USGS ScienceSearch

USGS · 70030606

Estimating crustal heterogeneity from double-difference tomography

Abstract

Seismic velocity parameters in limited, but heterogeneous volumes can be inferred using a double-difference tomographic algorithm, but to obtain meaningful results accuracy must be maintained at every step of the computation. MONTEILLER et al. (2005) have devised a double-difference tomographic algorithm that takes full advantage of the accuracy of cross-spectral time-delays of large correlated event sets. This algorithm performs an accurate computation of theoretical travel-time delays in heterogeneous media and applies a suitable inversion scheme based on optimization theory. When applied to Kilauea Volcano, in Hawaii, the double-difference tomography approach shows significant and coherent changes to the velocity model in the well-resolved volumes beneath the Kilauea caldera and the upper east rift. In this paper, we first compare the results obtained using MONTEILLER et al.'s algorithm with those obtained using the classic travel-time tomographic approach. Then, we evaluated the effect of using data series of different accuracies, such as handpicked arrival-time differences ("picking differences"), on the results produced by double-difference tomographic algorithms. We show that picking differences have a non-Gaussian probability density function (pdf). Using a hyperbolic secant pdf instead of a Gaussian pdf allows improvement of the double-difference tomographic result when using picking difference data. We completed our study by investigating the use of spatially discontinuous time-delay data. ?? Birkha??user Verlag, Basel, 2006.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J.-L. Got, V. Monteiller, J. Virieux, P. Okubo. 2006. Estimating crustal heterogeneity from double-difference tomography. https://doi.org/10.1007/s00024-005-0022-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Local variations in broadband sensor installations: Orientations, sensitivities, and noise levels

As seismologists continue to place more stringent demands on data quality, accurately described metadata are becoming increasingly important. In order to better constrain the orientation and sensitivities of seismometers deployed in U.S. Geological Survey networks, the Albuquerque Seismological Laboratory (ASL) has recently begun identifying true north with a fiber optic gyroscope (FOG) and has developed methodologies to constrain mid-band, vertical component sensitivity levels to less than 1% in a controlled environment. However, questions remain regarding the accuracy of this new alignment technique as well as if instrument sensitivities and background noise levels are stable when the seismometers are installed in different environmental settings. In this study, we examine the stability and repeatability of these parameters by reinstalling two high-quality broadband seismometers (Streckeisen STS-2.5 and Nanometrics T-360 Global Seismographic Network (GSN) version) at different locations around the ASL and comparing them to each other and a reference STS-6 seismometer that stayed stationary for the duration of the experiment. We find that even in different environmental conditions, the sensitivities of the two broadband seismometers stayed stable to within 0.1% and that orientations attained using the FOG are generally accurate to within a degree. However, one install was off by 5° due to a mistake made by the installation team. These results indicate that while technology and methodologies are now in place to calibrate and orient a seismometer to within 1°, human error both during the installation and while producing the metadata is often a limiting factor. Finally, we find that background noise levels at short periods (0.1–1 s) become noisier when the sensors are emplaced in unconsolidated materials, whereas the noise levels at long periods (30–100 s) are not sensitive to local geological structure on the vertical components.

Pure and Applied Geophysics

Inter-source interferometry of seismic body waves: Required conditions and examples

Seismic interferometry is widely applied to retrieve wavefields propagating between receivers. Another version of seismic interferometry, called inter-source interferometry, uses the principles of seismic reciprocity and expands interferometric applications to retrieve waves that propagate between two seismic sources. Previous studies of inter-source interferometry usually involve surface-wave and coda-wave estimations. We use inter-source interferometry to estimate the P-waves propagating between two sources rather than the estimation of surface waves and coda waves. We show that the recovered arrival times are dependent on the accuracy of the earthquake catalog of the two sources. Using inter-source interferometry, one can recover the waveform of the direct body waves and potentially reconstruct the waveform of coda waves, depending on the source-receiver geometry. The retrieval of these waveforms is accurate only when the wavefield is sampled with approximately 4 receivers per wavelength in the stationary phase zone. We show that using only receivers inside the stationary phase region for inter-source interferometry introduces the phase error of approximately 0.3 radians. In our study, we show an example of the P-wavefield reconstruction between two earthquakes using the seismic records from an array along San Andreas Fault. The retrieved P waves give a qualitative estimation of the thickness of the low-velocity zone of San Andreas Fault of approximately 4 km.

Pure and Applied Geophysics