USGS Science⌕ Search

USGS · pp1404M

Simulation of ground-water flow in the Coastal Plain aquifer system of North Carolina

Abstract

A three-dimensional finite-difference digital model was used to simulate ground-water flow in the 25,000-square-mile aquifer system of the North Carolina Coastal Plain. The model was developed from a hydrogeologic framework that is based on an alternating sequence of 10 aquifers and 9 confining units, which make up a seaward-thickening wedge of sediments that form the Coastal Plain aquifer system in the State of North Carolina. The model was calibrated by comparing observed and simulated water levels. The model calibration was achieved by adjusting model parameters, primarily leakance of confining units and transmissivity of aquifers, until differences between observed and simulated water levels were within acceptable limits, generally within 15 feet. The maximum transmissivity of an individual aquifer in the calibrated model is 200,000 feet squared per day in a part of the Castle Hayne aquifer, which consists predominantly of limestone. The maximum value for simulated vertical hydraulic conductivity in a confining unit was 2.5 feet per day, in a part of the confining unit overlying the upper Cape Fear aquifer. The minimum value was 4.1x10-6 feet per day, in part of the confining unit overlying the lower Cape Fear aquifer. Analysis indicated the model is highly sensitive to changes in transmissivity and leakance near pumping centers; away from pumping centers, the model is only slightly sensitive to changes in transmissivity but is moderately sensitive to changes in leakance. Recharge from precipitation to the surficial aquifer ranges from about 12 inches per year in areas having clay at the surface to about 20 inches per year in areas having sand at the surface. Most of this recharge moves laterally to streams, and only about 1 inch per year moves downward to the confined parts of the aquifer system. Under predevelopment conditions, the confined aquifers were generally recharged in updip interstream areas and discharged through streambeds and in downdip coastward areas. Hydrologic analysis of the flow system using the calibrated model indicated that, because of ground-water withdrawals, areas of ground-water recharge have expanded and encroached upon some major stream valleys and into coastal area. Simulations of pumping conditions indicate that by 1980 large parts of the former coastal discharge areas had become areas of potential or actual recharge. Declines of ground-water level, which are the result of water taken from storage, are extensive in some areas and minimal in others. Hydraulic head declines of more than 135 feet have occurred in the northern Coastal Plain since 1940 primarily due to withdrawals in the Franklin area in Virginia. Declines of ground-water levels greater than 110 feet have occurred in aquifers in the central Coastal Plain due to combined effects of pumpage for public and industrial water supplies. Water-level declines exceeding 100 feet have occurred in the Beaufort County area because of withdrawals for a mining operation and water supplies for a chemical plant. Head declines have been less than 10 feet in the shallow surficial and Yorktown aquifers and in the updip parts of the major confined aquifers distant from areas of major withdrawals. In 1980, contribution from aquifer storage was 14 cubic feet per second, which is about 4.8 percent of pumpage and about 0.05 percent of ground-water recharge. A water-budget analysis using the model simulations indicates that much of the water removed from the ground-water system by pumping ultimately is made up by a reduction in water leaving the aquifer system, which discharges to streams as base flow. The reduction in stream base flow was 294 cubic feet per second in 1980 and represents about 1.1 percent of the ground-water recharge. The net reduction to streamflow is not large, however, because most pumped ground water is eventually discharged to streams. In places, such as at rock quarries in Onslow and Craven Counties, water is lost from st

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 33.715201644740844° to 36.57142382346277° latitude; -80.496826171875° to -75.322265625° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G.I. Giese, J. L. Eimers, R. W. Coble. 1997. Simulation of ground-water flow in the Coastal Plain aquifer system of North Carolina. https://doi.org/10.3133/pp1404m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Resurvey of the Marble Canyon and Bridge Canyon dam sites in Grand Canyon National Park—Changes in sediment storage and evidence supporting the occurrence of bedrock incision through the mid-20th century

The Bureau of Reclamation developed an extensive plan for a network of dams, water tunnels, and hydropower plants in and around Grand Canyon, Arizona, in the 1940s through 1960s. The two largest of these planned dams were the Marble Canyon and Bridge Canyon Dams on the Colorado River. Though these dams were ultimately never built, Reclamation conducted extensive topographic, bathymetric, and subsurface exploration work at the sites proposed for these dams in the 1940s and 1950s. Resurveys of these dam sites were conducted between 1998 and 2021 to determine the changes in sediment storage at these dam sites caused by the upstream construction and operation of Glen Canyon Dam and by the recession of Lake Mead, the reservoir impounded by Hoover Dam. The resurveys of the Marble Canyon dam sites indicate that the post-1950s changes in sediment storage at these dam sites are broadly consistent with flux-based estimates of voluminous sand erosion from Marble Canyon since the 1963 closure of Glen Canyon Dam. These resurveys also suggest that the pre-dam longitudinal variation in sediment thickness over bedrock played a key role in determining the locations of the sand erosion induced by Glen Canyon Dam; more sand eroded from locations where more sand was present in the 1950s. The resurvey of the Bridge Canyon dam sites indicates that the Colorado River’s incision of the Lake Mead delta is regulated both by bed-sediment grain size and downstream hydraulic controls. Finally, analyses of bed-sediment thickness and sedimentological data at the dam sites, and observations of bed scour and gravel transport, suggest that sufficient bedrock was exposed to allow bedrock incision during commonly recurring pre-dam snowmelt floods that entrained small boulders into transport.

Arizona↗

The eruptive behavior of distributed volcanism forming low shield edifices—A case study of Sentinel-Arlington volcanic field, U.S.A.

Distributed volcanic fields are present in various tectonic settings worldwide, and their characteristics reflect differing influences from magmatic and tectonic processes. In the southwestern United States alone, there are 37 Quaternary distributed volcanic fields. After the primary period of extensional tectonics in the southern Basin and Range 15–5 million years ago, the Sentinel-Arlington volcanic field developed in southwestern Arizona between 4 and 1 million years ago. The Sentinel-Arlington volcanic field consists primarily of low relief shield volcanoes, a type of distributed volcanism with poorly understood temporal evolution. The Sentinel-Arlington volcanic field is less than 200 kilometers (km) from the Colorado Plateau, Gulf of California, and southern San Andreas Fault system. This work identifies and examines controls on the emplacement of the Sentinel-Arlington volcanic field by documenting shallow and surficial structures as well as eruption characteristics and style through time. The Sentinel-Arlington volcanic field consists of 21 volcanoes with a total of 33 vents over an area of about 770 square kilometers (km 2 ). The prominence of low relief shield volcanoes may be explained by ascent of basaltic magmas through thin Basin and Range crust, without much crustal contamination, and low viscosities common to mafic compositions. Typical eruption characteristics involve the construction of low relief shield volcanoes followed by Strombolian fissure eruptions at the summits or near-summit medial areas that produce scoria lapilli, which may weld to form agglomerate. The total lifetime erupted volume of about 4.3 cubic kilometers (km 3 ) represents an average eruptive flux of approximately 2x10 -3 km 3 per thousand years (k.y.). This erupted volume is low relative to Neogene basaltic intraplate distributed volcanic fields worldwide, which typically range from 10 -3 to 1 km 3 k.y. -1 . Sentinel-Arlington volcanic field eruptions were likely triggered by intermittent rejuvenation of transient magmatic zones that exist in thinned crust. Instantaneous flux from point sources feeding the lava flows is estimated to be on the order of 10 -1 to 10 cubic meters per second.

Arizona↗

Capitalization of positional (Lower/Middle/Upper) and temporal (Early/Middle/Late) adjectives in the names of formal chronostratigraphic and geochronologic units of the Phanerozoic

Many authors are understandably confused about the capitalization of the words “lower,” “middle,” “upper,” “early,” and “late.” Where these words are used simply as descriptive adjectives, they should be in lowercase; where they form the first word of a formal chronostratigraphic or geochronologic unit name, they should be in uppercase.

Professional Paper↗