USGS Science⌕ Search

USGS · ofr20101102

Method description, quality assurance, environmental data, and other Information for analysis of pharmaceuticals in wastewater-treatment-plant effluents, streamwater, and reservoirs, 2004-2009

Abstract

Abstract Wastewater-treatment-plant (WWTP) effluents are a demonstrated source of pharmaceuticals to the environment. During 2004-09, a study was conducted to identify pharmaceutical compounds in effluents from WWTPs (including two that receive substantial discharges from pharmaceutical formulation facilities), streamwater, and reservoirs. The methods used to determine and quantify concentrations of seven pharmaceuticals are described. In addition, the report includes information on pharmaceuticals formulated or potentially formulated at the two pharmaceutical formulation facilities that provide substantial discharge to two of the WWTPs, and potential limitations to these data are discussed. The analytical methods used to provide data on the seven pharmaceuticals (including opioids, muscle relaxants, and other pharmaceuticals) in filtered water samples also are described. Data are provided on method performance, including spike data, method detection limit results, and an estimation of precision. Quality-assurance data for sample collection and handling are included. Quantitative data are presented for the seven pharmaceuticals in water samples collected at WWTP discharge points, from streams, and at reservoirs. Occurrence data also are provided for 19 pharmaceuticals that were qualitatively identified. Flow data at selected WWTP and streams are presented. Between 2004-09, 35-38 effluent samples were collected from each of three WWTPs in New York and analyzed for seven pharmaceuticals. Two WWTPs (NY2 and NY3) receive substantial inflows (greater than 20 percent of plant flow) from pharmaceutical formulation facilities (PFF) and one (NY1) receives no PFF flow. Samples of effluents from 23 WWTPs across the United States were analyzed once for these pharmaceuticals as part of a national survey. Maximum pharmaceutical effluent concentrations for the national survey and NY1 effluent samples were generally less than 1 ug/L. Four pharmaceuticals (methadone, oxycodone, butalbital and metaxalone) in samples of NY3 effluent had median concentrations ranging from 3.4 to greater than 400 ug/L. Maximum concentrations of oxycodone (1,700 ug/L) and metaxalone (3,800 ug/L) in samples from NY3 effluent exceeded 1,000 ug/L. Three pharmaceuticals (butalbital, carisoprodol, and oxycodone) in samples of NY2 effluent had median concentrations ranging from 2 to 11 ug/L. These findings suggest that current 2 manufacturing practices at these PFFs can result in pharmaceutical concentrations from 10 to 1,000 times higher than those typically found in WWTP effluents.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Patrick J. Phillips, Steven G. Smith, Dana W. Kolpin, Steven D. Zaugg, Herbert T. Buxton, Edward T. Furlong. 2010. Method description, quality assurance, environmental data, and other Information for analysis of pharmaceuticals in wastewater-treatment-plant effluents, streamwater, and reservoirs, 2004-2009. https://doi.org/10.3133/ofr20101102

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗