USGS Science⌕ Search

USGS · 70199565

Artificial recharge through a thick, heterogeneous unsaturated zone

Abstract

Thick, heterogeneous unsaturated zones away from large streams in desert areas have not previously been considered suitable for artificial recharge from ponds. To test the potential for recharge in these settings, 1.3 x 10 6 m 3 of water was infiltrated through a 0.36-ha pond along Oro Grande Wash near Victorville, California, between October 2002 and January 2006. The pond overlies a regional pumping depression 117 m below land surface and is located where thickness and permeability of unsaturated deposits allowed infiltration and saturated alluvial deposits were sufficiently permeable to allow recovery of water. Because large changes in water levels caused by nearby pumping would obscure arrival of water at the water table, downward movement of water was measured using sensors in the unsaturated zone. The downward rate of water movement was initially as high as 6 m/d and decreased with depth to 0.07 m/d; the initial time to reach the water table was 3 years. After the unsaturated zone was wetted, water reached the water table in 1 year. Soluble salts and nitrate moved readily with the infiltrated water, whereas arsenic and chromium were less mobile. Numerical simulations done using the computer program TOUGH2 duplicated the downward rate of water movement, accumulation of water on perched zones, and its arrival at the water table. Assuming 10 3 106 m3 of recharge annually for 20 years, a regional ground water flow model predicted water level rises of 30 m beneath the ponds, and rises exceeding 3m in most wells serving the nearby urban area.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John A. Izbicki, Alan L. Flint, Christina L. Stamos. 2008-01-09. Artificial recharge through a thick, heterogeneous unsaturated zone. https://doi.org/10.1111/j.1745-6584.2007.00406.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Computing flow-field distortion coefficients from well-construction and formation properties

Direct measurements of groundwater velocity made with borehole flowmeters in screened wells must be compensated for the effects of flow-field distortion (also known as borehole acceleration). A theoretical equation developed by Drost et al. (1968) and simple inputs describing hydraulic properties of well construction and geologic formation were programmed into an Excel workbook to facilitate computation by groundwater-flowmeter users. Tables describing the physical and hydraulic properties for well constructions and gravel pack media are provided with an example to facilitate use of the workbook. Groundwater flowlines converge or diverge as they pass from a geologic formation, through a gravel pack and well screen. The extent of flowline convergence or divergence and the value of the flow-field distortion coefficient is related to the relative changes in hydraulic conductivity of the well screen, gravel pack, and geologic formation. Convergence or divergence is accompanied by acceleration or deceleration of groundwater. Direct measurements of groundwater velocity at the center of the monitoring well can be adjusted to provide a more accurate estimate of velocity in the formation by applying a correction for flow-field distortion. Variables required to compute the flow-field distortion coefficient include the hydraulic conductivity of the gravel pack, well screen, and the geologic formation surrounding the well screen; the borehole radius, and the inside radius and outside radius of the well screen.

Groundwater↗

Predicting groundwater hydrochemical facies in three dimensions with random forest classification, USA

A random forest classification (RFC) model was developed to predict hydrochemical facies (HCFs) of groundwater in three dimensions across the conterminous United States (CONUS). Major-ion data from 152,673 sites were used to categorize groundwater into one of six HCFs (CaMg-HCO 3 , NaK-HCO 3 , CaMg-SO 4 , NaK-SO 4 , Cl, or Mixed). These six HCFs were used as targets for RFC modeling. Model features that represent relevant geochemical processes and/or physical conditions were derived from previously published data. Additional model features were specifically engineered to support this analysis: elevation of the bottom of a well relative to the base of drinking water (ERDW) and six flags that relate geologic units to HCFs. The most important model feature was ERDW. The model was used to map HCFs at a 1-km 2 resolution across CONUS and to depths of 400 m below the base of drinking water (which varies from 22 m to 2 km). Model predictions are consistent with expectations. CaMg-HCO 3 is predicted to occur near the water table in more humid settings, and areas underlain by carbonate or crystalline rocks. At depths below the base of drinking-water supplies, the model predicts a rapid transition from HCO 3 HCFs to Cl. Model predictions are accurate based on point data, and data averaged across hydrogeologic regions and with depth. Model predictions of HCFs could be used for multiple purposes, including the mapping of salinity and other groundwater characteristics.

Groundwater↗