USGS Science⌕ Search

USGS · sir20075049

Recharge area, base-flow and quick-flow discharge rates and ages, and general water quality of Big Spring in Carter County, Missouri, 2000-04

Abstract

Exploration for lead deposits has occurred in a mature karst area of southeast Missouri that is highly valued for its scenic beauty and recreational opportunities. The area contains the two largest springs in Missouri (Big Spring and Greer Spring), both of which flow into federally designated scenic rivers. Concerns about potential mining effects on the area ground water and aquatic biota prompted an investigation of Big Spring. Water-level measurements made during 2000 helped define the recharge area of Big Spring, Greer Spring, Mammoth Spring, and Boze Mill Spring. The data infer two distinct potentiometric surfaces. The shallow potentiometric surface, where the depth-to-water is less than about 250 feet, tends to mimic topographic features and is strongly controlled by streams. The deep potentiometric surface, where the depth-to-water is greater than about 250 feet represents ground-water hydraulic heads within the more mature karst areas. A highly permeable zone extends about 20 mile west of Big Spring toward the upper Hurricane Creek Basin. Deeper flowing water in the Big Spring recharge area is directed toward this permeable zone. The estimated sizes of the spring recharge areas are 426 square miles for Big Spring, 352 square miles for Greer Spring, 290 square miles for Mammoth Spring, and 54 square miles for Boze Mill Spring. A discharge accumulation curve using Big Spring daily mean discharge data shows no substantial change in the discharge pattern of Big Spring during the period of record (water years 1922 through 2004). The extended periods when the spring flow deviated from the trend line can be attributed to prolonged departures from normal precipitation. The maximum possible instantaneous flow from Big Spring has not been adequately defined because of backwater effects from the Current River during high-flow conditions. Physical constraints within the spring conduit system may restrict its maximum flow. The largest discharge measured at Big Spring during the period of record (water years 1922 through 2004) was 1,170 cubic feet per second on December 7, 1982. The daily mean water temperature of Big Spring was monitored during water years 2001 through 2004 and showed little variability, ranging from 13 to 15° C (degree Celsius). Water temperatures generally vary less than 1° C throughout the year. The warmest temperatures occur during October and November and decrease until April, indicating Big Spring water temperature does show a slight seasonal variation. The use of the traditional hydrograph separation program HYSEP to determine the base flow and quick flow or runoff components at Big Spring failed to yield base-flow and quick-flow discharge curves that matched observations of spring characteristics. Big Spring discharge data were used in combination with specific conductance data to develop an improved hydrograph separation method for the spring. The estimated annual mean quick flow ranged from 15 to 48 cubic feet per second for the HYSEP analysis and ranged from 26 to 154 cubic feet per second for the discharge and specific conductance method for water years 2001 to 2004. Using the discharge and specific conductance method, the estimated base-flow component rises abruptly as the spring hydrograph rises, attains a peak value on the same day as the discharge peak, and then declines abruptly from its peak value. Several days later, base flow begins to increase again at an approximately linear trend, coinciding with the time at which the percentage of quick flow has reached a maximum after each recharge-induced discharge peak. The interval between the discharge peak and the peak in percentage quick flow ranges from 8 to 11 days for seven hydrograph peaks, consistent with quick-flow traveltime estimates by dye-trace tests from the mature karst Hurricane Creek Basin in the central part of the recharge area. Concentrations of environmental tracers chlorofluorocarbons (CFCs: CFC-11, CFC-12, CFC-113), and sulfur hexafluoride in discharge from Big Spring vary approximately linearly with percent quick flow from about 5 to 45 percent of discharge. Linear extrapolation to 100 percent quick flow implies CFC and SF 6 concentrations nearly identical to those in the 2002 atmosphere and indicates a modern age for the quick-flow component. Tracer concentrations for less than about 5 percent quick flow are increasingly lower than those expected from linear extrapolation to zero percent quick flow, indicating that the reservoir of older water in the Big Spring watershed may be a series of water mixtures with piston-flow ages greater than those obtained by extrapolation to zero percent quick flow. Each sample point with a low percentage of quick flow (less than 5 percent) may be a unique mixture. Environmental tracer data from Big Spring plot intermediate to the simple binary mixing of modern and old, pre-tracer water and results from the exponential mixture model. The mean ages of waters in the base-flow component approximately range from 30 to 200 years. The mean age of the base-flow component is youngest (30 to 40 years) in samples containing the highest quick-flow component (45 percent quick flow) and increases to 200 years or more as the fraction of quick flow decreases to less than 5 percent. Tritium data are consistent with a model of dilution of a modern component with an old, pre-tracer component and indicates that the old fraction is mostly pre-1960s in age with mean residence time of more than several hundred years. All of the samples from Big Spring and Greer Spring have water temperatures warmer than their nitrogen-argon recharge temperature, which range from approximately 10.5 to 14° C, suggesting recharge to the Big Spring watershed occurs primarily in late winter to early spring. The water temperatures at Big Spring are consistent with relatively shallow circulation (less than about 600 feet), and the water does not appear to be warmed by deep circulation along a geothermal gradient. Specific conductance values and concentrations of most inorganic constituents in water samples from Big Spring generally decrease with increasing discharge because of dilution with quick-flow water of lower ionic strength. Concentrations of some constituents such as chloride and nitrite plus nitrate, and fecal coliform densities, however, did not decrease with increasing discharge, indicating that quick flow probably is a more important source of these constituents compared to base flow. Water samples from Big Spring plot along the line of dolomite dissolution by carbonic acid, are at equilibrium with dolomite and calcite, and have a molar ratio of Ca:Mg of near 1, indicating dissolution of the mineral dolomite as the primary control on concentrations of calcium, magnesium, and bicarbonate. The flux of calcium and magnesium from Big Spring represents the dissolution of about 1,950 cubic feet of dolomite per day. The suspended sediment load of Big Spring was estimated to range from about 1 to about 70 tons per day, and the sediment load during base-flow periods ranged from about 1 to about 7 tons per day.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 36.8109° to 37.1008° latitude; -91.2245° to -90.6596° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jeffrey L. Imes, Niel Plummer, Michael J. Kleeschulte, John G. Schumacher. 2007. Recharge area, base-flow and quick-flow discharge rates and ages, and general water quality of Big Spring in Carter County, Missouri, 2000-04. https://doi.org/10.3133/sir20075049

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗