of Area B. A clustering analysis to reveal groupings within the suite of geochemical data was used to define seven groups. The groupings generally show that wells in similar depths and lateral aquifer positions generally cluster together, with some exceptions. Although limited by suspended sediments, the in situ fluorometric monitoring at springs did not detect any dye leaving the system above the limit of detection for the method. Dye was only detected above the limit of detection in one well, which was used as an injection well during a previous dye tracer test. The results of this study support and refine the conceptual site model of groundwater hydrology at Area B. The geologic and geophysical log review in this study agrees with prior assessments of physical controls on groundwater flow. A literature review of mid-Atlantic karst studies identified similar controls reported in these environments. The additional characterization of hydrologic responsiveness in this study suggests that hydrologic conditions and events are important considerations when interpreting potentiometric surfaces and contaminant trends over time and highlights the importance of continuous hydrologic monitoring. There is evidence to suggest that either intense focused groundwater recharge occurs in the vicinity of Area B or net along-valley groundwater interbasin flow from the upper study watershed enters the lower watershed and discharges to Carroll Creek. Geochemical analyses also suggest that water recharged from Catoctin Mountain and the elevated areas to the north and (or) west of the site may be present in the older and deeper Area B groundwater.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 39.41628758896462° to 39.458154924593° latitude; -77.4693386578843° to -77.38630852298522° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Phillip J. Goodling, Brandon J. Fleming, John Solder, Alexander M. Soroka, Jeff P. Raffensperger. 2023-05-02. Hydrogeologic characterization of Area B, Fort Detrick, Maryland. https://doi.org/10.3133/sir20225054

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗