USGS ScienceSearch

USGS · pp1885G

Evaluation of natural and anthropogenic (human-made) hexavalent chromium

Abstract

Hexavalent chromium, Cr(VI), was released between 1952 and 1964 from the Pacific Gas and Electric Company (PG&E) Hinkley compressor station, in the Mojave Desert about 80 miles northeast of Los Angeles, California. Geologic, geochemical, and hydrologic data from more than 100 wells collected between March 2015 and November 2017 were interpreted using a summative-scale analysis to define the extent of anthropogenic (human-made) Cr(VI) in groundwater. The summative scale consisted of eight questions requiring binary (yes or no) answers for each sampled well. The questions were intended to (1) provide a transparent framework for data interpretation in which all stakeholders participated; (2) provide unbiased interpretation of data traceable to numerical measurements; (3) provide a framework that enabled geologic, geochemical, and hydrologic data to be considered collectively; and (4) consolidate different types of data into a simple, easy-to-understand interpretation. When data from each well are scored using questions and metrics within the summative scale, all stakeholders would score each well the same way and would draw the same summative-scale Cr(VI) plume extent. The areal extent of the summative-scale Cr(VI) plume was 5.5 square miles (mi 2 ); this is larger than the 2.2-mi 2 extent of the October–December 2015 (Q4 2015) regulatory Cr(VI) plume but smaller than the 8.3-mi2 maximum mapped extent of Cr(VI) greater than the interim regulatory Cr(VI) background value of 3.1 micrograms per liter (μg/L). The summative-scale Cr(VI) plume is within the area covered by the PG&E monitoring well network and lies within “Mojave-type” deposits composed of low-chromium stream and near-shore lake deposits sourced from the Mojave River. The summative-scale Cr(VI) plume included all shallow wells within the footprint of the Q4 2015 regulatory Cr(VI) plume, but summative-scale scores indicate that anthropogenic Cr(VI) was not present in several wells within the footprint of the regulatory Cr(VI) plume that were screened within the deep zone of the upper aquifer. The summative-scale Cr(VI) plume extent was consistent with mineralogic and geochemical data collected as part of this study that were not used within the summative-scale analysis. Data from wells outside the summative-scale Cr(VI) plume collected for regulatory purposes from April 2017 through March 2018 were used to estimate Cr(VI) background concentrations as the upper 95-percent tolerance limit (UTL 95 ) in different parts of Hinkley and Water Valleys. The UTL 95 values were calculated using the computer program ProUCL 5.1 and are suitable for use by regulatory agencies in support of (1) updating the regulatory Cr(VI) plume extent and management of Cr(VI) near the plume margins, (2) establishing cleanup goals for Cr(VI) within the updated regulatory Cr(VI) plume, and (3) identifying unusual Cr(VI) concentrations outside the regulatory Cr(VI) plume. The nonparametric UTL 95 values for wells screened in Mojave-type deposits in the eastern, western, and northern subareas of Hinkley Valley were 3.7, 3.9, and 4.0 μg/L, respectively. The normal UTL 95 values for wells screened in undifferentiated, unconsolidated deposits in the eastern and western subareas and the northern subarea upgradient from the Mount General fault were 2.8, 3.8, and 4.8 μg/L, respectively. An overall normal UTL 95 value of 3.8 μg/L was calculated for undifferentiated, unconsolidated deposits in these areas. This value is similar to the overall nonparametric UTL 95 value of 3.9 μg/L calculated for Mojave-type deposits and similar to the maximum Cr(VI) concentration of older groundwater in contact with Mojave-type deposits of 3.6 μg/L. The provenance of most PG&E monitoring wells is not precisely known, and the UTL 95 values for wells screened in undifferentiated, unconsolidated deposits in the different subareas may be more widely applicable for regulatory purposes than the UTL 95 values for Mojave-type deposits. The UTL 95 value of 2.8 μg/L for wells screened in undifferentiated, unconsolidated deposits in the eastern subarea is important for plume management because most of the summative-scale Cr(VI) plume is within the eastern subarea. A UTL 95 value of 5.8 μg/L was calculated for older (pre-1952) groundwater associated with mudflat/playa deposits in the eastern subarea near Mount General. A UTL 95 value of 2.3 μg/L was calculated for Mojave-type deposits within the Cr(VI) plume downgradient from the Hinkley compressor station after regulatory updates. This lower value is consistent with neutral to slightly alkaline, younger (post-1952) groundwater within coarse-textured, low-chromium Mojave-type deposits in this area and may be a suitable metric for Cr(VI) cleanup goals. The UTL 95 value of 4.8 μg/L for wells screened in undifferentiated, unconsolidated deposits in the northern subarea upgradient from the Mount General fault provides for possible increases in Cr(VI) concentrations if water levels continue to decline. Downgradient from the Q4 2015 regulatory Cr(VI) plume and the summative-scale Cr(VI) plume, UTL 95 values of 9.0 and 6.4 μg/L were calculated for wells screened in undifferentiated, unconsolidated deposits in the northern subarea downgradient from the Mount General fault and for Water Valley, respectively, consistent with different geologic and geochemical conditions in these areas. The UTL 95 values calculated as part of this study provide scientifically defensible estimates of background Cr(VI) concentrations that differ with local geologic, geochemical, and hydrologic conditions in Hinkley and Water Valleys. The regulatory Cr(VI) plume extent can be updated on the basis of these values. The summative-scale Cr(VI) plume extent may contain wells having anthropogenic Cr(VI) concentrations less than the UTL 95 values for their respective subareas that may not require regulatory attention, and an updated regulatory Cr(VI) plume extent may be less than the summative-scale Cr(VI) plume extent. The UTL 95 values are not background Cr(VI) concentrations for regulatory purposes, and the authority to establish regulatory values resides solely with the Lahontan Regional Water Quality Control Board.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 34.25° to 35.25° latitude; -117.75° to -116° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John A. Izbicki, John G. Warden, Krishangi D. Groover, Whitney A. Seymour. 2023-04-25. Evaluation of natural and anthropogenic (human-made) hexavalent chromium. https://doi.org/10.3133/pp1885g

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Resurvey of the Marble Canyon and Bridge Canyon dam sites in Grand Canyon National Park—Changes in sediment storage and evidence supporting the occurrence of bedrock incision through the mid-20th century

The Bureau of Reclamation developed an extensive plan for a network of dams, water tunnels, and hydropower plants in and around Grand Canyon, Arizona, in the 1940s through 1960s. The two largest of these planned dams were the Marble Canyon and Bridge Canyon Dams on the Colorado River. Though these dams were ultimately never built, Reclamation conducted extensive topographic, bathymetric, and subsurface exploration work at the sites proposed for these dams in the 1940s and 1950s. Resurveys of these dam sites were conducted between 1998 and 2021 to determine the changes in sediment storage at these dam sites caused by the upstream construction and operation of Glen Canyon Dam and by the recession of Lake Mead, the reservoir impounded by Hoover Dam. The resurveys of the Marble Canyon dam sites indicate that the post-1950s changes in sediment storage at these dam sites are broadly consistent with flux-based estimates of voluminous sand erosion from Marble Canyon since the 1963 closure of Glen Canyon Dam. These resurveys also suggest that the pre-dam longitudinal variation in sediment thickness over bedrock played a key role in determining the locations of the sand erosion induced by Glen Canyon Dam; more sand eroded from locations where more sand was present in the 1950s. The resurvey of the Bridge Canyon dam sites indicates that the Colorado River’s incision of the Lake Mead delta is regulated both by bed-sediment grain size and downstream hydraulic controls. Finally, analyses of bed-sediment thickness and sedimentological data at the dam sites, and observations of bed scour and gravel transport, suggest that sufficient bedrock was exposed to allow bedrock incision during commonly recurring pre-dam snowmelt floods that entrained small boulders into transport.

Arizona

The eruptive behavior of distributed volcanism forming low shield edifices—A case study of Sentinel-Arlington volcanic field, U.S.A.

Distributed volcanic fields are present in various tectonic settings worldwide, and their characteristics reflect differing influences from magmatic and tectonic processes. In the southwestern United States alone, there are 37 Quaternary distributed volcanic fields. After the primary period of extensional tectonics in the southern Basin and Range 15–5 million years ago, the Sentinel-Arlington volcanic field developed in southwestern Arizona between 4 and 1 million years ago. The Sentinel-Arlington volcanic field consists primarily of low relief shield volcanoes, a type of distributed volcanism with poorly understood temporal evolution. The Sentinel-Arlington volcanic field is less than 200 kilometers (km) from the Colorado Plateau, Gulf of California, and southern San Andreas Fault system. This work identifies and examines controls on the emplacement of the Sentinel-Arlington volcanic field by documenting shallow and surficial structures as well as eruption characteristics and style through time. The Sentinel-Arlington volcanic field consists of 21 volcanoes with a total of 33 vents over an area of about 770 square kilometers (km 2 ). The prominence of low relief shield volcanoes may be explained by ascent of basaltic magmas through thin Basin and Range crust, without much crustal contamination, and low viscosities common to mafic compositions. Typical eruption characteristics involve the construction of low relief shield volcanoes followed by Strombolian fissure eruptions at the summits or near-summit medial areas that produce scoria lapilli, which may weld to form agglomerate. The total lifetime erupted volume of about 4.3 cubic kilometers (km 3 ) represents an average eruptive flux of approximately 2x10 -3 km 3 per thousand years (k.y.). This erupted volume is low relative to Neogene basaltic intraplate distributed volcanic fields worldwide, which typically range from 10 -3 to 1 km 3 k.y. -1 . Sentinel-Arlington volcanic field eruptions were likely triggered by intermittent rejuvenation of transient magmatic zones that exist in thinned crust. Instantaneous flux from point sources feeding the lava flows is estimated to be on the order of 10 -1 to 10 cubic meters per second.

Arizona

Capitalization of positional (Lower/Middle/Upper) and temporal (Early/Middle/Late) adjectives in the names of formal chronostratigraphic and geochronologic units of the Phanerozoic

Many authors are understandably confused about the capitalization of the words “lower,” “middle,” “upper,” “early,” and “late.” Where these words are used simply as descriptive adjectives, they should be in lowercase; where they form the first word of a formal chronostratigraphic or geochronologic unit name, they should be in uppercase.

Professional Paper