In May 1980, the University of Minnesota began a project to evaluate the feasibility of storing heated water (150 degrees Celsius) in the Franconia-Ironton-Galesville aquifer (180 to 240 meters below land surface) and later recovering it for space heating. The University's steam-generation facilities supplied high-temperature water for injection. The Aquifer Thermal-Energy Storage system is a doublet-well design in which the injection-withdrawal wells are spaced approximately 250 meters apart. Water was pumped from one of the wells through a heat exchanger, where heat was added or removed. This water was then injected back into the aquifer through the other well. Four short-term test cycles were completed. Each cycle consisted of approximately equal durations of injection and withdrawal ranging from 5.25 to 8.01 days. Equal rates of injection and withdrawal, ranging from 17.4 to 18.6 liters per second, were maintained for each short-term test cycle. Average injection temperatures ranged from 88.5 to 117.9 degrees Celsius. Temperature graphs for selected depths at individual observation wells indicate that the Ironton and Galesville Sandstones received and stored more thermal energy than the upper part of the Franconia Formation. Clogging of the Ironton Sandstone was possibly due to precipitation of calcium carbonate or movement of fine-grain material or both. Vertical-profile plots indicate that the effects of buoyancy flow were small within the aquifer. A three-dimensional, anisotropic, nonisothermal, ground-water-flow, and thermal-energy-transport model was constructed to simulate the four short-term test cycles. The model was used to simulate the entire short-term testing period of approximately 400 days. The only model properties varied during model calibration were longitudinal and transverse thermal dispersivities, which, for final calibration, were simulated as 3.3 and 0.33 meters, respectively. The model was calibrated by comparing model-computed results to (1) measured temperatures at selected altitudes in four observation wells, (2) measured temperatures at the production well, and (3) calculated thermal efficiencies of the aquifer. Model-computed withdrawal-water temperatures were within an average of about 3 percent of measured values and model-computed aquifer-thermal efficiencies were within an average of about 5 percent of calculated values for the short-term test cycles. These data indicate that the model accurately simulated thermal-energy storage within the Franconia-Ironton-Galesville aquifer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert T. Miller, G. N. Delin. 1994. Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota: Analysis of thermal data and nonisothermal modeling of short-term test cycles. https://doi.org/10.3133/ofr93435

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Special Contributing Area Loading Program user’s manual

Information on the Special Contributing Area Loading Program execution and functions are presented in this user’s manual. An appendix presents a potential improvement for the user to consider. The hydrologic routing simulation method to model flow through multiple reservoirs, or sewer system components, is described. The use of Special Contributing Areas is described to run a successful simulation, which includes user input of hydrologic time series of flow components and the necessary formats. Upon completion of a successful Special Contributing Area Loading Program simulation, the program outputs hydrologic time series and a descriptive text file containing the model results for each defined sub-unit, or Special Contributing Area. The output time series contain flows through, and overflows from, the three reservoirs in the series, and the text file contains input and output path locations.

Open-File Report↗

Estimating aftershock risk for entry into earthquake-damaged buildings

We present a simple method to estimate the risk of experiencing strong shaking from aftershocks during entry into earthquake-damaged buildings. We compute wait times until the probability of strong ground shaking from aftershocks reaches a predefined risk threshold; for example, a 0.4 percent probability of experiencing Modified Mercalli Intensity 7 or greater shaking during the planned building entry. We also develop a relation between aftershock probability and the probability of strong shaking, so that users can reference the U.S. Geological Survey aftershock forecast during an ongoing aftershock sequence to determine if the risk threshold has been met. We apply our method to active continental regions (for example, the Western United States), stable continental regions (for example, the Central and Eastern United States), and subduction zones (for example, Cascadia or Alaska).

Open-File Report↗

End-user needs for remote sensing wetlands of the Prairie Pothole Region of North America

The Prairie Pothole Region (PPR) of North America comprises globally important grassland and wetland ecosystems critical for numerous populations of migratory birds. Due to the importance of this region for migratory birds, and particularly waterfowl, and the threats of habitat loss due to intensifying agriculture, there is a mature and diverse system of conservation organizations, agencies, and partnerships that spends hundreds of millions of dollars annually on habitat conservation to support migratory bird populations. Remote sensing can be a powerful tool for observing and evaluating global change at large scales as well as expanding inferences from field studies to the broader landscape with statistical models. However, development and utilization of these tools has lagged behind their demand for several reasons, including concerns over spatial and temporal resolution and accuracy of products; perception of a misalignment with decision-maker needs; technological barriers such as skill sets of conservation professionals, computing resources, data access, and usability. In this report, we summarize the needs of conservation professionals and scientists who use or want to use remote sensing data products to inform science about wetland change and conservation of wetlands in the PPR. We assembled this information through several methods leading up to, during, and following a January 2026 PPR Wetland Remote Sensing Workshop. The workshop included United States and Canadian scientists, conservation professionals, and policy experts. Our goal was to bring together end-users and remote sensing product developers jointly to explore reducing the lag between product development and utilization of products to inform science and conservation. Specifically, we aimed to identify gaps in wetland remote sensing that limit effective monitoring, management, and conservation in the PPR, and to develop a framework that outlines pathways to address these gaps by fostering collaboration, improving communication networks, encouraging discussion, and building on existing and ongoing efforts. This report summarizes our participants’ descriptions of end-user needs and the outcomes of the workshop.

Prairie Pothole region↗