USGS Science⌕ Search

Geology topics

Research about Texas

Source-linked reports with geographic coverage including Texas.

At least 1,135 records · Page 63Linked to original sources

Preliminary data describing the distribution of fluoride and silica in the water in the Ogallala aquifer on the High Plains of Texas

The Ogallala aquifer of Texas historically has been known for elevated fluoride concentration, with many areas in excess of 4 milligrams per liter. In addition, on a regional scale, silica concentrations are also somewhat elevated, with concentrations averaging in the 40 to 50 milligrams per liter range. This aquifer provides a unique geochemical and epidemiological study area because it is completely contained within the High Plains physiographic province.

Texas↗

Hydrologic data for urban studies in the Austin, Texas metropolitan area, 1978

Hydrologic investigations of urban watersheds in Texas were begun by the U.S. Geological Survey in 1954. Studies are now in progress in Austin, Dallas, Dallas County, Fort Worth, Houston, and San Antonio. The Geological Survey, in cooperation with the Texas Department of Water Resources, began hydrologic studies in the Austin urban area in 1954. In cooperation with the city of Austin, the program was expanded in 1975 to include additional streamflow and rainfall gaging stations and the collection of water-quality data. In 1978, the program was expanded to include a ground-water resources study of the South Austin metropolitan area in the Balcones Fault Zone.

Texas↗

Hydrologic data for urban studies in the San Antonio, Texas, metropolitan area, 1977

Hydrologic investigations of urban drainage basins in Texas were begun by the U.S. Geological Survey in 1954. These studies are now in progress in Austin, Dallas, Dallas County, Fort Worth, Houston, and San Antonio. The Geological Survey, in cooperation with the Texas Department of Water Resources, expanded the existing gaging-station network in the San Antonio metropolitan area in May 1968 to begin urban hydrology studies in this area. In September 1968, the program was further expanded to include the collection of water-quality data. The operation and maintenance of stations 08178000, San Antonio River at San Antonio; 08178700, Salado Creek (upper station) at San Antonio; and 08178800, Salado Creek (lower station) at San Antonio are funded by the San Antonio River Authority in cooperation with the Texas Department of Water Resources and the U.S. Geological Survey. The operation and maintenance and collection of water-quality data at station 08178640, West Elm Creek at San Antonio, and station 08178645, East Elm Creek at San Antonio are funded by the Edwards Underground Water District in cooperation with the Texas Department of Water Resources and the U.S. Geological Survey. These stations will provide hydrologic data on similar and adjacent drainage basins. One drainage basin is undergoing extensive urbanization while the other is undeveloped. The objective of the San Antonio urban-hydrology study are: To provide data showing the effects of various stages of urbanization on flood discharge and runoff. To provide water-quality data on surface-water runoff from floods of various magnitudes, during all seasons of the year from areas with different types of utilization.

Texas↗

Hydrologic data for Mountain Creek, Trinity River basin, Texas, 1978

The collection of hydrologic data by the U.S. Geological Survey in the Mountain Creek watershed began on March 9, 1925, with the establishment of a stream-gaging station located about 2.5 miles upstream from the present site of Mountain Creek Lake Dam. The stream-gaging station was discontinued on July 5, 1933. Daily streamflow records obtained at this site are published in the annual series of Geological Survey water supply papers beginning in 1925. Monthly and yearly summaries are published in Water-Supply Paper 1312. In October 1960, the Geological Survey resumed collection of hydrologic data in the Mountain Creek watershed by establishing three stream gaging stations and one reservoir-content station. The data-collection sites are on Mountain Creek near Cedar Hill (station 08049600), Walnut Creek near Mansfield (station 08049700), Mountain Creek at Grand Prairie (station 08050100), and Mountain Creek Lake near Grand Prairie (station 08050050; fig. 1). In October 1970, the Geological Survey assumed operation of the stage station Mountain Creek near Duncanville (station 08049900; fig. 1). Since 1974 water-quality data has been collected at varying periodic intervals at the sites near Cedar Hill, near Duncanville, and Mountain Creek Lake since 1969. These water-quality data collection stations are shown on figure 1.

Texas↗

Technique for estimating the magnitude and frequency of floods in the Houston, Texas, Metropolitan Area

A technique for estimating the magnitude and frequency of floods in the Houston, Texas, metropolitan area was developed by use of a multiple-regression flood-frequency analysis of flow data from unregulated streams in the area. A regression model, relating flood-peak discharge to concurrent rainfall and antecedent soil moisture conditions, was used to simulate 67-year records of annual peak discharges. Flood-frequency characteristics were determined for the simulated annual peaks and for the observed annual peaks at each of 22 gaging stations. Drainage area, bank-full channel conveyance, and percentage of urban development were used as independent variables; and weighted flood-frequency discharges were used as dependent variables in the multiple regression analysis. Relationships applicable to unregulated streams were developed for predicting floods with recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years. Drainage basins ranged in area from 1.33 to 182 square miles. The percentage of urban development in these basins ranges from 37 to 98.9 percent. The relationships indicate that as a basin changes from a completely natural state to one of complete urbanization, the magnitude of a 2-year peak discharge is increased by a factor of 4.2, the magnitude of a 50-year peak is increased by a factor of 4.9, and the magnitude of a 100-year peak is increased by a factor of 4. 9.

Texas↗

Effects of the rate of releases from Sam Rayburn Reservoir on the aeration capacity of the Angelina River, eastern Texas

A three-phase study was conducted during July and August 1979 to determine the effects of varying release rates through the power-outlet works at Sam Rayburn Reservoir, eastern Texas, on aeration capacity of a 14-mile reach of the Angelina River below Sam Rayburn Dam. The dominant factors that affected the aeration capacity during the study time were time of travel and the dissolved-oxygen deficit of the releases. Aeration was low throughout the study but increased in response to increases in the dissolved-oxygen deficit and the duration of time that the releases were exposed to the atmosphere (time of travel). The average concentration of dissolved oxygen sustained by release of 8,800 cubic feet per second decreased from 5.0 milligrams per liter at a site near the power outlet to 4.8 milligrams per liter at a site about 14 miles downstream; the time of travel averaged about 8 hours. The average concentration of dissolved oxygen in flow sustained by releases of 2,200 cubic feet per second increased from 5.2 to 5.5 milligrams per liter; the time of travel averaged about 20 hours.

Texas↗

Development of Ground Water in the Houston District, Texas, 1970-1974

Total withdrawals of ground water in the Houston district increased 9 percent from about 488 million gallons per day (21.4 cubic meters per second) in 1970 to about 532 million gallons per day (23.3 cubic meters per second) in 1974. The average annual rate of increase from 1960 to 1969 was about 6.3 percent. During 1970-74, increases in pumpage occurred in the Houston, Katy, and NASA areas; decreases occurred in the Pasadena and Alta Lorna areas; and the pumpage in the Baytown-La Porte and Texas City areas remained almost constant.

Texas↗

Ground-water data for the Salt Basin, Eagle Flat, Red Light Draw, Green River Valley and Presidio Bolson in westernmost Texas

From October 1971 through October 1974. the U.S. Geological Survey collected ground-water data in the basins in Texas west of the Pecos River drainage area and northwest of the Big Bend country. The basins included are, from east to west: The Presidio Bolson; the Salt Basin; Green River Valley, Eagle Flat, and Red Light Draw. These data, which were collected in cooperation with the Texas Department of Water Resources (formerly Texas Water Development Board), will provide information for a continuing assessment of water availability within the State.

Texas↗

Parathion causes secondary poisoning in a laughing gull breeding colony

Use of organophosphate insecticides as replacements for the more persistent organochlorine compounds has increased dramatically in recent years. Organophosphates are desirable for field application because they break down rapidly in the environment and do not persist in animal tissues (Stickel 1974). Nevertheless, certain organophosphates are extremely toxic to wildlife for short periods after application and have caused widespread mortality among exposed animals (Mills 1973, Stickel 1974, 1975, Mendelssohn 1977, and Zinkl et al. 1978).

Texas↗

Effects of oil transferred from incubating gulls to their eggs

No. 2 fuel oil, or water, was applied to the breast feathers of incubating laughing gulls trapped at their nest site on an island colony in Texas. Gulls were released after treatment and allowed to incubate their eggs for 5 days. Oil was transferred from the feathers of incubating adults to their eggs and resulted in 41% embryo mortality compared with 2% in controls.

Texas↗

Surface faults in the gulf coastal plain between Victoria and Beaumont, Texas

Displacement of the land surface by faulting is widespread in the Houston-Galveston region, an area which has undergone moderate to severe land subsidence associated with fluid withdrawal (principally water, and to a lesser extent, oil and gas). A causative link between subsidence and fluid extraction has been convincingly reported in the published literature. However, the degree to which fluid withdrawal affects fault movement in the Texas Gulf Coast, and the mechanism(s) by which this occurs are as yet unclear. Faults that offset the ground surface are not confined to the large (>6000-km 2 ) subsidence “bowl” centered on Houston, but rather are common and characteristic features of Gulf Coast geology. Current observations and conclusions concerning surface faults mapped in a 35,000-km 2 area between Victoria and Beaumont, Texas (which area includes the Houston subsidence bowl) may be summarized as follows: (1) Hundreds of faults cutting the Pleistocene and Holocene sediments exposed in the coastal plain have been mapped. Many faults lie well outside the Houston-Galveston region; of these, more than 10% are active, as shown by such features as displaced, fractured, and patched road surfaces, structural failure of buildings astride faults, and deformed railroad tracks. (2) Complex patterns of surface faults are common above salt domes. Both radial patterns (for example, in High Island, Blue Ridge, Clam Lake, and Clinton domes) and crestal grabens (for example, in the South Houston and Friendswood-Webster domes) have been recognized. Elongate grabens connecting several known and suspected salt domes, such as the fault zone connecting Mykawa, Friendswood-Webster, and Clear Lake domes, suggest fault development above rising salt ridges. (3) Surface faults associated with salt domes tend to be short (<5 km in length), numerous, curved in map view, and of diverse trend. Intersecting faults are common. In contrast, surface faults in areas unaffected by salt diapirism are frequently mappable for appreciable distances (>10 km), occur singly or in simple grabens, have gently sinuous traces, and tend to lie roughly parallel to the ENE-NE “coastwise” trend common to regional growth faults identified in subsurface Tertiary sediments. (4) Evidence to support the thesis that surface scarps are the shallow expression of faults extending downward into the Tertiary section is mostly indirect, but nonetheless reasonably convincing. Certainly the patterns of crestal grabens and radiating faults mapped on the surface above salt domes are more than happenstance; analogous fault patterns have been documented around these structures at depth. Similarly, some of the long surface faults not associated with salt domes seem to have subsurface counterparts among known regional growth faults documented through well logs and seismic data. Correlations between surface scarps and faults offsetting subsurface data are not conclusive because of the large vertical distances (1900- 3800 m) involved in making the most of the inferred connections. Nevertheless, the large number of successful correlations - in trend, movement sense, and position - suggests that many surface scarps represent merely the most recent displacements on faults formed during the Tertiary. (5) Upstream-facing fault scarps in this region of low relief can be significant impediments to streams. Locally, both abandoned, mud-filled Pleistocene distributary channels and, more commonly, Holocene drainage lines still occupied by perennial streams reflect the influence of faulting on their development. Some bend sharply near faults and have tended to flow along or pond against the base of scarps; others meander within topographically expressed grabens. Such evidence for Quaternary displacement of the ground surface is widespread in the Texas Gulf coast. In the general, however, streams in areas now offset by faulting show no disruption of their courses where they cross fault scarps. Such scarps are probably very young, and where they can be demonstrated to partly or wholly predate fluid withdrawal, very recent natural fault activity is indicated. (6) Early aerial photographs (1930) of the entire region and topographic maps (1915-16 surveys) of Harris County (Houston and vicinity) show that many faults had already displaced the land surface at a time when appreciable pressure declines in subjacent strata were localized to relatively few areas of large-scale pumping. Prehistoric faulting of the land surface, as noted above, appears to have affected much of the Texas Gulf Coast. (7) A relation between groundwater extraction and current motion on active faults is suspected because of the increased incidence of ground failure in the Houston-Galveston subsidence bowl. This argument is weakened somewhat by recognition of numerous surface faults, some of them active today, far beyond the periphery of the strongly subsiding area. Moreover, tilt beam records from two monitored faults in northwest Houston and accounts of fault damage from local residents demonstrate a complex, episodic nature of fault creep which can only partially be correlated with groundwater production. Nevertheless, although specific mechanisms are in doubt, the extraction of groundwater from shallow (<800-m) sands is probably a major factor in contributing to current displacement of the ground surface in the Houston-Galveston region. Within this large area, the number of faults recognizable from aerial photographs has increased at least tenfold between 1930 and 1970. Elsewhere in the Texas Gulf Coast only a moderate increase has been noted, some of which is possibly attributable to oil and gas production. Surface fault density in the Houston-Galveston region is far greater than in any other area of the Texas Gulf Coast investigated to date. A plausible explanation for these differences is that large overdrafts of groundwater over an extended period of time in the Houston-Galveston region have stimulated fault activity there. Throughout the Texas Gulf Coast, however, a natural contribution to fault motion remains a distinct possibility.

Texas↗

Weights of lesser snow geese taken on their winter range

Geese are assumed to accumulate fat on the winter range (Bent 1962, Williams 1967) to sustain them through the long northward migration and early part of the nesting season. However, there are no weights given in the literature of lesser snow geese ( Anser c. caerulescens ) on their winter ranges to compare with weights on the breeding grounds. For many years biologists relied on Kortright (1942) for weights of lesser snow geese, and more recently on Bellrose (1976). In the present study, snow geese from the Garwood Prairie, a rice growing area in Colorado County, Texas, were weighed to determine if weights increased before northward migration. The Garwood Prairie is a segment of the snow goose winter range near the Gulf Coast of Texas.

Texas↗

Effects of aldrin exposure on snow geese in Texas rice fields

In 1972 and 1974, 112 dead or moribund snow geese ( Chen c. caerulescens ), mostly immature white-phase males, were found in a study area on the Garwood Prairie, Texas. Dying geese were observed within 2 days after rice fields planted with aldrin-treated seed were flooded by heavy tains6n 21 March 1972 and 25 March 1974. Brains from 8 snow geese that were moribund when found contained an average of 8.2 ppm (4.9-14.0 ppm) of dieldrin (a metabolite of aldrin); brains of 14 geese found dead contained an average of 14.1ppm (2.1-31 ppm). Because no mortalities occurred in 1973 when aldrin-treated rice seed was flooded after all geese had migrated or in 1975 and 1976 after the treatment of rice seed with aldrin was suspended, it appears certain that aldrin caused the mortalities.

Texas↗

Maps showing late Pleistocene and Holocene evolution of the South Texas continental shelf

Interpretation of acoustical profiles has provided insight into the late Quaternary geologic history of the Continental Shelf off South Texas. (See the geographic index map on sheet 1 for location of the area studied.) The profiles reveal the interplay of tectonism, sedimentation, and cyclic fluctuations of sea level in the building and geologic evolution of the continental terrace. The sequence of sediments studied extends to about 200 meters (m) beneath the sea-floor surface. Four seismic-stratigraphic units underlain by four prominent sound reflectors were identified and mapped. This geologic synthesis, for which the research was funded by the U.S. Bureau of Land Management (BLM), is but one aspect of a coordinated, multidisciplinary environmental study of the South Texas Outer Continental Shelf sponsored by BLM (Berryhill, 1976, 1977). The environmental studies are keyed to the leasing of Federal Outer Continental Shelf (OCS) lands for petroleum exploration and production. Their purpose is to provide the data development of petroleum resources on the OCS, as well as to provide the basis for predicting the impact of oil and gas exploration and production on the marine environment. Of primary concern is the recognition of geologic conditions that might be hazardous to structures placed on the sea floor. Geologic hazards relate directly to the potential for significant movement of the sea floor in the future. Judging sea-floor stability and recognizing geologic features that are potentially hazardous require an understanding of the recent geologic history of the area, which, in turn, entails determining the relative rates and interactions of sedimentation and tectonism through time. In addition to the primary objective, the synthesis provides knowledge about the magnitude and extent of sea-level fluctuations in the western Gulf of Mexico, and it provides a depositional facies model of possible use in appraising the resource potential of the more deeply buried sediments.

Texas↗

Faults in parts of north-central and western Houston metropolitan area, Texas

Hundreds of residential, commercial, and industrial structures in the Houston metropolitan area have sustained moderate to severe damage owing to their locations on or near active faults. Paved roads have been offset by faults at hundreds of locations, butted pipelines have been distorted by fault movements, and fault-induced gradient changes in drainage lines have raised concern among flood control engineers. Over 150 faults, many of them moving at rates of 0.5 to 2 cm/yr, have been mapped in the Houston area; the number of faults probably far exceeds this figure. This report includes a map of eight faults, in north-central and western Houston, at a scale useful for land-use planning. Seven of the faults, are known, to be active and have caused considerable damage to structures built on or near them. If the eighth fault is active, it may be of concern to new developments on the west side of Houston. A ninth feature shown on the map is regarded only as a possible fault, as an origin by faulting has not been firmly established. Seismic and drill-hold data for some 40 faults, studied in detail by various investigators have verified connections between scarps at the land surface and growth faults in the shallow subsurface. Some scarps, then, are known to be the surface manifestations of faults that have geologically long histories of movement. The degree to which natural geologic processes contribute to current fault movement, however, is unclear, for some of man’s activities may play a role in faulting as well. Evidence that current rates of fault movement far exceed average prehistoric rates and that most offset of the land surface in the Houston area has occurred only within the last 50 years indirectly suggest that fluid withdrawal may be accelerating or reinitiating movement on pre-existing faults. This conclusion, however, is based only on a coincidence in time between increased fault activity and increased rates of withdrawal of water, oil, and gas from subsurface sediments; no cause-and-effect relationship has been demonstrated. An alternative hypothesis is that natural fault movements are characterized by short—term episodicity and that Houston is experiencing the effects of a brief period of accelerated natural fault movement. Available data from monitored faults are insufficient to weigh the relative importance of natural vs. induced fault movements.

Texas↗