USGS ScienceSearch

USGS · 70178328

Delineating a road-salt plume in lakebed sediments using electrical resistivity, piezometers, and seepage meters at Mirror Lake, New Hampshire, U.S.A

Abstract

Electrical-resistivity surveys, seepage meter measurements, and drive-point piezometers have been used to characterize chloride-enriched groundwater in lakebed sediments of Mirror Lake, New Hampshire, U.S.A. A combination of bottom-cable and floating-cable electrical-resistivity surveys identified a conductive zone ( &lt; 100 ohm- m ) "> ( < 100 ohm- m ) (<100ohm-m) overlying resistive bedrock ( &lt; 1000 ohm- m ) "> ( < 1000 ohm- m ) (<1000ohm-m) beneath the lake. Shallow pore-water samples from piezometers in lakebed sediments have chloride concentrations of 200 &#x2013; 1800 &#x3BC; eq / liter "> 200 – 1800 μ eq / liter 200–1800μeq/liter , and lake water has a chloride concentration of 104 &#x3BC; eq / liter "> 104 μ eq / liter 104μeq/liter . The extent of the plume was estimated and mapped using resistivity and water-sample data. The plume ( 20 &#xD7; 35 m "> 20 × 35 m 20×35m wide and at least 3 m "> 3 m 3m thick) extends nearly the full length and width of a small inlet, overlying the top of a basin formed by the bedrock. It would not have been possible to mapthe plume's shape without the resistivity surveys because wells provided only limited coverage. Seepage meters were installed approximately 40 m "> 40 m 40m from the mouth of a small stream discharging at the head of the inlet in an area where the resistivity data indicated lake sediments are thin. These meters recorded in-seepage of chloride-enriched groundwater at rates similar to those observed closer to shore, which was unexpected because seepage usually declines away from shore. Although the concentration of road salt in the northeast inlet stream is declining, the plume map and seepage data indicate the groundwater contribution of road salt to the lake is not declining. The findings demonstrate the benefit of combining geophysical and hydrologic data to characterize discharge of a plume beneath Mirror Lake. The extent of the plume in groundwater beneath the lake and stream indicate there will likely be a long-term source of chloride to the lake from groundwater.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laura Toran, Melanie Johnson, Jonathan E. Nyquist, Donald O. Rosenberry. 2010. Delineating a road-salt plume in lakebed sediments using electrical resistivity, piezometers, and seepage meters at Mirror Lake, New Hampshire, U.S.A. https://doi.org/10.1190/1.3467505

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Cooperative joint inversion of magnetotelluric and microseismic data for imaging the Geysers geothermal field, California, USA

The Geysers geothermal field located in northern California, USA, is the world’s largest electricity-generating geothermal facility. To delineate the spatio-temporal distribution of reservoir steam and recharge water, we have collected microseismic and magnetotelluric (MT) data using a dense array of stations in 2021. The microseismic and MT data have been inverted together using a 3D cooperative joint inversion workflow. The joint inversion exploits a cross-gradient structural constraint because electrical conductivity structures observed in the geothermal field are strongly correlated with

California

Inversion of induced polarization-affected towed-transient electromagnetic data in a lateritic regolith geology: A case study from western Tanzania

For several decades, induced polarization (IP) effects on transient electromagnetic (TEM) responses have been observed. These effects can manifest as late-time negative transients or as rapidly decaying curves and are usually associated with highly polarizable bodies. If neglected, IP effects can lead to erroneous resistivity models. Recent work allows IP effects to be incorporated into the inversion of TEM data on a more routine basis. In a recent field survey in western Tanzania, strongly IP-affected TEM signals are observed using a towed-transient electromagnetic (tTEM) system. The survey have been carried out to locate drinking water resources in a weathered regolith setting. In these settings, an inversion of tTEM data using a resistivity-only forward model (i.e., IP neglected) cannot fit the data and severely limits the value of the TEM data for hydrogeologic interpretation. To account for IP effects, we have applied a modified version of the Cole-Cole model called the maximum phase angle (MPA) model to invert IP-affected tTEM data. The MPA model incorporates four inversion model parameters: resistivity ( ⁠ &#x3C1; "> ρ ), MPA ( ⁠ &#x3D5; max "> ϕ max ⁠ ), relaxation time ( ⁠ &#x3C4; "> τ ), and frequency exponent ( ⁠ c "> c ). The MPA model fits the data well and improves the reliability of the resistivity model. In much of the surveyed region, the inverted models using MPA display a three-layer system consisting of an upper resistive laterite layer of varying thickness and an intermediate polarizable conductive unit overlying more resistive weathered basement rocks. The conductive polarizable layer is interpreted as a chemically weathered saprolite separating the surficial and deeper aquifers. Overall, tTEM inversion results provide a local understanding of groundwater systems, especially in such regions with very limited subsurface knowledge.

Kaguruka, Kitagata

Evidence-based guidelines for protective actions and earthquake early warning systems

Earthquake early warning systems (EEW) are becoming increasingly available or in development throughout the world. With public alerting in Mexico, Japan, Taiwan, and parts of the United States, it is important to provide evidence-based recommendations for protective action so people can protect themselves when they receive an alert. Best-practice warning communication research suggests that providing a protective action will increase the efficacy of the message. However, given the diversity of earthquakes and building types, as well as social and cultural contexts where these systems exist, the question is: what is the best protective action to recommend? The answer lies in maximizing life-saving protective actions during an earthquake event requires both contextually relevant messaging and widespread public education about appropriate protective actions under a range of conditions. By researching previous earthquake injury literature, examining current best practices and public education campaigns, key protective actions may be determined and used to increase the life-saving potential of earthquake early warning systems.

Geophysics