USGS ScienceSearch

USGS · 70014844

Borehole field calibration and measurement of low-concentration manganese by decay gamma rays

Abstract

The manganese concentration in the Arundel clay formation, Prince Georges County, Maryland, was determined from a borehole by using delayed neutron activation. The neutrons were produced by a 100 mu g 252 Cf source. The 847 keV gamma ray of manganese was detected continuously, and its counting rate was measured at intervals of 15 s as the measuring sonde was moved at a rate of 0.5 cm/s. The technique measured the concentration ratio of manganese to aluminum. This ratio, when combined with an estimate of the aluminum concentration of the clay, made it possible to determine the percentage concentration of manganese without using a test-pit calibration facility. The measurements were made by using an NaI(Tl) scintillation detector and a Ge(HP) solid-state detector cooled by solid propane. A two-pass technique had to be used with the scintillation detector because Compton background from the 1 779 keV photopeak of aluminum masked the manganese line. The Compton background did not interfere when the solid-state detector was used. The borehole measurements compared favorably with a chemical core analysis and were unaffected by water in the borehole.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J.L. Mikesell, F. E. Senftle, T.A. Lloyd, A. B. Tanner, C.T. Merritt, E. R. Force. 1986. Borehole field calibration and measurement of low-concentration manganese by decay gamma rays. https://doi.org/10.1190/1.1442075

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Cooperative joint inversion of magnetotelluric and microseismic data for imaging the Geysers geothermal field, California, USA

The Geysers geothermal field located in northern California, USA, is the world’s largest electricity-generating geothermal facility. To delineate the spatio-temporal distribution of reservoir steam and recharge water, we have collected microseismic and magnetotelluric (MT) data using a dense array of stations in 2021. The microseismic and MT data have been inverted together using a 3D cooperative joint inversion workflow. The joint inversion exploits a cross-gradient structural constraint because electrical conductivity structures observed in the geothermal field are strongly correlated with

California

Inversion of induced polarization-affected towed-transient electromagnetic data in a lateritic regolith geology: A case study from western Tanzania

For several decades, induced polarization (IP) effects on transient electromagnetic (TEM) responses have been observed. These effects can manifest as late-time negative transients or as rapidly decaying curves and are usually associated with highly polarizable bodies. If neglected, IP effects can lead to erroneous resistivity models. Recent work allows IP effects to be incorporated into the inversion of TEM data on a more routine basis. In a recent field survey in western Tanzania, strongly IP-affected TEM signals are observed using a towed-transient electromagnetic (tTEM) system. The survey have been carried out to locate drinking water resources in a weathered regolith setting. In these settings, an inversion of tTEM data using a resistivity-only forward model (i.e., IP neglected) cannot fit the data and severely limits the value of the TEM data for hydrogeologic interpretation. To account for IP effects, we have applied a modified version of the Cole-Cole model called the maximum phase angle (MPA) model to invert IP-affected tTEM data. The MPA model incorporates four inversion model parameters: resistivity ( ⁠ ρ "> ρ ), MPA ( ⁠ ϕ max "> ϕ max ⁠ ), relaxation time ( ⁠ τ "> τ ), and frequency exponent ( ⁠ c "> c ). The MPA model fits the data well and improves the reliability of the resistivity model. In much of the surveyed region, the inverted models using MPA display a three-layer system consisting of an upper resistive laterite layer of varying thickness and an intermediate polarizable conductive unit overlying more resistive weathered basement rocks. The conductive polarizable layer is interpreted as a chemically weathered saprolite separating the surficial and deeper aquifers. Overall, tTEM inversion results provide a local understanding of groundwater systems, especially in such regions with very limited subsurface knowledge.

Kaguruka, Kitagata

Evidence-based guidelines for protective actions and earthquake early warning systems

Earthquake early warning systems (EEW) are becoming increasingly available or in development throughout the world. With public alerting in Mexico, Japan, Taiwan, and parts of the United States, it is important to provide evidence-based recommendations for protective action so people can protect themselves when they receive an alert. Best-practice warning communication research suggests that providing a protective action will increase the efficacy of the message. However, given the diversity of earthquakes and building types, as well as social and cultural contexts where these systems exist, the question is: what is the best protective action to recommend? The answer lies in maximizing life-saving protective actions during an earthquake event requires both contextually relevant messaging and widespread public education about appropriate protective actions under a range of conditions. By researching previous earthquake injury literature, examining current best practices and public education campaigns, key protective actions may be determined and used to increase the life-saving potential of earthquake early warning systems.

Geophysics