Abstract

The use of internal standards in the analysis of ores and minerals of widely-varying matrix by means of fluorescent X-ray spectroscopy is frequently the most practical approach. Internal standards correct for absorption and enhancement effects except when an absorption edge falls between the comparison lines or a very strong emission line falls between the absorption edges responsible for the comparison lines. Particle size variations may introduce substantial errors. One method of coping with the particle size problem is grinding the sample with an added abrasive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I. Adler, J. M. Axelrod. 1955. Internal standards in fluorescent X-ray spectroscopy. https://doi.org/10.1016/0371-1951(55)80011-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Double-chamber electrode for spectrochemical determination of chlorine and other halogens

A double-chamber, graphite electrode, suitable for d.c. arc determination of halogens by means of the alkaline earth halide bands, is described. An upper chamber holds the alkaline earth compound and an interconnected, lower chamber holds the halogen compound. This arrangement assures that there will be an abundance of alkaline earths in the arc by the time the halogen is volatilized from the lower chamber, and thereby promotes maximum emission of the alkaline earth halide bands.

Spectrochimica Acta

Spectrochemical determination of thorium in monazite by the powder-d.c. arc technique

Thorium in monazite is determined by a d.c. carbon-arc technique using zirconium as the internal standard. The analytical curve for Th II 2870.413 Å/Zr II 2844-579 Å is established by means of synthetic standards containing graduated amounts of thoria and 0.500 per cent zirconia in pegmatite base (60 parts quartz, 40 parts microchne, and 1 part ferric oxide). Monazite samples are diluted 14-fold with pegmatite base that contains 0.538 per cent ZrO 2 , so that the zirconia content of the resulting mixture is also 0.500 per cent. In addition, both the standards and the diluted monazites are mixed with one-half their weight of powdered graphite. Approximately 25 mg of the prepared samples are arced to completion at 15.5 to 17.5 amperes. With the 14-fold dilution employed, the accurate range of the method is 3 to 20 per cent thoria in the original monazite. The coefficient of variation for a single determination is 4 per cent at the 7 per cent thoria level. Tests with synthetic unknowns and chemically analyzed monazites show a maximum error of ±10 per cent of the thoria content. If niobium is substituted for zirconium as the internal standard, there is a loss of precision. Platinum as the internal standard gives results of good precision but introduces a marked sensitivity to matrix effects.

Spectrochimica Acta