USGS ScienceSearch

Geology topics

Research about Storrs, Connecticut

Source-linked reports with geographic coverage including Storrs, Connecticut.

5 recordsLinked to original sources

Borehole-geophysical and hydraulic investigation of the fractured-rock aquifer near the University of Connecticut Landfill, Storrs, Connecticut, 2000 to 2001

An integrated borehole-geophysical and hydraulic investigation was conducted at the former landfill area near the University of Connecticut in Storrs, Connecticut, where solvents and landfill leachate have contaminated a fractured-bedrock aquifer. Borehole-geophysical techniques and hydraulic methods were used to characterize the site bedrock lithology and structure, fractures, and hydraulic properties. The geophysical and hydraulic methods included conventional logs, borehole imaging, borehole radar, flowmeter under ambient- and stressed hydraulic conditions, and discrete-zone hydraulic testing, sampling, and monitoring. The conventional geophysical-logging methods included caliper, deviation, electromagnetic induction, gamma, specific conductance, and fluid temperature. The advanced methods included optical and acoustic imaging of the borehole wall, heat-pulse flowmeter, and directional radar reflection. Borehole-geophysical methods were used to further define conductive features identified with surface-geophysical methods in the first phase of the investigation. The results of the surface- and borehole-geophysical logging were evaluated in an iterative and integrated manner to develop a conceptual model of ground-water flow at the site. The rock type, foliation, and fractures at the site were characterized from high-resolution optical televiewer (OTV) images of rocks penetrated by the boreholes and were compared to drilling logs and conventional geophysical logs. The rocks are interpreted as fine- to mediumgrained quartz-feldspar-biotite-garnet gneiss and schist with local intrusions of quartz diorite and pegmatite and minor concentrations of sulfide mineralization similar to rocks described as the Bigelow Brook Formation on regional geologic maps. Layers containing high concentrations of sulfide minerals appear as high electrical conductivity zones on electromagnetic-induction and borehole-radar logs. Foliation in the rocks generally strikes to the southwest and northeast, and dips to the northwest and southeast consistent with previous investigations in this area. The orientation of foliation, however, varies locally and with depth in some of the boreholes. These results are consistent with geologic mapping that has identified small-scale folding. The orientations of the transmissive fractures identified in the six boreholes logged for this investigation are similar to the fracture orientations mapped in a previous investigation. Many of these fractures are oriented with a north-northwest strike and have a shallow dip to the west. Other transmissive fractures have a southwest strike and dip at shallow angles to the northwest, and some strike roughly east-west and dip to the north and south. Flowmeter logging was used to identify transmissive fractures and to estimate the hydraulic properties in the boreholes. Ambient down flow was measured in one borehole, and ambient up flow and down flow were measured in another borehole. The other four bedrock boreholes did not have measurable vertical flow. Under low-rate pumping conditions (0.25 to 0.5 gallons per minute), one to three inflow zones were identified in each well. Commonly, fractures that are active under ambient conditions contribute to the well under pumping conditions. The ambient conditions were incorporated into the determination of the relative proportions of transmissivity. Specific capacity and transmissivity were determined for these open-hole low-rate pumping tests. Quasi-steady-state water levels were reached in four of the boreholes, including MW201R, MW204R, MW302R, and W202-NE. When pumped at low-rate conditions for 0.5 to 4 hours, the specific capacity ranged from 0.03 to 0.18 gallons per minute per foot. The open-hole transmissivity estimates ranged from 4.9 to 30 feet squared per day (ft2/d). Open-hole transmissivity was determined for boreholes that did not reach quasi-steady-state conditions under low-rate pumping conditions. Transmissivity was estimated for MW201R, MW202R, and MW203R using non-equilibrium methods, pumping rate, and the transient drawdown data to estimate the open-hole transmissivity. Transmissivity in these boreholes ranged from 0.98 to 3.2 ft 2 /d. The transmissivity and head of individual fractures or zones of fractures were estimated from heat-pulse flowmeter data acquired under ambient and stressed conditions. In the absence of ambient flow, data from two profiles of heat-pulse flowmeter data under two different stressed conditions were used to estimate the transmissivity and head of individual fracture zones. Only two boreholes, MW302R and W202-NE, had sufficient data for these analyses. The estimated transmissivity of individual transmissive zones ranged from 1.2 to 9.2 ft 2 /d. The transmissivity values determined by this numerical simulation method were less than the open-hole estimations, which were 15 and 30 ft 2 /d. Transmissivity also was measured directly over discrete intervals of the borehole using a straddle-packer apparatus and constant-rate pumping tests. Pumping rates were less than or equal to 0.25 gallons per minute. These discretezone single-hole pumping tests were conducted over a short period of time, usually about 30 minutes to 1 hour in duration. Pumping continued until the test zone reached a steady-state water level or until it was determined that the zone could not yield water at the pumped rate. The estimated transmissivity of individual transmissive zones ranged from about 0.21 to 11 ft 2 /d. The zone at a depth of 197 feet in W202-NE was the only zone that had discrete-interval testing with a straddle packer and sufficient heat-pulse flowmeter data for modeling the flow and estimating transmissivity and head. The two methods produced similar results. The straddle-packer method estimated a transmissivity of 4.7 ft 2 /d, and the heat-pulse flowmeter modeling results estimated a transmissivity of 6.9 ft 2 /d. A comparison of the transmissivity estimates indicate estimates typically are within an order of magnitude. The heat-pulse flowmeter methods used in this investigation to determine transmissivity of the boreholes and the individual fractures measure only the upper two or three orders of magnitude of transmissivity. Hence, other fractures in these boreholes permit the movement of water; their transmissivities, however, are lower than the detection limits of the methods that were used for this investigation and very small compared to the transmissive fractures that were studied. The data collected in this investigation were used to design discrete-zone monitoring systems for four of the boreholes used for monitoring. The results of the investigation are useful for refining the conceptual site model of ground-water flow, and for providing critical information for interpreting the results of water-quality sampling.

Connecticut

Use of discrete-zone monitoring systems for hydraulic characterization of a fractured-rock aquifer at the University of Connecticut Landfill, Storrs, Connecticut, 1999 to 2002

The U.S. Geological Survey, in cooperation with the University of Connecticut, used a suite of hydraulic methods to characterize the hydrogeology of a fractured-rock aquifer near the former landfill and chemical-waste disposal pits at the University of Connecticut, Storrs, Connecticut. Multiple methods were used to determine head, driving potential, and transmissivity, including manual open-hole water-level and discretezone water-level measurements from 11 boreholes; continuous discrete-zone water-level measurements from 6 of the boreholes; estimated head and transmissivity for 11 boreholes using heat-pulse flowmeter profiles and pumping records; and differential head testing using a straddle-packer apparatus from 4 boreholes. These data were analyzed to identify and characterize relations between long-term water-level patterns and precipitation, topographic setting, contaminant distribution at the site, and a conceptual ground-water flow model. Data collected using the heat-pulse flowmeter, the straddle-packer apparatus, and discrete-zone monitoring (DZM) systems helped to establish, refine, and verify a conceptual model of ground-water flow in the study area. Monitoring of DZM systems installed in 11 boreholes provided a method for longterm monitoring of hydraulic head and water quality of the aquifer at fracture zones of different depths. These data were used to help define the conceptual site model for ground-water flow and to determine and explain the distribution of contamination. Hydrographs constructed for discretely isolated zones in the boreholes showed the magnitude of seasonal changes of water levels and driving potential in response to precipitation and drought. Heads in discrete zones and in different boreholes varied both in magnitude of response and in timing of response to precipitation. Water levels in open boreholes and in DZM systems showed a semi-diurnal pattern that coincides with gravimetric tidal plots generated for this area. No fluctuations that might indicate pumping were identified in the continuous water-level records. Lack of hydraulic response between boreholes during cross-hole testing in the area of the former chemical-waste disposal pits indicates poor hydraulic connection between the boreholes that were tested. In general, data indicated the presence of downward driving potentials in the recharge areas and in the area of the ground-water divide, and upward driving potentials in discharge areas north and south of the landfill. The results of this study illustrate the importance of discrete-zone isolation and monitoring in fractured-rock aquifers to prevent cross contamination while permitting head measurements and water-quality sampling that can be used to identify and characterize contamination or pathways for contaminant migration in a fractured-rock aquifer. Without DZM systems installed in the boreholes, only open-hole heads can be measured. The open-hole heads may be misleading when determining potential flow directions at contamination sites, because they are a composite of the heads associated with each of the fractures intersecting the borehole. The flowmeter tool and straddle-packer apparatus are effective screening tools for generating a snapshot of the hydraulic conditions, including vertical flow, transmissivity, and heads; however, they cannot prevent flow and potential cross-contamination and cannot easily be used to monitor long-term conditions. This work was conducted as part of a larger multidisciplinary investigation to characterize the nature and extent of contamination in the soil, surface water, and ground water in the overburden and fractured bedrock in the area of the landfill and former chemical-waste disposal pits near the University of Connecticut. The methods and hydraulic data presented in this report were used along with surface- and borehole-geophysical data and geochemical data to understand and characterize the ground-water flow in overburden and fractured bedrock; to assess possible chemical migration; to develop a site conceptual ground-water flow model; and to assess remediation alternatives.

Connecticut

Borehole-geophysical investigation of the University of Connecticut landfill, Storrs, Connecticut

A borehole-geophysical investigation was conducted to help characterize the hydrogeology of the fractured-rock aquifer and the distribution of unconsolidated glacial deposits near the former landfill and chemical waste-disposal pits at the University of Connecticut in Storrs, Connecticut. Eight bedrock boreholes near the landfill and three abandoned domestic wells located nearby were logged using conventional and advanced borehole-geophysical methods from June to October 1999. The conventional geophysical-logging methods included caliper, gamma, fluid temperature, fluid resistivity, and electromagnetic induction. The advanced methods included deviation, optical and acoustic imaging of the borehole wall, heat-pulse flowmeter, and directional radar reflection. Twenty-one shallow piezometers (less than 50-feet deep) were logged with gamma and electromagnetic induction tools to delineate unconsolidated glacial deposits. Five additional shallow bedrock wells were logged with conventional video camera, caliper, electromagnetic induction, and fluid resistivity and temperature tools. The rock type, foliation, and fracturing of the site were characterized from high-resolution optical-televiewer (OTV) images of rocks penetrated by the boreholes. The rocks are interpreted as fine- to medium-grained quartz-feldsparbiotite-garnet gneiss and schist with local intrusions of quartz diorite and pegmatite and minor concentrations of sulfide mineralization similar to rocks described as the Bigelow Brook Formation on regional geologic maps. Layers containing high concentrations of sulfide minerals appear as high electrical conductivity zones on electromagneticinduction and borehole-radar logs. Foliation in the rocks generally strikes to the northeast-southwest and dips to the west, consistent with local outcrop observations. The orientation of foliation and small-scale gneissic layering in the rocks, however, varies locally and with depth in some of the boreholes. In two of the boreholes, the foliation strikes predominantly to the northwest and dips to the northeast. Although small-scale faults and lithologic discontinuities were observed in the OTV data, no large-scale faults were observed that appear on regional geologic maps. Fractures were located and characterized through the use of conventional geophysical, OTV, acoustic-televiewer (ATV), and borehole-radar logs. The orientation of fractures varies considerably across the site; some fractures are parallel to the foliation, whereas others cross-cut the foliation. Many of the transmissive fractures in the bedrock boreholes strike about N170°E and N320°E with dips of less than 45°. Other transmissive fractures strike about N60°E with dips of more than 60°. Most of the transmissive fractures in the domestic wells strike about N60°E and N22°E with dips of more than 45°. The strike of N60°E is parallel to the trend of a thrust fault that appears on regional geologic maps. Vertical flow in the boreholes was measured with the heat-pulse flowmeter under ambient and (or) pumping conditions. Results of ATV, OTV, and conventional logs were used to locate specific zones for flowmeter testing. Ambient downflow was measured in three boreholes, ambient upflow was measured in two other boreholes, and both ambient downflow and upflow were measured in a sixth borehole. The other five bedrock boreholes and domestic wells did not have measurable vertical flow. The highest rate of ambient flow was measured in the background borehole in which upflow and downflow converged and exited the borehole at a fracture zone near a depth of 62 feet. Ambient flow of about 340 gallons per day was measured. In the other five wells, ambient flow of about 20 to 35 gallons per day was measured. Under low-rate pumping (0.25 to 1 gallon per minute), one to six inflow zones were identified in each well. Usually the fractures that are active under ambient conditions contribute to the well under pumping conditions. To prevent ambient vertical flow and the potential for cross-contamination, temporary borehole liners were installed in five of the boreholes. Specific-capacity and open-hole transmissivity values were determined in eight boreholes completed in bedrock. The specific capacity estimated for these boreholes ranges from 0.14 to 1.6 gallons per minute per foot. The values for open-hole transmissivity range over two orders of magnitude and when proportioned to individual fracture transmissivity, range from 23 to 340 feet squared per day. Two boreholes had been drilled to intersect electrically conductive zones identified by previous surface-geophysical investigations. The borehole-geophysical results indicate that the boreholes penetrate electrically conductive structures consistent with the anomalies interpreted from the surface-geophysical data. Borehole MW121R was located to intersect a dipping electrically conductive anomaly at about 60 feet, interpreted from the two-dimensional direct currentresistivity survey conducted on the western side of the landfill. The electromagnetic-conductivity log in the borehole contains a high electrical conductivity anomaly at a depth of 69 feet. The magnitude of this anomaly is nearly 10,000 millisiemens per meter and is coincident with a layer containing sulfide mineralization, rather than fractures. The other borehole, MW105R, was located to intersect another anomaly south of the landfill. This anomaly was interpreted as a north-south striking, westward dipping feature. In the borehole, two south-striking, westward dipping fractures were identified in the ATV, OTV, and radar logs. The specific conductance of the fluid measured near these fractures was as high as 1,250 microsiemens per centimeter. Water-quality samples collected in October 1999 from an isolated zone from 71.5 to 76.5 feet indicated high specific conductance (810 microsiemens per centimeter), high concentrations of iron and cadmium, negative oxidation-reduction potential, and chlorobenzene. Collectively, these parameters indicate that the high specific conductance in the borehole logs for MW105R was caused by landfill leachate. Therefore, the anomaly identified by boreholeand surface-geophysical surveys is interpreted as a conductive lithologic feature and a permeable fracture zone that contains landfill leachate.

Connecticut

An integrated surface-geophysical investigation of the University of Connecticut landfill, Storrs, Connecticut: 2000

A surface-geophysical investigation to characterize the hydrogeology and contaminant distribution of the former landfill area at the University of Connecticut in Storrs, Connecticut, was conducted in 2000 to supplement the preliminary hydrogeologic assessment of the contamination of soil, surface water, and ground water at the site. A geophysical-toolbox approach was used to characterize the hydrogeology and contaminant distribution of the former landfill. Two-dimensional direct-current resistivity, inductive terrain-conductivity, and seismic-refraction surface-geophysical data were collected and interpreted in an iterative manner with exploratory drilling, borehole geophysics, and hydraulic testing. In this investigation, a geophysical-toolbox approach was used to 1) further define previously identified conductive anomalies and leachate plumes; 2) identify additional leachate plumes, possible fracture zones, and (or) conductive lithologic layers in the bedrock; and 3) delineate bedrock-surface topography in the drainage valleys north and south of the landfill. Resistivity and terrain-conductivity surveys were used to further delineate previously identified geophysical anomalies to the north and southwest of the landfill. A conductive anomaly identified in the terrain-conductivity survey to the north of the landfill in 2000 had a similar location and magnitude as an anomaly identified in terrain-conductivity surveys conducted in 1998 and 1999. Collectively, these surveys indicated that the magnitude of the conductive anomaly decreased with depth and with distance from the landfill. These anomalies indicated landfill leachate in the overburden and shallow bedrock. Results of previous surface-geophysical investigations southwest of the landfill indicated a shallow conductive anomaly in the overburden that extended into the fractured-bedrock aquifer. This conductive anomaly had a sheet-like geometry that had a north-south strike, dipped to the west, and terminated abruptly about 450 feet southwest of the landfill. The sheet-like conductive anomaly was interpreted as a fractured, conductive lithologic feature filled with conductive fluids. To further delineate this anomaly, two two-dimensional resistivity profiles were collected west of the sheet-like conductive anomaly to assess the possibility that the sheet-like conductive anomaly continued to the west in its down-dip direction. Each of the north-south oriented resistivity profiles showed bullet-shaped rather than linear-shaped anomalies, with a relatively smaller magnitude of conductivity than the sheet-like conductive anomaly to the east. If these bullet-like features are spatially connected, they may represent a linear, or pipe-like, conductive anomaly in the bedrock with a trend of N290°E and a plunge of 12°. Additional surveys were conducted to assess the apparent southern termination of the sheet-like conductive feature. Terrain-conductivity surveys indicated the sheet-like feature was not continuous to the south. A two-dimensional resistivity line and a coincident terrain-conductivity profile indicated the presence of a steep, eastward dipping, low magnitude, electrically conductive anomaly on the eastern end of the profile. Although the sheet-like conductive anomaly apparently did not continue to the south, the survey conducted in 2000 identified an isolated, weak conductive anomaly south of the previously identified anomaly. Inductive terrain-conductivity surveys performed north of the sheet-like conductive anomaly and west of the landfill indicated the anomaly did not extend to the north into the area of the former chemical-waste disposal pits. No conductive plumes or conductive features were observed in the subsurface bedrock west of the landfill. A conductive anomaly was identified in the southern section of the new terrain-conductivity grid. The magnitude and distribution of the apparent conductivity of this anomaly was identified as a nearly vertical sheet-like conductive feature. The anomaly extended north-south for 150 feet, and the depth and (or) magnitude of the conductive anomaly decreased towards the south. Based on the location, orientation, and dip, this feature was interpreted as a separate anomaly rather than as a continuation of the sheet-like, conductive bedrock feature that was previously identified southwest of the landfill. No other new conductive anomalies were identified south or west of the landfill. Seismic-refraction surveys were used to delineate the depth to the water table and the depth and topography of the bedrock surface. The seismic-refraction surveys at the northern and southern ends of the landfill confirm the presence of shallow bedrock at 25 feet below land surface. Seismic-refraction surveys conducted southwest of the landfill in a minor topographic valley indicate the bedrock is about 10 feet below land surface.

Connecticut

Surface-geophysical investigation of the University of Connecticut landfill, Storrs, Connecticut

A surface-geophysical investigation of the former landfill area at the University of Connecticut in Storrs, Conn. was conducted as part of a preliminary hydrogeologic assessment of the contamination of soil, surface water, and ground water at the site. Geophysical data were used to help determine the dominant direction of fracture strike; subsurface structure of the landfill; locations of possible leachate plumes, fracture zones or conductive lithologic layers; and the location and number of chemical waste-disposal pits. Azimuthal square-array direct-current (dc) resistivity, two-dimensional (2D) dc-resistivity, inductive terrain conductivity, and ground-penetrating radar (GPR) were the methods used to characterize the landfill area.The dominant strike direction of bedrock fractures interpreted from azimuthal square-array resistivity data is north, ranging from 285 to 30 degrees east of True North. These results complement local geologic maps that identify bedrock foliation and fractures that strike approximately north-south and dip 30 to 40 degrees west.The subsurface structure of the landfill was imaged with 2D dc-resistivity profiling data, which were used to interpret a landfill thickness of 10 to 15 meters. Orientation of the landfill trash disposal trenches were detected by azimuthal square-array resistivity soundings; the dimension and the orientation of the trenches were verified by aerial photographs.Inductive terrain conductivity and 2D dc-resistivity profiling detected conductive anomalies that were interpreted as possible leachate plumes near two surface-water discharge areas. The conductive anomaly to the north of the landfill is interpreted to be a shallow leachate plume and dissipates to almost background levels 45 meters north of the landfill. The anomaly to the southwest is interpreted to extend vertically through the overburden and into the shallow bedrock and laterally along the intermittent drainage to Eagleville Brook, terminating 140 meters south of the landfill. Inductive terrain conductivity and 2D dc-resistivity profiling also detected two dipping, sheet-like conductive features that extend vertically into the bedrock. These features were interpreted either as fracture zones filled with conductive fluids or conductive lithologic layers between more resistive layers. One dipping conductive feature was detected south of the landfill, and the other feature was detected to the west of the former chemical waste-disposal pits. Both anomalies strike approximately north-south and dip about 30 degrees to the west.GPR was used unsuccessfully to locate the former chemical waste-disposal pits. Although the entire overburden and the upper few meters of bedrock were imaged, no anomalous features were detected with GPR that could be correlated with the pits. It is possible that the area surveyed by GPR was entirely backfilled after the soil was removed from the site and that the outline of the former chemical waste-disposal pits no longer exists.

Connecticut