The representativeness of pore water samples collected from the unsaturated zone using pressure-vacuum lysimeters

Abstract

Pressure-vacuum lysimeters are an inexpensive means of collecting numerous water samples from the same location in the unsaturated zone over a period of time. However, prior studies have indicated that the chemistry of water samples may be altered by the collection technique, creating concern about the representativeness of the pore water samples obtained. A study conducted using soil water pressure-vacuum lysimeters in outwash sand and glacial till deposits demonstrates that for non-dilute-solution samples the effect on pH of sampling with lysimeters is minimal, and that measured major cation and anion concentrations are representative of the natural pore water; trace-metal concentrations can be significantly altered by collection procedures at low concentrations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Charles A. Peters, Richard W. Healy. 2007-02-22. The representativeness of pore water samples collected from the unsaturated zone using pressure-vacuum lysimeters. https://doi.org/10.1111/j.1745-6592.1988.tb00995.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Use of on-site high performance liquid chromatography to evaluate the magnitude and extent of organic contaminants in aquifers

Appraisal of ground water contaminated by organic substances raises problems of difficult sample collection and timely chemical analysis. High-performance liquid chromatography was evaluated for on-site determination of specific organic contaminants in ground water samples and was used at three study sites. Organic solutes were determined directly in water samples, with little or no preparation, and usually in less than an hour after collection. This information improved sampling efficiency and was useful in screening for subsequent laboratory analysis. On two occasions, on-site analysis revealed that samples were undergoing rapid change, with major solutes being upgraded and alteration products being formed. In addition to sample stability, this technique proved valuable for monitoring other sampling factors such as compositional changes with respect to pumping, filtration, and cross contamination. -Authors

Ground Water Monitoring Review↗

Screening of ground water samples for volatile organic compounds using a portable gas chromatograph

A portable gas chromatograph was used to screen 32 ground water samples for volatile organic compounds. Seven screened samples were positive; four of the seven samples had volatile organic substances identified by second-column confirmation. Four of the seven positive, screened samples also tested positive in laboratory analyses of duplicate samples. No volatile organic compounds were detected in laboratory analyses of samples that headspace screening indicated to be negative. Samples that contained volatile organic compounds, as identified by laboratory analysis, and that contained a volatile organic compound present in a standard of selected compounds were correctly identified by using the portable gas chromatograph. Comparisons of screened-sample data with laboratory data indicate the ability to detect selected volatile organic compounds at concentrations of about 1 microgram per liter in the headspace of water samples by use of a portable gas chromatograph.

Ground Water Monitoring Review↗

Comparison of downhole and surface sampling for the determination of volatile organic compounds (VOCs) in ground water

The relative precision and accuracy of sampling and analysis methods for the determination of trace concentrations of volatile organic compounds (VOCs) in ground water were compared. Samples were collected from a well containing nanogram‐per‐liter (ng/L) to microgram‐per‐liter (μg/L) levels of VOCs. A Keck helical rotor submersible pump was used to collect samples at the surface for analysis by purge and trap (P&T) and for analysis by adsorption/thermal desorption (ATD). Downhole samples were collected by passing water through an ATD cartridge. Although slight spontaneous bubble outgassing occurred when the water was brought to the surface, the relative precisions and comparabilities of the surface and downhole methods were generally found to be equivalent from a statistical point of view. A main conclusion of this study is that bringing sample water to the surface for placement in VOC vials (and subsequent analysis by P&T) can be done reliably under many circumstances. However, care must still be taken to prevent adsorption losses and cross contamination. Samples subject to strong bubble outgassing will need to be handled in a special fashion (e.g., by downhole ATD) to minimize volatilization losses. Additionally, the higher sensitivity of the ATD method allows lower detection limits than are possible with P&T. For example, several compounds present at the ng/L level could be determined with confidence by ATD, but not by P&T.

New Jersey↗