USGS Science⌕ Search

USGS · ofr20261063

Evaluation of turbidity corrections for EXO fluorescent dissolved organic matter (fDOM) sensors

Abstract

Executive Summary The use of field-deployable fluorescence sensors to better understand dissolved organic matter concentrations and composition has grown immensely in recent years. Applications of these sensors to critical monitoring efforts have also grown, encompassing post-fire monitoring, wastewater tracking, and use as a proxy for various contaminants. Despite the growth, it is well known that these sensors require corrections for temperature (Watras and others, 2011) and are subject to many light-field interferences caused by both scattering and absorbance due to dissolved and particulate substances (Downing and others, 2012; Lee and others, 2015; Booth and others, 2023). The most common fluorescence sensors used by the U.S. Geological Survey (USGS) include those targeting fluorescent dissolved organic matter (fDOM) and chlorophylls. Because fDOM sensors primarily measure fluorescence in the dissolved to colloidal phases, corrections to the interferences caused by particulates can be made relatively easily. By the end of 2024, the USGS had 69 fDOM sensors deployed within official water quality monitoring networks included on the USGS National Water Dashboard ( https://dashboard.waterdata.usgs.gov/app/nwd/en/ ) and numerous others used in surveys and research applications across the Nation. Although temperature corrections are widely applicable across sensor models, interference corrections can be model specific due to differences in design specifications across manufacturers and models (Booth and others, 2023). The corrections are also potentially subject to changes in manufacturing within a specific sensor model. Recently, USGS staff obtained information regarding possible changes in the manufacturing of its most widely-used fDOM sensor model, raising concerns about data consistency and quality in the USGS fDOM sensor networks. Furthermore, changes in turbidity sensors since the corrections guidance was performed may also affect the performance of the corrections. The turbidity sensor used in the original experiments (Downing and others, 2012) was determined to have a signal output approximately 1.3 times higher than the output of the turbidity sensor currently used in an extensive field comparison study (Messner and others, 2023). With these changes, it is imperative that the corrections be reevaluated to maintain data consistency and continuity across the USGS. In this study, we evaluated turbidity corrections for fDOM sensors over a range of serial numbers covering manufacturing dates 2015 through 2022 and turbidity serial numbers covering the range 2013 through 2022. The goal was to determine whether reported changes in the manufacturing process of the fDOM and turbidity sensors affected the correction approach developed by Downing and others (2012) such that additional guidance would be required to address this manufacturing change. To evaluate, we repeated a laboratory-based test similar to that performed by Downing and others (2012) in which a series of tank experiments with multiple sensors were deployed in a suspension of Elliot Silt Loam (ESL). High turbidities of the ESL suspension were maintained throughout the tank by turbulent recirculation using submersible pumps. Particulates were removed using a recirculated line equipped with a capsule filter (0.45 micron). Measurements were collected throughout the filtration until turbidities reached approximately 5 formazin nephelometric units (FNU; data available in Baxter and others, 2023). Each experimental run included a mixture of unique sensor combinations to account for variability imposed by the turbidity and temperature sensors. The fDOM correction factor was calculated for each combination of fDOM and turbidity sensors included in the test. We observed no systematic change in fDOM correction coefficients across serial numbers representing manufacturing years 2015 through 2022. However, the results highlighted questions raised about the corrections for high-turbidity samples, as noted in USGS Techniques and Methods (Booth and others, 2023). Applying the inverse of the commonly-used fDOM ratio with a quadratic fit performed better than the exponential fits when correcting fDOM data for turbidity in the ESL laboratory filtration test and generated a simple scale factor correction equation. This approach also served as a better indicator of data quality than the exponential fit approach. Similar to fDOM, more rigorous quality assurance measures may be necessary to evaluate turbidity sensor calibrations and performance. Sensors exceeding a certain age may need to be replaced despite passing quality assurance checks during calibration. Further testing of the turbidity corrections for different sediment and water types is warranted to better understand the variations in the fits and correctable ranges of turbidity in different systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jacob A. Fleck, Tim James Baxter, Angela Hansen. 2026-03-06. Evaluation of turbidity corrections for EXO fluorescent dissolved organic matter (fDOM) sensors. https://doi.org/10.3133/ofr20261063

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗