Field observations, preliminary model analysis, and aquifer thermal efficiency

Abstract

In May 1980, the University of Minnesota began a project to evaluate the feasibility of storing heated (150 degrees Celsius (°C) water in the deep (180 to 240 meters (m)) Franconia-Ironton-Galesville aquifer and later recovering it for space heating. The Aquifer Thermal-Energy Storage (ATES) system was a doublet-well design in which the injection and withdrawal wells were spaced approximately 250 m apart. High-temperature water from the university's steam-generation facilities supplied heat for injection. Water was pumped from one of the wells through a heat exchanger, where heat was added or removed. Water then was injected back into the aquifer through the other well. The experimental plan for testing the ATES system consisted of a series of short-term hot-water injection, storage, and withdrawal cycles. Each cycle was 24 days long, and each injection, storage, and withdrawal step of the cycle was 8 days. The Franconia-Ironton-Galesville aquifer is a consolidated sandstone, approximately 60 m thick, the top of which is approximately 180 m below the land surface. It is confined above by the St. Lawrence Formation a dolomitic sandstone 8 m thick and below by the Eau Claire Formation a shale 30 m thick. Initial hydraulic testing with inflatable packers indicated that the aquifer has four hydraulic zones with distinctly different values of relative horizontal hydraulic conductivity. The thickness of each zone was determined by correlating data from geophysical logs, core samples, and the inflatable-packer tests. A comprehensive network for data collection, storage, and analysis was designed to monitor temperature and pressure changes during the ATES test cycles. A total of 22 pressure transducers and 56 thermocouples monitored pressures and temperatures in the aquifer and in the upper and lower confining units. Temperature and pressure measurements were collected in observation well nests at distances of approximately 7 and 14 m from the production wells. All pressure and temperature data were transmitted through buried cables to a central data logger, where the measurements were viewed independently or stored on computer magnetic tape for later analysis. Interactive computer programs were available to display data stored on magnetic tapes as individual measurements or as plots of pressure and temperature versus time. Analyses of step-drawdown and constant-discharge aquifer tests indicate that the Franconia-Ironton-Galesville aquifer is anisotropic in the horizontal plane. Major and minor transmissivities are 101.5 and 44.6 m 2 /d (square meters per day), respectively, for the Ironton and Galesville Sandstones and 40.0 and 24.0 m 2 /d, respectively, for the upper part of the Franconia Formation. The average transmissivity of the entire Franconia-Ironton-Galesville aquifer is about 98 m 2 /d. Effective porosity ranges from 0.25 to 0.31, and the average storage coefficient is 4.5x10 -5 . Two computer models were constructed to simulate the movement of ground water and heat. The first was a nonisothermal, isotropic, single-phase, radial, ground-water flow and thermal-energy-transport model that was constructed to examine the sensitivity of model results to various hydraulic and thermal properties. The model also was used to study the potential for buoyancy flow within the aquifer and the effect of various cyclic injection and withdrawal schemes on the relative thermal efficiency of the aquifer. The second model was a threedimensional ground-water flow and thermal-energy-transport model that was constructed to incorporate the anisotropy of the aquifer. In the first model, the sensitivity analysis assumed 8 days of injection of 150°C water at 18.9 liters per second (L/s), 8 days of storage, and 8 days of withdrawal of hot water at 18.9 L/s. The analysis indicates that, for practical ranges of hydraulic and thermal properties, the ratio of horizontal to vertical hydraulic conductivity is the least important property and thermal dispersivity is the most important property used to compute temperature and aquifer thermal efficiency. Buoyancy flow was examined for several values of hydraulic conductivity and ratios of horizontal to vertical hydraulic conductivities. For the assumed base values of hydraulic and thermal properties, buoyancy flow was negligible. The greatest simulated buoyancy flow resulted from simulations in which horizontal hydraulic conductivity was increased to ten times the base value and in which the vertical hydraulic conductivity was set equal to the horizontal hydraulic conductivity. The effects of various injection and withdrawal rates and durations on computed values of aquifer relative-thermal efficiency and final well-bore temperature were studied for five 1-year hypothetical test cycles of injection and withdrawal. The least efficient scheme was 8 months injection of 150°C water at 18.9 L/s and 4 months of withdrawal of hot water at 18.9 L/s. The most efficient scheme was obtained with 6 months of injection of 150°C water at 18.9 L/s and 6 months of withdrawal of hot water at 37.8 L/s. The hypothetical simulations indicate that the calibrated model of the doublet-well system would be a valuable tool for use by the university in selecting a highly efficient system operation. In the second model, analytical solutions of anisotropic hydraulic flow around the doublet-well system were obtained to provide fluid-flux boundary conditions around the heat-injection well in three dimensions. This information simplified simulation of the doublet-well system because only the heat injection well needed to be simulated. This second model was calibrated with data from an 8-day ambienttemperature injection test at 18.9 L/s. Boundary-flux conditions were examined for nonisothermal conditions by simulating 8 days of injection of 150°C water at 18.9 L/s. Results of simulations using both models indicate that the fluxboundary conditions are adequate for simulations of short-term heatinjection testing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R. T. Miller, G. N. Delin. 1993. Field observations, preliminary model analysis, and aquifer thermal efficiency. https://doi.org/10.3133/pp1530a

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Resurvey of the Marble Canyon and Bridge Canyon dam sites in Grand Canyon National Park—Changes in sediment storage and evidence supporting the occurrence of bedrock incision through the mid-20th century

The Bureau of Reclamation developed an extensive plan for a network of dams, water tunnels, and hydropower plants in and around Grand Canyon, Arizona, in the 1940s through 1960s. The two largest of these planned dams were the Marble Canyon and Bridge Canyon Dams on the Colorado River. Though these dams were ultimately never built, Reclamation conducted extensive topographic, bathymetric, and subsurface exploration work at the sites proposed for these dams in the 1940s and 1950s. Resurveys of these dam sites were conducted between 1998 and 2021 to determine the changes in sediment storage at these dam sites caused by the upstream construction and operation of Glen Canyon Dam and by the recession of Lake Mead, the reservoir impounded by Hoover Dam. The resurveys of the Marble Canyon dam sites indicate that the post-1950s changes in sediment storage at these dam sites are broadly consistent with flux-based estimates of voluminous sand erosion from Marble Canyon since the 1963 closure of Glen Canyon Dam. These resurveys also suggest that the pre-dam longitudinal variation in sediment thickness over bedrock played a key role in determining the locations of the sand erosion induced by Glen Canyon Dam; more sand eroded from locations where more sand was present in the 1950s. The resurvey of the Bridge Canyon dam sites indicates that the Colorado River’s incision of the Lake Mead delta is regulated both by bed-sediment grain size and downstream hydraulic controls. Finally, analyses of bed-sediment thickness and sedimentological data at the dam sites, and observations of bed scour and gravel transport, suggest that sufficient bedrock was exposed to allow bedrock incision during commonly recurring pre-dam snowmelt floods that entrained small boulders into transport.

Arizona↗

The eruptive behavior of distributed volcanism forming low shield edifices—A case study of Sentinel-Arlington volcanic field, U.S.A.

Distributed volcanic fields are present in various tectonic settings worldwide, and their characteristics reflect differing influences from magmatic and tectonic processes. In the southwestern United States alone, there are 37 Quaternary distributed volcanic fields. After the primary period of extensional tectonics in the southern Basin and Range 15–5 million years ago, the Sentinel-Arlington volcanic field developed in southwestern Arizona between 4 and 1 million years ago. The Sentinel-Arlington volcanic field consists primarily of low relief shield volcanoes, a type of distributed volcanism with poorly understood temporal evolution. The Sentinel-Arlington volcanic field is less than 200 kilometers (km) from the Colorado Plateau, Gulf of California, and southern San Andreas Fault system. This work identifies and examines controls on the emplacement of the Sentinel-Arlington volcanic field by documenting shallow and surficial structures as well as eruption characteristics and style through time. The Sentinel-Arlington volcanic field consists of 21 volcanoes with a total of 33 vents over an area of about 770 square kilometers (km 2 ). The prominence of low relief shield volcanoes may be explained by ascent of basaltic magmas through thin Basin and Range crust, without much crustal contamination, and low viscosities common to mafic compositions. Typical eruption characteristics involve the construction of low relief shield volcanoes followed by Strombolian fissure eruptions at the summits or near-summit medial areas that produce scoria lapilli, which may weld to form agglomerate. The total lifetime erupted volume of about 4.3 cubic kilometers (km 3 ) represents an average eruptive flux of approximately 2x10 -3 km 3 per thousand years (k.y.). This erupted volume is low relative to Neogene basaltic intraplate distributed volcanic fields worldwide, which typically range from 10 -3 to 1 km 3 k.y. -1 . Sentinel-Arlington volcanic field eruptions were likely triggered by intermittent rejuvenation of transient magmatic zones that exist in thinned crust. Instantaneous flux from point sources feeding the lava flows is estimated to be on the order of 10 -1 to 10 cubic meters per second.

Arizona↗

Capitalization of positional (Lower/Middle/Upper) and temporal (Early/Middle/Late) adjectives in the names of formal chronostratigraphic and geochronologic units of the Phanerozoic

Many authors are understandably confused about the capitalization of the words “lower,” “middle,” “upper,” “early,” and “late.” Where these words are used simply as descriptive adjectives, they should be in lowercase; where they form the first word of a formal chronostratigraphic or geochronologic unit name, they should be in uppercase.

Professional Paper↗