USGS Science⌕ Search

USGS · sir20125128

Surface-water salinity in the Gunnison River Basin, Colorado, water years 1989 through 2007

Abstract

Elevated levels of dissolved solids in water (salinity) can result in numerous and costly issues for agricultural, industrial, and municipal water users. The Colorado River Basin Salinity Control Act of 1974 (Public Law 93-320) authorized planning and construction of salinity-control projects in the Colorado River Basin. One of the first projects was the Lower Gunnison Unit, a project to mitigate salinity in the Lower Gunnison and Uncompahgre River Basins. In cooperation with the Bureau of Reclamation (USBR), the U.S. Geological Survey conducted a study to quantify changes in salinity in the Gunnison River Basin. Trends in salinity concentration and load during the period water years (WY) 1989 through 2004 (1989-2004) were determined for 15 selected streamflow-gaging stations in the Gunnison River Basin. Additionally, trends in salinity concentration and load during the period WY1989 through 2007 (1989-2007) were determined for 5 of the 15 sites for which sufficient data were available. Trend results also were used to identify regions in the Lower Gunnison River Basin (downstream from the Gunnison Tunnel) where the largest changes in salinity loads occur. Additional sources of salinity, including residential development (urbanization), changes in land cover, and natural sources, were estimated within the context of the trend results. The trend results and salinity loads estimated from trends testing also were compared to USBR and Natural Resources Conservation Service (NRCS) estimates of off-farm and on-farm salinity reduction from salinity-control projects in the basin. Finally, salinity from six additional sites in basins that are not affected by irrigated agriculture or urbanization was monitored from WY 2008 to 2010 to quantify what portion of salinity may be from nonagricultural or natural sources. In the Upper Gunnison area, which refers to Gunnison River Basin above the site located on the Gunnison River below the Gunnison Tunnel, estimated mean annual salinity load was 110,000 tons during WY 1989-2004. Analysis of both study periods (WY 1989-2004 and WY 1989-2007) showed an initial decrease in salinity load with a minimum in 1997. The net change over either study period was only significant during WY 1989-2007. Salinity load significantly decreased at the Gunnison River near Delta by 179,000 tons during WY 1989-2004. Just downstream, the Uncompahgre River enters the Gunnison River where there also was a highly significant decrease in salinity load of 55,500 tons. The site that is located at the mouth of the study area is the Gunnison River near Grand Junction where the decrease was the largest. Salinity loads decreased by 247,000 tons during WY 1989-2004 at this site though the decrease attenuated by 2007 and the net change was a decrease of 207,000 tons. The trend results presented in this study indicate that the effect of urbanization on salinity loads is difficult to discern from the effects of irrigated agriculture and that natural sources contribute a fraction of the total salinity load for the entire basin. Based on the calculated yields and geology, 23-63 percent of the estimated annual salinity load was from natural sources at the Gunnison River near Grand Junction during WY 1989-2007. The largest changes in salinity load occurred at the Gunnison River near Grand Junction as well as the two sites located in Delta: the Gunnison River at Delta and the Uncompahgre River at Delta. Those three sites, especially the two sites at Delta, were the most affected by irrigated agriculture, which was observed in the estimated mean annual loads. Irrigated acreage, especially acreage underlain by Mancos Shale, is the target of salinity-control projects intended to decrease salinity loads. The NRCS and the USBR have done the majority of salinity control work in the Lower Gunnison area of the Gunnison River Basin, and the focus has been in the Uncompahgre River Basin and in portions of the Lower Gunnison River Basin (downstream from the Gunnison Tunnel). According to the estimates from the USBR and NRCS, salinity-control projects may be responsible for a reduction of 117,300 tons of salinity as of 2004 and 142,000 tons as of 2007 at the Gunnison River near Grand Junction, Colo. (streamflow-gaging station 09152500). USBR and NRCS estimates account for all but 130,000 tons in 2004 and 65,000 tons in 2007 of salinity load reduction. The additional reduction could be a reduction in natural salt loading to the streams because of land-cover changes during the study period. It is possible also that the USBR and NRCS have underestimated changes in salinity loads as a result of the implementation of salinity-control projects.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 37.5° to 39.5° latitude; -109.5° to -106.5° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Keelin R. Schaffrath. 2012. Surface-water salinity in the Gunnison River Basin, Colorado, water years 1989 through 2007. https://doi.org/10.3133/sir20125128

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗