USGS Science⌕ Search

USGS · sir20195035

Simulation of groundwater flow in the Brunswick Area, Georgia, for 2004 and 2015, and selected groundwater-management scenarios

Abstract

The Upper Floridan aquifer (UFA) is the principal water source for industrial and public supply in Glynn County, Georgia. Wells in active pumping centers that tap the UFA for industries near the city of Brunswick have created an upward hydraulic-head gradient in the Floridan aquifer system, which has allowed high chloride (saline) groundwater from the Fernandina permeable zone of the Lower Floridan aquifer (LFA) to migrate upward into freshwater zones. Chloride concentrations of more than 250 milligrams per liter—the State and Federal secondary drinking-water standard—have been measured in a 2-square-mile area near downtown Brunswick. An existing regional U.S. Geological Survey modular finite-difference groundwater-flow model (MODFLOW-2000) was modified using greater horizontal and vertical resolution to enable more detailed simulation of the effects of pumping in the vicinity of chloride contamination. Modifications to the regional model consisted of (1) limiting grid size to a maximum of 500 feet (ft) per side in the vicinity of the chloride plume; (2) representing the upper and lower Brunswick aquifers with distinct model layers; (3) similarly, representing upper and lower water-bearing zones of the UFA with distinct model layers in Glynn and Camden Counties, Ga.; and (4) establishing new hydraulic-property geographic zones in the UFA within Glynn County. The revised groundwater-flow model was calibrated to steady-state conditions that were assumed to exist during 2000 and 2004. The calibration and framework of the revised groundwater-flow model were documented in a separate report. For the current study, steady-state conditions were calibrated using October 2015 pumping rates in the Brunswick/Glynn County area as a 2015 Base Case. The 2015 Base Case simulation was used as the basis to evaluate seven groundwater-management scenarios in the Brunswick/Glynn County area. Seven groundwater management-scenarios were developed on the basis of short- and long-term groundwater-use projections for the UFA in the Brunswick/Glynn County area. Scenarios A and B simulated additional pumping in the upper water-bearing zone (UWBZ) of the UFA at existing public-supply wells located near a chloride plume and planned public-supply wells to be constructed north of downtown Brunswick. Scenario C simulated a shutdown at Brunswick Cellulose Inc. and Pinova Inc. and the resulting deactivation of nine production wells, with a combined total pumping of 31.3 million gallons per day (Mgal/d) for the 2015 Base Case simulation. Scenario D (three scenarios) simulated 12.5, 25, and 50 percent (designated Scenarios D1, D2, and D3) of the total pumping of 31.3 Mgal/d at Brunswick Cellulose and Pinova. The objective of Scenario D was to determine pumping rates that may reverse groundwater-flow directions toward the Brunswick Cellulose well field and potentially allow groundwater with higher chloride concentration to migrate toward nearby public-supply wells. Scenario E simulated an additional pumping of 5 Mgal/d from the UWBZ of the UFA at a recently constructed production well within the Brunswick Cellulose well field. Backward particle-tracking (MODPATH) analysis in public-supply wells located just outside the chloride plume to the north shows that predominant groundwater-flow directions are from the northeast toward the Brunswick Cellulose well field. The analysis covered 20- and 50-year periods for the 2015 Base Case and Scenario C simulations with 100 percent of backtracked particles remaining in the UWBZ and lower water-bearing zone of the UFA. Groundwater-flow directions are characterized by some vertical movement and dominant horizontal movement away from the chloride plume in the northern Brunswick area. For the 2015 Base Case simulation, the mean rate of particle movement ranged from 268 to 413 feet per year. For the Scenario C simulation, the mean rate of particle movement ranged from 89 to 182 feet per year with 50 percent of particles migrating from the chloride plume area. The rate of particle movement is influenced most by the horizontal hydraulic-head gradient in the UWBZ of the UFA. The revised groundwater-flow model is subject to the limitations documented in the original model. In addition, the values used for the specified-head boundaries in the Floridan aquifer system for the 2004 calibrated model were based on the sparse data available and were not changed for the 2015 update to the model. These model boundaries control 80 percent of the inflows and about 60 percent of the outflows. Composite-scaled sensitivities of the model parameters indicate the revised model is most sensitive to pumping rates, followed by the horizontal hydraulic conductivity in the UFA for zones along coastal Georgia.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 30.357851° to 35.000768° latitude; -85.605165° to -80.840549° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gregory S. Cherry. 2019-05-29. Simulation of groundwater flow in the Brunswick Area, Georgia, for 2004 and 2015, and selected groundwater-management scenarios. https://doi.org/10.3133/sir20195035

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗