USGS ScienceSearch

USGS · sir20065014

Borehole geophysical logging and aquifer-isolation tests conducted in well MG-1693 at North Penn Area 5 Superfund Site near Colmar, Montgomery County, Pennsylvania

Abstract

Borehole geophysical logging and aquifer-isolation (packer) tests were conducted in well MG-1693 (NP-87) at the North Penn Area 5 Superfund Site near Colmar, Montgomery County, Pa. Objectives of the study were to identify the depth and yield of water-bearing zones, occurrence of vertical borehole flow, and effects of pumping on water levels in nearby wells. Caliper, natural-gamma, single-point-resistance, fluidtemperature, fluid-resistivity, heatpulse-flowmeter, and borehole-video logs were collected. Vertical borehole-fluid movement direction and rate were measured under nonpumping conditions. The suite of logs was used to locate water-bearing fractures, determine zones of vertical borehole-fluid movement, and select depths to set packers. Aquifer-isolation tests were conducted to sample discrete intervals and to determine specific capacities of water-bearing zones and effects of pumping individual zones on water levels in two nearby monitor wells. Specific capacities of isolated zones during aquifer-isolation tests ranged from 0.03 to 3.09 (gal/min)/ft (gallons per minute per foot). Fractures identified by borehole geophysical methods as water-producing or water-receiving zones produced water when isolated and pumped. Water enters the borehole primarily through high-angle fractures at 416 to 435 ft bls (feet below land surface) and 129 to 136 ft bls. Water exits the borehole through a high-angle fracture at 104 to 107 ft bls, a broken casing joint at 82 ft bls, and sometimes as artesian flow through the top of the well. Thirteen intervals were selected for aquifer-isolation testing, using a straddle-packer assembly. The specific capacity of interval 1 was 2.09 (gal/min)/ft. The specific capacities of intervals 2, 3, and 4 were similar—0.27, 0.30, and 0.29 (gal/min)/ft, respectively. The specific capacities of intervals 5, 6, 7, 8, and 10 were similar—0.03, 0.04, 0.09, 0.09, and 0.04 (gal/min)/ft, respectively. Intervals 9, 11, and 12 each showed a strong hydraulic connection outside the borehole with intervals above and below the isolated interval. The specific capacities of intervals 9, 11, 12, and 13 were similar—2.12, 2.17, 3.09, and 3.08 (gal/min)/ft, respectively. The aquifer-isolation tests indicate that wells MG-1693 (NP-87) and MG-924 (NP-21) are connected primarily through the high-angle fracture from 416 to 435 ft bls. Pumping in either of these wells directly impacts the other well, allowing the pumped well to draw from water-bearing zones in the nonpumped well that are not present in or are not connected directly to the pumped well. The two boreholes act as a single, U-shaped well. The aquifer-isolation tests also show that the lower zones in well MG-1693 (NP-87) are a major source of hydraulic head in well MG-1661 (W-13) through the broken casing joint at 82 ft bls. Water moving upward from the lower intervals in well MG-1693 (NP-87) exits the borehole through the broken casing joint, moves upward outside the borehole, possibly around and (or) through a poor or damaged casing seal, and through the weathered zone above bedrock to well MG-1661 (W-13). Samples for volatile organic compounds (VOCs) were collected in nine isolated intervals. Six compounds were detected (1,1-dichloroethane, 1,1-dichloroethene, cis-1,2-dichloroethene, toluene, 1,1,1-trichloroethane, and trichloroethene (TCE)), and TCE was found in all nine isolated intervals. Intervals 4 (124-149 ft bls) and 6 (277-302 ft bls) had the highest total concentration of VOCs (6.66 and 6.2 micrograms per liter, respectively). Intervals 1 (68-93 ft bls) and 4 each had five compounds detected, which was the highest number of compounds detected. Interval 5 (252-277 ft bls) had the lowest total concentration of VOCs (0.08 microgram per liter) and the least number of VOCs detected (one). Detected compounds were not evenly distributed throughout the intervals. Contaminants were found in shallow, intermediate, and deep intervals and were associated with high-angle fractures and rough areas that showed no distinct fractures.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 40.333333333333336° to 40.5° latitude; -75.5° to -75.33333333333333° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Philip H. Bird. 2006. Borehole geophysical logging and aquifer-isolation tests conducted in well MG-1693 at North Penn Area 5 Superfund Site near Colmar, Montgomery County, Pennsylvania. https://doi.org/10.3133/sir20065014

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Monitoring recreation on federally managed lands and waters—Aspects of visitor use

Federally managed public lands and waters receive around 1 billion recreational visits each year. Data on these visitors can aid in guiding policy decisions, managing resources effectively, and communicating the economic contributions of lands and waters. This report explores the methods used by agencies to collect data on aspects of recreational visitor use to Federal lands and waters (apart from visitation numbers, which are the focus of a companion publication). Aspects of recreational visitor use include visitor demographics, recreational activity participation, visitor satisfaction, visitor attitudes and experiences, trip characteristics, and economic contributions. We review practices used to understand aspects of visitor use across seven Federal agencies, revealing similarities such as the use of visitor intercept surveys and coverage of similar topic areas, and differences in how survey programs are operationalized and how specific questions on visitor surveys are worded. We also evaluate emerging technologies, such as geolocated social media and mobile device location data, for their potential to aid in understanding aspects of visitor use. This report concludes with potential opportunities to enhance data collection and coordination, ensuring cost-effective data collection and informed decision making.

Scientific Investigations Report

Evaluation of best management practices at an edge-of-field site in the Eagle Creek watershed, Ohio, 2012–20

In 2010, the U.S. Geological Survey worked in partnership with the Great Lakes Restoration Initiative and the Natural Resources Conservation Service to identify farm fields in priority watersheds—watersheds critically important to Great Lake health. Intensive best management practices were implemented in five States to test the efficacy of best management practices, also referred to as agricultural conservation practices, to reduce sediment and nutrient runoff on agricultural fields. These fields were chosen as representatives of the priority watersheds because their farming practices and geographical conditions were common among farms in those watersheds. A farm site located near Findlay, Ohio, in the Eagle Creek watershed used two conservation practices, cover crop (Natural Resources Conservation Service practice standard 340) and variable rate technology (VRT; Natural Resources Conservation Service practice standard 590), which represent common practices in the Maumee priority watershed. This study monitored surface runoff and subsurface tile runoff at the Eagle Creek watershed site. The effects of cover crop and VRT nutrient application on sediment and nutrient runoff were assessed from October 2012 to September 2020. Cover crops were applied in fall of 2016, 2017, and 2018, coinciding with VRT applications. The following parameters were analyzed as part of the study: runoff discharge; peak discharge; and concentrations and loads of total phosphorus, particulate phosphorus, dissolved reactive phosphorus, and suspended sediment. High peak runoff events disproportionally affected nutrient concentrations and loads in runoff. A threshold of the 85th percentile of the peak discharge was chosen to assess the effect of cover crop and VRT nutrient application on nutrient mitigation at each gage. Runoff events below the 85th percentile were considered small, and runoff events over the 85th percentile were considered large. Concentrations from collected water-quality samples were used for the analysis; estimated concentrations were excluded from the statistical evaluation. All surface runoff parameters during small runoff events, except surface runoff volume, were significantly lower in the period with cover crops and VRT implementation. Contrarily, subsurface runoff parameters during small events were not statistically different between the periods with and without cover crops and VRT implementation. Surface and subsurface parameters during large events were also not statistically different between the periods with and without cover crops and VRT implementation. These results indicate cover crops and VRT may improve water quality during small runoff events, but additional best management practices that mitigate large runoff events may lead to greater water-quality improvement given the contribution of large events to overall losses.

Ohio

Continuous monitoring and temporal variability of fluorescence of dissolved organic matter in karst groundwater of the Edwards aquifer, south-central Texas, 2019–24

Widespread urbanization on the Edwards aquifer recharge zone in south-central Texas has prompted the development of new approaches and tools for evaluating the current and future status of water quality in the San Antonio and Barton Springs segments of the Edwards aquifer. The U.S. Geological Survey, in cooperation with the San Antonio Water System and the City of Austin, applied continuous monitoring of fluorescence of dissolved organic matter (fDOM) to characterize the sources and transport of dissolved organic matter and associated constituents in the Edwards aquifer. Continuous fDOM time-series data were adjusted using empirically derived temperature, turbidity, and inner-filter-effect correction factors prior to analysis and interpretation. Fully corrected fDOM time-series data from the study sites were evaluated for short- and long-term temporal variability in fDOM in the context of the hydrologic and climatic conditions that occurred during the 5-year study period to understand vulnerability of the aquifer to potential contaminants in recharge. Study results indicate that fDOM is an effective proxy for dissolved organic carbon that, in turn, is indicative of the influx of recent surface water and associated contaminants, and thus, aquifer vulnerability to those contaminants. Although other continuously monitored water-quality parameters provide insights into changes in water quality in response to varying hydrologic conditions, the quantitative relation between fDOM and dissolved organic carbon directly indicates the timing and magnitude of pulses of organic constituents derived from the land surface, whereas other water-quality parameters do not.

Texas