USGS Science⌕ Search

USGS · sir20195122

Hydrogeologic characterization, groundwater chemistry, and vulnerability assessment, Ute Mountain Ute Reservation, Colorado and Utah

Abstract

The U.S. Geological Survey, in cooperation with the Ute Mountain Ute Tribe (UMUT), initiated a study in 2016 to increase understanding of the hydrogeology and chemistry of groundwater within select areas of the Ute Mountain Ute Reservation (UMUR) in Colorado and Utah, identify vulnerabilities to the system and other natural resources, and outline information needs to aid in the understanding and protection of groundwater resources. The results presented for this study can be used to support the UMUT’s goal of protecting their vital groundwater resources on the UMUR. Hydrogeologic conditions were characterized for the surficial aquifer contained in Quaternary-age unconsolidated surficial deposits and the Dakota aquifer contained in the Cretaceous-age Dakota Sandstone. In the surficial aquifer, median depth to water ranges from about 5.4 to 17.2 feet below land surface in the Farm and Ranch Enterprise area and 11 to 34 feet below land surface in the Towaoc area, and the water table slopes generally southwest or south. A map of depth to the top of the Dakota Sandstone was constructed from existing well data. Depths range from zero in outcrop areas to more than 3,000 feet below land surface on mesas in the southeastern part of the UMUR. Groundwater-chemistry data were collected by the UMUT from 13 springs and 31 wells from 1996 through 2017. Specific conductance was much lower for samples from springs than from wells; median values were 512 and 6,024 microsiemens per centimeter at 25 degrees Celsius, respectively. Spring samples were well oxygenated. A few well samples were anoxic (dissolved oxygen concentrations less than 0.5 milligrams per liter [mg/L]), indicating reducing conditions in the aquifer. About 75 percent of spring samples had fresh water (total dissolved solids concentrations less than 1,000 mg/L), and about 85 percent of well samples had brackish or highly saline water (total dissolved solids concentrations greater than 1,000 mg/L). Water type for springs on the Ute Mountains was calcium bicarbonate. Lower-altitude springs had a calcium-sulfate water type. Most well samples had sodium as the dominant cation, and sulfate, bicarbonate, and chloride as the dominant anions. Fluoride concentrations in about 45 percent of well samples were greater than an agricultural-use standard of 2 mg/L. Nitrate plus nitrite concentrations in most spring and well samples were less than about 1.6 mg/L per liter. Concentrations in samples from wells in the irrigated agricultural area were elevated; the maximum concentration was 78.5 mg/L. About one-half of the trace-element samples had concentrations that were less than laboratory reporting limits. Only aluminum, arsenic, and selenium in spring samples, and boron and selenium in well samples, were detected at concentrations greater than surface-water standards or water-quality standards for agricultural use of groundwater. Only three organic compounds, the pesticides alachlor and atrazine and the volatile organic compound di(2-ethylhexyl) phthalate, were detected in well samples. The Escherichia coli bacteria was detected in 47 and 23 percent of samples from wells and springs, respectively. The E. coli detections included samples from three culturally significant springs, which did not meet the UMUT cultural-use standard of total absence of E. coli. Tritium and carbon-14 were the primary environmental tracers used for interpreting groundwater ages for Lopez 2 Spring and five wells (AP–1, 5000 Block, Cottonwood Spring, Goodknight, and SE Toe). Water from the AP–1 well contained a mixture of pre- and post-1950s recharge. Tritium and carbon-14 recharge ages for Lopez 2 Spring (post-1950s in age), Goodknight and SE Toe wells (pre-1950s in age), and Cottonwood Spring well (primarily pre-1950s in age) are supported by helium-4 data. The helium-4 data for the 5000 Block well are inconsistent with the tritium and carbon-14 age of pre-1950s recharge because of interference caused by high methane concentrations in the water. Springs and surficial deposits are more vulnerable to contamination from anthropogenic chemicals than deeper bedrock wells. Bedrock aquifers are vulnerable in areas where the geologic formations containing the aquifers are exposed at the land surface. Groundwater in deep bedrock aquifers is likely thousands of years old and is not currently affected by present-day land uses. Both shallow and deep groundwater are vulnerable to naturally occurring salts and minerals, such as of total dissolved solids, major ions, nitrate, and trace elements. Effects of a changing climate on water resources and other ecological characteristics of the UMUR could include changes in evapotranspiration, a decrease in snowpack, decreased aquifer recharge and flow of springs, a decrease in soil moisture, and increased occurrence of wildfires and forest mortality. Of particular interest for the UMUT are possible effects of a changing climate on medicinal and culturally important plants and springs Several information needs were identified during this study that would aid in the understanding and protection of groundwater resources on the UMUR. These include well-completion information for bedrock wells, the collection of environmental tracer data at additional wells, the addition of methane and hydrocarbon analysis to well sampling plans, and the resampling of springs and wells that were last sampled in 2002 or earlier.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 37° to 37.3564° latitude; -109.0333° to -108.2667° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nancy J. Bauch, L. Rick Arnold. 2020-02-10. Hydrogeologic characterization, groundwater chemistry, and vulnerability assessment, Ute Mountain Ute Reservation, Colorado and Utah. https://doi.org/10.3133/sir20195122

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗