Ambient response of a unique performance-based design tall building with dynamic response modification features

Abstract

A 64-story, performance-based design building with reinforced concrete core shear walls and unique dynamic response modification features (tuned liquid sloshing dampers and buckling-restrained braces) has been instrumented with a monitoring array of 72 channels of accelerometers. The responses of the building to ambient motions from ground or wind were recorded and analyzed to identify modes and associated frequencies and damping. Not unexpectedly, the low-amplitude dynamic characteristics are considerably different than those computed from design analyses. Nonetheless, these computed values serve as a baseline against which to compare future strong shaking responses. Such studies help to improve our understanding of the effectiveness of the response modification features at various levels of shaking, to evaluate the predictive capabilities of the design analysis tools and to improve similar designs in the future.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 37.7851815737647° to 37.79113369314532° latitude; -122.39524841308595° to -122.38645076751709° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mehmet Celebi, Moh Huang, Anthony Shakal, John Hooper, Ron Klemencic. 2013-06-06. Ambient response of a unique performance-based design tall building with dynamic response modification features. https://doi.org/10.1002/tal.1093

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Response of a tall building far from the epicenter of the 11 March 2011 M 9.0 Great East Japan earthquake and aftershocks

The 11 March 2011 M 9.0 Great East Japan earthquake generated significant long-duration shaking that propagated hundreds of kilometers from the epicenter and affected urban areas throughout much of Honshu. Recorded responses of a tall building at 770 km from the epicenter of the mainshock and other related or unrelated events show how structures sensitive to long-period motions can be affected by distant sources. Even when the largest peak input motions to the building is about 3% g , the strong-shaking duration was about 140 s. The 300- to 1000-s prolonged responses of the building are primarily due to a combination of site resonance (e.g. structural fundamental frequency ~0.15 Hz and site frequency ~0.13–0.17 Hz) and low damping (~1–2%) of the structure. Response modification technologies can improve the response of the building during future earthquakes. The need-to-consider risks to such built environments from distant sources are emphasized.

Honshu