Liquefaction during the 1977 San Juan Province, Argentina earthquake (Ms = 7.4)

Abstract

Liquefaction effects generated by the 1977 San Juan Province, Argentina, earthquake (Ms = 7.4) are described. The larger and more abundant effects were concentrated in the 60-km long band of the lowlands in the Valle del Bermejo and in an equally long band along the Rio San Juan in the Valle de Tulum. Fissures in the Valle del Bermejo were up to several hundred meters long and up to several meters wide. Sand deposits, from boils that erupted through the fissures, covered areas up to tens of square meters. Fissures generally parallelled nearby stream channels. Because the Valle del Bermejo is undeveloped, these large features caused no damage. Liquefaction in the Valle del Tulum caused important or unusual damage at several localities, including the following five sites: (1) At the Barrio Justo P. Castro, a subdivision of Caucete, liquefaction of subsurface sediments decoupled overlying, unliquefied stiff sediments, producing a form of ground failure called "ground oscillation". The associated differential ground movements pulled apart houses and pavements in extension, while shearing curbs and buckling canal linings in compression at the same locality. (2) At the Escuela Normal, in Caucete, the roof of a 30-m long single-story classroom building shifted westward relative to the foundation. That displacement fractured and tilted columns supporting the roof. The foundation was fractured at several places, leaving open cracks, as wide as 15 mm. The cumulative width of the open cracks was 48 mm, an amount roughly equivalent to the 63 mm of offset between the roof and foundation at the east end of the building. The ground and foundation beneath the building extended (or spread) laterally opening cracks and lengthening the foundation while the roof remained in place. (3) The most spectacular damage to structures at the community of San Martin was the tilting of a 6-m high water tower and the toppling of a nearby pump house into a 1-m deep crater. Similarly, a small crater developed beneath a hand-pump in an open area and a large, 6-m diameter crater formed nearby. The following sequence of events created the craters and toppled the pump structures: During the earthquake, ground shaking generated excess pore pressures which were dissipated by upward flow of groundwater. Free drainage was restricted by an impermeable plastic-silt layer. Water apparently accumulated below the plastic-silt layer and then burst to the surface through several holes and cracks, including holes around well casings. (4) At the San Isidro winery, nine storage tanks tilted 2 to 5??. Five reinforced-concrete tanks were dismantled but four steel tanks were repaired by placing new footings and jacking the structures into an upright position. (5) At Escuela J.J. Pasos, differential settlement beneath building fractured several columns and walls. The largest settlements were about 60 mm and the maximum settlement of footings supporting columns was about 40 mm. In spite of the damage, the buildings were in no danger of collapse.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: -33.017059210850164° to -29.944571253387238° latitude; -70.29754267074192° to -66.86980829574202° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T. L. Youd, D. K. Keefer. 1994. Liquefaction during the 1977 San Juan Province, Argentina earthquake (Ms = 7.4). https://doi.org/10.1016/0013-7952(94)90057-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Sackung at Bald Eagle ridge, central Colorado: An updated interpretation of ridge-spreading movement, structures, and mechanisms from 50 years (1975–2025) of U.S. Geological Survey research

Slow gravitational failures of mountain peaks and ridges are poorly understood. Herein, we report on 50 years of studies at a slowly spreading castellate ridge in the Sawatch Range in central Colorado. The orientations of geomorphic-structural features indicate that the fractured Precambrian granitic rock underlying the ridge has extended and spread northwestward toward the formerly glacier-covered Busk Creek valley. Results from surveying, field-based geomorphic-structural mapping using lidar, rock mass quality measurements, a passive seismic survey, and satellite radar provide a major update to research started by U.S. Geological Survey researchers in the 1970s and 1980s. New insights include a recognition that the entire ridge has slowly moved by concurrent sliding along an inferred northwest dipping, compound basal-slip surface (or zone), and through the formation of multiple grabens by normal faulting and flexural toppling along sets of pre-existing fractures that dip moderately (∼45°) to the southeast. We were unable to distinguish the presence of a sudden and strong contrast in seismic velocity across the inferred slip surface. Movement during the 50-year study period has been episodic and gradually decreasing, in correspondence with decreasing cumulative annual precipitation and increasing mean annual air temperatures. The fastest moving area, just upslope from the glacier trimline, had an average horizontal velocity of 3 – 4 mm/yr. Evidence suggests that movement started as a paraglacial response mechanism, but because of the site’s proximity to the Rio Grande Rift, we cannot exclude earthquake shaking as a mechanism for initiation or enhancement of slope movement. An estimate of longer-term horizontal movement from the exposed basal-slip surface at the uphill side of the ridgetop graben is ∼1.1 mm/yr for the 13 – 14 ky post-glacial period. Broad implications of our work are that: (1) long-term measurements (decades or longer) of slope movement can add insights into how sackungen form and evolve through time; (2) the identification of thrust faults and toes in zones of compression near valley bottoms can be crucial for interpreting sackung failure mechanisms, and (3) the use of passive-seismic techniques to identify the depth to a slip surface may not be successful in granitic terrain dominated by planar fractures and subtle changes in rock-mass characteristics.

Colorado↗

From landslide susceptibility to risk assessment in the conterminous U.S.

Understanding the spatial distribution of landslide prone-areas and what consequences they may have is important for risk management and land-use planning. In the United States, although landslides occur in every state, a comprehensive landslide risk assessment is still missing. Existing efforts, such as the Federal Emergency Management Agency (FEMA)’s National Risk Index, rely on aggregated products and coarse cartographic units, limiting their geomorphological and practical accuracy. In this study, we present a methodological advance for landslide risk assessment across large areas with incomplete and sparse data. We apply our procedures to the conterminous United States by integrating geomorphologically meaningful partitions and spatial and temporal probability data-driven models. Landslide susceptibility is estimated using a Generalized Additive Mixed Model incorporating a bias capture/correction scheme to account for inventory inaccuracies (reference Area Under the Curve = 0.75). The exceedance probabilities of landslide occurrence are defined for three temporal scenarios (2, 5, and 10 year). Then, we explore the associated potential economic consequences for human settlements and agricultural areas. The findings indicate that the spatial variability of risk is primarily controlled by exposure rather than by susceptibility/hazard alone. The mean risk increases by ∼170% from the 2-year to the 10-year scenario. Beyond its quantitative outcomes, this study offers a blueprint for continental or sub-continental scale landslide risk assessments, demonstrating both the opportunities and current limitations.

Engineering Geology↗

Global patterns of coseismic landslide runout mobility differ from aseismic landslide trends

Coseismic landslides significantly contribute to human and economic losses during and immediately following earthquakes, yet very little data on the runout of such landslides exist. While well-established behavior of aseismic (e.g., hydrologically triggered) landslide runout mobility suggests strong correlation between landslide size and mobility, limited studies of coseismic landslide runout find conflicting mobility trends. We present a global dataset of runout lengths produced from a new automated method for estimating landslide runout, developed and validated using 1726 manually mapped landslides from five unique earthquakes. We then apply the automated runout tool to 23 global earthquake-induced landslide inventories, producing a compiled database of 73,665 measured and estimated runout lengths of coseismic landslides to assess mobility trends. We find a significant divergence between well-established aseismic mobility trends and that of coseismic landslides, with far greater scatter and more complex mobility patterns in earthquake-triggered landslides. As a function of landslide size, we observe global coseismic landslide mobility patterns are bilinear, becoming increasingly less mobile with increasing size above some threshold. This discordance between aseismic and coseismic landslide mobility may be a function of landslide type, kinematics, hydrology, and or setting that systematically differ between triggering mechanisms and should be explored in more depth to develop predictive models of these unique runout patterns. These results suggest hazard and risk models for coseismic landslides may significantly under-predict or over-predict impacts, depending on the size of triggered landslides.

Engineering Geology↗