Concentrations of metals and bacterial spores in sediments near the Massachusetts Bay Outfall before and after discharge began
No abstract available.
Geology topics
Source-linked reports with geographic coverage including Massachusetts.
No abstract available.
This CD-ROM contains photographs and sediment sample analyses of the sea floor obtained at 142 sites in western Massachusetts Bay (Figure 1) during a research cruise (USGS cruise ISBL99024) aboard the Fishing Vessel (FV) Isabel S. (Figure 2) conducted July 18-21, 1999. These photographs and samples provide critical ground truth information for the interpretation of shaded relief and backscatter intensity maps created using data collected with a multibeam echo sounder system (Butman and others, in press, a, b, c; Valentine and others, in press, a, b, c). Collection of these photographs and samples was undertaken in support of a large project whose overall objective is to map and describe the sea floor of Massachusetts Bay.
An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table.
A pilot-scale study was conducted by the U.S. Army National Guard (USANG) at the Massachusetts Military Reservation (MMR) on Cape Cod, Massachusetts, to assess the use of a hydraulic-fracturing method to create vertical, permeable walls of zero-valent iron to passively remediate ground water contaminated with chlorinated solvents. The study was conducted near the source area of the Chemical Spill-10 (CS-10) plume, a plume containing chlorinated solvents that underlies the MMR. Ground-water contamination near the source area extends from about 24 m (meters) to 35 m below land surface. The USANG designed two reactive-iron walls to be 12 m long and positioned 24 to 37 m below land surface to intersect and remediate part of the CS-10 plume.Because iron, as an electrical conductor, absorbs electromagnetic energy, the US Geological Survey used a cross-hole common-depth, radar scanning method to assess the continuity and to estimate the lateral and vertical extent of the two reactive-iron walls. The cross-hole radar surveys were conducted in boreholes on opposite sides of the iron injection zones using electric-dipole antennas with dominant center frequencies of 100 and 250 MHz. Significant decreases in the radar-pulse amplitudes observed in scans that traversed the injection zones were interpreted by comparing field data to results of two-dimensional finite-difference time-domain numerical models and laboratory-scale physical models.The numerical and physical models simulate a wall of perfectly conducting material embedded in saturated sand. Results from the numerical and physical models show that the amplitude of the radar pulse transmitted across the edge of a conductive wall is about 43 percent of the amplitude of a radar pulse transmitted across background material. The amplitude of a radar pulse transmitted through a hole in a conductive wall increases as the aperture of the hole increases. The modeling results indicate that holes with an aperture of less than 40 percent of the dominant wavelength of the radar pulse are not likely to be detected.Based on the results of the numerical and physical modeling, the decreases in radar-pulse amplitudes observed in scans traversing the injection zones are interpreted as electrically conductive zones that outline the distribution of iron. The area interpreted as iron in the northern A-wall contains two zones -- an upper zone about 10 m wide, extending from about 25 to 31 m below land surface, and a lower zone about 8 m wide, extending from 31.5 to 34.5 m below land surface. The area interpreted as iron in the southern B-wall is about 9 m wide, extending from about 27 to 34.5 m below land surface. No discrete holes were interpreted in either the A- or B-wall zones.The interpretation of the field data suggests that (1) the hydraulic-fracturing method introduced iron into the subsurface, but not in the dimensions originally proposed; (2) the iron within the treatment zones is distributed in a generally continuous manner; and (3) excluding the discontinuity in the A-wall, holes within the iron treatment zone, if any, exist at scales smaller than about 10 cm, the resolution limit of the radar antennas and acquisition geometry used for this study. The cross-hole radar method appears to have been an effective method for delineating the distribution of iron in the two walls; however, the veracity of the results cannot be ascertained without excavation or drilling into the treatment zone.
Measurements of elevated concentrations of polychlorinated biphenyls (PCBs) in fish and in streambed sediments of the Millers River Basin, Massachusetts and New Hampshire, have been reported without evidence of the PCB source. In 1999, an investigation was initiated to determine the source(s) of the elevated PCB concentrations observed in fish and to establish the extent of fish exposure to PCBs along the entire main stems of the Millers River and one of its tributaries, the Otter River. Passive samplers deployed for 2-week intervals in the water-column at 3 1 stations, during summer and fall 1999, were used to assess PCB concentrations in the Millers River Basin. The samplers concentrate PCBs, which diffuse from the water column through a polyethylene membrane to hexane (0.200 liters) contained inside the samplers. Only dissolved PCBs (likely equivalent to the bioavailable fraction) are subject to diffusion through the membrane. The summed concentrations of all targeted PCB congeners (summed PCB) retrieved from the samplers ranged from 1 to 8,000 nanograms per hexane sample. Concentration and congener-pattern comparisons indicated that the historical release of PCBs in the Millers River Basin likely occurred on the Otter River at the upstream margin of Baldwinville, Mass. Elevated water-column concentrations measured in a wetland reach on the Otter River downstream from Baldwinville were compatible with a conceptual model for a present-day (1999) source in streambed sediments, to which the PCBs partitioned after their original introduction into the Otter River and from which PCBs are released to the water now that the original discharge has ceased or greatly decreased. Two four-fold decreases in summed PCB concentrations in the Millers River, by comparison with the highest concentration on the Otter River, likely were caused by (1) dilution with water from the relatively uncontaminated upstream Millers River and (2) volatilization of PCBs from the Millers River in steep-gradient reaches. A relatively constant concentration of summed PCBs in the reach of the Millers River from river mile 20 to river mile 10 was likely a consequence of a balance between decreased volatilization rates in that relatively low-gradient reach and resupply of PCBs to the water column from contaminated streambed sediments. A second high-gradient reach from river mile 10 to the confluence of the Millers River with the Connecticut River also was associated with a decrease in concentration of water-column summed PCBs. Volatilization as a loss mechanism was supported by evidence in the form of slight changes of the congener pattern in the reaches where decreases occurred. Exposure of fish food webs to concentrations of dissolved PCBs exceeded the U.S. Environmental Protection Agency's water-quality criterion for PCBs throughout most of the Millers River and Otter River main stems. Because the apparent source of PCBs discharged was upstream on the Otter River, a large number of river miles downstream (more than 30 mi) had summer water-column PCB concentrations that would likely lead to high concentrations of PCBs in fish.
During the spring and summer of 1996, 1997, and 1998, measurements of phytoplankton- chlorophyll concentration, Secchi disk transparency, and color were made at 97 Massachusetts lakes within 24 hours of Landsat Thematic Mapper imaging of the lakes in an effort to assess water quality and trophic state. Spatial distributions of floating, emergent, and submerged macrophytes were mapped in 49 of the lakes at least once during the 3-year period. The maps were digitized and used to assign pixels in the thematic mapper images to one of four vegetation cover classes-open water, 150 percent floating-and-emergent-vegetation cover, 51100 percent floating-and-emergent-vegetation cover, and submerged vegetation at any density. The field data were collected by teams of U.S. Geological Survey and Massachusetts Department of Environmental Management staff and by 76 volunteers. Side-by-side sampling by U.S. Geological Survey and volunteer field teams resulted in statistically similar chlorophyll determinations, Secchi disk readings, and temperature measurements, but concurrent color determinations were not similar, possibly due to contamination of sample bottles issued to the volunteers. Attempts to develop predictive relations between phytoplankton-chlorophyll concentration, Secchi disk transparency, lake color, dissolved organic carbon, and various combinations of thematic mapper bands 1, 2, 3, and 4 digital numbers were unsuccessful, primarily because of the extremely low concentrations of chlorophyll in the lakes studied, and also because of the highly variable dissolved organic carbon concentrations. Predictive relations were developed between Secchi disk transparency and phytoplankton-chlorophyll concentration, and between color and dissolved organic carbon concentration. Phytoplankton-chlorophyll concentration was inversely correlated with Secchi disk transparency during all three sampling periods. The relations were very similar in 1996 and 1997 and indicated that 62 to 67 percent of the variability in Secchi disk transparency could be explained by the chlorophyll concentration. Analysis of color and dissolved organic carbon concentrations in water samples collected by U.S. Geological Survey field teams in 199698 indicated that 91 percent of the variance in color in Massachusetts lakes can be explained by variations in dissolved organic carbon. Areas of open-water, submerged vegetation, and two surface-vegetation-cover classes predicted from Thematic Mapper images acquired in the summer of 1996 closely matched the areas observed in a set of field observations. However, the same analysis applied to a set of data acquired in the summer of 1997 resulted in somewhat less reliable predictions, and an attempt to predict 1996 vegetation-cover areas using the relations developed in the 1997 analysis was unsuccessful.
A U.S. Army facility on a peninsula in South Pond of Lake Cochituate was designated a Superfund site by the U.S. Environmental Protection Agency in 1994 because contaminated ground water was detected at the facility, which is near the Natick Springvale public-supply wellfield. The interaction between South Pond and the underlying aquifer controls ground-water flow patterns near the pond and determines the source of water withdrawn from the wellfield. A map of the bathymetry and the thickness of fine-grained pond-bottom sediments was prepared on the basis of fathometer, ground-penetrating radar, and continuous seismic-reflection surveys. The geophysical data indicate that the bottom sediments are fine grained toward the middle of the pond but are coarse grained in shoreline areas. Natick Springvale wellfield, which consists of three active public-supply wells adjacent to South Pond, is 2,200 feet downgradient from the boundary of the Army facility. That part of South Pond between the Natick Springvale wellfield and the Army facility is 18 feet deep with at least 14 feet of fine-grained sediment beneath the pond-bottom. Water levels from the pond and underlying sediments indicate a downward vertical gradient and the potential for infiltration of pond water near the wellfield. Head differences between the pond and the wellfield ranged from 1.66 to 4.41 feet during this study. The velocity of downward flow from South Pond into the pond-bottom sediments, determined on the basis of temperature profiles measured over a diurnal cycle at two locations near the wellfield, was 0.5 and 1.0 feet per day. These downward velocities resulted in vertical hydraulic conductivities of 1.1 and 2.9 feet per day for the pond-bottom sediments. Naturally occurring stable isotopes of oxygen and hydrogen were used as tracers of pond water and ground water derived from recharge of precipitation, two potential sources of water to a well in a pond-aquifer setting. The isotopic composition of pond water varied seasonally and was distinctly different from the isotopic composition of ground water. The isotopic composition of shallow water beneath and adjacent to South Pond near the wellfield corresponds to the temporal variation of pond water, indicating that nearly all water at shallow depths was derived from pond water. A two-component mixing model based on the average stable isotope values of the source waters indicated that 64 ±15 percent at the 95-percent confidence interval of the water withdrawn at the public-supply wells was derived from the pond; pond water accounted for most of the uncertainty in the result. The rate of infiltration of pond water into the aquifer and discharging to the wellfield was 1.0 million gallons per day at the average pumping rate.
Analyses of water samples collected from 29 wells across the Boston metropolitan area indicate that shallow ground water in recently urbanized settings often contains trace amounts of nutrients, fuel, and industrial-based organic compounds. Most of the samples that contained detectable amounts of organic compounds also had elevated levels of iron and total dissolved solids. Nitrate was detected in 83 percent of the samples, but the U.S. Environmental Protection Agency's (USEPA) drinking-water standard of 10 milligrams per liter nitrate was exceeded in just one sample. Low levels of volatile organic compounds (VOCs) were detected in 76 percent of the samples, with as many as 13 different VOCs detected in a single sample. The concentration of methyl-tert-butyl ether (MTBE) in one sample was 267 micrograms per liter, which exceeds the Massachusetts Department of Environmental Protection drinking-water guideline of 70 micrograms per liter. Chloroform and MTBE were the two most frequently detected VOCs. MTBE was detected at the same frequency in ground water in the Boston metropolitan area as in other urban areas of New England. Chloroform is detected at higher frequency in old, densely populated areas in New England than in more recently developed, less densely populated areas. Pesticide detections were few, but only at trace concentrations, and none of the concentrations exceeded any drinking-water standard.
A water-quality monitoring program is proposed that would provide data to meet multiple information needs of Massachusetts agencies and other users concerned with the condition of the State's water resources. The program was designed by the U.S. Geological Survey and the Massachusetts Department of Environmental Protection, Division of Watershed Management, with input from many organizations involved in water-quality monitoring in the State, and focuses on inland surface waters (streams and lakes). The proposed monitoring program consists of several components, or tiers, which are defined in terms of specific monitoring objectives, and is intended to complement the Massachusetts Watershed Initiative (MWI) basin assessments. Several components were developed using the Neponset River Basin in eastern Massachusetts as a pilot area, or otherwise make use of data from and sampling approaches used in that basin as part of a MWI pilot assessment in 1994. To guide development of the monitoring program, reviews were conducted of general principles of network design, including monitoring objectives and approaches, and of ongoing monitoring activities of Massachusetts State agencies. Network tiers described in this report are primarily (1) a statewide, basin-based assessment of existing surface-water-quality conditions, and (2) a fixed-station network for determining contaminant loads carried by major rivers. Other components, including (3) targeted programs for hot-spot monitoring and other objectives, and (4) compliance monitoring, also are discussed. Monitoring programs for the development of Total Maximum Daily Loads for specific water bodies, which would constitute another tier of the network, are being developed separately and are not described in this report. The basin-based assessment of existing conditions is designed to provide information on the status of surface waters with respect to State water-quality standards and designated uses in accordance with the reporting requirements [Section 305(b)] of the Clean Water Act (CWA). Geographic Information System (GIS)-based procedures were developed to inventory streams and lakes in a basin for these purposes. Several monitoring approaches for this tier and their associated resource requirements were investigated. Analysis of the Neponset Basin for this purpose demonstrated that the large number of sites needed in order for all the small streams in a basin to be sampled (about half of stream miles in the basin were headwater or first-order streams) pose substantial resource-based problems for a comprehensive assessment of existing conditions. The many lakes pose similar problems. Thus, a design is presented in which probabilistic monitoring of small streams is combined with deterministic or targeted monitoring of large streams and lakes to meet CWA requirements and to provide data for other information needs of Massachusetts regulatory agencies and MWI teams. The fixed-station network is designed to permit the determination of contaminant loads carried by the State's major rivers to sensitive inland and coastal receiving waters and across State boundaries. Sampling at 19 proposed sites in 17 of the 27 major basins in Massachusetts would provide information on contaminant loads from 67 percent of the total land area of the State; unsampled areas are primarily coastal areas drained by many small streams that would be impossible to sample within realistic resource limitations. Strategies for hot-spot monitoring, a targeted monitoring program focused on identifying contaminant sources, are described with reference to an analysis of the bacteria sampling program of the 1994 Neponset Basin assessment. Finally, major discharge sites permitted under the National Pollutant Discharge Elimination System (NPDES) were evaluated as a basis for ambient water-quality monitoring. The discharge sites are well distributed geographically among basins, but are primarily on large rivers (two-thirds or more on fourth- or higher order streams). Thus, NPDES sites alone would provide a biased estimate of existing water-quality conditions, but might be useful for some loads determinations if data of sufficient quality could be collected.
The trophic ecology and ground-water contributing area of Walden Pond, in Concord and Lincoln, Mass., were investigated by the U.S. Geological Survey in cooperation with the Massachusetts Department of Environmental Management from April 1997 to July 2000. Bathymetric investigation indicated that Walden Pond (24.88 hectares), a glacial kettle-hole lake with no surface inlet or outlet, has three deep areas. The maximum depth (30.5 meters) essentially was unchanged from measurements made by Henry David Thoreau in 1846. The groundwater contributing area (621,000 square meters) to Walden Pond was determined from water-table contours in areas of stratified glacial deposits and from land-surface contours in areas of bedrock highs. Walden Pond is a flow-through lake: Walden Pond gains water from the aquifer along its eastern perimeter and loses water to the aquifer along its western perimeter. Walden Pond contributing area also includes Goose Pond and its contributing area. A water budget calculated for Walden Pond, expressed as depth of water over the lake surface, indicated that 45 percent of the inflow to the lake was from precipitation (1.215 meters per year) and 55 percent from ground water (1.47 meters per year). The groundwater inflow estimate was based on the average of two different approaches including an isotope mass-balance approach. Evaporation accounted for 26 percent of the outflow from the lake (0.71 meters per year) whereas lake-water seepage to the groundwater system contributed 74 percent of the outflow (1.97 meters per year). The water-residence time of Walden Pond is approximately 5 years. Potential point sources of nutrients to ground water, the Concord municipal landfill and a trailer park, were determined to be outside the Walden Pond groundwater contributing area. A third source, the septic leach field for the Walden Pond State Reservation facilities, was within the groundwater contributing area. Nutrient budgets for the lake indicated that nitrogen inputs (858 kilograms per year) were dominated (30 percent) by plume water from the septic leach field and, possibly, by swimmers (34 percent). Phosphorus inputs (32 kilograms per year) were dominated by atmospheric dry deposition, background ground water, and estimated swimmer inputs. Swimmer inputs may represent more than 50 percent of the phosphorus load during the summer. The septic-system plume did not contribute phosphorus, but increased the nitrogen to phosphorus ratio for inputs from 41 to 59, on an atom-to-atom basis. The ratio of nitrogen to phosphorus in input loads and within the lake indicated algal growth would be strongly phosphorus limited. Nitrogen supply in excess of plant requirements may mitigate against nitrogen fixing organisms including undesirable blooms of cyanobacteria. Based on areal nutrient loading, Walden Pond is a mesotrophic lake. Hypolimnetic oxygen demand of Walden Pond has increased since a profile was measured in 1939. Currently (1999), the entire hypolimnion of Walden Pond becomes devoid of dissolved oxygen before fall turnover in late November; whereas historical data indicated dissolved oxygen likely remained in the hypolimnion during 1939. The complete depletion of dissolved oxygen likely causes release of phosphorus from the sediments. Walden Pond contains a large population of the deep-growing benthic macro alga Nitella , which has been hypothesized to promote water clarity in other clear-water lakes by sequestering nutrients and keeping large areas of the sediment surface oxygenated. Loss of Nitella populations in other lakes has correlated with a decline in water quality. Although the Nitella standing crop is large in Walden Pond, Nitella still appears to be controlled by nutrient availability. Decreasing phosphorus inputs to Walden Pond, by amounts under anthropogenic control would likely contribute to the stability of the Nitella population in the metalimnion, may reverse oxygen depletion in the hypolimnion, and decrease recycling of phosphorus from the sediments.
Walden Pond and the underlying and surrounding aquifer are bordered by the Sudbury and Concord Rivers (fig. 1). Walden Pond, a kettle-hole lake with no surface water inlet or outlet, formed at the end of the last glaciation about15,000 years ago by the melting of a large block of ice that broke off into glacial Lake Sudbury from the retreating glacier. The ice block eventually was surrounded by sorted, stratified sediments ranging mainly from fine sand to coarse gravel deposited by glacial meltwater (fig. 2), (Koteff, 1963). Seismic reflection and fathometer data indicate that the lake and its associated fine-grained bottom sediments extend to the till and bedrock surface in the deepest areas. Three deep areas are defined in the lake (fig. 3); the middle deep area was unmapped before this investigation. The maximum measured depth of 100.1 feet (ft) was within 2 ft of that measured by Thoreau in the winter of 1846. Knowledge of the water balance and the land-surface area contributing water to Walden Pond is needed to understand the hydrology of the lake and to derive a nutrient budget for the lake. Sources of water to Walden Pond include precipitation on the lake surface and ground water (fig. 2). Water from precipitation infiltrates the permeable surficial deposits, recharges the aquifer, then flows in the direction of decreasing water levels. Thus, ground-water flow does not necessarily follow land surface topography. Along steep shoreline areas sloping towards Walden Pond, small quantities of overland flow may occur after intense precipitation events, thereby adding small amounts of water to the lake. Water leaves Walden Pond by evaporation from the lake surface and from lake-water seepage to the aquifer (fig. 2).
This report presents the results of a study conducted by the U.S. Geological Survey, in cooperation with the city of Cambridge, Massachusetts, Water Department, to assess reservoir and tributary-stream quality in the Cambridge drinking-water source area, and to use the information gained to help guide the design of a comprehensive water-quality monitoring program for the source area. Assessments of the quality and trophic state of the three primary storage reservoirs, Hobbs Brook Reservoir, Stony Brook Reservoir, and Fresh Pond, were conducted (September 1997-November 1998) to provide baseline information on the state of these resources and to determine the vulnerability of the reservoirs to increased loads of nutrients and other contaminants. The effects of land use, land cover, and other drainage-basin characteristics on sources, transport, and fate of fecal-indicator bacteria, highway deicing chemicals, nutrients, selected metals, and naturally occurring organic compounds in 11 subbasins that contribute water to the reservoirs also was investigated, and the data used to select sampling stations for incorporation into a water-quality monitoring network for the source area. All three reservoirs exhibited thermal and chemical stratification, despite artificial mixing by air hoses in Stony Brook Reservoir and Fresh Pond. The stratification produced anoxic or hypoxic conditions in the deepest parts of the reservoirs and these conditions resulted in the release of ammonia nitrogen orthophosphate phosphorus, and dissolved iron and manganese from the reservoir bed sediments. Concentrations of sodium and chloride in the reservoirs usually were higher than the amounts recommended by the U.S. Environmental Protection agency for drinking-water sources (20 milligrams per liter for sodium and 250 milligrams per liter for chloride). Maximum measured sodium concentrations were highest in Hobbs Brook Reservoir (113 milligrams per liter), intermediate in Stony Brook Reservoir (62 milligrams per liter), and lowest in Fresh Pond (54 milligrams per liter). Bed sediments in Hobbs Brook and Stony Brook Reservoirs were enriched in iron, manganese, and arsenic relative to those in the impounded lower Charles River in Boston, Massachusetts. Trophic state indices, calculated for each reservoir based on nutrient concentrations, water-column transparency, and phytoplankton abundances, indicated that the upper and middle basins of Hobbs Brook Reservoir were moderately to highly productive and likely to produce algal blooms; the lower basin of Hobbs Brook Reservoir and Stony Brook Reservoir were similar and intermediate in productivity, and Fresh Pond was relatively unproductive and unlikely to produce algal blooms. This pattern is likely due to sedimentation of organic and inorganic particles in the three basins of Hobbs Brook Reservoir and in Stony Brook Reservoir. Molar ratios of nitrogen to phosphorus ranged from 55 in Stony Brook Reservoir to 120 in Hobbs Brook Reservoir, indicating that phytoplankton algae in these water bodies may be phosphorus limited and therefore sensitive to small increases in phosphorus loading from the drainage basin. Nitrogen loads were found to be less important than phosphorus to the trophic condition of the reservoirs. Hobbs Brook and Stony Brook, the two principle streams draining the Cambridge drinking-water source area, differed in their relative contributions to many of the estimated constituent loads. The estimated load of fecal coliform bacteria was more than seven times larger for the mainly residential Stony Brook subbasin upstream from Kendal Green, Mass., than it was for the more commercial and industrial Hobbs Brook subbasin, though the drainage areas of the two subbasins differ only by about 20 percent. The State standard for fecal coliform bacteria in streams in the Cambridge drinking-water source area (20 colony forming units per 100 milliliters) was exceeded at all sampling stations. Estimated s
The relations among stream habitat, fish communities, and hydrologic conditions were investigated in the Ipswich River Basin in northeastern Massachusetts. Data were assessed from 27 sites on the mainstem of the Ipswich River from July to September 1998 and from 10 sites on 5 major tributaries in July and August 1999. Habitat assessments made in 1998 determined that in a year with sustained streamflow for most of the summer, the Ipswich River contains diverse, high-quality aquatic habitat. Channel types are predominantly low gradient glides, pools, and impoundments, with a sandy streambed and a forest or shrub riparian zone. Features that provide fish habitat are located mostly along stream margins; these features include overhanging brush, undercut banks, exposed roots, and woody debris. These habitat features decrease in availability to aquatic communities with declining streamflows and generally become unavailable after streamflows drop to the point where the edge of water recedes from the stream banks. The mainstem and tributaries were sampled to determine fish species composition, relative abundance, and length frequency. Fish sampling indicates that the fish community in the Ipswich River is currently a warm-water fish community dominated by pond-type fish. However, historical temperature data, and survival of stocked trout in the mainstem Ipswich into late summer of 1998, indicate that the Ipswich River potentially could support cold-water fish species if adequate flows are maintained. Dominant fish species sampled in the mainstem Ipswich River were redfin pickerel ( Esox americanus ), American eel ( Anguilla rostrata ), and pumpkinseed ( Lepomis gibbosus ), which together represented 41, 22, and 10 percent, respectively, of 4,745 fish sampled. The fish communities of the mainstem and tributaries contained few fluvial-dependent or fluvial-specialist species (requiring flow), and were dominated by macrohabitat generalists (tolerant of low-flow, warm-water, and ponded conditions). In comparison to a nearby river (Lamprey River, N.H.), and a reference fish community developed for inland New England streams, the Ipswich fish community would be expected to have appreciably higher percentages of fluvial-dependent and fluvial-specialist species were streamflows restored. Four riffle sites on the mainstem of the Ipswich River were identified as critical habitat areas because they are among the first sites to exhibit fish-passage problems or to dry during low flows. A watershed-scale precipitation-runoff model previously developed for the Ipswich River was used to simulate streamflows at these four sites for the period 196195 under no withdrawals (for water supply) and 1991 land use to evaluate habitat suitability under conditions that approximate the natural flow conditions. These simulated flows were used to calculate streamflow requirements by the Tennant and New England Aquatic-Base-Flow methods. Stream channels were surveyed at the critical riffle sites, and Water Surface Profile models were used to simulate streamflows and hydraulic characteristics needed for determining streamflow requirements by use of the Wetted-Perimeter and R2Cross methods. Normalized by drainage area to units of cubic feet per second per square mile, these methods yielded the following streamflow requirements: 0.50 cubic feet per second per square mile for the Tennant 30-percent Q MA method, 0.42 cubic feet per second per square mile for the wetted-perimeter value necessary to maintain wetted perimeter at three altered riffle sites, 0.42 cubic feet per second per square mile for the R2Cross value required to maintain R2Cross hydraulic criteria at a natural riffle site, and 0.34 cubic feet per second per square mile for the aquatic-base-flow median of monthly mean flows for August for the simulated 196195 period under no withdrawals and 1991 land use. The mean streamflow requirement determined from these four methods is 0.42 cubic feet per second per square mile. This flow would represent an average flow-exceedence value for the six study sites of about 77 percent under simulated flows with no withdrawals. For these flows, the 70-, 80-, and 90-percent exceedence flows averaged 0.59, 0.37, and 0.21 cubic feet per second per square mile, respectively, and the 7-day, 10-year low flow statistic at the two gaged sites averaged 0.08 cubic feet per second per square mile. Simulated flows under no withdrawals were used to determine monthly mean flows and other flow statistics used in the Range of Variability Approach to define a flow regime that mimics the river's natural flow regime.
Boston is scheduled to cease discharge of sewage effluent in Boston Harbor in Spring 2000 and begin discharge at a site 14 km offshore in Massachusetts Bay in a water depth of about 30 m. The effects of this outfall relocation on effluent dilution, salinity and circulation are predicted with a three-dimensional hydrodynamic model. The simulations predict that the new bay outfall will greatly decrease effluent concentrations in Boston Harbor (relative to the harbour outfall) and will not significantly change mean effluent concentrations over most of Massachusetts Bay. With the harbour outfall, previous observations and these simulations show that effluent concentrations exceed 0??5% throughout the harbour, with a harbour wide average of 1-2%. With the bay outfall, effluent concentrations exceed 0??5% only within a few km of the new outfall, and harbour concentrations drop to 0??1-0??2%, a 10-fold reduction. During unstratified winter conditions, the local increase in effluent concentration at the bay outfall site is predicted to exist throughout the water column. During stratified summer conditions, however, effluent released at the sea bed rises and is trapped beneath the pycnocline. The local increase in effluent concentration is limited to the lower layer, and as a result, surface layer effluent concentrations in the vicinity of the new outfall site are predicted to decrease (relative to the harbour outfall) during the summer. Slight changes are predicted for the salinity and circulation fields. Removing the fresh water associated with the effluent discharge in Boston Harbor is predicted to increase the mean salinity of the harbour by 0??5 and decrease the mean salinity by 0??10-0??15 within 2-3 km of the outfall. Relative to the existing mean flow, the buoyant discharge at the new outfall is predicted to generate density-driven mean currents of 2-4 cm s-1 that spiral out in a clockwise motion at the surface during winter and at the pycnocline (15-20 m depth) during summer. Compensating counterclockwise currents are predicted to spiral in toward the source at the bottom. Because the scale of the residual current structure induced by the new discharge is comparable to or smaller than typical subtidal water parcel excursions, Lagrangian trajectories will not follow the Eulerian residual flow. Thus, mean currents measured from moorings within 5 km of the bay outfall site will be more useful for model comparison than to indicate net transport pathways.
Biotelemetry of shortnose sturgeon Acipenser brevirostrum and Atlantic sturgeon A. oxyrinchus oxyrinchus was used to study fish uses of habitat in several hierarchical classes in the Connecticut and Merrimack rivers. Hierarchical classes were geomorphological region (straight river run, run with an island, and river curve), river cross section (channel or shoal), and microhabitat (water depth, bottom current, substrate, and illumination). Coastal wandering juvenile Atlantic sturgeon were summer visitors to the Merrimack River, where they used a narrow range of habitat on all spatial scales, e.g., run-with-island, the channel portion of the cross section, and sand substrate. Shortnose sturgeon, year-round residents in both rivers, showed great individual variation in habitat use, and all ages selected a broad range of habitats on all spatial scales. However, shortnose sturgeon in both rivers preferred curves with sand or cobble substrate and avoided runs regardless of substrate. Individuals used channel or shoal at rates ranging from 0 to 100% on a weekly time scale in an unpredictable manner. Connecticut River shortnose sturgeon increased their use of curves, channels (deep water), and sand substrate in the fall. This strategy may conserve energy because these conditions usually reflect slow water velocity. Winter habitat selection continued the fall pattern, but was less variable because habitat affinity was highest among wintering fish. Documenting individual fish use of large-scale habitat revealed habitat relationships that would not have been discovered if only fish use of microhabitat had been studied.
An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table. The aquifer was pumped at a rate of 320 gallons per minute for 72-hours and drawdown measurements were made in the pumped well and in 20 piezometers located at various distances from the pumped well and depths below the land surface. To facilitate the analysis, an automatic parameter estimation algorithm was used to obtain relevant unconfined aquifer parameters, including the saturated thickness and a set of empirical parameters that relate to gradual drainage from the unsaturated zone. Drainage from the unsaturated zone is treated in this paper as a finite series of exponential terms, each of which contains one empirical parameter that is to be determined. It was necessary to account for effects of gradual drainage from the unsaturated zone to obtain satisfactory agreement between measured and simulated drawdown, particularly in piezometers located near the water table. The commonly used assumption of instantaneous drainage from the unsaturated zone gives rise to large discrepancies between measured and predicted drawdown in the intermediate-time range and can result in inaccurate estimates of aquifer parameters when automatic parameter estimation procedures are used. The values of the estimated hydraulic parameters are consistent with estimates from prior studies and from what is known about the aquifer at the site. Effects of heterogeneity at the site were small as measured drawdowns in all piezometers and wells were very close to the simulated values for a homogeneous porous medium. The estimated values are: specific yield, 0.26; saturated thickness, 170 feet; horizontal hydraulic conductivity, 0.23 feet per minute; vertical hydraulic conductivity, 0.14 feet per minute; and specific storage, 1.3x10-5 per foot. It was found that drawdown in only a few piezometers strategically located at depth near the pumped well yielded parameter estimates close to the estimates obtained for the entire data set analyzed simultaneously. If the influence of gradual drainage from the unsaturated zone is not taken into account, specific yield is significantly underestimated even in these deep-seated piezometers. This helps to explain the low values of specific yield often reported for granular aquifers in the literature. If either the entire data set or only the drawdown in selected deep-seated piezometers was used, it was found unnecessary to conduct the test for the full 72-hours to obtain accurate estimates of the hydraulic parameters. For some piezometer groups, practically identical results would be obtained for an aquifer test conducted for only 8-hours. Drawdowns measured in the pumped well and piezometers at distant locations were diagnostic only of aquifer transmissivity.
The unconfined sand-and-gravel aquifer in western Cape Cod, Massachusetts, which is the sole source of water supply for the communities in the area, is recharged primarily from precipitation. The rate of recharge from precipitation is estimated to be about 26 inches per year (in/yr), or about 60 percent of the precipitation rate. This recharge rate yields a flow through the aquifer of about 180 million gallons per day (Mgal/d). Groundwater flows radially outward from the top of the water-table mound in the north-central part of the flow system toward the coast, as indicated by the water-table contours on the large map on this sheet. Recharge that reaches the water table near the top of the mound travels deeper through the aquifer than recharge that reaches the water table closer to the coast. All recharge to the aquifer ultimately discharges to pumping wells, streams, or coastal areas; however, some of this recharge may flow first through kettle ponds before eventually reaching these discharge points. Continued land development and population growth on western Cape Cod, and activities related to the operation of the Massachusetts Military Reservation (MMR), have created concerns regarding the supply of potable water in western Cape Cod and the quality and quantity of water discharging to ponds, streams, and coastal areas. Recent investigations estimated the future demand for drinking water in western Cape Cod, as well as the areas that contribute water to existing and proposed public-supply wells. Determining the source of freshwater that discharges to ponds, streams, and coastal areas is of critical importance in the protection of these natural resources for the communities of western Cape Cod. The purpose of this report is to illustrate concepts of ground-water recharge areas under average pumping and recharge conditions. This report presents results of an investigation conducted by the U.S. Geological Survey (USGS), in cooperation with the Air Force Center for Environmental Excellence (AFCEE), to delineate the areas that contribute recharge to public-supply wells, ponds, streams, and coastal areas on western Cape Cod for average annual pumping and recharge rates for the period of 1994–1996. The time period of 1994–1996 was selected for this analysis because it represents the average stress conditions prior to large-scale pumping, treatment, and reinjection of water from the MMR Installation Restoration Program's ground-water remediation systems. The pumping and reinjection of large amounts of water from these remediation systems would complicate greatly the delineation of ground-water recharge areas and therefore is beyond the scope of this analysis. The Chemical Spill-4 plume-containment system, however, is included in the simulation since it has been operating since 1993 and has been pumping, treating, and reinjecting only about 0.2 Mgal/d of water. Since 1996, however, AFCEE has constructed remediation systems for seven additional contaminant plumes that are not included in this analysis. Currently (1999), these systems are pumping, treating, and reinjecting about 9.7 Mgal/d. By 2002, when all of these systems, including those being designed, are expected to be operating, it is estimated that they will be pumping, treating, and reinjecting as much as 15.6 Mgal/d of water in the western Cape Cod aquifer. For additional information on the hydrology and geology of western Cape Cod, the reader is referred to the following reports: LeBlanc and others (1986), Barlow and Hess (1993), Masterson and others (1997a), Masterson and others (1997b), Masterson and others (1998), Ogden Environmental and Energy Services, Inc. (1998) and Jacobs Engineering Group, Inc. (1999).
Diffusion samplers were installed in the bottom of Johns Pond, Cape Cod, Massachusetts, to confirm that volatile organic compounds from the Storm Drain-5 (SD-5) plume emanating from the Massachusetts Military Reservation (MMR) were discharging into the pond. An array of 134 vapor-diffusion samplers was buried by divers about 0.5 feet below the pond bottom in the presumed discharge area of the SD-5 plume and left in place for about 2 weeks to equilibrate. Two areas of high concentrations of volatile organic compounds (VOCs) were identified. Samples from the first area contained trichloroethene (TCE) and tetrachloroethene with concentrations in vapor as high as 890 and 667 parts per billion by volume, respectively. This discharge area is about 1,000 feet wide, extends from 100 to 350 feet offshore, and is interpreted to be the discharge area of the SD-5 plume. Samples from the second area were located closer to shore than the discharge area of the SD-5 plume and contained unexpectedly high vapor concentrations of TCE (more than 40,000 parts per billion by volume). Ground-water samples collected with a drive-point sampler near the second area had aqueous TCE concentrations as high as 1,100 micrograms per liter. Subsequently, a more closely spaced array of 110 vapor-diffusion samplers was installed to map the area of elevated TCE concentrations . The discharge area detected with the samplers is about 75 feet wide and extends from about 25 to 200 feet offshore . TCE vapor concentrations in this area were as high as 42,800 parts per billion by volume. TCE concentrations in micrograms per liter in water-diffusion samples from 15 selected sites in the two discharge areas were about 35 times lower than the TCE concentrations in parts per billion by volume in corresponding vapor-diffusion samples. The difference in values is due to the volatile nature of TCE and the different units of measure. TCE was detected in diffusion samplers set in the pond water column above the plume discharge areas, but the TCE concentrations were 20 to 30 times lower than the corresponding levels in diffusion samplers buried in the pond bottom.