USGS · 70018126
Evaluation of immunoassay for the determination of pesticides at a large-scale groundwater contamination site
Abstract
Pesticide concentrations in ground water at Rocky Mountain Arsenal (RMA) near Denver, Colorado, were determined using solid-phase extraction (SPE) gas chromatography/mass spectrometry (GC/MS) procedures and enzyme-linked immunosorbent assay (ELISA) for cyclodiene insecticides and triazine herbicides. Matrix interferences resulted in inconclusive results for some GC/MS analyses due to baseline disturbances and co-elution, but ELISA analyses consistently gave definitive results in a minimum amount of time. ELISA was used initially as a screening method, and pesticide concentrations and plume extents identified by ELISA were confirmed by SPE-GC/MS. A high degree of correlation was seen between results from GC/MS and ELISA methods for the triazine herbicides (correlation coefficient (R 2 ) = 0.99). All areas with high pesticide concentrations were found to be within the boundaries of RMA.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
T. R. Dombrowski, E.M. Thurman, G. B. Mohrman. 2009-07-23. Evaluation of immunoassay for the determination of pesticides at a large-scale groundwater contamination site. https://doi.org/10.1021/bk-1997-0657.ch018
Cite the original work for its findings. Save a collection to share your selection of sources.