USGS ScienceSearch

USGS · 70184480

Transport and time lag of chlorofluorocarbon gases in the unsaturated zone, Rabis Creek, Denmark

Abstract

Transport of chlorofluorocarbon (CFC) gases through the unsaturated zone to the water table is affected by gas diffusion, air–water exchange (solubility), sorption to the soil matrix, advective–dispersive transport in the water phase, and, in some cases, anaerobic degradation. In deep unsaturated zones, this may lead to a time lag between entry of gases at the land surface and recharge to groundwater. Data from a Danish field site were used to investigate how time lag is affected by variations in water content and to explore the use of simple analytical solutions to calculate time lag. Numerical simulations demonstrate that either degradation or sorption of CFC-11 takes place, whereas CFC-12 and CFC-113 are nonreactive. Water flow did not appreciably affect transport. An analytical solution for the period with a linear increase in atmospheric CFC concentrations (approximately early 1970s to early 1990s) was used to calculate CFC profiles and time lags. We compared the analytical results with numerical simulations. The time lags in the 15-m-deep unsaturated zone increase from 4.2 to between 5.2 and 6.1 yr and from 3.4 to 3.9 yr for CFC-11 and CFC-12, respectively, when simulations change from use of an exponential to a linear increase in atmospheric concentrations. The CFC concentrations at the water table before the early 1990s can be estimated by displacing the atmospheric input function by these fixed time lags. A sensitivity study demonstrates conditions under which a time lag in the unsaturated zone becomes important. The most critical parameter is the tortuosity coefficient. The analytical approach is valid for the low range of tortuosity coefficients (τ = 0.1–0.4) and unsaturated zones greater than approximately 20 m in thickness. In these cases the CFC distribution may still be from either the exponential or linear phase. In other cases, the use of numerical models, as described in our work and elsewhere, is an option.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter Engesgaard, Anker L. Højberg, Klaus Hinsby, Karsten H. Jensen, Troels Laier, Flemming Larsen, Eurybiades Busenberg, Niel Plummer. 2004. Transport and time lag of chlorofluorocarbon gases in the unsaturated zone, Rabis Creek, Denmark. https://doi.org/10.2136/vzj2004.1249

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Network-wide assessment of soil water content calibration and sensitivity to biomass proxies using cosmic-ray neutron sensing in the Roaring Fork Basin, Colorado

Soil water content (SWC) is a key state variable of the climate system but is often uncertain in water balance monitoring, especially in alpine environments. SWC measurements can be challenging in alpine environments due to the topography and rocky soils. In 2022, the US Geological Survey's Next Generation Water Observing System Program began research to evaluate water balance monitoring technologies, including cosmic-ray neutron sensors (CRNS). This work evaluated the uncertainty resulting from network-wide calibration of CRNS for SWC monitoring in an alpine watershed and investigated the stability of the calibration parameters across space and time, focusing on potential influence of biomass dynamics. Fifteen stations with moderated and unmoderated (bare) CRNS were deployed and made operational within the Roaring Fork Basin in west-central Colorado. The root mean squared error of the network-wide calibration using the moderated CRNS was 0.042 or 0.047 cm 3 cm −3 , depending on the calibration equation used. Relative SWC dynamics from CRNS were correlated with the in situ probes with a correlation coefficient of 0.91 or 0.87 (depending on calibration equation). We did not find significant relationships between the calibration parameters and stationary site-specific variables. However, the calibration parameters derived from in situ probe SWC dynamics varied over time and were correlated with biomass proxies of cumulative growing degree-day, cumulative growing season index, and bare neutron counts. Future use of the CRNS network can leverage the reliable relative SWC data from network-wide calibration for watershed modeling and continue to research sensitivity of bare neutron measurements to biomass dynamics.

Colorado

Identifying preferential flow from soil moisture time series: Review of methodologies

Identifying and quantifying preferential flow (PF) through soil—the rapid movement of water through spatially-distinct pathways in the subsurface—is vital to understanding how the hydrologic cycle responds to climate, land cover, and anthropogenic changes. In recent decades, methods have been developed that use measured soil moisture time series to identify PF. Because they allow for continuous monitoring and are relatively easy to implement, these methods have become an important tool for recognizing when, where, and under what conditions PF occurs. The methods seek to identify a pattern or quantification that indicates the occurrence of PF. Most commonly, the chosen signature is either (1) a nonsequential response to infiltrated water, in which soil moisture responses do not occur in order of shallowest to deepest, or (2) a velocity criterion, in which newly infiltrated water is detected at depth earlier than is possible by nonpreferential flow processes. Alternative signatures have also been developed that have certain advantages but are less commonly utilized. Choosing among these possible signatures requires attention to their pertinent characteristics, including susceptibility to errors, possible bias toward false negatives or false positives, reliance on subjective judgments, and possible requirements for additional types of data. We review 77 studies that have applied such methods, to highlight important information for readers who want to identify PF from soil moisture data, and to inform those who aim to develop new methods or improve existing ones.

Vadose Zone Journal

Field evaluation of semi-automated moisture estimation from geophysics using machine learning

Geophysical methods can provide three-dimensional (3D), spatially continuous estimates of soil moisture. However, point-to-point comparisons of geophysical properties to measure soil moisture data are frequently unsatisfactory, resulting in geophysics being used for qualitative purposes only. This is because (1) geophysics requires models that relate geophysical signals to soil moisture, (2) geophysical methods have potential uncertainties resulting from smoothing and artifacts introduced from processing and inversion, and (3) results from multiple geophysical methods are not easily combined within a single soil moisture estimation framework. To investigate these potential limitations, an irrigation experiment was performed wherein soil moisture was monitored through time, and several surface geophysical datasets indirectly sensitive to soil moisture were collected before and after irrigation: ground penetrating radar, electrical resistivity tomography (ERT), and frequency domain electromagnetics (FDEM). Data were exported in both raw and processed form, and then snapped to a common 3D grid to facilitate moisture prediction by standard calibration techniques, multivariate regression, and machine learning. A combination of inverted ERT data, raw FDEM, and inverted FDEM data was most informative for predicting soil moisture using a random regression forest model (one-thousand 60/40 training/test cross-validation folds produced root mean squared errors ranging from 0.025–0.046 cm 3 /cm 3 ). This cross-validated model was further supported by a separate evaluation using a test set from a physically separate portion of the study area. Machine learning was conducive to a semi-automated model-selection process that could be used for other sites and datasets to locally improve accuracy.

Connecticut