Description and preliminary testing of the CDSN Seismic Sensor Systems

Abstract

The China Digital Seismograph Network (CDSN) is being designed and installed to provide the People's Republic of China with the facilities needed to create a national digital database for earthquake research. The CDSN, which is being developed jointly by the PRC State Seismological Bureau and the U.S. Geological Survey, will consist initially of nine digitally-recording seismograph stations, a data management system to be used for compiling network-day tapes, and a depot maintenance center. Data produced by the network will be shared with research scientists throughout the world. A national seismograph network must be designed to support a variety of research objectives. From this standpoint, the choices and tradeoffs involved in specifying signal bandwidth, resolution, and dynamic range are the most important decisions in system design. As in the case of the CDSN, these decisions are made during the selection and design of the seismic sensor system and encoder components. The purpose of this report is to describe the CDSN sensor systems, their important signal characteristics, and the results of preliminary tests that have been performed on the instruments. Four overlapping data bands will be recorded at each station: short period (SP), broadband (BB), long period (LP), and very long period (VLP). Amplitude response curves are illustrated in Figure I. Vertical and horizontal components will be recorded for each data band. The SP and LP channels will be recorded with sufficient sensitivities to resolve earth background noise at seismically quiet sites. The BB channels will have a lower sensitivity and are intended for broadband recording of moderate-to-large body-wave signals and for increasing the effective amplitude range in the short- and long-period bands. The VLP channel does not provide additional spectral coverage at long periods; its purpose is to make use of on-site filtration and decimation to reduce post processing requirements for VLP studies. Early plans also included a triaxial set of low-sensitivity accelerometers for recording strong signals from large local and regional earthquakes. The accelerometers are not being installed; however, they may be added in the future. The short-period signals will be derived from a three-component set of PRC-supplied Model DJ-I SP seismometers and US-supplied SP amplifiers. The seismometers will be installed in surface or shallow subsurface vaults, except at two of the stations where they will be installed in boreholes. The BB, LP, and VLP signals will be derived from Streckeisen STS-1 broadband sensor systems installed in vaults, except at one site where the LP signals only will-be derived from a KS-36000 borehole seismometer installed at a depth of 100 meters. Analog signals will be sampled and quantized by an analog-to-digital converter (ADC) that is part of the recording system. Sampling rates chosen for the CDSN are as follows: * SP 40 samples/second * BB 20 samples/second * LP 1 sample/second * VLP 6 samples/minute The ADC 16-bit data word format makes use of 14 bits to quantize the signal and 2 bits to specify an automatically ranged gain of 1, 8, 32, or 128. This will provide 84 dB of resolution and up to 42 dB of gain ranging for a total opera- ting range of 126 dB peak to peak. Magnetic tape cartridges, each having a capacity of 67 megabytes, will be used for recording the digital data. LP and VLP data will be recorded continu- ously. SP and BB data will be processed through an automatic signal detector of the type described by Murdock and Hutt (1983), and only detected events will be stored on tape. Detection parameters, such as turn-on sensitivity and mini- mum recording duration for the SP and BB channels, will be fully programmable and easily changed. One or more of the data channels may also be recorded on analog recorders. A CDSN recording system was not available at the time that the preliminary tests were performed on the CDSN sensor systems. This did not interfere with the principal goals of the testing which were to determine the best sensor installation techniques and to demonstrate the operational performance of the sensor systems, especially with regard to instrument noise and detection capability. When the CDSN recording system is available, additional tests will be performed to measure distortion levels in the full system and components. Distortion tests have been performed on the Streckeisen STS-1 broadband seismometers, the most critical component from the standpoint of linearity, and the results of the tests are reported by Wielandt and Streckeisen (1982). Calibration accuracy and stability are also important sensor system characteristics that cannot be defined without additional testing. These tests will be performed as the instruments are installed at the stations and periodically during operation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jon Peterson, Edwin E. Tilgner. 1985. Description and preliminary testing of the CDSN Seismic Sensor Systems. https://doi.org/10.3133/ofr85288

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗