USGS Science⌕ Search

USGS · sir20135045

Investigations of groundwater system and simulation of regional groundwater flow for North Penn Area 7 Superfund site, Montgomery County, Pennsylvania

Abstract

Groundwater in the vicinity of several industrial facilities in Upper Gwynedd Township and vicinity, Montgomery County, in southeast Pennsylvania has been shown to be contaminated with volatile organic compounds (VOCs), the most common of which is the solvent trichloroethylene (TCE). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, and water-level monitoring, and measured streamflows in and near North Penn Area 7 from fall 2000 through fall 2006 in a technical assistance study for the USEPA to develop an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. In addition, the USGS developed a groundwater-flow computer model based on the hydrogeologic framework to simulate regional groundwater flow and to estimate directions of groundwater flow and pathways of groundwater contaminants. The study area is underlain by Triassic- and Jurassic-age sandstones and shales of the Lockatong Formation and Brunswick Group in the Mesozoic Newark Basin. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form a fractured-sedimentary-rock aquifer that acts as a set of confined to partially confined layers of differing permeabilities. Depth to competent bedrock typically is less than 20 ft below land surface. The aquifer layers are recharged locally by precipitation and discharge locally to streams. The general configuration of the potentiometric surface in the aquifer is similar to topography, except in areas affected by pumping. The headwaters of Wissahickon Creek are nearby, and the stream flows southwest, parallel to strike, to bisect North Penn Area 7. Groundwater is pumped in the vicinity of North Penn Area 7 for industrial use, public supply, and residential supply. Results of field investigations by USGS at the site and results from other studies support, and are consistent with, a conceptual model of a layered leaky aquifer where the dip of the beds has a strong control on hydraulic connections in the groundwater system. Connections within and (or) parallel to bedding tend to be greater than across bedding. Transmissivities of aquifer intervals isolated by packers ranged over three orders of magnitude [from about 2.8 to 2,290 square feet per day (ft 2 /d) or 0.26 to 213 square meters per day (m 2 /d)], did not appear to differ much by mapped geologic unit, but showed some relation to depth being relatively smaller in the shallowest and deepest intervals (0 to 50 ft and more than 250 ft below land surface, respectively) compared to the intermediate depth intervals (50 to 250 ft below land surface) tested. Transmissivities estimated from multiple-observation well aquifer tests ranged from about 700 to 2,300 ft 2 /d (65 to 214 m 2 /d). Results of chemical analyses of water from isolated intervals or monitoring wells open to short sections of the aquifer show vertical differences in concentrations; chloride and silica concentrations generally were greater in shallow intervals than in deeper intervals. Chloride concentrations greater than 100 milligrams per liter (mg/L), combined with distinctive chloride/bromide ratios, indicate a different source of chloride in the western part of North Penn Area 7 than elsewhere in the site. Groundwater flow at a regional scale under steady-state conditions was simulated by use of a numerical model (MODFLOW-2000) for North Penn Area 7 with different layers representing saprolite/highly weathered rock near the surface and unweathered competent bedrock. The sedimentary formations that underlie the study area were modeled using dipping model layers for intermediate and deep zones of unweathered, fractured rock. Horizontal cell model size was 100 meters (m) by 100 meters (328 ft by 328 ft), and model layer thickness ranged from 6 m (19.7 ft) representing shallow weathered rock and saprolite up to 200 m (656 ft) representing deeper dipping bedrock. The model did not include detailed structure to account for local-scale differences in hydraulic properties, with the result that local-scale groundwater flow may not be well simulated. Additional detailed multi-well aquifer tests would be needed to establish the extent of interconnection between intervals at the local scale to address remediation of contamination at each source area. This regional groundwater-flow model was calibrated against measured groundwater levels (1996, 2000, and 2005) and base flow estimated from selected streamflow measurements by use of nonlinear-regression parameter-estimation algorithms to determine hydraulic conductivity and anisotropy of hydraulic conductivity, streambed hydraulic conductivity, and recharge during calibration periods. Results of the simulation using the calibrated regional model indicate that the aquifer appears to be anisotropic where hydraulic conductivity is greatest parallel to the orientation of bedding of the formations underlying the area and least in the cross-bed direction. The maximum hydraulic conductivity is aligned with the average regional strike of the formations, which is “subhorizontal” in the model because the altitudes of the beds and model cells vary in the strike, as well as dip, direction. Estimated subhorizontal hydraulic conductivities (in strike direction parallel to dipping beds) range from 0.001 to 1.67 meters per day (0.0032 to 5.5 feet per day). The ratio of minimum (dip direction) to maximum (strike direction) subhorizontal hydraulic conductivity ranges from 1/3.1 to 1/8.6, and the ratio of vertical to horizontal hydraulic conductivity ranges from 1/1 to 1/478. However, limited available field data precluded rigorous calibration of vertical anisotropy in the model. Estimated recharge rates corresponding to calibration periods in 1996, 2000, and 2005 are 150, 109, and 124 millimeters per year (5.9, 4.3, and 4.9 inches per year), respectively. The calibrated groundwater-flow model was used to simulate groundwater flow under steady-state conditions during periods of relatively high withdrawals (pumpage) (1990) and relatively low withdrawals (2000 and 2005). Groundwater-flow paths originating from recharge areas near known areas of soil contamination (sources) were simulated. Pumped industrial and production wells captured more groundwater from several of these sources during 1990 than after 1990 when pumping declined or ceased and greater amounts of contaminated groundwater moved away from North Penn Area 7 Superfund site to surrounding areas. Uncertainty in simulated groundwater-flow paths from contaminant sources and contributing areas, resulting from uncertainty in estimated hydraulic properties of the model, was illustrated through Monte Carlo simulations. The effect of uncertainty in the vertical anisotropy was not included in the Monte Carlo simulations. Contributing areas indicating the general configuration of groundwater flow towards production well MG-202 (L-22) in the study area also were simulated for the different time periods; as simulated, the flow paths do not pass through any identified contaminant source in North Penn Area 7. However, contributing areas to wells, such as MG-202, located near many pumped wells are particularly complex and, in some cases, include areas that contribute flow to streams that subsequently recharge the aquifer through stream loss. In these cases, water-quality constituents, including contaminants that are present in surface water may be drawn into the aquifer to nearby pumped wells. Results of a simulated shutdown of well MG-202 under steady-state 2005 conditions showed that the area contributing recharge for nearby production well MG-76 (L-17), when MG-202 is not pumping, shifts downstream and is similar to the area contributing recharge for MG-202 when both wells are pumping. Concentrations of constituents in groundwater samples collected in fall 2005 or spring 2006 were compared to simulated groundwater-flow paths for the year 2005 to provide a qualitative assessment of model results. The observed spatial distribution of selected constituents, including TCE, CFC-11, and CFC-113 in groundwater in 2005 and the chloride/bromide mass ratios in 2006, generally were consistent with the model results of the simulated 2005 groundwater-flow paths at North Penn Area 7, indicating the presence of several separate sources of contaminants within North Penn Area 7.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 40.17939793281656° to 40.23079086353824° latitude; -75.33050537109375° to -75.23162841796875° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lisa A. Senior, Daniel J. Goode. 2013. Investigations of groundwater system and simulation of regional groundwater flow for North Penn Area 7 Superfund site, Montgomery County, Pennsylvania. https://doi.org/10.3133/sir20135045

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗